XDF 1.110000 DO NOT HAND EDIT!!!! (Trust me) %%HEADER%% 001000 FileVers ="110408" 001005 DefTitle ="GUFB" 001007 DescSize =0x10B 001006 Desc ="Covers A9L, A9M, A3M, A3M1, A3M2, D3D1, S0Z and X3Z ecu's. Requires 64k bin file, first 8k to be 'padded' with null data .If you find any errors, or can add anything new, please post a topic on the Ford definition forum at http://forum.tunerpro.net/viewforum.php?f=8" 001010 Author ="" 001030 BinSize =0x10000 001035 BaseOffset =0 001200 ADSAssoc ="" 001225 ADSCheck =0x0 001300 GenFlags =0x0 001325 ModeFlags =0x0 002000 Category0 ="Fuel" 002001 Category1 ="Spark" 002002 Category2 ="Sensors" 002003 Category3 ="Limits" 002004 Category4 ="Miscellaneous" 002005 Category5 ="Idle" 002006 Category6 ="Hardware" 002007 Category7 ="Scalers" 002008 Category8 ="Tests" 002009 Category9 ="Adaptive Learning" 002010 Category10 ="Failure Management" 002011 Category11 ="EGR" 002012 Category12 ="Purge" 002013 Category13 ="Accessories" 002014 Category14 ="Economy Mode" 002015 Category15 ="Transmission" 002016 Category16 ="Cruise Control" 002017 Category17 ="Transient Fuel" 002019 Category19 ="Unknown" %%END%% %%CONSTANT%% 000002 UniqueID =0x6182 000100 Cat0ID =0xE 020005 Title ="A/C Clutch Engage Max Temp" 020011 DescSize =0x5 020010 Desc ="CTAC" 020020 Units ="deg F" 020100 Address =0x9402 020150 Flags =0x1 020200 Equation =X*2,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x4653 000100 Cat0ID =0xE 020005 Title ="A/C Clutch Engage Max Temp Hysteresis" 020011 DescSize =0x6 020010 Desc ="CTACH" 020020 Units ="deg F" 020100 Address =0x9403 020150 Flags =0x1 020200 Equation =X*2,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0xEDA 000100 Cat0ID =0xE 020005 Title ="A/C Clutch Engage Min RPM" 020011 DescSize =0x7 020010 Desc ="ACOFFN" 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x9404 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x2B7B 000100 Cat0ID =0xE 020005 Title ="A/C Clutch Engage Min RPM Hysteresis" 020011 DescSize =0x7 020010 Desc ="ACOFFH" 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x9406 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x5960 000100 Cat0ID =0xE 020005 Title ="A/C Clutch Idle Engage Delay Time" 020011 DescSize =0x7 020010 Desc ="IDLCOT" 020020 Units ="secs" 020050 SizeInBits =0x10 020100 Address =0x9400 020150 Flags =0x2 020200 Equation =X/1024,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x7FD3 000100 Cat0ID =0xE 020005 Title ="A/C Clutch Min Disable Time" 020011 DescSize =0x7 020010 Desc ="ACMNDT" 020020 Units ="secs" 020050 SizeInBits =0x10 020100 Address =0x93FE 020150 Flags =0x2 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x508A 000100 Cat0ID =0xE 020005 Title ="A/C Clutch Min Enable Time" 020011 DescSize =0x7 020010 Desc ="ACMNET" 020020 Units ="secs" 020050 SizeInBits =0x10 020100 Address =0x940C 020150 Flags =0x2 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x29D6 000100 Cat0ID =0xE 020005 Title ="A/C Disable Time After Start" 020011 DescSize =0x51 020010 Desc ="ACSTRD - The maximum time that the aircon clutch is disabled for after start up." 020020 Units ="secs" 020100 Address =0x93FB 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x5908 000100 Cat0ID =0xE 020005 Title ="A/C Disable Time Due to Brake" 020011 DescSize =0xA4 020010 Desc ="BRKCOT - The maximum time that the aircon clutch is disabled for when the brake is applied. Set to zero to eliminate the brake having any effect on aircon control." 020020 Units ="secs" 020100 Address =0x93FC 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x24CA 000100 Cat0ID =0x7 020005 Title ="A/C Low Speed Fan MPH" 020011 DescSize =0x5F 020010 Desc ="LSFVS - The minimum mph to turn off the low speed fan when it is being used for the a/c alone." 020020 Units ="mph" 020100 Address =0x9417 020200 Equation =X/2,TH|0|0|0|0| 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x1BB0 000100 Cat0ID =0x7 020005 Title ="A/C Low Speed Fan MPH Hysteresis" 020011 DescSize =0x21 020010 Desc ="LSFVSH - Typically set to 5 mph." 020020 Units ="mph" 020100 Address =0x9418 020200 Equation =X/2,TH|0|0|0|0| 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x131B 000100 Cat0ID =0xE 020005 Title ="A/C Min Time Off Before Turning Fan Off" 020011 DescSize =0xCF 020010 Desc ="ACMNFT - The minimum time that the A/C clutch must be disengaged for before the low speed fan is turned off. Used to avoid excessive on/off fan cycling.\r\n\r\nConversion to be determined, value looks too high." 020020 Units ="secs" 020050 SizeInBits =0x10 020100 Address =0x941A 020150 Flags =0x2 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x4BB7 000100 Cat0ID =0xE 020005 Title ="A/C Recognition Time Threshold" 020011 DescSize =0x5 020010 Desc ="ACRT" 020020 Units ="mSecs" 020050 SizeInBits =0x10 020100 Address =0x93B2 020150 Flags =0x2 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x2FF6 000100 Cat0ID =0xE 020005 Title ="A/C WOT Cutout Threshold" 020011 DescSize =0x28 020010 Desc ="THBP4 - Added to closed throttle value." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x9408 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x11D4 000100 Cat0ID =0xE 020005 Title ="A/C WOT Cutout Threshold Hysteresis" 020011 DescSize =0x7 020010 Desc ="THBP4H" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x940A 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x3EB0 000100 Cat0ID =0xE 020005 Title ="A/C WOT Cutout Time" 020011 DescSize =0x40 020010 Desc ="ACWDLY - Duration the A/C clutch is disengaged for when at WOT." 020020 Units ="secs" 020100 Address =0x93FD 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5938 000100 Cat0ID =0x9 020005 Title ="A/F Ratio for Goose Test" 020011 DescSize =0xB 020010 Desc ="V_KNK_FUEL" 020020 Units ="A/F Ratio" 020050 SizeInBits =0x10 020100 Address =0x8F5A 020150 Flags =0x2 020200 Equation =X/32768*14.64,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x4B2D 000100 Cat0ID =0x9 020005 Title ="A/F Ratio for Self Test" 020011 DescSize =0x6 020010 Desc ="VRLAM" 020020 Units ="A/F ratio" 020050 SizeInBits =0x10 020100 Address =0x9E86 020150 Flags =0x2 020200 Equation =X/32768*14.64,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x38A7 000100 Cat0ID =0x9 020005 Title ="A/F Ratio Rich Limit" 020011 DescSize =0x44 020010 Desc ="REQV - Desired A/F ratio is clipped to this limit during self test." 020020 Units ="A/F ratio" 020050 SizeInBits =0x10 020100 Address =0x9E82 020150 Flags =0x2 020200 Equation =X/32768*14.64,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x4D1 000100 Cat0ID =0x9 020005 Title ="A/F Ratio Lean Limit" 020011 DescSize =0x44 020010 Desc ="LEQV - Desired A/F ratio is clipped to this limit during self test." 020020 Units ="A/F ratio" 020050 SizeInBits =0x10 020100 Address =0x9E84 020150 Flags =0x2 020200 Equation =X/32768*14.64,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x114E 000100 Cat0ID =0x1 020005 Title ="Accel Enrichment Global Multiplier" 020011 DescSize =0xAD 020010 Desc ="AEM - A multiplier of the result of the 'Accel Enrichment Fuel' (aka FN1303) table lookup.\r\nMultiplier values less than 1 reduce fuel, values greater than 1 increase fuel." 020020 Units ="multiplier" 020100 Address =0x9002 020200 Equation =X/128,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x1EA2 000100 Cat0ID =0x5 020005 Title ="Accel Enrichment Load Time Constant" 020011 DescSize =0xEA 020010 Desc ="TCAELD - The time constant for the rolling average calculation of the 'Accel Enrichment Load' (aka AELOAD) value.\r\n\r\nLarger time constant values increase the time lag of the value being updated but reduce unwanted transients from it." 020020 Units ="secs" 020050 SizeInBits =0x10 020100 Address =0x97FC 020150 Flags =0x2 020200 Equation =X/1024,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x96E 000100 Cat0ID =0x1 020005 Title ="Accel Enrichment Minimum" 020011 DescSize =0x31 020010 Desc ="MINAE\r\n\r\nDoes not appear to be used in this ecu." 020020 Units ="lb/min" 020050 SizeInBits =0x10 020100 Address =0x9AA6 020150 Flags =0x2 020200 Equation =X/262144,TH|0|0|0|0| 020210 DecimalPl =0x6 %%END%% %%CONSTANT%% 000002 UniqueID =0x527F 000100 Cat0ID =0x1 020005 Title ="Accel Enrichment Min Delta Load" 020011 DescSize =0x51 020010 Desc ="AEACLD - The change in load required to indicate the intake manifold is filling." 020020 Units ="load" 020050 SizeInBits =0x10 020100 Address =0x9008 020150 Flags =0x3 020200 Equation =X/327.68,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x5544 000100 Cat0ID =0x1 020005 Title ="Accel Enrichment Min Throttle Rate" 020011 DescSize =0x67 020010 Desc ="AETAR - The rate of throttle change must be greater than this value to enable acceleration enrichment." 020020 Units ="deg/sec" 020100 Address =0x900A 020200 Equation =X/2,TH|0|0|0|0| 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x52DD 000100 Cat0ID =0x11 020005 Title ="Acceleration Button Maximum" 020011 DescSize =0x5D 020010 Desc ="HACCEL - Highest value of Vehicle Speed Control Command Switch to indicate button depressed." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8E78 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x7759 000100 Cat0ID =0x11 020005 Title ="Acceleration Button Minimum" 020011 DescSize =0x5C 020010 Desc ="LACCEL - Lowest value of Vehicle Speed Control Command Switch to indicate button depressed." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8E76 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x2C34 000100 Cat0ID =0x11 020005 Title ="Acceleration Ramp Rate" 020011 DescSize =0x4F 020010 Desc ="ACLINC - The rate of acceleration from the current speed to the desired speed." 020020 Units ="mph/sec" 020050 SizeInBits =0x10 020100 Address =0x8E98 020150 Flags =0x2 020200 Equation =X/512,TH|0|0|0|0| 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x556F 000100 Cat0ID =0x1 020005 Title ="ACT Fraction for Accel Enrichment" 020011 DescSize =0x187 020010 Desc ="FRCTAE - The ACT to ECT proportioning factor used to determine the fraction of ACT to ECT for the input value to the 'Accel Enrichment Fuel Scaler for ACT to ECT' (aka FN020B) parameter. Higher values increase the contribution from ACT. Set to zero to run the tables associated with this parameter off ECT alone. Set to 1.000 to run the tables associated with this parameter off ACT alone. " 020020 Units ="multiplier" 020100 Address =0x900B 020200 Equation =X/128,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5BA0 000100 Cat0ID =0x2 020005 Title ="ACT Fraction for Base Dwell" 020011 DescSize =0x1CC 020010 Desc ="DWLWF - The ACT to ECT proportioning factor used to determine the fraction of ACT to ECT for the calculation of the estimated coil temperature value. This estimated value is checked against the 'Dwell Time Table Select Temperature' (aka DWLTMP) parameter. Higher values increase the contribution from ACT. Set to zero to run the tables associated with this parameter off ECT alone. Set to 1.000 to run the tables associated with this parameter off ACT alone. " 020020 Units ="multiplier" 020100 Address =0x945A 020200 Equation =X/128,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5540 000100 Cat0ID =0x12 020005 Title ="ACT Fraction for Transient Fuel" 020011 DescSize =0x174 020010 Desc ="ALPHA - The ACT to ECT proportioning factor used to determine the fraction of ACT to ECT for the input value to the 'Fuel Scaler for ACT to ECT' (aka FN022) parameter. Higher values increase the contribution from ACT. Set to zero to run the tables associated with this parameter off ECT alone. Set to 1.000 to run the tables associated with this parameter off ACT alone. " 020020 Units ="multiplier" 020100 Address =0x9000 020200 Equation =X/128,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x35AA 000100 Cat0ID =0x1 020005 Title ="ACT Fraction for Fuel Base Table" 020011 DescSize =0x175 020010 Desc ="FRCBFT - The ACT to ECT proportioning factor used to determine the fraction of ACT to ECT for the input value to the 'Fuel Scaler for ACT to ECT' (aka FN022) parameter. Higher values increase the contribution from ACT. Set to zero to run the tables associated with this parameter off ECT alone. Set to 1.000 to run the tables associated with this parameter off ACT alone. " 020020 Units ="multiplier" 020100 Address =0x9AB3 020200 Equation =X/128,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5296 000100 Cat0ID =0x1 020005 Title ="ACT Fraction for Fuel Startup Table" 020011 DescSize =0x175 020010 Desc ="FRCSFT - The ACT to ECT proportioning factor used to determine the fraction of ACT to ECT for the input value to the 'Fuel Scaler for ACT to ECT' (aka FN022) parameter. Higher values increase the contribution from ACT. Set to zero to run the tables associated with this parameter off ECT alone. Set to 1.000 to run the tables associated with this parameter off ACT alone. " 020020 Units ="multiplier" 020100 Address =0x9AB4 020200 Equation =X/128,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x7A52 000100 Cat0ID =0x1 020005 Title ="ACT Fraction for Spark" 020011 DescSize =0x35 020010 Desc ="FRCSPK - \r\n\r\nDoes not appear to be used in this ecu." 020020 Units ="multiplier" 020100 Address =0x9441 020200 Equation =X/128,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%TABLE%% 000002 UniqueID =0x445B 000100 Cat0ID =0xE 000101 Cat1ID =0xFF 040005 Title ="A/C WOT Cutout Time vs TP" 040011 DescSize =0x6D 040010 Desc ="FN087 - The maximum time the A/C clutch is disengaged at WOT. The input value is relative throttle position." 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x300 040200 ZEq =X,TH|0|0|0|0| 040304 YOutType =0x2 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x6 040305 Cols =0x1 040320 XUnits ="volts" 040325 YUnits ="secs" 040330 ZUnits ="" 040350 XLabels =X,Y 040352 XLabelType =0x4 040354 XEq =X/12800,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X,TH|0|0|0|0| 040600 XAddress =0x8D56 040650 XOutputDig =0x3 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x8D58 040750 YOutputDig =0x1 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%CONSTANT%% 000002 UniqueID =0x6D2D 000100 Cat0ID =0x9 020005 Title ="ACT KOEO Max" 020011 DescSize =0x7 020010 Desc ="VIACT2" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8F4A 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x3442 000100 Cat0ID =0x9 020005 Title ="ACT KOEO Min" 020011 DescSize =0x7 020010 Desc ="VIACT1" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8F48 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x29F0 000100 Cat0ID =0x9 020005 Title ="ACT KOER Max" 020011 DescSize =0x7 020010 Desc ="VIACT4" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8F4E 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x2C28 000100 Cat0ID =0x9 020005 Title ="ACT KOER Min" 020011 DescSize =0x7 020010 Desc ="VIACT3" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8F4C 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x7563 000100 Cat0ID =0x4 020005 Title ="ACT Max" 020011 DescSize =0x53 020010 Desc ="ACTMAX - Value at which the eec considers that the sensor has failed open circuit." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8EC4 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5153 000100 Cat0ID =0x4 020005 Title ="ACT Min" 020011 DescSize =0x54 020010 Desc ="ACTMIN - Value at which the eec considers that the sensor has failed short circuit." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8EC2 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x362D 000100 Cat0ID =0x12 020005 Title ="Actual Intake Surface Fuel Multiplier" 020011 DescSize =0x61 020010 Desc ="AISFM - Multiplier of 'Actual_Intake_Surface_Fuel' (aka AISF) during deceleration fuel shut off." 020020 Units ="multiplier" 020100 Address =0x9AC2 020200 Equation =X/128,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x4F4D 000100 Cat0ID =0xA 020005 Title ="Adaptive Control Accel Enrichment Max" 020011 DescSize =0x69 020010 Desc ="AELIM - The maximum acceleration enrichment fuel flow permitted in order for adaptive learning to occur." 020020 Units ="lb/min" 020050 SizeInBits =0x10 020100 Address =0x9AF0 020150 Flags =0x2 020200 Equation =X/512,TH|0|0|0|0| 020210 DecimalPl =0x5 %%END%% %%CONSTANT%% 000002 UniqueID =0x61CC 000100 Cat0ID =0xA 020005 Title ="Adaptive Control ACT Max" 020011 DescSize =0x7 020010 Desc ="AFACT2" 020020 Units ="deg F" 020100 Address =0x9AE5 020200 Equation =X*2,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x619D 000100 Cat0ID =0xA 020005 Title ="Adaptive Control ACT Min" 020011 DescSize =0x7 020010 Desc ="AFACT1" 020020 Units ="deg F" 020100 Address =0x9AE4 020200 Equation =X*2,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x4DA7 000100 Cat0ID =0xA 020005 Title ="Adaptive Control Deadband" 020011 DescSize =0x335 020010 Desc ="DELAMB - This value is used to form the deadband around stoichiometric within which the adaptive learning loop counter values are not altered.\r\n\r\nWhen the HEGO is reporting a rich condition this parameter's value is added to the resultant value created by adding the HEGO Bias value to the stoichiometric A/F ratio to establish a lean A/F ratio which if greater than the lean 'Desired A/F Ratio' (aka LAMBSE) value being commanded then the loop counter incrementing does not occur.\r\n\r\nWhen the HEGO is reporting a lean condition this parameter's value is subtracted from the resultant value created by adding the HEGO Bias value to the stoichiometric A/F ratio to establish a rich A/F ratio which if less than the rich 'Desired A/F Ratio' (aka LAMBSE) value being commanded then loop counter incrementing does not occur." 020020 Units ="A/F ratio" 020050 SizeInBits =0x10 020100 Address =0x9AE8 020150 Flags =0x2 020200 Equation =X/32768*14.64,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x2274 000100 Cat0ID =0xA 020005 Title ="Adaptive Control Delay Time" 020011 DescSize =0xCD 020010 Desc ="ADAPTM - The time delay before adaptive learning is permitted once the ECT is between the values set by the 'Adaptive Control ECT Min' (aka AFECT1) and 'Adaptive Control ECT Max' (aka AFECT2) parameters." 020020 Units ="secs" 020050 SizeInBits =0x10 020100 Address =0x9AE6 020150 Flags =0x2 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x2AF1 000100 Cat0ID =0xA 020005 Title ="Adaptive Control ECT Max" 020011 DescSize =0xBD 020010 Desc ="AFECT2 - Temperature at which the 'Adaptive Fuel Timer' (aka ADPTMR) is reset to zero.\r\n\r\nSee 'Adaptive Control Delay Time' (aka ADAPTM) for more information on how this parameter is used." 020020 Units ="deg F" 020100 Address =0x9AE3 020200 Equation =X*2,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x3DA 000100 Cat0ID =0xA 020005 Title ="Adaptive Control ECT Min" 020011 DescSize =0xB8 020010 Desc ="AFECT1 - Temperature at which the 'Adaptive Fuel Timer' (aka ADPTMR) is started.\r\n\r\nSee 'Adaptive Control Delay Time' (aka ADAPTM) for more information on how this parameter is used." 020020 Units ="deg F" 020100 Address =0x9AE2 020200 Equation =X*2,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x6265 000100 Cat0ID =0xA 020005 Title ="Adaptive Control Fast HEGO Count" 020011 DescSize =0xE8 020010 Desc ="FAEGCT - The minimum number of HEGO counts required for adaptive learning to take place when the number of KAM warm ups is less than the 'Adaptive Control Max Warm Up Cycles' value. Lower values increase the adaptive learning rate." 020020 Units ="counts" 020100 Address =0x9AF7 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x68D7 000100 Cat0ID =0xA 020005 Title ="Adaptive Control Max" 020011 DescSize =0x39 020010 Desc ="MAXADP - The maximum value that KAMREF is allowed to be." 020020 Units ="multiplier" 020100 Address =0x9AEF 020150 Flags =0x8 020200 Equation =(X/256)+0.5,TH|0|0|0|0| 020210 DecimalPl =0x3 020240 RangeHigh =128.0000 %%END%% %%CONSTANT%% 000002 UniqueID =0x6266 000100 Cat0ID =0xA 020005 Title ="Adaptive Control Max Warm Up Cycles" 020011 DescSize =0x91 020010 Desc ="KWUCNT - The maximum number of warm up cycles to use the faster adaptive learning update rate. Beyond this value the normal update rate is used." 020020 Units ="no." 020100 Address =0x9AF8 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x4904 000100 Cat0ID =0xA 020005 Title ="Adaptive Control Min" 020011 DescSize =0x39 020010 Desc ="MINADP - The minimum value that KAMREF is allowed to be." 020020 Units ="multiplier" 020100 Address =0x9AEE 020150 Flags =0x8 020200 Equation =(X/256)+0.5,TH|0|0|0|0| 020210 DecimalPl =0x3 020240 RangeHigh =128.0000 %%END%% %%CONSTANT%% 000002 UniqueID =0x44DB 000100 Cat0ID =0xA 020005 Title ="Adaptive Control Table Column Lockout" 020011 DescSize =0x124 020010 Desc ="DELCOL - If the difference between the current adaptive control learning table column (aka NRMCES) and the last adaptive control learning table column (aka LSTCOL) is greater than this value then adaptive learning is disabled. Used to reduce the effect of excessive transient changes in rpm." 020020 Units ="column" 020050 SizeInBits =0x10 020100 Address =0x9AEC 020150 Flags =0x2 020200 Equation =X/256,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x40E3 000100 Cat0ID =0xA 020005 Title ="Adaptive Control Table Row Lockout" 020011 DescSize =0x11F 020010 Desc ="DELROW - If the difference between the current adaptive control learning table row (aka NRMRLD) and the last adaptive control learning table row (aka LSTROW) is greater than this value then adaptive learning is disabled. Used to reduce the effect of excessive transient changes in load." 020020 Units ="row" 020050 SizeInBits =0x10 020100 Address =0x9AEA 020150 Flags =0x2 020200 Equation =X/256,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x46B4 000100 Cat0ID =0xA 020005 Title ="Adaptive Control Normal HEGO Count" 020011 DescSize =0xB9 020010 Desc ="ADEGCT - The minimum number of HEGO counts required for adaptive learning to take place when the number of KAM warm ups is greater than the 'Adaptive Control Max Warm Up Cycles' value." 020020 Units ="counts" 020100 Address =0x9AF6 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x285A 000100 Cat0ID =0xA 020005 Title ="Adaptive Control Transient Fuel Max" 020011 DescSize =0x6E 020010 Desc ="ADEFTR - The maximum transient fuel compensation fuel flow permitted in order for adaptive learning to occur." 020020 Units ="lb/min" 020050 SizeInBits =0x10 020100 Address =0x9AF4 020150 Flags =0x3 020200 Equation =X/65536,TH|0|0|0|0| 020210 DecimalPl =0x6 %%END%% %%CONSTANT%% 000002 UniqueID =0x596F 000100 Cat0ID =0xE 020005 Title ="Adjustable Damper Min Air Charge" 020011 DescSize =0x3F 020010 Desc ="SHKCHG - The minimum air charge to indicate hard acceleration." 020020 Units ="lb/intake" 020050 SizeInBits =0x10 020100 Address =0x9410 020150 Flags =0x2 020200 Equation =X/16777216,TH|0|0|0|0| 020210 DecimalPl =0x7 %%END%% %%CONSTANT%% 000002 UniqueID =0x7EE9 000100 Cat0ID =0xE 020005 Title ="Adjustable Damper Min TP" 020011 DescSize =0x51 020010 Desc ="SHKTP - The minimum voltage above closed throttle to indicate hard acceleration." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x9412 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x5599 000100 Cat0ID =0xB 020005 Title ="Airmass Flow Min For TP Calculation" 020011 DescSize =0xCE 020010 Desc ="IDLMAF - If the airmass is less than this then the eec sets the throttle value equal to the closed throttle value if either the TPS has failed, is less than 'TPS Max' value or greater than 'TPS Max' value." 020020 Units ="lb/min" 020050 SizeInBits =0x10 020100 Address =0x942C 020150 Flags =0x2 020200 Equation =X/1024,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x45FE 000100 Cat0ID =0xA 020005 Title ="Allow Adaptive Learning" 020011 DescSize =0xA8 020010 Desc ="Z_ADPSW - Set to \"4700\" to permit adaptive learning to occur, change to \"480F\" to disable adaptive learning.\r\n\r\nWARNING: Do not use any values other than one of these." 020020 Units ="" 020050 SizeInBits =0x10 020100 Address =0x21B4 020150 Flags =0x2 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x3 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x4D2A 000100 Cat0ID =0x9 020005 Title ="Allow MIL Bulb Check" 020011 DescSize =0x6E 020010 Desc ="MILLIM - Setting to any value other than zero will permit the MIL bulb check to be performed during cranking." 020020 Units ="n/a" 020050 SizeInBits =0x10 020100 Address =0x8F74 020150 Flags =0x2 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5186 000100 Cat0ID =0xE 020005 Title ="Alternator Control Cold Start Delay #1" 020011 DescSize =0x6 020010 Desc ="EDTM1" 020020 Units ="secs" 020100 Address =0x93EB 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x387B 000100 Cat0ID =0xE 020005 Title ="Alternator Control Cold Start Delay #2" 020011 DescSize =0x6 020010 Desc ="EDTM4" 020020 Units ="secs" 020100 Address =0x93EC 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x7A57 000100 Cat0ID =0xE 020005 Title ="Alternator Control Hot Start Delay" 020011 DescSize =0x6 020010 Desc ="EDTM3" 020020 Units ="secs" 020100 Address =0x93E8 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x57C5 000100 Cat0ID =0xE 020005 Title ="Alternator Control Max Temp" 020011 DescSize =0x57 020010 Desc ="ECADECT - Below this temperature the alternator may be permitted to run at half speed." 020020 Units ="deg F" 020100 Address =0x93E2 020200 Equation =X*2,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x55B0 000100 Cat0ID =0xE 020005 Title ="Alternator Control Max Temp Hysteresis" 020011 DescSize =0x4A 020010 Desc ="EDETHYS - Hysteresis value subtracted from 'Alternator Control Max Temp'." 020020 Units ="deg F" 020100 Address =0x93E5 020150 Flags =0x1 020200 Equation =X*2,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x858 000100 Cat0ID =0xE 020005 Title ="Alternator Control Min MPH" 020011 DescSize =0x5B 020010 Desc ="ECADVS - The minimum mph required for the alternator to be permitted to run at half speed." 020020 Units ="mph" 020100 Address =0x93E4 020200 Equation =X/2,TH|0|0|0|0| 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x42E5 000100 Cat0ID =0xE 020005 Title ="Alternator Control Min MPH Hysteresis" 020011 DescSize =0x60 020010 Desc ="EDVSHYS - Hysteresis value subtracted from 'Alternator Control Min MPH' (aka ECADVS) parameter." 020020 Units ="mph" 020100 Address =0x93E7 020200 Equation =X/2,TH|0|0|0|0| 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x6CD1 000100 Cat0ID =0xE 020005 Title ="Alternator Control Min RPM" 020011 DescSize =0x5A 020010 Desc ="ECADN - The minimum rpm required for the alternator to be permitted to run at half speed." 020020 Units ="rpm" 020100 Address =0x93E3 020200 Equation =X*16,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x7C01 000100 Cat0ID =0xE 020005 Title ="Alternator Control Min RPM Hysteresis" 020011 DescSize =0x5E 020010 Desc ="EDNHYS - Hysteresis value subtracted from 'Alternator Control Min RPM' (aka ECADN) parameter." 020020 Units ="rpm" 020100 Address =0x93E6 020200 Equation =X*16,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x6B94 000100 Cat0ID =0xE 020005 Title ="Alternator Control Warm Start Delay #1" 020011 DescSize =0x6 020010 Desc ="EDTM2" 020020 Units ="secs" 020100 Address =0x93E9 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x2369 000100 Cat0ID =0xE 020005 Title ="Alternator Control Warm Start Delay #2" 020011 DescSize =0x6 020010 Desc ="EDTM5" 020020 Units ="secs" 020100 Address =0x93EA 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x24BA 000100 Cat0ID =0x9 020005 Title ="AM2 Open Circuit Check" 020011 DescSize =0xA 020010 Desc ="OCCDT1 - " 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8F7C 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x5C4 000100 Cat0ID =0x9 020005 Title ="AM1 Open Circuit Check" 020011 DescSize =0xA 020010 Desc ="OCCDT2 - " 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8F7E 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5E0B 000100 Cat0ID =0x7 020005 Title ="Auxiliary Hardware Present" 020011 DescSize =0xD0 020010 Desc ="THRMHP - The four possible settings are;\r\n\r\n0 = None of the following hardware is present\r\n1 = Thermactor hardware present\r\n2 = Supercharger bypass valve present\r\n3 = Inlet manifold air control valve present" 020020 Units ="" 020100 Address =0x9E65 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x3492 000100 Cat0ID =0x9 020005 Title ="Battery Voltage Lower Limit" 020011 DescSize =0xA 020010 Desc ="VKYPWR - " 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8EAC 020150 Flags =0x2 020200 Equation =X/1024,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x6130 000100 Cat0ID =0x5 020005 Title ="Battery Voltage Time Constant" 020011 DescSize =0xE2 020010 Desc ="TCVBAT - The time constant for the rolling average calculation of the 'Battery Voltage' (aka VBAT) value.\r\n\r\nLarger time constant values increase the time lag of the value being updated but reduce unwanted transients from it." 020020 Units ="secs" 020050 SizeInBits =0x10 020100 Address =0x97F8 020150 Flags =0x2 020200 Equation =X/1024,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x6B6E 000100 Cat0ID =0x9 020005 Title ="BP Max During Test" 020011 DescSize =0x7 020010 Desc ="VBPDL2" 020020 Units ="clock ticks" 020050 SizeInBits =0x10 020100 Address =0x8F5E 020150 Flags =0x2 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0xC47 000100 Cat0ID =0x9 020005 Title ="BP Max Time Between Update" 020011 DescSize =0x7 020010 Desc ="VBPMAX" 020020 Units ="secs" 020100 Address =0x8F70 020200 Equation =X/1024,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x3AF5 000100 Cat0ID =0x9 020005 Title ="BP Min During Test" 020011 DescSize =0x7 020010 Desc ="VBPDL1" 020020 Units ="clock ticks" 020050 SizeInBits =0x10 020100 Address =0x8F5C 020150 Flags =0x2 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x60A6 000100 Cat0ID =0x3 020005 Title ="BP Time Constant" 020011 DescSize =0xF2 020010 Desc ="TCBBAR - The time constant for the rolling average calculation of the 'BP' (aka BP) and 'BP Average' (aka BAPBAR) values.\r\n\r\nLarger time constant values increase the time lag of the value being updated but reduce unwanted transients from it." 020020 Units ="secs" 020050 SizeInBits =0x10 020100 Address =0x97FE 020150 Flags =0x2 020200 Equation =X/1024,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x530D 000100 Cat0ID =0x11 020005 Title ="Buttons Not Pressed Maximum" 020011 DescSize =0x60 020010 Desc ="HIHOLD - Highest value of Vehicle Speed Control Command Switch to indicate no button depressed." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8E80 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x52E0 000100 Cat0ID =0x11 020005 Title ="Buttons Not Pressed Minimum" 020011 DescSize =0x5F 020010 Desc ="LOHOLD - Lowest value of Vehicle Speed Control Command Switch to indicate no button depressed." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8E7E 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0xF37 000100 Cat0ID =0x6 020005 Title ="Buzz RPM" 020011 DescSize =0x53 020010 Desc ="BZZRPM - Additional rpm added to base target idle rpm at start up to clear engine." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x904E 020150 Flags =0x2 020200 Equation =X*8,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x6BCB 000100 Cat0ID =0x6 020005 Title ="Buzz RPM Time" 020011 DescSize =0x7C 020010 Desc ="BZZTM - Duration that 'Buzz RPM' (aka BZZRPM) is added to base target idle rpm at startup. \r\n\r\nConversion to be determined." 020020 Units ="secs" 020100 Address =0x9067 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x56A5 000100 Cat0ID =0x1 020005 Title ="C/L Neutral Idle Fuel Max Time" 020011 DescSize =0xE9 020010 Desc ="NIOLD - If the 'Close Throttle Neutral Timer' (aka CTNTMR) exceeds this value then open loop mode is used when in neutral at idle. This value is only checked by the eec when at closed throttle. Set to '255' to disable this function." 020020 Units ="secs" 020100 Address =0x9048 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x3E9E 000100 Cat0ID =0x9 020005 Title ="Canister Purge Open Circuit Check" 020011 DescSize =0xA 020010 Desc ="OCCDT5 - " 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8F84 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x13DF 000100 Cat0ID =0xD 020005 Title ="Canister Purge Min RPM" 020011 DescSize =0x44 020010 Desc ="EVRPM - \r\n\r\nDoes not appear to be used by the eec in this strategy." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x93F2 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x6A19 000100 Cat0ID =0xD 020005 Title ="Canister Purge Min RPM Hysteresis" 020011 DescSize =0x45 020010 Desc ="EVRPMH - \r\n\r\nDoes not appear to be used by the eec in this strategy." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x93F4 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x131E 000100 Cat0ID =0x5 020005 Title ="Checksum" 020011 DescSize =0x9F 020010 Desc ="CHKSUM - Do not edit. This is recalculated automatically when the bin is saved. When emulating, upload this new checksum to the emulator after saving the bin." 020020 Units ="" 020050 SizeInBits =0x10 020100 Address =0x200A 020150 Flags =0x2 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x7F06 000100 Cat0ID =0xA 020005 Title ="Clear KAM" 020011 DescSize =0x1C6 020010 Desc ="Z_KAMCLR - Forces the re-initialisation of the Keep Alive Memory so that all adaptive learning information is cleared.\r\n\r\nNormally set to \"235D\", change this to \"2382\" to clear the KAM (either during running if your emulator permits 'on the fly' changes or by cycling the key to 'run' and then off) and then restore back to the original value. Does not affect the KAM during KOEO or KEOR tests.\r\n\r\nWARNING: Do not use any values other than one of these." 020020 Units ="" 020050 SizeInBits =0x10 020100 Address =0x218C 020150 Flags =0x2 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x52DB 000100 Cat0ID =0x11 020005 Title ="Coast Button Maximum" 020011 DescSize =0x5D 020010 Desc ="HCOAST - Highest value of Vehicle Speed Control Command Switch to indicate button depressed." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8E74 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x52DA 000100 Cat0ID =0x11 020005 Title ="Coast Button Minimum" 020011 DescSize =0x5C 020010 Desc ="LCOAST - Lowest value of Vehicle Speed Control Command Switch to indicate button depressed." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8E72 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x32B1 000100 Cat0ID =0x1 020005 Title ="Cold Engine Fuel Multiplier Update Time Limit" 020011 DescSize =0xEC 020010 Desc ="MULTM - When the 'Cold Engine Fuel Multiplier Update Timer' (aka MULTMR) exceeds this value then the 'Cold Engine Fuel Multiplier' (aka LAMMUL) value is updated.\r\n\r\nDoes not appear to be used in this ecu, possibly superseded by FN393F." 020020 Units ="secs" 020100 Address =0x9AF9 020150 Flags =0x8 020200 Equation =X/1024,TH|0|0|0|0| 020210 DecimalPl =0x3 020240 RangeHigh =128.0000 %%END%% %%CONSTANT%% 000002 UniqueID =0x3367 000100 Cat0ID =0x5 020005 Title ="Cold Start Max ECT" 020011 DescSize =0x45 020010 Desc ="CTLOW - The maximum ECT for a cold start condition to be recognised." 020020 Units ="deg F" 020100 Address =0x9E5F 020150 Flags =0x1 020200 Equation =X*2,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x6082 000100 Cat0ID =0x5 020005 Title ="Cranking Mode Exit Min PIPs" 020011 DescSize =0xD7 020010 Desc ="NCNT - Once the ECT sensor has been read 8 times this is the minimum number of PIPs that must occur once the rpm is greater than the 'Cranking Mode Exit Min RPM' (aka NRUN) parameter in order to exit cranking mode." 020020 Units ="no." 020100 Address =0x97BC 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x5D9D 000100 Cat0ID =0x5 020005 Title ="Cranking Mode Exit RPM" 020011 DescSize =0xC2 020010 Desc ="NRUN - Once the ECT sensor has been read 8 times this is the minimum rpm required for the 'Cranking Mode Exit Min PIPs' (aka NCNT) parameter to be checked to see if cranking mode can be exited." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x97C2 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x128C 000100 Cat0ID =0x5 020005 Title ="Cranking Mode Re-enter RPM" 020011 DescSize =0x4E 020010 Desc ="NSTALL - If the rpm is less than this value then cranking mode is re-entered." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x97C4 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x34AF 000100 Cat0ID =0x2 020005 Title ="Cranking Mode Spark" 020011 DescSize =0x137 020010 Desc ="Z_CRKSPK - The spark advance used during cranking. Adjust for highly modified engines that will not start with the stock advance value of 10 degrees.\r\n\r\nRequires the use of a \"black\" Computer Controlled Dwell (CCD) TFI module and the 'Computer Controlled Dwell Present' (aka CCDSW) parameter needs to be set.\r\n" 020020 Units ="deg adv" 020100 Address =0x55CA 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x56A6 000100 Cat0ID =0x1 020005 Title ="CT Neutral Timer Hysteresis" 020011 DescSize =0x84 020010 Desc ="NIHYS - Added to 'C/L Neutral Idle Fuel Max Time' to make the upper clip limit of the 'Closed Throttle Neutral Timer' (aka CTNTMR)." 020020 Units ="secs" 020100 Address =0x9049 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x583C 000100 Cat0ID =0x5 020005 Title ="CT Neutral Timer Max RPM" 020011 DescSize =0xF3 020010 Desc ="INLRPM - The base rpm added to the result of the 'CT Neutral Timer RPM Adder' (aka FN880) lookup. This resultant value is the maximum rpm allowed in order for the 'CT Neutral Timer' to count up and the 'CT Neutral Flag (aka CTNFLG) to be set." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x93DA 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x7C1 000100 Cat0ID =0x5 020005 Title ="CT Neutral Timer Max RPM Hysteresis" 020011 DescSize =0x4B 020010 Desc ="INLRPH - Hysteresis for the 'CT Neutral Timer Max RPM' (aka INLRPM) value." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x93DC 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x5C04 000100 Cat0ID =0x2 020005 Title ="CT Tip In Flag Min Load" 020011 DescSize =0x56 020010 Desc ="TIPLOD - The minimum load in order for the closed throttle tip in flag to be cleared." 020020 Units ="load" 020050 SizeInBits =0x10 020100 Address =0x9464 020150 Flags =0x2 020200 Equation =X/327.68,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x257B 000100 Cat0ID =0x2 020005 Title ="CT Tip In Flag Min Load Hysteresis" 020011 DescSize =0x3D 020010 Desc ="TIPHYS - Hysteresis for the 'CT Tip In Flag Min Load' value." 020020 Units ="load" 020050 SizeInBits =0x10 020100 Address =0x9466 020150 Flags =0x2 020200 Equation =X/327.68,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x2B9F 000100 Cat0ID =0x9 020005 Title ="CT to PT Transitions to Enable HEGO Switch Test" 020011 DescSize =0x7 020010 Desc ="VPTCNT" 020020 Units ="no." 020100 Address =0x8F01 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x5A6E 000100 Cat0ID =0x2 020005 Title ="CT Spark Adder" 020011 DescSize =0x30 020010 Desc ="KCS1 - Added to 'CT Spark vs RPM' lookup value." 020020 Units ="deg adv" 020050 SizeInBits =0x10 020100 Address =0x9432 020150 Flags =0x3 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x35EF 000100 Cat0ID =0x9 020005 Title ="Cylinder Balance Test Desired AF Ratio" 020011 DescSize =0x7 020010 Desc ="VLAMCB" 020020 Units ="AF ratio" 020050 SizeInBits =0x10 020100 Address =0x8EF4 020150 Flags =0x2 020200 Equation =X/32768*14.64,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x7D76 000100 Cat0ID =0x9 020005 Title ="Cylinder Balance Test Desired RPM" 020011 DescSize =0xA 020010 Desc ="VISCN1 - " 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x8EF6 020150 Flags =0x2 020200 Equation =X*8,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x1CA8 000100 Cat0ID =0x9 020005 Title ="Cylinder Balance Test Injector Off Time" 020011 DescSize =0x7 020010 Desc ="VCBTM2" 020020 Units ="secs" 020100 Address =0x8EFD 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x3D8A 000100 Cat0ID =0x9 020005 Title ="Cylinder Balance Test Injector On Time" 020011 DescSize =0x7 020010 Desc ="VCBTM1" 020020 Units ="secs" 020100 Address =0x8EFC 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x4A03 000100 Cat0ID =0x9 020005 Title ="Cylinder Balance Test RPM Drop" 020011 DescSize =0x7 020010 Desc ="VCBPCT" 020020 Units ="%" 020050 SizeInBits =0x10 020100 Address =0x8EF2 020150 Flags =0x2 020200 Equation =X/327.68,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x7730 000100 Cat0ID =0x9 020005 Title ="Cylinder Balance Test RPM Drop Clip" 020011 DescSize =0x7 020010 Desc ="VCBCLP" 020020 Units ="%" 020050 SizeInBits =0x10 020100 Address =0x8EEE 020150 Flags =0x2 020200 Equation =X/327.68,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x1BC6 000100 Cat0ID =0x9 020005 Title ="Cylinder Balance Test RPM Drop Increment" 020011 DescSize =0x7 020010 Desc ="VCBPAD" 020020 Units ="%" 020050 SizeInBits =0x10 020100 Address =0x8EF0 020150 Flags =0x2 020200 Equation =X/327.68,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x1B08 000100 Cat0ID =0x9 020005 Title ="Cylinder Balance Test RPM Drop Time" 020011 DescSize =0x7 020010 Desc ="VISDL5" 020020 Units ="secs" 020100 Address =0x8EFB 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x540 000100 Cat0ID =0x9 020005 Title ="Cylinder Balance Test Start Delay" 020011 DescSize =0x7 020010 Desc ="VCBDLY" 020020 Units ="secs" 020100 Address =0x8EF8 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x377C 000100 Cat0ID =0x9 020005 Title ="Cylinder Balance Test Time Wait" 020011 DescSize =0x7 020010 Desc ="VISDL4" 020020 Units ="secs" 020100 Address =0x8EFA 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x41FF 000100 Cat0ID =0x9 020005 Title ="Cylinder Balance Test Type" 020011 DescSize =0x54 020010 Desc ="VCBFLG -\r\n\r\n-1 = allow test\r\n 0 = inhibit test\r\n 1 = allow multiple entries to test" 020020 Units ="state" 020100 Address =0x8EF9 020150 Flags =0x1 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x5377 000100 Cat0ID =0x6 020005 Title ="Dashpot Min for Declutch" 020011 DescSize =0x12B 020010 Desc ="DASMIN - When at closed throttle this is the minimum dashpot (pre position airflow) allowed when the vehicle speed is greater than the resultant value created by adding the 'Dashpot Min MPH for Declutch' (aka DASMPH) and 'Dashpot Min MPH for Declutch Hysteresis' (aka DASMHYST) parameters together." 020020 Units ="lb/min" 020050 SizeInBits =0x10 020100 Address =0x8EA4 020150 Flags =0x2 020200 Equation =X/4096,TH|0|0|0|0| 020210 DecimalPl =0x6 %%END%% %%CONSTANT%% 000002 UniqueID =0x5375 000100 Cat0ID =0x6 020005 Title ="Dashpot Min MPH for Declutch" 020011 DescSize =0xD6 020010 Desc ="DASMPH - When the 'Dashpot Min for Declutch' (aka DASMIN) parameter is being used by the eec this is the minimum vehicle speed required for this minimum dashpot (pre position airflow) to be continue to be applied." 020020 Units ="mph" 020100 Address =0x8EA2 020200 Equation =X/2,TH|0|0|0|0| 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x5376 000100 Cat0ID =0x6 020005 Title ="Dashpot Min MPH for Declutch Hysteresis" 020011 DescSize =0x55 020010 Desc ="DASMHYST - Hysteresis for the 'Dashpot Min MPH for Declutch' (aka DASMPH) parameter." 020020 Units ="mph" 020100 Address =0x8EA3 020200 Equation =X/2,TH|0|0|0|0| 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x563E 000100 Cat0ID =0x6 020005 Title ="Dashpot Offset" 020011 DescSize =0xA7 020010 Desc ="DASPTO - An offset added to the final dashpot (pre position airflow) value in order to ensure some airflow during tip in or tip out. Typically set around 0.10 lb/min." 020020 Units ="lb/min" 020050 SizeInBits =0x10 020100 Address =0x9034 020150 Flags =0x2 020200 Equation =X/4096,TH|0|0|0|0| 020210 DecimalPl =0x6 %%END%% %%CONSTANT%% 000002 UniqueID =0x563F 000100 Cat0ID =0x6 020005 Title ="Dashpot TP" 020011 DescSize =0xCD 020010 Desc ="DELHYS - Used in the calculation of the dashpot (pre position airflow) value. Set equal to the sum of the following parameters;\r\n\r\n'TPS PT Threshold' (aka DELTA)\r\n'TPS PT Threshold Hysteresis' (aka HYSTS)" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x9036 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x530E 000100 Cat0ID =0x11 020005 Title ="DC Correction Factor" 020011 DescSize =0x7 020010 Desc ="DCBIAS" 020020 Units ="%" 020050 SizeInBits =0x10 020100 Address =0x8E82 020150 Flags =0x2 020200 Equation =X/128,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x26B0 000100 Cat0ID =0x11 020005 Title ="Debounce Time Delay" 020011 DescSize =0x7 020010 Desc ="DEBTIM" 020020 Units ="secs" 020050 SizeInBits =0x10 020100 Address =0x8E8A 020150 Flags =0x2 020200 Equation =X/1024,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x51C8 000100 Cat0ID =0x1 020005 Title ="Decel Fuel Shut Off CT Min Time Delay" 020011 DescSize =0x10A 020010 Desc ="CTDFSO - The minimum time delay required for deceleration fuel shut off to be permitted when the throttle is closed.\r\nSet to less than the 'Decel Fuel Shut Off Time Delay Extension' (aka CTEDSO) value.\r\nNot used if the 'Decel Fuel Shut Off PT Enable' switch is set." 020020 Units ="secs" 020100 Address =0x9ACE 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x788E 000100 Cat0ID =0x1 020005 Title ="Decel Fuel Shut Off Fuel Ramp Back Clip" 020011 DescSize =0x4B 020010 Desc ="DMIN - A clip applied to FN379.\r\n\r\nDoes not appear to be used in this ecu." 020020 Units ="???" 020050 SizeInBits =0x10 020100 Address =0x9AD8 020150 Flags =0x2 020200 Equation =X/128,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x3271 000100 Cat0ID =0x1 020005 Title ="Decel Fuel Shut Off Low Load Timer Run" 020011 DescSize =0x5B 020010 Desc ="DFLDL - The maximum load allowed for the 'Decel Fuel Shut Off Low Load Timer' to count up." 020020 Units ="load" 020050 SizeInBits =0x10 020100 Address =0x9ADC 020150 Flags =0x2 020200 Equation =X/327.68,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x5DB7 000100 Cat0ID =0x1 020005 Title ="Decel Fuel Shut Off Low Load Timer Stop" 020011 DescSize =0x5D 020010 Desc ="DFLDH - The minimum load required for the 'Decel Fuel Shut Off Low Load Timer' to be reset." 020020 Units ="load" 020050 SizeInBits =0x10 020100 Address =0x9ADE 020150 Flags =0x2 020200 Equation =X/327.68,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x137B 000100 Cat0ID =0x1 020005 Title ="Decel Fuel Shut Off Low Load Time" 020011 DescSize =0xA 020010 Desc ="DLDFSO - " 020020 Units ="secs" 020100 Address =0x9AE0 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x4A83 000100 Cat0ID =0x1 020005 Title ="Decel Fuel Shut Off Max Load" 020011 DescSize =0x51 020010 Desc ="DFLOD - The maximum load allowed for deceleration fuel shut off to be permitted." 020020 Units ="load" 020050 SizeInBits =0x10 020100 Address =0x9AC4 020150 Flags =0x2 020200 Equation =X/327.68,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x2FD3 000100 Cat0ID =0x1 020005 Title ="Decel Fuel Shut Off Max Load Hysteresis" 020011 DescSize =0x42 020010 Desc ="DFLODH - Hysteresis for the 'Decel Fuel Shut Off Max Load' value." 020020 Units ="load" 020050 SizeInBits =0x10 020100 Address =0x9AC6 020150 Flags =0x2 020200 Equation =X/327.68,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x73E5 000100 Cat0ID =0x1 020005 Title ="Decel Fuel Shut Off Min ECT" 020011 DescSize =0x9F 020010 Desc ="DFSECT - The minimum ECT required for deceleration fuel shut off to be permitted prior to the 'Decel Fuel Shut Off Time Delay' (aka AGB) value being exceeded." 020020 Units ="deg F" 020100 Address =0x9AC3 020200 Equation =X*2,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x6278 000100 Cat0ID =0x1 020005 Title ="Decel Fuel Shut Off Min MPH" 020011 DescSize =0x5B 020010 Desc ="DFSVS - The minimum vehicle speed required for deceleration fuel shut off to be permitted." 020020 Units ="mph" 020100 Address =0x9ADA 020200 Equation =X/2,TH|0|0|0|0| 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x24A5 000100 Cat0ID =0x1 020005 Title ="Decel Fuel Shut Off Min MPH Hysteresis" 020011 DescSize =0x4D 020010 Desc ="DFSVSH - Hysteresis for the 'Decel Fuel Shut Off Min MPH' (aka DFSVS) value." 020020 Units ="mph" 020100 Address =0x9ADB 020200 Equation =X/2,TH|0|0|0|0| 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x49D0 000100 Cat0ID =0x1 020005 Title ="Decel Fuel Shut Off Min PIP To Remain O/L" 020011 DescSize =0x101 020010 Desc ="PIPNUM - After deceleration fuel shut off has finished this is the number of PIPs that must occur in order to stay in open loop mode. This prevents the desired AF ratio from ramping rich until the HEGO transport delay has passed. Set to 1 to calibrate out." 020020 Units ="pips" 020100 Address =0x9AD1 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x3E3A 000100 Cat0ID =0x1 020005 Title ="Decel Fuel Shut Off Min RPM" 020011 DescSize =0x66 020010 Desc ="DFSRPM - The minimum rpm above the desired idle rpm at which deceleration fuel shut off is permitted." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x9AC8 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x6056 000100 Cat0ID =0x1 020005 Title ="Decel Fuel Shut Off Min RPM Hysteresis" 020011 DescSize =0x4E 020010 Desc ="DFSRPH - Hysteresis for the 'Decel Fuel Shut Off Min RPM' (aka DFSRPM) value." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x9ACA 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x8F5 000100 Cat0ID =0x1 020005 Title ="Decel Fuel Shut Off Min Time at PT" 020011 DescSize =0xC4 020010 Desc ="DSFTM - The minimum time at part or wide open throttle required for deceleration fuel shut off to be permitted after the 'Decel Fuel Shut Off CT Min Time Delay' has occurred.\r\n\r\nNeeds confirming." 020020 Units ="secs" 020100 Address =0x9AD0 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x10B 000100 Cat0ID =0x1 020005 Title ="Decel Fuel Shut Off Neutral Max Time" 020011 DescSize =0x9A 020010 Desc ="DSTM1 - The maximum time that deceleration fuel shut off is permitted during deceleration whilst in neutral.\r\nOnly used if 'Transmission Type' is 2 or 3." 020020 Units ="secs" 020100 Address =0x9ACC 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x186C 000100 Cat0ID =0x1 020005 Title ="Decel Fuel Shut Off Shift Max Time" 020011 DescSize =0x75 020010 Desc ="DSTM2 - The maximum time that deceleration fuel shut off is permitted during gear shifts on manual gearbox vehicles." 020020 Units ="secs" 020100 Address =0x9ACD 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x656 000100 Cat0ID =0x1 020005 Title ="Decel Fuel Shut Off Shift Min RPM" 020011 DescSize =0xAE 020010 Desc ="SHFRPM - The minimum rpm above the 'Desired Idle RPM' (aka DSDRPM) required for the deceleration fuel shut off to be permitted during gear shifts on manual gearbox vehicles." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x9AD4 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x2F 000100 Cat0ID =0x1 020005 Title ="Decel Fuel Shut Off Shift Min RPM Hysteresis" 020011 DescSize =0x54 020010 Desc ="SHFHYS - Hysteresis for the 'Decel Fuel Shut Off Shift Min RPM' (aka SHFRPM) value." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x9AD6 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x3E60 000100 Cat0ID =0x1 020005 Title ="Decel Fuel Shut Off Shift Min TP Hysteresis" 020011 DescSize =0x34 020010 Desc ="TPHYS - \r\n\r\nDoes not appear to be used in this ecu." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x9AD2 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x772 000100 Cat0ID =0x1 020005 Title ="Decel Fuel Shut Off Time Delay" 020011 DescSize =0xC4 020010 Desc ="AGB - The minimum time that must elapse after exiting crank in order for deceleration fuel shut off to be permitted when the ECT is less than the 'Decel Fuel Shut Off Min ECT' (aka DFSECT) value." 020020 Units ="secs" 020100 Address =0x8FE3 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x1D75 000100 Cat0ID =0x1 020005 Title ="Decel Fuel Shut Off Time Extension" 020011 DescSize =0x13E 020010 Desc ="CTEDSO - Used to keep deceleration fuel shut off continuing during long decelerations (such as lengthy descents) even if short tip in/tip out events occur.\r\nSet to greater than the 'Decel Fuel Shut Off CT Min Time Delay' (aka CTDFSO) value.\r\nNot used if the 'Decel Fuel Shut Off PT Enable' (aka PTDFSW) switch is set." 020020 Units ="secs" 020100 Address =0x9ACF 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x3998 000100 Cat0ID =0xB 020005 Title ="Default ACT" 020011 DescSize =0x6C 020010 Desc ="ACTFMM - Default value used for ACT when the ACT sensor has failed and (other conditions to be determined)." 020020 Units ="deg F" 020100 Address =0x9427 020150 Flags =0x1 020200 Equation =X*2,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x182E 000100 Cat0ID =0x5 020005 Title ="Default BAP" 020011 DescSize =0x4E 020010 Desc ="KONBP - Default barometric pressure value used when no BAP sensor is fitted.." 020020 Units ="in Hg" 020100 Address =0x947C 020200 Equation =X/8,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x6F57 000100 Cat0ID =0xB 020005 Title ="Default BAP for Sensor Fail" 020011 DescSize =0x50 020010 Desc ="BAPFMM - Default barometric pressure value used when the BAP sensor has failed." 020020 Units ="in Hg" 020100 Address =0x942E 020200 Equation =X/8,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0xFE6 000100 Cat0ID =0xB 020005 Title ="Default ECT" 020011 DescSize =0x6C 020010 Desc ="ECTFMM - Default value used for ECT when the ECT sensor has failed and (other conditions to be determined)." 020020 Units ="deg F" 020100 Address =0x9428 020150 Flags =0x1 020200 Equation =X*2,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x49DD 000100 Cat0ID =0xB 020005 Title ="Default Desired Idle RPM" 020011 DescSize =0x4E 020010 Desc ="FMMDSD - Default desired idle rpm when both TPS and MAF failed flags are set." 020020 Units ="rpm" 020100 Address =0x9426 020200 Equation =X*16,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x5FF5 000100 Cat0ID =0xB 020005 Title ="Default ISC Dutycycle" 020011 DescSize =0x49 020010 Desc ="FMMISC - Default ISC dutycyle when both TPS and MAF failed flags are set" 020020 Units ="%" 020050 SizeInBits =0x10 020100 Address =0x9424 020150 Flags =0x2 020200 Equation =X/327.68,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x1790 000100 Cat0ID =0xB 020005 Title ="Default TP" 020011 DescSize =0xA6 020010 Desc ="FMCTTP - Added to closed throttle value to give a default throttle value if either the TPS has failed, is less than 'TPS Min' value or greater than 'TPS Max' value." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x942A 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0xFE9 000100 Cat0ID =0x1 020005 Title ="Desired A/F Ratio Max" 020011 DescSize =0x59 020010 Desc ="LAMMAX - The desired A/F ratio is clipped to this limit during closed loop fuel control." 020020 Units ="A/F ratio" 020050 SizeInBits =0x10 020100 Address =0x9AA2 020150 Flags =0x2 020200 Equation =X/32768*14.64,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x809 000100 Cat0ID =0x1 020005 Title ="Desired A/F Ratio Min" 020011 DescSize =0x59 020010 Desc ="LAMMIN - The desired A/F ratio is clipped to this limit during closed loop fuel control." 020020 Units ="A/F ratio" 020050 SizeInBits =0x10 020100 Address =0x9AA4 020150 Flags =0x2 020200 Equation =X/32768*14.64,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x5A85 000100 Cat0ID =0xC 020005 Title ="Desired EGR Valve Position Time Constant" 020011 DescSize =0xEF 020010 Desc ="TCDLOP - The time constant for the rolling average calculation of the 'Desired EGR Valve Position' (aka DELOPT) value.\r\n\r\nLarger time constant values increase the time lag of the value being updated but reduce unwanted transients from it." 020020 Units ="secs" 020050 SizeInBits =0x10 020100 Address =0x97E8 020150 Flags =0x2 020200 Equation =X/1024,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x42DA 000100 Cat0ID =0x9 020005 Title ="Desired Idle RPM Self Test Time Constant" 020011 DescSize =0x18B 020010 Desc ="VTCDSN - The time constant for the rolling average calculation of the 'Desired Idle RPM' (aka DSDRPM) value during self test.\r\n\r\nLarger time constant values increase the time lag of the value being updated but reduce unwanted transients from it.\r\n\r\nSetting to zero will result in the 'Desired Idle RPM Time Constant' (aka TCDESN) parameter being used in lieu of this parameter during self test." 020020 Units ="secs" 020050 SizeInBits =0x10 020100 Address =0x8EEA 020150 Flags =0x2 020200 Equation =X/1024,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0xBA2 000100 Cat0ID =0x6 020005 Title ="Desired Idle RPM Time Constant" 020011 DescSize =0xE5 020010 Desc ="TCDESN - The time constant for the rolling average calculation of the 'Desired Idle RPM' (aka DSDRPM) value.\r\n\r\nLarger time constant values increase the time lag of the value being updated but reduce unwanted transients from it." 020020 Units ="secs" 020050 SizeInBits =0x10 020100 Address =0x97E6 020150 Flags =0x2 020200 Equation =X/1024,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x6D8E 000100 Cat0ID =0x1 020005 Title ="Desired Rich Correction" 020011 DescSize =0x81 020010 Desc ="LMBJMP - When exiting the Filtered Idle Airmass Region this value is subtracted from the desired AF ratio to richen the mixture." 020020 Units ="A/F ratio" 020050 SizeInBits =0x10 020100 Address =0x9AF2 020150 Flags =0x2 020200 Equation =X/32768*14.64,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x7C3D 000100 Cat0ID =0x7 020005 Title ="Disable ISC" 020011 DescSize =0xE3 020010 Desc ="Z_ISCSW - Normally this is set to \"3A\", change to \"00\" to set the ISC valve dutycycle to 0% when determining the 'Throttle Body Air Flow' (aka ITHBMA) parameter value.\r\n\r\nWARNING: Do not use any values other than one of these." 020020 Units ="" 020100 Address =0x5E4D 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x3 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x197F 000100 Cat0ID =0x2 020005 Title ="Dwell Switch Point" 020011 DescSize =0x41 020010 Desc ="DWLTSW - Switch point for the change of maximum permitted dwell." 020020 Units ="secs" 020050 SizeInBits =0x10 020100 Address =0x945C 020150 Flags =0x2 020200 Equation =X/65536,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x7D4E 000100 Cat0ID =0x7 020005 Title ="Dwell Time Table Select Temperature" 020011 DescSize =0xD4 020010 Desc ="DWLTBP - The estimated coil temperature value used to determine which coil dwell time table is to be used. The tables are:\r\n\r\n'Dwell Time High Temperature' (aka FN160B)\r\n'Dwell Time Low Temperature' (aka FN160A)" 020020 Units ="deg F" 020100 Address =0x945B 020150 Flags =0x1 020200 Equation =X*2,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x30FD 000100 Cat0ID =0x2 020005 Title ="Dwell Turn On Time Low RPM Clip" 020011 DescSize =0x7 020010 Desc ="MINDLA" 020020 Units ="% of PIP period" 020050 SizeInBits =0x10 020100 Address =0x9456 020150 Flags =0x2 020200 Equation =X/655.36,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x7F70 000100 Cat0ID =0x2 020005 Title ="Dwell Turn On Time High RPM Clip" 020011 DescSize =0x7 020010 Desc ="MINDLB" 020020 Units ="% of PIP period" 020050 SizeInBits =0x10 020100 Address =0x9458 020150 Flags =0x2 020200 Equation =X/655.36,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x1379 000100 Cat0ID =0x9 020005 Title ="ECT KOEO Max" 020011 DescSize =0x7 020010 Desc ="VIECT2" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8F52 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5622 000100 Cat0ID =0x9 020005 Title ="ECT KOEO Min" 020011 DescSize =0x7 020010 Desc ="VIECT1" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8F50 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x3FEB 000100 Cat0ID =0x9 020005 Title ="ECT KOER Max" 020011 DescSize =0x7 020010 Desc ="VIECT4" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8F56 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x20B8 000100 Cat0ID =0x9 020005 Title ="ECT KOER Min" 020011 DescSize =0x7 020010 Desc ="VIECT3" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8F54 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5DC4 000100 Cat0ID =0x4 020005 Title ="ECT Max" 020011 DescSize =0x54 020010 Desc ="ECTMAX - Value at which the eec considers that the sensor has failed open circuit." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8EDA 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x356A 000100 Cat0ID =0xA 020005 Title ="ECT Max at Start for Warm Up Flag" 020011 DescSize =0xC9 020010 Desc ="VECT5 - The maximum coolant temperature at start up permitted for the KAM Warm Up counter to be updated. The temperature then needs to increase beyond the 'ECT Min for Warm Up Flag' (aka VECT3) value." 020020 Units ="deg F" 020100 Address =0x8EC6 020150 Flags =0x1 020200 Equation =X*2,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x32F9 000100 Cat0ID =0x4 020005 Title ="ECT Min" 020011 DescSize =0x54 020010 Desc ="ECTMIN - Value at which the eec considers that the sensor has failed short circuit." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8ED8 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x6FE2 000100 Cat0ID =0xA 020005 Title ="ECT Min for Warm Up Flag" 020011 DescSize =0xCB 020010 Desc ="VECT3 - The minimum coolant temperature required for the KAM Warm Up counter to be updated. The temperature at start also needs to be less than the 'ECT Max at Start for Warm Up Flag' (aka VECT5) value." 020020 Units ="deg F" 020100 Address =0x8F58 020150 Flags =0x1 020200 Equation =X*2,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x5E9B 000100 Cat0ID =0x3 020005 Title ="ECT Time Constant" 020011 DescSize =0xD4 020010 Desc ="TCECT - The time constant for the rolling average calculation of the 'ECT' (aka ECT) value.\r\n\r\nLarger time constant values increase the time lag of the value being updated but reduce unwanted transients from it." 020020 Units ="secs" 020050 SizeInBits =0x10 020100 Address =0x97EC 020150 Flags =0x2 020200 Equation =X/1024,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x8EC 000100 Cat0ID =0xC 020005 Title ="EGR Actual Percent Time Constant" 020011 DescSize =0xE7 020010 Desc ="TCEACT - The time constant for the rolling average calculation of the 'EGR Actual Percent' (aka EGRACT) value.\r\n\r\nLarger time constant values increase the time lag of the value being updated but reduce unwanted transients from it." 020020 Units ="secs" 020050 SizeInBits =0x10 020100 Address =0x97EE 020150 Flags =0x2 020200 Equation =X/1024,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x7DE1 000100 Cat0ID =0xC 020005 Title ="EGR Cold Start Delay #1" 020011 DescSize =0xA 020010 Desc ="EGRTD1 - " 020020 Units ="secs" 020100 Address =0x97CA 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x1093 000100 Cat0ID =0x9 020005 Title ="EGR Continuous Flow Test Max Load " 020011 DescSize =0x9 020010 Desc ="VEGRLOAD" 020020 Units ="load" 020050 SizeInBits =0x10 020100 Address =0x8F08 020150 Flags =0x2 020200 Equation =X/327.68,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x1959 000100 Cat0ID =0xC 020005 Title ="EGR Cold Start Delay #2" 020011 DescSize =0xA 020010 Desc ="EGRTD4 - " 020020 Units ="secs" 020100 Address =0x97CB 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x2ED6 000100 Cat0ID =0x9 020005 Title ="EGR Cruise Test Dutycycle" 020011 DescSize =0x7 020010 Desc ="VCRTDC" 020020 Units ="%" 020100 Address =0x8F03 020200 Equation =X/1.28,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x76FF 000100 Cat0ID =0x9 020005 Title ="EGR Cruise Test Time" 020011 DescSize =0x7 020010 Desc ="VECTMR" 020020 Units ="secs" 020100 Address =0x8F02 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x1E7F 000100 Cat0ID =0xC 020005 Title ="EGR Deadband Value for EVP" 020011 DescSize =0x7 020010 Desc ="EGRDED" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x97D0 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x6EE1 000100 Cat0ID =0xC 020005 Title ="EGR Desired Downstream Pressure Time Constant" 020011 DescSize =0xF1 020010 Desc ="TCDP - The time constant for the rolling average calculation of the 'EGR Desired Downstream Pressure' (aka DESDP) value.\r\n\r\nLarger time constant values increase the time lag of the value being updated but reduce unwanted transients from it." 020020 Units ="secs" 020050 SizeInBits =0x10 020100 Address =0x97EA 020150 Flags =0x2 020200 Equation =X/1024,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x4370 000100 Cat0ID =0xC 020005 Title ="EGR Dutycycle for Valve to Open" 020011 DescSize =0x6 020010 Desc ="DCOFF" 020020 Units ="%" 020050 SizeInBits =0x10 020100 Address =0x97CE 020150 Flags =0x2 020200 Equation =X/327.68,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x4610 000100 Cat0ID =0xC 020005 Title ="EGR Hot Start Delay" 020011 DescSize =0xA 020010 Desc ="EGRTD3 - " 020020 Units ="secs" 020100 Address =0x97C7 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x7F4D 000100 Cat0ID =0xC 020005 Title ="EGR Mass Flow Minimum" 020011 DescSize =0x93 020010 Desc ="MINDES - The minimum desired EGR mass flow allowed in order to avoid EGR operation in the low flow non linear region of the EGR transfer function." 020020 Units ="lb/min" 020050 SizeInBits =0x10 020100 Address =0x97DE 020150 Flags =0x2 020200 Equation =X/1024,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x4FBC 000100 Cat0ID =0xC 020005 Title ="EGR Mass Flow Minimum Hysteresis" 020011 DescSize =0x4C 020010 Desc ="DESHYS - Hysteresis for the 'EGR Mass Flow Minimum' (aka MINDES) parameter." 020020 Units ="lb/min" 020050 SizeInBits =0x10 020100 Address =0x97E0 020150 Flags =0x2 020200 Equation =X/1024,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x4C3C 000100 Cat0ID =0xC 020005 Title ="EGR Multiplier" 020011 DescSize =0x5 020010 Desc ="X - " 020020 Units ="multiplier" 020100 Address =0x97CD 020200 Equation =X/128,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5DD1 000100 Cat0ID =0xC 020005 Title ="EGR PT Adder" 020011 DescSize =0x5 020010 Desc ="KPEI" 020020 Units ="%" 020100 Address =0x97CC 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x5E02 000100 Cat0ID =0xC 020005 Title ="EGR Ramp In Delay" 020011 DescSize =0x7 020010 Desc ="EGRMPT" 020020 Units ="secs" 020100 Address =0x97D2 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x40F8 000100 Cat0ID =0x9 020005 Title ="EGR Test Dutycycle Maximum" 020011 DescSize =0x7 020010 Desc ="VDCMAX" 020020 Units ="%" 020100 Address =0x8F06 020200 Equation =X/1.28,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x55BA 000100 Cat0ID =0x9 020005 Title ="EGR Test Dutycycle Rate" 020011 DescSize =0x7 020010 Desc ="VEGRAT" 020020 Units ="% per sec" 020100 Address =0x8F04 020200 Equation =X/1.28,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x5CCB 000100 Cat0ID =0x9 020005 Title ="EGR Test Dutycycle Minimum" 020011 DescSize =0x7 020010 Desc ="VDCMIN" 020020 Units ="%" 020100 Address =0x8F05 020200 Equation =X/1.28,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x4127 000100 Cat0ID =0xC 020005 Title ="EGR Time Constant" 020011 DescSize =0xD7 020010 Desc ="TCEGR - The time constant for the rolling average calculation of the 'EGR' (aka EGRBAR) value.\r\n\r\nLarger time constant values increase the time lag of the value being updated but reduce unwanted transients from it." 020020 Units ="secs" 020050 SizeInBits =0x10 020100 Address =0x9808 020150 Flags =0x2 020200 Equation =X/1024,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x1B40 000100 Cat0ID =0x9 020005 Title ="EGR Test Time Wait" 020011 DescSize =0x7 020010 Desc ="VEITMR" 020020 Units ="secs" 020100 Address =0x8F16 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5E06 000100 Cat0ID =0xC 020005 Title ="EGR Type" 020011 DescSize =0x27 020010 Desc ="PFEHP - 0 = sonic, 1 = PFE, 2 = no egr" 020020 Units ="" 020100 Address =0x97D9 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x77BC 000100 Cat0ID =0xC 020005 Title ="EGR Warm Start Delay #1" 020011 DescSize =0xA 020010 Desc ="EGRTD2 - " 020020 Units ="secs" 020100 Address =0x97C8 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x29A 000100 Cat0ID =0xC 020005 Title ="EGR Warm Start Delay #2" 020011 DescSize =0xA 020010 Desc ="EGRTD5 - " 020020 Units ="secs" 020100 Address =0x97C9 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x5DA2 000100 Cat0ID =0x7 020005 Title ="Engine Displacement" 020011 DescSize =0xA1 020010 Desc ="SARCHG - If altered the following parameters will need adjustment too;\r\n\r\n'Manifold Fast Fill Constant' (aka FKARC1)\r\n'Manifold Slow Fill Constant' (aka FKARCH)" 020020 Units ="Cubic In." 020050 SizeInBits =0x10 020100 Address =0x901A 020150 Flags =0x2 020200 Equation =X*0.0430981,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x568F 000100 Cat0ID =0x5 020005 Title ="Engine Warm ECT" 020011 DescSize =0x4F 020010 Desc ="TEMPFB - The minimum temperature at which the engine is considered to be warm." 020020 Units ="deg F" 020100 Address =0x9E60 020150 Flags =0x1 020200 Equation =X*2,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x2505 000100 Cat0ID =0xC 020005 Title ="EPT at Idle Back Pressure" 020011 DescSize =0x62 020010 Desc ="IDLDEL - Checked during the key on 'EPT at Idle' (aka EPTZER) update routine.\r\n\r\nTo be confirmed." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x947E 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5E37 000100 Cat0ID =0xC 020005 Title ="EPT at Idle Min ECT" 020011 DescSize =0x53 020010 Desc ="CTEHI - The minimum ECT for the 'EPT at Idle' (aka EPTZER) value to be calculated." 020020 Units ="deg F" 020100 Address =0x97DC 020150 Flags =0x1 020200 Equation =X*2,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x34BC 000100 Cat0ID =0xC 020005 Title ="EPT at Idle RPM Hysteresis" 020011 DescSize =0x94 020010 Desc ="IERPMH - Hysteresis value added to 'Desired Idle RPM' value. If the rpm exceeds this resultant value then the 'EPT at Idle' calculation is skipped." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x97DA 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x4EC4 000100 Cat0ID =0x9 020005 Title ="EPT Continuous Test Max" 020011 DescSize =0x7 020010 Desc ="VEPTIH" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8F9C 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x198C 000100 Cat0ID =0x9 020005 Title ="EPT Continuous Test Min" 020011 DescSize =0x7 020010 Desc ="VEPTIL" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8F9A 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x773F 000100 Cat0ID =0x9 020005 Title ="EPT Cruise Test Min" 020011 DescSize =0x7 020010 Desc ="VEPTCL" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8FA0 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x4514 000100 Cat0ID =0x9 020005 Title ="EPT KOEO Max" 020011 DescSize =0x7 020010 Desc ="VEPTHL" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8F94 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x1B88 000100 Cat0ID =0x9 020005 Title ="EPT KOEO Min" 020011 DescSize =0x7 020010 Desc ="VEPTLL" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8F92 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x592F 000100 Cat0ID =0x9 020005 Title ="EPT KOER Max" 020011 DescSize =0x7 020010 Desc ="VEPTRH" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8F98 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5B53 000100 Cat0ID =0x9 020005 Title ="EPT KOER Min" 020011 DescSize =0x7 020010 Desc ="VEPTRL" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8F96 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x6A24 000100 Cat0ID =0x9 020005 Title ="EPT KOER Min Change" 020011 DescSize =0x7 020010 Desc ="VEPTDL" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8F9E 020150 Flags =0x3 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x7952 000100 Cat0ID =0x4 020005 Title ="EPT Max" 020011 DescSize =0x69 020010 Desc ="EPTMAX - Value at which the eec considers that the exhaust pressure transducer has failed open circuit." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8F90 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x4FA4 000100 Cat0ID =0x4 020005 Title ="EPT Min" 020011 DescSize =0x69 020010 Desc ="EPTMIN - Value at which the eec considers that the exhaust pressure transducer has failed short circuit." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8F8E 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x59C8 000100 Cat0ID =0x9 020005 Title ="EPT Test Time Constant" 020011 DescSize =0xE9 020010 Desc ="VTCEPT - The time constant for the rolling average calculation of the 'EPT' (aka EPTBAR) value during self test.\r\n\r\nLarger time constant values increase the time lag of the value being updated but reduce unwanted transients from it." 020020 Units ="secs" 020050 SizeInBits =0x10 020100 Address =0x8FA4 020150 Flags =0x2 020200 Equation =X/1024,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0xF53 000100 Cat0ID =0xC 020005 Title ="EPT Time Constant" 020011 DescSize =0xF7 020010 Desc ="TCEPT - The time constant for the rolling average calculation of the 'EPT' (aka EPTBAR) and 'EPT at Idle' (aka EPTZER) values.\r\n\r\nLarger time constant values increase the time lag of the value being updated but reduce unwanted transients from it." 020020 Units ="secs" 020050 SizeInBits =0x10 020100 Address =0x97F0 020150 Flags =0x2 020200 Equation =X/1024,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5E03 000100 Cat0ID =0xC 020005 Title ="EPT Transfer" 020011 DescSize =0x7 020010 Desc ="XFREPT" 020020 Units ="in H2O/counts" 020050 SizeInBits =0x10 020100 Address =0x97D4 020150 Flags =0x3 020200 Equation =X/131072,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0xBA1 000100 Cat0ID =0xC 020005 Title ="EPT Transfer Reciprocol" 020011 DescSize =0x7 020010 Desc ="IXFRPR" 020020 Units ="counts/in H2O" 020050 SizeInBits =0x10 020100 Address =0x97D6 020150 Flags =0x3 020200 Equation =X/131072,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5574 000100 Cat0ID =0x12 020005 Title ="Equilibrium Fuel Transfer Constant Multiplier" 020011 DescSize =0x6B 020010 Desc ="MTEFTC - A multiplier of the result of the 'Equilibrium Fuel Transfer Constant' (aka FN1322) table lookup." 020020 Units ="multiplier" 020100 Address =0x9012 020200 Equation =X/32,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5573 000100 Cat0ID =0x12 020005 Title ="Equilibrium Intake Surface Fuel Multiplier" 020011 DescSize =0x68 020010 Desc ="MTEISF - A multiplier of the result of the 'Equilibrium Intake Surface Fuel' (aka FN1321) table lookup." 020020 Units ="multiplier" 020100 Address =0x9011 020200 Equation =X/32,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x2526 000100 Cat0ID =0x9 020005 Title ="Error 14 Threshold (PIP fault)" 020011 DescSize =0x1C 020010 Desc ="C14LVL - PIP signal erratic" 020020 Units ="" 020100 Address =0x8F1B 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x4AF8 000100 Cat0ID =0x9 020005 Title ="Error 14 Up Count (PIP fault)" 020011 DescSize =0x1B 020010 Desc ="C14UP - PIP signal erratic" 020020 Units ="" 020100 Address =0x8F31 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x214C 000100 Cat0ID =0x9 020005 Title ="Error 22 Threshold (BP fault)" 020011 DescSize =0x20 020010 Desc ="C22LVL - BP sensor out of range" 020020 Units ="" 020100 Address =0x8F1C 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x26A 000100 Cat0ID =0x9 020005 Title ="Error 22 Up Count (BP fault)" 020011 DescSize =0x21 020010 Desc ="C22UP - BAP sensor out of range." 020020 Units ="" 020100 Address =0x8F32 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x7DD6 000100 Cat0ID =0x9 020005 Title ="Error 29 Threshold (VSS fault)" 020011 DescSize =0x13 020010 Desc ="C29LVL - VSS fault" 020020 Units ="" 020100 Address =0x8F1D 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x7DE8 000100 Cat0ID =0x9 020005 Title ="Error 29 Up Count (VSS fault)" 020011 DescSize =0x13 020010 Desc ="\"C22UP - VSS fault" 020020 Units ="" 020100 Address =0x8F33 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x51CE 000100 Cat0ID =0x9 020005 Title ="Error 31 Threshold (EVP fault)" 020011 DescSize =0x39 020010 Desc ="C31LVL - Evaporative canister purge solenoid range error" 020020 Units ="" 020100 Address =0x8F1E 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x6654 000100 Cat0ID =0x9 020005 Title ="Error 31 Up Count (EVP fault)" 020011 DescSize =0x38 020010 Desc ="C31UP - Evaporative canister purge solenoid range error" 020020 Units ="" 020100 Address =0x8F34 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x20BB 000100 Cat0ID =0x9 020005 Title ="Error 32 Threshold (EVP limit)" 020011 DescSize =0x48 020010 Desc ="C32LVL - Evaporative canister purge solenoid not responding during test" 020020 Units ="" 020100 Address =0x8F1F 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x4CC0 000100 Cat0ID =0x9 020005 Title ="Error 32 Up Count (EVP limit)" 020011 DescSize =0x47 020010 Desc ="C32UP - Evaporative canister purge solenoid not responding during test" 020020 Units ="" 020100 Address =0x8F35 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x740C 000100 Cat0ID =0x9 020005 Title ="Error 33 Threshold (EGR flow)" 020011 DescSize =0x1A 020010 Desc ="C33LVL - EGR did not flow" 020020 Units ="" 020100 Address =0x8F20 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x40E8 000100 Cat0ID =0x9 020005 Title ="Error 33 Up Count (EGR flow)" 020011 DescSize =0x1A 020010 Desc ="C33UP - EGR did not flow." 020020 Units ="" 020100 Address =0x8F36 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x6467 000100 Cat0ID =0x9 020005 Title ="Error 34 Threshold (EGR limit)" 020011 DescSize =0x19 020010 Desc ="C34LVL - EGR range error" 020020 Units ="" 020100 Address =0x8F21 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x1FF7 000100 Cat0ID =0x9 020005 Title ="Error 34 Up Count (EGR limit)" 020011 DescSize =0x19 020010 Desc ="C34UP - EGR range error." 020020 Units ="" 020100 Address =0x8F37 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x55AE 000100 Cat0ID =0x9 020005 Title ="Error 35 Threshold (EVP high)" 020011 DescSize =0x18 020010 Desc ="C35LVL - EVP input high" 020020 Units ="" 020100 Address =0x8F22 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x71DC 000100 Cat0ID =0x9 020005 Title ="Error 35 Up Count (EVP high)" 020011 DescSize =0x17 020010 Desc ="C35UP - EVP input high" 020020 Units ="" 020100 Address =0x8F38 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x85F 000100 Cat0ID =0x9 020005 Title ="Error 41 Threshold (right HEGO switching)" 020011 DescSize =0x27 020010 Desc ="C41LVL - Lack of right HEGO switching." 020020 Units ="" 020100 Address =0x8F23 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x5CB5 000100 Cat0ID =0x9 020005 Title ="Error 41 Up Count (right HEGO switching)" 020011 DescSize =0x26 020010 Desc ="C41UP - Lack of right HEGO switching." 020020 Units ="" 020100 Address =0x8F39 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x6ED6 000100 Cat0ID =0x9 020005 Title ="Error 51 Threshold (ECT open circuit)" 020011 DescSize =0x1A 020010 Desc ="C51LVL - ECT open circuit" 020020 Units ="" 020100 Address =0x8F24 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x290D 000100 Cat0ID =0x9 020005 Title ="Error 51 Up Count (ECT open circuit)" 020011 DescSize =0x19 020010 Desc ="C51UP - ECT open circuit" 020020 Units ="" 020100 Address =0x8F3A 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x1EBF 000100 Cat0ID =0x9 020005 Title ="Error 53 Threshold (TPS open circuit)" 020011 DescSize =0x1A 020010 Desc ="C53LVL - TPS open circuit" 020020 Units ="" 020100 Address =0x8F25 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x2800 000100 Cat0ID =0x9 020005 Title ="Error 53 Up Count (TPS open circuit)" 020011 DescSize =0x19 020010 Desc ="C53UP - TPS open circuit" 020020 Units ="" 020100 Address =0x8F3B 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0xA08 000100 Cat0ID =0x9 020005 Title ="Error 54 Threshold (ACT open circuit)" 020011 DescSize =0x1A 020010 Desc ="C54LVL - ACT open circuit" 020020 Units ="" 020100 Address =0x8F26 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x7FF4 000100 Cat0ID =0x9 020005 Title ="Error 54 Up Count (ACT open circuit)" 020011 DescSize =0x19 020010 Desc ="C54UP - ACT open circuit" 020020 Units ="" 020100 Address =0x8F3C 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x4EA0 000100 Cat0ID =0x9 020005 Title ="Error 56 Threshold (MAF open circuit)" 020011 DescSize =0x1A 020010 Desc ="C56LVL - MAF open circuit" 020020 Units ="" 020100 Address =0x8F27 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x63F7 000100 Cat0ID =0x9 020005 Title ="Error 56 Up Count (MAF open circuit)" 020011 DescSize =0x19 020010 Desc ="C56UP - MAF open circuit" 020020 Units ="" 020100 Address =0x8F3D 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x2324 000100 Cat0ID =0x9 020005 Title ="Error 61 Threshold (ECT short circuit)" 020011 DescSize =0x1B 020010 Desc ="C61LVL - ECT short circuit" 020020 Units ="" 020100 Address =0x8F28 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x2894 000100 Cat0ID =0x9 020005 Title ="Error 61 Up Count (ECT short circuit)" 020011 DescSize =0x1A 020010 Desc ="C61UP - ECT short circuit" 020020 Units ="" 020100 Address =0x8F3E 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x580F 000100 Cat0ID =0x9 020005 Title ="Error 63 Threshold (TPS short circuit)" 020011 DescSize =0x1B 020010 Desc ="C63LVL - TPS short circuit" 020020 Units ="" 020100 Address =0x8F29 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x6603 000100 Cat0ID =0x9 020005 Title ="Error 63 Up Count (TPS short circuit)" 020011 DescSize =0x1A 020010 Desc ="C63UP - TPS short circuit" 020020 Units ="" 020100 Address =0x8F3F 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x1BD3 000100 Cat0ID =0x9 020005 Title ="Error 64 Threshold (ACT short circuit)" 020011 DescSize =0x1B 020010 Desc ="C64LVL - ACT short circuit" 020020 Units ="" 020100 Address =0x8F2A 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0xEB1 000100 Cat0ID =0x9 020005 Title ="Error 64 Up Count (ACT short circuit)" 020011 DescSize =0x1A 020010 Desc ="C64UP - ACT short circuit" 020020 Units ="" 020100 Address =0x8F40 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x53AE 000100 Cat0ID =0x9 020005 Title ="Error 66 Threshold (MAF short circuit)" 020011 DescSize =0x1B 020010 Desc ="C66LVL - MAF short circuit" 020020 Units ="" 020100 Address =0x8F2B 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x679D 000100 Cat0ID =0x9 020005 Title ="Error 66 Up Count (MAF short circuit)" 020011 DescSize =0x1A 020010 Desc ="C66UP - MAF short circuit" 020020 Units ="" 020100 Address =0x8F41 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x120C 000100 Cat0ID =0x9 020005 Title ="Error 87 Threshold (fuel pump fault)" 020011 DescSize =0x21 020010 Desc ="C87LVL - Fuel pump circuit fault" 020020 Units ="" 020100 Address =0x8F2C 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0xA9D 000100 Cat0ID =0x9 020005 Title ="Error 87 Up Count (fuel pump fault)" 020011 DescSize =0x20 020010 Desc ="C87UP - Fuel pump circuit fault" 020020 Units ="" 020100 Address =0x8F42 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x59E5 000100 Cat0ID =0x9 020005 Title ="Error 91 Threshold (left HEGO switching)" 020011 DescSize =0x26 020010 Desc ="C91LVL - Lack of left HEGO switching." 020020 Units ="" 020100 Address =0x8F2D 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x4428 000100 Cat0ID =0x9 020005 Title ="Error 91 Up Count (left HEGO switching)" 020011 DescSize =0x25 020010 Desc ="C91UP - Lack of left HEGO switching." 020020 Units ="" 020100 Address =0x8F43 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x4D50 000100 Cat0ID =0x9 020005 Title ="Error 95 Threshold (fuel pump open circuit)" 020011 DescSize =0x3A 020010 Desc ="C95LVL - Fuel pump open circuit, bad ground or always on." 020020 Units ="" 020100 Address =0x8F2E 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x7439 000100 Cat0ID =0x9 020005 Title ="Error 95 Up Count (fuel pump open circuit)" 020011 DescSize =0x39 020010 Desc ="C95UP - Fuel pump open circuit, bad ground or always on." 020020 Units ="" 020100 Address =0x8F44 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x6865 000100 Cat0ID =0x9 020005 Title ="Error 96 Threshold (fuel pump monitor)" 020011 DescSize =0x33 020010 Desc ="C96LVL - Fuel pump monitor circuit shows no power." 020020 Units ="" 020100 Address =0x8F2F 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x3292 000100 Cat0ID =0x9 020005 Title ="Error 96 Up Count (fuel pump monitor)" 020011 DescSize =0x32 020010 Desc ="C96UP - Fuel pump monitor circuit shows no power." 020020 Units ="" 020100 Address =0x8F45 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x336C 000100 Cat0ID =0x9 020005 Title ="EVP Cruise Test Limit" 020011 DescSize =0x7 020010 Desc ="VEVPCL" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8F14 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x2C9 000100 Cat0ID =0x9 020005 Title ="EVP Test Lower Limit" 020011 DescSize =0x7 020010 Desc ="VEVPLL" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8F0E 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5F54 000100 Cat0ID =0x9 020005 Title ="EVP Test Minimum Change" 020011 DescSize =0x7 020010 Desc ="VEVPDL" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8F12 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x697A 000100 Cat0ID =0x9 020005 Title ="EVP Test Upper Limit" 020011 DescSize =0x7 020010 Desc ="VEVPHL" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8F10 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x3841 000100 Cat0ID =0x9 020005 Title ="EVR Open Circuit Check" 020011 DescSize =0xA 020010 Desc ="OCCDT4 - " 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8F82 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x2B14 000100 Cat0ID =0x4 020005 Title ="EVP Max" 020011 DescSize =0x68 020010 Desc ="EVPMAX - Value at which the eec considers that the evaporative canister purge has failed open circuit." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8F0C 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x62DE 000100 Cat0ID =0x9 020005 Title ="EPT Test Max Idle RPM" 020011 DescSize =0x3 020010 Desc ="VN" 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x8FA2 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x6D1F 000100 Cat0ID =0x4 020005 Title ="EVP Min" 020011 DescSize =0x71 020010 Desc ="EVPMIN - Value at which the eec considers that the evaporative canister purge solenoid has failed short circuit." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8F0A 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x6A18 000100 Cat0ID =0x9 020005 Title ="Failure Mode Hysteresis" 020011 DescSize =0x50 020010 Desc ="FILHYS - Hysteresis value for the 'Error ** Threshold' (aka C**LVL) parameters." 020020 Units ="" 020100 Address =0x8F59 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x69F6 000100 Cat0ID =0x6 020005 Title ="FAM Deadband" 020011 DescSize =0x7 020010 Desc ="FAMLIM" 020020 Units ="%" 020050 SizeInBits =0x10 020100 Address =0x9054 020150 Flags =0x2 020200 Equation =X/655.36,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x5E9C 000100 Cat0ID =0x6 020005 Title ="FAM Entry Airmass Maximum" 020011 DescSize =0x69 020010 Desc ="TCFAM - The maximum airmass in order for the FAM_FLG to be set.\r\n\r\nPID to be confirmed (probably wrong)" 020020 Units ="lb/min" 020050 SizeInBits =0x10 020100 Address =0x97F2 020150 Flags =0x2 020200 Equation =X/1024,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x133F 000100 Cat0ID =0x6 020005 Title ="FAM Entry Max Multiplier" 020011 DescSize =0xA6 020010 Desc ="EFAMPH - On entry to the filtered air mass region the filtered air mass value is multiplied by this parameter to establish an upper clip limit on the air mass value." 020020 Units ="multiplier" 020100 Address =0x9E7B 020200 Equation =X/128,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x63C9 000100 Cat0ID =0x6 020005 Title ="FAM Entry Min Multiplier" 020011 DescSize =0xA6 020010 Desc ="EFAMPL - On entry to the filtered air mass region the filtered air mass value is multiplied by this parameter to establish an lower clip limit on the air mass value." 020020 Units ="multiplier" 020100 Address =0x9E7C 020200 Equation =X/128,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5673 000100 Cat0ID =0x6 020005 Title ="FAM Filter Sample Rate" 020011 DescSize =0x6B 020010 Desc ="SAMRAT - Used to pace the filter rate for the filtered airmass in terms of program background loop counts." 020020 Units ="background counts" 020100 Address =0x9042 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x6399 000100 Cat0ID =0x6 020005 Title ="FAM Incremental Adder" 020011 DescSize =0x61 020010 Desc ="AMRPM - Added to desird idle rpm to give a maximum rpm below which air mass filtering can occur." 020020 Units ="rpm" 020100 Address =0x9E79 020200 Equation =X*16,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x5238 000100 Cat0ID =0x6 020005 Title ="FAM Incremental Adder Hysteresis" 020011 DescSize =0x40 020010 Desc ="AMRPMH - Hysteresis for the 'FAM Incremental Adder' parameter." 020020 Units ="rpm" 020100 Address =0x9E7A 020200 Equation =X*16,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x55DB 000100 Cat0ID =0x6 020005 Title ="FAM Increment/Decrement" 020011 DescSize =0x7 020010 Desc ="FAMINC" 020020 Units ="lb/min" 020050 SizeInBits =0x10 020100 Address =0x9020 020150 Flags =0x2 020200 Equation =X/2048,TH|0|0|0|0| 020210 DecimalPl =0x6 %%END%% %%CONSTANT%% 000002 UniqueID =0x56DC 000100 Cat0ID =0x6 020005 Title ="FAM Maximum Clip Multiplier" 020011 DescSize =0x8A 020010 Desc ="MAXFAM - The instantaneous air mass value is multiplied by this parameter to establish an upper clip limit on the filtered airmass value." 020020 Units ="multiplier" 020050 SizeInBits =0x10 020100 Address =0x9056 020150 Flags =0x2 020200 Equation =X/32768,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x6398 000100 Cat0ID =0x6 020005 Title ="FAM Max RPM" 020011 DescSize =0x52 020010 Desc ="AMDESN - The maximum desired idle rpm at which air mass filtering can be enabled." 020020 Units ="rpm" 020100 Address =0x9E78 020200 Equation =X*16,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x6366 000100 Cat0ID =0x6 020005 Title ="FAM Multiplier" 020011 DescSize =0xD4 020010 Desc ="DELTAM - A multiplier of the filtered airmass value that establishes a value that when exceeded by the instantaneous airmass causes the eec to use the instantaneous airmass in lieu of the filtered airmass value." 020020 Units ="multiplier" 020050 SizeInBits =0x10 020100 Address =0x9E76 020150 Flags =0x2 020200 Equation =X/128,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5672 000100 Cat0ID =0x6 020005 Title ="FAM TP" 020011 DescSize =0x12A 020010 Desc ="DELRAT - When the relative throttle position is less than or equal to this parameter then FAM entry is allowed providing the other conditions for FAM entry are satisfied. Set equal to the sum of the following parameters;\r\n\r\n'TPS PT Threshold' (aka DELTA)\r\n'TPS PT Threshold Hysteresis' (aka HYSTS)" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x9040 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x721F 000100 Cat0ID =0x6 020005 Title ="FAM TP Hysteresis" 020011 DescSize =0x7 020010 Desc ="DLHYST" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x9E7E 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x49C8 000100 Cat0ID =0x5 020005 Title ="Force Continuous O/L" 020011 DescSize =0xEC 020010 Desc ="Z_OLSW - Normally this is set to \"D7\", change to \"20\" to prevent the ecu going into closed loop mode.\r\n\r\nWARNING: Do not enter any value other than one of these.\r\n\r\nThis needs verifying that CL is forced under all operating conditions." 020020 Units ="n/a" 020100 Address =0x4274 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x3 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x6244 000100 Cat0ID =0x7 020005 Title ="Fixed Injector Timing Cold Start Delay #1" 020011 DescSize =0x129 020010 Desc ="NITMR1 - When the ECT at start is less than the 'Cold Start Max ECT' value this is the minimum time that must pass since exiting crank in order for it to be possible to use fixed injector timing when in neutral.\r\n\r\nNote: the 'Fixed Injector Timing Cold Start Delay #2' value also needs exceeding." 020020 Units ="secs" 020100 Address =0x9AC0 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x5B7C 000100 Cat0ID =0x7 020005 Title ="Fixed Injector Timing Cold Start Delay #2" 020011 DescSize =0x147 020010 Desc ="NITMR4 - When the ECTat start is less than the 'Cold Start Max ECT' value this is the minimum time that must pass since the ECT exceeded the 'Engine Warm ECT' value in order for it to be possible to use fixed injector timing when in neutral.\r\n\r\nNote: the 'Fixed Injector Timing Cold Start Delay #1' value also needs exceeding." 020020 Units ="secs" 020100 Address =0x9AC1 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x4A8B 000100 Cat0ID =0x7 020005 Title ="Fixed Injector Timing Hot Start Delay" 020011 DescSize =0xD6 020010 Desc ="NITMR3 - When the ECT at start is greater than the 'Hot Start Min ECT' value this is the minimum time that must pass since exiting crank in order for it to be possible to use fixed injector timing when in neutral." 020020 Units ="secs" 020100 Address =0x9ABD 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0xE01 000100 Cat0ID =0x7 020005 Title ="Fixed Injector Timing Warm Start Delay #1" 020011 DescSize =0x140 020010 Desc ="NITMR2 - When the ECT at start is between the 'Cold Start Max ECT' and 'Hot Start Min ECT' values this is the minimum time that must pass since exiting crank in order for it to be possible to use fixed injector timing when in neutral.\r\n\r\nNote: the 'Fixed Injector Timing Warm Start Delay #2' value also needs exceeding." 020020 Units ="secs" 020100 Address =0x9ABE 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x706D 000100 Cat0ID =0x7 020005 Title ="Fixed Injector Timing Warm Start Delay #2" 020011 DescSize =0x15F 020010 Desc ="NITMR5 - When the ECT at start is between the 'Cold Start Max ECT' and 'Hot Start Min ECT' values this is the minimum time that must pass since the ECT exceeded the 'Engine Warm ECT' value in order for it to be possible to use fixed injector timing when in neutral.\r\n\r\nNote: the 'Fixed Injector Timing Warm Start Delay #1' value also needs exceeding." 020020 Units ="secs" 020100 Address =0x9ABF 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x58D6 000100 Cat0ID =0x1 020005 Title ="Fuel Lugging Mode O/L Max ECT" 020011 DescSize =0x5 020010 Desc ="LDEH" 020020 Units ="deg F" 020100 Address =0x97B3 020150 Flags =0x1 020200 Equation =X*2,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x7778 000100 Cat0ID =0x1 020005 Title ="Fuel Lugging Mode O/L Min ECT" 020011 DescSize =0x5 020010 Desc ="LDEL" 020020 Units ="deg F" 020100 Address =0x97B2 020150 Flags =0x1 020200 Equation =X*2,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x5348 000100 Cat0ID =0x1 020005 Title ="Fuel Lugging Mode O/L Min Load%" 020011 DescSize =0xFF 020010 Desc ="LDMH - When LOAD% is greater or equal to the sum of this value plus the 'Fuel Lugging Mode O/L Min Load% Hysteresis' (aka LDMHH) parameter value then one of the conditions required for the setting of the 'Lugging O/L Flag' (aka LDFLG) will have been met." 020020 Units ="load%" 020050 SizeInBits =0x10 020100 Address =0x97B6 020150 Flags =0x2 020200 Equation =X/327.68,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x83A 000100 Cat0ID =0x1 020005 Title ="Fuel Lugging Mode O/L Min Load% Hysteresis" 020011 DescSize =0x59 020010 Desc ="LDMHH - Hysteresis value for the 'Fuel Lugging Mode O/L Min Load%' (aka LDMH) parameter." 020020 Units ="load%" 020050 SizeInBits =0x10 020100 Address =0x97B8 020150 Flags =0x2 020200 Equation =X/327.68,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x392C 000100 Cat0ID =0x1 020005 Title ="Fuel Global Multiplier" 020011 DescSize =0xAB 020010 Desc ="OLMCL - A global multiplier that adjusts the desired A/F ratio when in open loop mode. \r\n\r\nMultiplier values less than 1 increase fuel, values greater than 1 reduce fuel." 020020 Units ="multiplier" 020050 SizeInBits =0x10 020100 Address =0x97BA 020150 Flags =0x2 020200 Equation =X/256,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x64D9 000100 Cat0ID =0x9 020005 Title ="Fuel Pump Monitor KOEO Test Delay" 020011 DescSize =0x9 020010 Desc ="V_FPMDLY" 020020 Units ="secs" 020100 Address =0x8ECE 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x504D 000100 Cat0ID =0x9 020005 Title ="Fuel Pump Monitor Test Delay" 020011 DescSize =0x8 020010 Desc ="V_FPMTM" 020020 Units ="secs" 020100 Address =0x8ECF 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x291E 000100 Cat0ID =0x9 020005 Title ="Fuel Pump Open Circuit Check" 020011 DescSize =0xA 020010 Desc ="OCCDT7 - " 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8F86 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x3A22 000100 Cat0ID =0x9 020005 Title ="Fuel Test Exit Delay" 020011 DescSize =0x9 020010 Desc ="VDLY8 - " 020020 Units ="secs" 020100 Address =0x8EB4 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x3A12 000100 Cat0ID =0x9 020005 Title ="Goose Idle Delay Time" 020011 DescSize =0x7 020010 Desc ="VISDL3" 020020 Units ="secs" 020100 Address =0x9E90 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x7FA1 000100 Cat0ID =0x9 020005 Title ="Goose Idle RPM" 020011 DescSize =0x7 020010 Desc ="ISLBND" 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x9E92 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x3DD 000100 Cat0ID =0x9 020005 Title ="Goose Minimum MAP Change" 020011 DescSize =0x4D 020010 Desc ="V_GOOSMP -The minimum MAP change to determine goose test has been undetaken." 020020 Units ="in Hg" 020100 Address =0x8EDF 020200 Equation =X/8,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x749 000100 Cat0ID =0x9 020005 Title ="Goose Minimum RPM Change" 020011 DescSize =0x4C 020010 Desc ="V_GOOSN -The minimum rpm change to determine goose test has been undetaken." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x8EE0 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x472F 000100 Cat0ID =0x9 020005 Title ="Goose Minimum TP Change" 020011 DescSize =0x53 020010 Desc ="V_GOOSTP - The minimum throttle change to determine goose test has been undetaken." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8EE4 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x236A 000100 Cat0ID =0x9 020005 Title ="Goose Spark" 020011 DescSize =0x9 020010 Desc ="V_GOOSPK" 020020 Units ="degrees" 020050 SizeInBits =0x10 020100 Address =0x8EE2 020150 Flags =0x3 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0xB1F 000100 Cat0ID =0x9 020005 Title ="Goose Test Desired RPM" 020011 DescSize =0x9 020010 Desc ="NGOOSE -" 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x9E94 020150 Flags =0x2 020200 Equation =X*8,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x68F1 000100 Cat0ID =0x9 020005 Title ="Goose Test Time" 020011 DescSize =0x75 020010 Desc ="V_GOOSEC - The maximum time allowed for the the operator to respond to the request for the throttle to be 'goosed'." 020020 Units ="secs" 020100 Address =0x8EDE 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5276 000100 Cat0ID =0xE 020005 Title ="Heated Windscreen Recognition Time Threshold" 020011 DescSize =0x5 020010 Desc ="HWRT" 020020 Units ="mSecs" 020050 SizeInBits =0x10 020100 Address =0x8C08 020150 Flags =0x2 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x5275 000100 Cat0ID =0xE 020005 Title ="Heated Windscreen Transition Time Threshold" 020011 DescSize =0x15 020010 Desc ="A3CTT - Do not edit." 020020 Units ="mSecs" 020050 SizeInBits =0x10 020100 Address =0x8C06 020150 Flags =0x2 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x1EF0 000100 Cat0ID =0x9 020005 Title ="HEGO Average Test Time Constant" 020011 DescSize =0xF2 020010 Desc ="VTCEGO - The time constant for the rolling average calculation of the 'HEGO Average' (aka EGOBAR) value during self test.\r\n\r\nLarger time constant values increase the time lag of the value being updated but reduce unwanted transients from it." 020020 Units ="secs" 020050 SizeInBits =0x10 020100 Address =0x8EDC 020150 Flags =0x2 020200 Equation =X/1024,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x3E39 000100 Cat0ID =0x5 020005 Title ="HEGO Min Switches Before Warm" 020011 DescSize =0x99 020010 Desc ="EGOCL1 - The number of HEGO switches required for the WARM_EGO_FLAG to be set providing the appropriate 'Warm HEGO Flag ....' delay times have been met." 020020 Units ="no." 020100 Address =0x9A98 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x583E 000100 Cat0ID =0xB 020005 Title ="HEGO Switch Time Delay" 020011 DescSize =0x8A 020010 Desc ="BYPLES - When the time since the last HEGO switch occurred exceeds this value then the 'Lack of HEGO Switching Flag' (aka LEGOFG) is set." 020020 Units ="secs" 020100 Address =0x93DE 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x4467 000100 Cat0ID =0x9 020005 Title ="HEGO Test Lean Time Wait" 020011 DescSize =0x7 020010 Desc ="VIPTM3" 020020 Units ="secs" 020100 Address =0x9E88 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x457B 000100 Cat0ID =0x9 020005 Title ="HEGO Test Min RPM" 020011 DescSize =0x6 020010 Desc ="VNMIN" 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x8EB2 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0xF6F 000100 Cat0ID =0x9 020005 Title ="HEGO Test Min Time at C/L ECT" 020011 DescSize =0x92 020010 Desc ="VEGOTM - The minimum time after the minimum coolant temperature for closed loop operation has been reached before the HEGO test can be performed." 020020 Units ="secs" 020100 Address =0x8F00 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x651F 000100 Cat0ID =0x9 020005 Title ="HEGO Test Rich Time Wait" 020011 DescSize =0x7 020010 Desc ="VIPTM4" 020020 Units ="secs" 020100 Address =0x942F 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x7EAA 000100 Cat0ID =0x9 020005 Title ="HEGO Test Switch Time Delay" 020011 DescSize =0x7 020010 Desc ="VIPTM2" 020020 Units ="secs" 020100 Address =0x8FB2 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x47DC 000100 Cat0ID =0x7 020005 Title ="High Speed Fan High Load Max MPH" 020011 DescSize =0x59 020010 Desc ="HSFVS - The maximum mph for the 'High Speed Fan High Load On Temp' parameter to be used." 020020 Units ="mph" 020100 Address =0x9421 020200 Equation =X/2,TH|0|0|0|0| 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x1F86 000100 Cat0ID =0x7 020005 Title ="High Speed Fan High Load Min Load" 020011 DescSize =0x5B 020010 Desc ="HSFLOD - The minimum load for the 'High Speed Fan High Load On Temp' parameter to be used." 020020 Units ="load" 020050 SizeInBits =0x10 020100 Address =0x9422 020150 Flags =0x2 020200 Equation =X/327.68,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x7E86 000100 Cat0ID =0x7 020005 Title ="High Speed Fan High Load Min RPM" 020011 DescSize =0x5A 020010 Desc ="HSFRPM - The minimum rpm for the 'High Speed Fan High Load On Temp' parameter to be used." 020020 Units ="rpm" 020100 Address =0x9420 020200 Equation =X*16,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x5F9A 000100 Cat0ID =0x7 020005 Title ="High Speed Fan High Load On Temp" 020011 DescSize =0x172 020010 Desc ="HSFEC1 - A lower coolant temperature than which the high speed fan normally turns on, used when minimum rpm, load and maximum mph criteria are met. Typically set 12 deg F higher than the 'Low Speed Fan On Temp' parameter. The associated conditional parameters are:\r\n\r\nHigh Speed Fan High Load Max MPH\r\nHigh Speed Fan High Load Min Load\r\nHigh Speed Fan High Load Min RPM" 020020 Units ="deg F" 020100 Address =0x941E 020150 Flags =0x1 020200 Equation =X*2,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x5855 000100 Cat0ID =0x9 020005 Title ="High Speed Fan Open Circuit Check" 020011 DescSize =0xA 020010 Desc ="OCCDT3 - " 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8F80 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5731 000100 Cat0ID =0x9 020005 Title ="High Speed Fan Open Circuit Check Time" 020011 DescSize =0x7 020010 Desc ="VDLHED" 020020 Units ="secs" 020100 Address =0x8F18 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x3071 000100 Cat0ID =0x7 020005 Title ="High Speed Fan Normal On Temp" 020011 DescSize =0xA2 020010 Desc ="HSFEC2 - The coolant temperature at which the high speed fan normally turns on. Typically set 8 deg F higher than 'High Speed Fan High Load On Temp' temperature." 020020 Units ="deg F" 020100 Address =0x941F 020150 Flags =0x1 020200 Equation =X*2,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x874 000100 Cat0ID =0x7 020005 Title ="High Speed Fan Temperature Hysteresis" 020011 DescSize =0x27 020010 Desc ="HSFHYS - Typically set to 4 degrees F." 020020 Units ="deg F" 020100 Address =0x9415 020200 Equation =X*2,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0xCCF 000100 Cat0ID =0x9 020005 Title ="High Speed Fan Test Throttle Depress Time" 020011 DescSize =0x60 020010 Desc ="VHFNTM - The minimum time to hold the throttle open for to enable the KOEO high speed fan test." 020020 Units ="secs" 020100 Address =0x8F1A 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x7229 000100 Cat0ID =0x5 020005 Title ="Hot Start Min ECT" 020011 DescSize =0xC2 020010 Desc ="CTHIGH - The minimum ECT for a hot start condition to be recognised.\r\n\r\nThis is also the minimum ECT in order for the 'CT Neutral Timer' (aka CTNTMR) to count up (other conditions permitting). " 020020 Units ="deg F" 020100 Address =0x9E5E 020150 Flags =0x1 020200 Equation =X*2,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x570B 000100 Cat0ID =0x6 020005 Title ="Idle Airflow Decrement for A/C" 020011 DescSize =0x6F 020010 Desc ="DACPPM - The reduction in predicted idle airflow through the ISC valve required when the aircon is turned off." 020020 Units ="lb/min" 020050 SizeInBits =0x10 020100 Address =0x905E 020150 Flags =0x2 020200 Equation =X/2048,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x570A 000100 Cat0ID =0x6 020005 Title ="Idle Airflow Increment for A/C" 020011 DescSize =0x6C 020010 Desc ="ACPPM - The increase in predicted idle airflow through the ISC valve required when the aircon is turned on." 020020 Units ="lb/min" 020050 SizeInBits =0x10 020100 Address =0x905C 020150 Flags =0x2 020200 Equation =X/2048,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5774 000100 Cat0ID =0x6 020005 Title ="Idle Airflow Increment for Heated Windcreen" 020011 DescSize =0x77 020010 Desc ="HWPPM - The increase in predicted idle airflow through the ISC valve required when the heated windscreen is turned on." 020020 Units ="lb/min" 020050 SizeInBits =0x10 020100 Address =0x93B4 020150 Flags =0x2 020200 Equation =X/2048,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x570C 000100 Cat0ID =0x6 020005 Title ="Idle Airflow Increment for Power Steering" 020011 DescSize =0x8A 020010 Desc ="PSPPM - The increase in predicted idle airflow through the ISC valve required when the power steering places addition load on the engine." 020020 Units ="lb/min" 020050 SizeInBits =0x10 020100 Address =0x9060 020150 Flags =0x2 020200 Equation =X/2048,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x693D 000100 Cat0ID =0x6 020005 Title ="Idle GPAS Clip Limit" 020011 DescSize =0x5A 020010 Desc ="ISCLPD - If the base target idle speed values have been altered then adjust this to suit." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x9052 020150 Flags =0x2 020200 Equation =X*8,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x43E5 000100 Cat0ID =0x6 020005 Title ="Idle GPAS Minimum Time" 020011 DescSize =0x80 020010 Desc ="CRKTIM - The minimum time in run mode that must be exceeded in order for the 'Idle GPAS Clip Limit' (aka ISCLPD) to be invoked." 020020 Units ="secs" 020100 Address =0x97C6 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x62ED 000100 Cat0ID =0x6 020005 Title ="Idle RPM Adder for A/C" 020011 DescSize =0x89 020010 Desc ="DNAC - Adds rpm to 'Desired Idle RPM' when aircon clutch is engaged, used to compensate for the additional load the compressor imposes." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x9050 020150 Flags =0x2 020200 Equation =X*8,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x890 000100 Cat0ID =0x6 020005 Title ="Idle RPM Adder for A/C Time" 020011 DescSize =0x54 020010 Desc ="DACTM - Time to maintain idle aircon rpm adder after aircon clutch has disengaged." 020020 Units ="secs" 020050 SizeInBits =0x10 020100 Address =0x9062 020150 Flags =0x2 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x51A2 000100 Cat0ID =0x6 020005 Title ="Idle RPM Adder for Power Steering" 020011 DescSize =0x82 020010 Desc ="DNPOWS - Adds rpm to 'Desired Idle RPM' when power steering is engaged, used to compensate for the additional load this imposes." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x9064 020150 Flags =0x2 020200 Equation =X*8,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x40BB 000100 Cat0ID =0x6 020005 Title ="Idle RPM for Heated Windscreen" 020011 DescSize =0x59 020010 Desc ="HWRPM - Minimum idle rpm in neutral when the heated windscreen is on for the first time." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x8C04 020150 Flags =0x2 020200 Equation =X*8,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x2D91 000100 Cat0ID =0x6 020005 Title ="Idle Speed Drive" 020011 DescSize =0xE6 020010 Desc ="DRBASE - Base target idle speed in drive before adders. If altered, adjust the 'Max RPM for Idle Flag' (aka IDLRPM) parameter too. The 'ISC Gain vs RPM Error' (aka FN824) parameter might also need adjusting too (to be confirmed)." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x904C 020150 Flags =0x2 020200 Equation =X*8,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x5583 000100 Cat0ID =0x6 020005 Title ="Idle Speed Neutral" 020011 DescSize =0xE8 020010 Desc ="NUBASE - Base target idle speed in neutral before adders. If altered, adjust the 'Max RPM for Idle Flag' (aka IDLRPM) parameter too. The 'ISC Gain vs RPM Error' (aka FN824) parameter might also need adjusting too (to be confirmed)." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x904A 020150 Flags =0x2 020200 Equation =X*8,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x22BB 000100 Cat0ID =0x6 020005 Title ="Idle Startup Adder Time" 020011 DescSize =0x6E 020010 Desc ="TKDTM - Time since exiting crank when 'ISC Startup Adder' (aka FN826A) is used as a 'Desired Idle RPM' adder." 020020 Units ="secs" 020100 Address =0x9066 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x5CD6 000100 Cat0ID =0x9 020005 Title ="IDM Error Threshold" 020011 DescSize =0xA 020010 Desc ="IDMLVL - " 020020 Units ="" 020100 Address =0x8F30 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x1119 000100 Cat0ID =0x9 020005 Title ="IDM Error Upcount" 020011 DescSize =0x9 020010 Desc ="IDMUP - " 020020 Units ="" 020100 Address =0x8F46 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x529 000100 Cat0ID =0x7 020005 Title ="Ignition Degrees Per PIP" 020011 DescSize =0x6B 020010 Desc ="DEGPIP - The number of crank degrees per PIP interval. 90 = 8 cylinder, 120 = 6 cylinder, 180 = 4 cylinder" 020020 Units ="degrees" 020050 SizeInBits =0x10 020100 Address =0x9AAA 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x63CB 000100 Cat0ID =0x1 020005 Title ="Initial FAM" 020011 DescSize =0x5 020010 Desc ="IFAM" 020020 Units ="lb/min" 020050 SizeInBits =0x10 020100 Address =0x9E80 020150 Flags =0x2 020200 Equation =X/2048,TH|0|0|0|0| 020210 DecimalPl =0x6 %%END%% %%CONSTANT%% 000002 UniqueID =0x4661 000100 Cat0ID =0xB 020005 Title ="Initial TP" 020011 DescSize =0x8A 020010 Desc ="RATIV - Closed throttle value used by the eec if either the TPS has failed, is less than 'TPS Max' value or greater than 'TPS Max' value." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8C02 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x46A1 000100 Cat0ID =0x7 020005 Title ="Injector Fire Method" 020011 DescSize =0x2A 020010 Desc ="OUTINJ - 1 = sequential, 2 = simultaneous" 020020 Units ="n/a" 020100 Address =0x9AB1 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x78E7 000100 Cat0ID =0x7 020005 Title ="Injector High Slope" 020011 DescSize =0x1CA 020010 Desc ="AHISL - The injector primary fuel slope, used in conjunction with the 'Injector Low Slope' (aka ALOSL) to calculate injection pulsewidths greater than those using the low slope alone. Set to the mass flow rate of an individual fuel injector. When altered, the following parameters will need adjusting too;\r\n\r\n'Injector Low Slope' (aka ALOSL)\r\n'Injector Breakpoint' (aka FN389)\r\n'Injector Offset vs Voltage' (aka FN367)\r\n'Cranking Fuel PW vs ECT' (aka FN348)" 020020 Units ="lb/hr" 020050 SizeInBits =0x10 020100 Address =0x901E 020150 Flags =0x2 020200 Equation =X/582.535278,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x6047 000100 Cat0ID =0x7 020005 Title ="Injector Low Slope" 020011 DescSize =0x338 020010 Desc ="ALOSL - Used to calculate the injection pulsewidth during cranking and short pulsewidths. Set to a value larger than actual injector size to compensate for non linear opening at short durations. Typically 1.33 * 'Injector High Slope' (aka AHISL) for 19 lb/hr injectors reducing to 1.08 * 'Injector High Slope' (aka AHISL) for 83 lb/hr injectors. When altered, the following parameters will need adjusting too;\r\n\r\n'Injector Breakpoint' (aka FN389)\r\n'Injector Offset vs Voltage' (aka FN367)\r\n'Cranking Fuel PW vs ECT' (aka FN3\r\n\r\nAn alternative is to set this parameter to the same value as the 'Injector High Slope' (aka AHISL) in which case the 'Injector Breakpoint' (aka FN389) parameter is not used. The 'Injector Offset vs Voltage' (aka FN367) is critical in getting accurate fuel pulsewidths with this method of tuning." 020020 Units ="lb/hr" 020050 SizeInBits =0x10 020100 Address =0x901C 020150 Flags =0x2 020200 Equation =X/582.535278,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x6E2F 000100 Cat0ID =0x1 020005 Title ="Injector Timing Delay" 020011 DescSize =0xB5 020010 Desc ="IDKADD - Injector timing delay added to the result of the 'Injector Timing' (aka FN1315) lookup following multiplication by the 'Injector Timing Multiplier (aka IDKMUL) parameter. " 020020 Units ="crank deg" 020050 SizeInBits =0x10 020100 Address =0x8FFE 020150 Flags =0x2 020200 Equation =X/16,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x6D7B 000100 Cat0ID =0x1 020005 Title ="Injector Timing Multiplier" 020011 DescSize =0x58 020010 Desc ="IDKMUL - A multiplier of the result of the 'Injector Timing' (aka FN1315) table lookup." 020020 Units ="multiplier" 020050 SizeInBits =0x10 020100 Address =0x8FFC 020150 Flags =0x2 020200 Equation =X/32768,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x591E 000100 Cat0ID =0x7 020005 Title ="Injector Timing Time Constant" 020011 DescSize =0xE3 020010 Desc ="TCINJD - The time constant for the rolling average calculation of the 'Injector Delay' (aka INJDLY) value.\r\n\r\nLarger time constant values increase the time lag of the value being updated but reduce unwanted transients from it." 020020 Units ="secs" 020050 SizeInBits =0x10 020100 Address =0x9800 020150 Flags =0x2 020200 Equation =X/1024,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x29FD 000100 Cat0ID =0x7 020005 Title ="Injector Timing Value at Idle" 020011 DescSize =0x7C 020010 Desc ="MIDTV - Injector timing value used when in drive and the 'Enable Special Injector Timing at Idle' (aka CIDRSW) flag is set." 020020 Units ="crank deg" 020100 Address =0x9ABB 020200 Equation =X*4,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x389B 000100 Cat0ID =0x7 020005 Title ="Injector Timing Value for MFA" 020011 DescSize =0x105 020010 Desc ="MINTV - The injector timing value used when in fuel economy mode, it overrides all other injector timing parameters. Can indicate the start or end timing point of the injector pulse depending on the setting of the 'Injector Timing Edge' (aka INJREF) parameter." 020020 Units ="crank deg" 020100 Address =0x9ABA 020200 Equation =X*4,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x25F 000100 Cat0ID =0x7 020005 Title ="Injector Timing Value in Neutral" 020011 DescSize =0xC0 020010 Desc ="CINTV - Injector timing value used when the 'Enable Special Injector Timing in Neutral' (aka CINTSW) flag is set providing the startup delay for fixed injector timing conditions have expired." 020020 Units ="crank deg" 020100 Address =0x8FDF 020200 Equation =X*4,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x501F 000100 Cat0ID =0x7 020005 Title ="Injectors Per Output Port" 020011 DescSize =0x3C 020010 Desc ="INJOUT - The number of injectors fired by each output port." 020020 Units ="no." 020100 Address =0x9AAF 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x1478 000100 Cat0ID =0x7 020005 Title ="Intake Air Control Valve Open RPM" 020011 DescSize =0x7B 020010 Desc ="NIAC - RPM at which the intake manifold air control valve is opened. Requires 'Auxillary Hardware Present' to be set to 3." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x8E68 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x2EFD 000100 Cat0ID =0x7 020005 Title ="Intake Air Control Valve Open RPM Hysteresis" 020011 DescSize =0x7D 020010 Desc ="NIACH - Subtracted from 'Intake Air Control Valve Open RPM' to establish rpm at which valve closes. Typically set at 500rpm." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x8E6A 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x5709 000100 Cat0ID =0x6 020005 Title ="ISC Air Drive To Neutral" 020011 DescSize =0x6 020010 Desc ="DNPPM" 020020 Units ="lb/min" 020050 SizeInBits =0x10 020100 Address =0x905A 020150 Flags =0x2 020200 Equation =X/2048,TH|0|0|0|0| 020210 DecimalPl =0x6 %%END%% %%CONSTANT%% 000002 UniqueID =0x5708 000100 Cat0ID =0x6 020005 Title ="ISC Air Neutral To Drive" 020011 DescSize =0x6 020010 Desc ="NDPPM" 020020 Units ="lb/min" 020050 SizeInBits =0x10 020100 Address =0x9058 020150 Flags =0x2 020200 Equation =X/2048,TH|0|0|0|0| 020210 DecimalPl =0x6 %%END%% %%CONSTANT%% 000002 UniqueID =0x560B 000100 Cat0ID =0x6 020005 Title ="ISC C/L RPM Correction Airmass Max" 020011 DescSize =0x5B 020010 Desc ="PSIBRM - The maximum value of the 'ISC C/L RPM Correction Airmass' (aka IPSIBR) permitted." 020020 Units ="lb/min" 020050 SizeInBits =0x10 020100 Address =0x902A 020150 Flags =0x2 020200 Equation =X/4096,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x560C 000100 Cat0ID =0x6 020005 Title ="ISC C/L RPM Correction Airmass Min" 020011 DescSize =0x5B 020010 Desc ="PSIBRN - The minimum value of the 'ISC C/L RPM Correction Airmass' (aka IPSIBR) permitted." 020020 Units ="lb/min" 020050 SizeInBits =0x10 020100 Address =0x902C 020150 Flags =0x3 020200 Equation =X/4096,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x127 000100 Cat0ID =0x9 020005 Title ="ISC C/L RPM Correction Airmass Test Max" 020011 DescSize =0x6C 020010 Desc ="VSIBRM - The maximum value of the 'ISC C/L RPM Correction Airmass' (aka IPSIBR) permitted during self test." 020020 Units ="lb/min" 020050 SizeInBits =0x10 020100 Address =0x9E96 020150 Flags =0x3 020200 Equation =X/4096,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x29E4 000100 Cat0ID =0x9 020005 Title ="ISC C/L RPM Correction Test Rate" 020011 DescSize =0x66 020010 Desc ="V860 - Substitution value used instead of 'ISC C/L RPM Correction Rate' value when in self test mode." 020020 Units ="rate" 020050 SizeInBits =0x10 020100 Address =0x9E9E 020150 Flags =0x2 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x1BFE 000100 Cat0ID =0x9 020005 Title ="ISC C/L RPM Correction Airmass Test Min" 020011 DescSize =0x6C 020010 Desc ="VSIBRN - The minimum value of the 'ISC C/L RPM Correction Airmass' (aka IPSIBR) permitted during self test." 020020 Units ="lb/min" 020050 SizeInBits =0x10 020100 Address =0x9E98 020150 Flags =0x3 020200 Equation =X/4096,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x58D8 000100 Cat0ID =0x9 020005 Title ="ISC High RPM Test Delay Time" 020011 DescSize =0x7 020010 Desc ="VISDL1" 020020 Units ="secs" 020100 Address =0x9E8A 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x787C 000100 Cat0ID =0x9 020005 Title ="ISC High RPM Test RPM" 020011 DescSize =0x7 020010 Desc ="ISUBND" 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x9E8E 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x563D 000100 Cat0ID =0x6 020005 Title ="ISC Gain Associated With The Desired DASPOT Airflow" 020011 DescSize =0x7 020010 Desc ="DASPTK" 020020 Units ="lb/min per TP count" 020050 SizeInBits =0x10 020100 Address =0x9032 020150 Flags =0x2 020200 Equation =X/1048576,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x62AD 000100 Cat0ID =0x6 020005 Title ="ISC Gain For Overspeed in Drive" 020011 DescSize =0x7E 020010 Desc ="KPSIDD - Multiplied by engine speed error and the 'ISC Gain vs RPM Error' lookup result, used as input in IPSIBR calculation." 020020 Units ="lb/min per rpm" 020050 SizeInBits =0x10 020100 Address =0x9028 020150 Flags =0x2 020200 Equation =X/4194304,TH|0|0|0|0| 020210 DecimalPl =0x6 %%END%% %%CONSTANT%% 000002 UniqueID =0x69C2 000100 Cat0ID =0x6 020005 Title ="ISC Gain For Overspeed in Neutral" 020011 DescSize =0x7E 020010 Desc ="KPSIND - Multiplied by engine speed error and the 'ISC Gain vs RPM Error' lookup result, used as input in IPSIBR calculation." 020020 Units ="lb/min per rpm" 020050 SizeInBits =0x10 020100 Address =0x9024 020150 Flags =0x2 020200 Equation =X/4194304,TH|0|0|0|0| 020210 DecimalPl =0x6 %%END%% %%CONSTANT%% 000002 UniqueID =0x551B 000100 Cat0ID =0x9 020005 Title ="ISC Gain For Overspeed in Self Test" 020011 DescSize =0x51 020010 Desc ="VPSIND - Multiplied by engine speed error, used as input in IPSIBR calculation. " 020020 Units ="lb/min per rpm" 020050 SizeInBits =0x10 020100 Address =0x9E9A 020150 Flags =0x2 020200 Equation =X/4194304,TH|0|0|0|0| 020210 DecimalPl =0x6 %%END%% %%CONSTANT%% 000002 UniqueID =0x7619 000100 Cat0ID =0x6 020005 Title ="ISC Gain For Underspeed in Drive" 020011 DescSize =0x7E 020010 Desc ="KPSIDU - Multiplied by engine speed error and the 'ISC Gain vs RPM Error' lookup result, used as input in IPSIBR calculation." 020020 Units ="lb/min per rpm" 020050 SizeInBits =0x10 020100 Address =0x9026 020150 Flags =0x2 020200 Equation =X/4194304,TH|0|0|0|0| 020210 DecimalPl =0x6 %%END%% %%CONSTANT%% 000002 UniqueID =0x5516 000100 Cat0ID =0x6 020005 Title ="ISC Gain For Underspeed in Neutral" 020011 DescSize =0x7E 020010 Desc ="KPSINU - Multiplied by engine speed error and the 'ISC Gain vs RPM Error' lookup result, used as input in IPSIBR calculation." 020020 Units ="lb/min per rpm" 020050 SizeInBits =0x10 020100 Address =0x9022 020150 Flags =0x2 020200 Equation =X/4194304,TH|0|0|0|0| 020210 DecimalPl =0x6 %%END%% %%CONSTANT%% 000002 UniqueID =0x1AA0 000100 Cat0ID =0x9 020005 Title ="ISC Gain For Underspeed in Self Test" 020011 DescSize =0x51 020010 Desc ="VPSINU - Multiplied by engine speed error, used as input in IPSIBR calculation. " 020020 Units ="lb/min per rpm" 020050 SizeInBits =0x10 020100 Address =0x9E9C 020150 Flags =0x2 020200 Equation =X/4194304,TH|0|0|0|0| 020210 DecimalPl =0x6 %%END%% %%CONSTANT%% 000002 UniqueID =0x56A4 000100 Cat0ID =0xA 020005 Title ="ISC KAM Update Rate" 020011 DescSize =0x7 020010 Desc ="UPDATM" 020020 Units ="clock ticks" 020100 Address =0x9047 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x560E 000100 Cat0ID =0x6 020005 Title ="ISC Min Airflow" 020011 DescSize =0x7 020010 Desc ="DEBYCP" 020020 Units ="lb/min" 020050 SizeInBits =0x10 020100 Address =0x9030 020150 Flags =0x2 020200 Equation =X/4096,TH|0|0|0|0| 020210 DecimalPl =0x6 %%END%% %%CONSTANT%% 000002 UniqueID =0x5640 000100 Cat0ID =0x6 020005 Title ="ISC RPM Control Deadband" 020011 DescSize =0x1C7 020010 Desc ="RPMCTL - This parameter is used by two different sections of the idle control software.\r\n\r\na) If the rpm is less than the desired idle rpm plus this parameter then ISC closed loop rpm control is allowed providing the other conditions for rpm control are satisfied.\r\n\r\nb) If the rpm is less than the desired idle rpm minus this parameter when the ISC dutycycle is greater than 98% then part of the idle routine is skipped (actual routine to be determined)" 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x9038 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x5642 000100 Cat0ID =0x6 020005 Title ="ISC RPM Control Min Speed" 020011 DescSize =0xA4 020010 Desc ="MINMPH - If the vehicle speed is less than this parameter then ISC closed loop rpm control is allowed providing the other conditions for rpm control are satisfied." 020020 Units ="mph" 020100 Address =0x903C 020200 Equation =X/2,TH|0|0|0|0| 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x5671 000100 Cat0ID =0x6 020005 Title ="ISC RPM Deadband" 020011 DescSize =0x7 020010 Desc ="RPMDED" 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x903E 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x56A3 000100 Cat0ID =0x6 020005 Title ="ISC RPM Deadband Time" 020011 DescSize =0x8F 020010 Desc ="UPDISC - The minimum time the rpm must be at the desired idle rpm ( + or - the 'ISC RPM Deadband' value) in order for ISC KAM update to occur." 020020 Units ="secs" 020100 Address =0x9046 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x5641 000100 Cat0ID =0x6 020005 Title ="ISC RPM Deviation Allowed" 020011 DescSize =0xD3 020010 Desc ="NDIF - The maximum change in rpm over the time period specified by the 'ISC RPM Deviation Time' (aka ISCTM).\r\n\r\nToo small a value will prevent closed loop idle control. Too large a value will negate any effect." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x903A 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x5674 000100 Cat0ID =0x6 020005 Title ="ISC RPM Deviation RPM" 020011 DescSize =0x6 020010 Desc ="ISCTM" 020020 Units ="secs" 020100 Address =0x9043 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x7C26 000100 Cat0ID =0x9 020005 Title ="ISC Self Test Dutycycle Multiplier" 020011 DescSize =0x73 020010 Desc ="V820A - Replacement value for 'ISC Dutycycle Multiplier vs Load' (aka FN820B) lookup result used during self test." 020020 Units ="multiplier" 020100 Address =0x9EA0 020200 Equation =X/128,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x540C 000100 Cat0ID =0x5 020005 Title ="Key On Update Flag Reset Delay" 020011 DescSize =0x73 020010 Desc ="TKYON4 - If the 'Time Since Start' is greater than this value then the 'Key On Update Flag' (aka BPKFLG) is reset." 020020 Units ="secs" 020100 Address =0x9486 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x7A67 000100 Cat0ID =0x5 020005 Title ="Key On Update Max Time" 020011 DescSize =0x7 020010 Desc ="TKYON3" 020020 Units ="secs" 020050 SizeInBits =0x10 020100 Address =0x9484 020150 Flags =0x2 020200 Equation =X/1024,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x501 000100 Cat0ID =0x5 020005 Title ="Key On Update Min Time" 020011 DescSize =0x7 020010 Desc ="TKYON2" 020020 Units ="secs" 020050 SizeInBits =0x10 020100 Address =0x9482 020150 Flags =0x2 020200 Equation =X/1024,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x263D 000100 Cat0ID =0x5 020005 Title ="Keypower Scaling Factor" 020011 DescSize =0x3D 020010 Desc ="KSF - Used in the instantaneous battery voltage calculation." 020020 Units ="muliplier" 020050 SizeInBits =0x10 020100 Address =0x9E72 020150 Flags =0x2 020200 Equation =X/8192,TH|0|0|0|0| 020210 DecimalPl =0x5 %%END%% %%CONSTANT%% 000002 UniqueID =0x5BD1 000100 Cat0ID =0x2 020005 Title ="Knock Advance Limit" 020011 DescSize =0x56 020010 Desc ="ADVLIM - The amount of spark advance above 'Spark Advance Final' (aka SAF) permitted." 020020 Units ="deg adv" 020100 Address =0x9461 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x7DDF 000100 Cat0ID =0x2 020005 Title ="Knock Cylinder Strategy" 020011 DescSize =0x1C2 020010 Desc ="KNKCYL - Determines whether an individual or multi cylinder knock strategy is to be used.\r\n\r\nSet to '1' to for a multi cylinder knock strategy. This will result in all cylinders being retarded by the same amount when spark retard for knock is applied.\r\n\r\nSet equal to the number of cylinders for an individual cylinder knock strategy. This will result in each cylinder being retarded by the a different amount when spark retard for knock is applied." 020020 Units ="" 020100 Address =0x9478 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x4710 000100 Cat0ID =0x2 020005 Title ="Knock Maximum Retard" 020011 DescSize =0x3C 020010 Desc ="RETLIM - The maximum spark retard pulled when knock occurs." 020020 Units ="deg adv" 020100 Address =0x9460 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x511 000100 Cat0ID =0x2 020005 Title ="Knock Min ECT" 020011 DescSize =0x3F 020010 Desc ="ECTNOK - The minimum ECT for the knock strategy to be enabled." 020020 Units ="deg F" 020100 Address =0x946C 020150 Flags =0x1 020200 Equation =X*2,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x747A 000100 Cat0ID =0x2 020005 Title ="Knock Min Load" 020011 DescSize =0x40 020010 Desc ="LODNOK - The minimum Load for the knock strategy to be enabled." 020020 Units ="load" 020050 SizeInBits =0x10 020100 Address =0x946A 020150 Flags =0x2 020200 Equation =X/327.68,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x5C06 000100 Cat0ID =0x2 020005 Title ="Knock Min RPM" 020011 DescSize =0x3F 020010 Desc ="RPMMIN - The minimum rpm for the knock strategy to be enabled." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x9468 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x7281 000100 Cat0ID =0x9 020005 Title ="Knock Threshold Pulse Time" 020011 DescSize =0x6 020010 Desc ="V_KTS" 020020 Units ="clock ticks" 020100 Address =0x8EE7 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x5C3B 000100 Cat0ID =0x2 020005 Title ="Knock Threshold Window Position Delay" 020011 DescSize =0xB2 020010 Desc ="WOPEN - The minimum delay after the rising edge of the PIP before the KTS pulse will be output. Added to the result of the 'Knock Threshold Window Position' (aka FN145A) lookup." 020020 Units ="PIP period fraction" 020050 SizeInBits =0x10 020100 Address =0x9470 020150 Flags =0x2 020200 Equation =X/32768,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5C3C 000100 Cat0ID =0x2 020005 Title ="Knock Threshold Window Time Min" 020011 DescSize =0x2D 020010 Desc ="WINLEN - The minimum width of the KTS pulse." 020020 Units ="clock ticks" 020050 SizeInBits =0x10 020100 Address =0x9472 020150 Flags =0x2 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x5C6D 000100 Cat0ID =0x2 020005 Title ="Knock Window Closed Time" 020011 DescSize =0x3C 020010 Desc ="WINCLD - The number of PIPs the knock window is closed for." 020020 Units ="no." 020100 Address =0x9479 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x5C6A 000100 Cat0ID =0x2 020005 Title ="Knock Window Maximum RPM" 020011 DescSize =0x39 020010 Desc ="RPMCNL - The rpm above which the knock window is closed." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x9474 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x7B38 000100 Cat0ID =0x1 020005 Title ="Load Min for C/L" 020011 DescSize =0x6 020010 Desc ="LOLOD" 020020 Units ="load" 020050 SizeInBits =0x10 020100 Address =0x9A9A 020150 Flags =0x2 020200 Equation =X/327.68,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x7FF3 000100 Cat0ID =0x1 020005 Title ="Load Min for C/L Hysteresis" 020011 DescSize =0x7 020010 Desc ="LOLODH" 020020 Units ="load" 020050 SizeInBits =0x10 020100 Address =0x9A9C 020150 Flags =0x2 020200 Equation =X/327.68,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x5676 000100 Cat0ID =0x1 020005 Title ="Load% Min for O/L Hysteresis" 020011 DescSize =0xC6 020010 Desc ="HLODH - Defines the amount LOAD% needs to be below the 'Load% Min for O/L vs ECT' (aka FN320A) table lookup result in order for the 'Inhibit High Load Timer Flag' to be cleared once it's been set." 020020 Units ="load%" 020050 SizeInBits =0x10 020100 Address =0x9A9E 020150 Flags =0x2 020200 Equation =X/327.68,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x5372 000100 Cat0ID =0x5 020005 Title ="Low Battery Voltage" 020011 DescSize =0x5E 020010 Desc ="LOWBAT - Voltage the eec considers too low for accurate operation of some sensors/actuators. " 020020 Units ="volts" 020100 Address =0x8E9F 020200 Equation =X/16,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x5675 000100 Cat0ID =0x6 020005 Title ="Low Load" 020011 DescSize =0x9C 020010 Desc ="LOWLOD - Used in \"ISC Mode Flag\" selection. If set to zero, along with the \"A/C Low Load Adder\", the \"ISC Mode Flag\" is always set to 2 (rpm lockout mode)." 020020 Units ="load" 020100 Address =0x9044 020200 Equation =X*64/327.68,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x6370 000100 Cat0ID =0x6 020005 Title ="Low Load A/C Adder" 020011 DescSize =0x8E 020010 Desc ="ACLOD - Added to \"Low Load\" when A/C is on. If set to zero, along with \"Low Load\", the \"ISC Mode Flag\" is always set to 2 (rpm lockout mode)." 020020 Units ="load" 020100 Address =0x9045 020200 Equation =X*64/327.68,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x7BD3 000100 Cat0ID =0x7 020005 Title ="Low Speed Fan Min Time Before High Speed" 020011 DescSize =0x67 020010 Desc ="EDFTM - The minimum delay before turning on the high speed fan after the turning on the low speed fan." 020020 Units ="secs" 020100 Address =0x9419 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x407F 000100 Cat0ID =0x7 020005 Title ="Low Speed Fan On Temp" 020011 DescSize =0x46 020010 Desc ="LSFECT - The coolant temperature at which the low speed fan turns on." 020020 Units ="deg F" 020100 Address =0x9414 020150 Flags =0x1 020200 Equation =X*2,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x5D8D 000100 Cat0ID =0x7 020005 Title ="Low Speed Fan On Temp Hysteresis" 020011 DescSize =0x27 020010 Desc ="LSFHYS - Typically set to 4 degrees F." 020020 Units ="deg F" 020100 Address =0x9416 020150 Flags =0x1 020200 Equation =X*2,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x3689 000100 Cat0ID =0x9 020005 Title ="Low Speed Fan Open Circuit Check" 020011 DescSize =0xA 020010 Desc ="OCCDT8 - " 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8F88 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x3D0B 000100 Cat0ID =0x9 020005 Title ="Low Speed Fan Open Circuit Check Time" 020011 DescSize =0x7 020010 Desc ="VDLEDF" 020020 Units ="secs" 020100 Address =0x8F17 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x46A2 000100 Cat0ID =0x9 020005 Title ="Low Speed Fan Test Throttle Depress Time" 020011 DescSize =0x5F 020010 Desc ="VLFNTM - The minimum time to hold the throttle open for to enable the KOEO low speed fan test." 020020 Units ="secs" 020100 Address =0x8F19 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5378 000100 Cat0ID =0xB 020005 Title ="MAF Failure Flag Counter Hysteresis" 020011 DescSize =0x7 020010 Desc ="MFMHYS" 020020 Units ="counts" 020100 Address =0x8EA6 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x24C8 000100 Cat0ID =0x9 020005 Title ="MAF KOEO Min" 020011 DescSize =0x7 020010 Desc ="VMAFO1" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8F62 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x3BD9 000100 Cat0ID =0x9 020005 Title ="MAF KOER Max" 020011 DescSize =0x7 020010 Desc ="VMAFR2" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8F66 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x531C 000100 Cat0ID =0x9 020005 Title ="MAF KOER Min" 020011 DescSize =0x7 020010 Desc ="VMAFR1" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8F64 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x100D 000100 Cat0ID =0x4 020005 Title ="MAF Max RPM for Max Volts Test" 020011 DescSize =0x7B 020010 Desc ="VMARPM - If the rpm is greater than this value then the MAF voltage is not checked against the 'MAF Max Volts' parameter." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x8F6C 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x6456 000100 Cat0ID =0x4 000101 Cat1ID =0x9 020005 Title ="MAF Max Volts" 020011 DescSize =0x5D 020010 Desc ="VMAMAX - Limit indicating short circuit that is checked during normal running and KOEO test." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8F68 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x6365 000100 Cat0ID =0x3 020005 Title ="MAF Min Airmass Clip" 020011 DescSize =0x6 020010 Desc ="MINAM" 020020 Units ="lb/min" 020050 SizeInBits =0x10 020100 Address =0x9E74 020150 Flags =0x2 020200 Equation =X/1024,TH|0|0|0|0| 020210 DecimalPl =0x6 %%END%% %%CONSTANT%% 000002 UniqueID =0x53 000100 Cat0ID =0x4 020005 Title ="MAF Min Volts" 020011 DescSize =0x4E 020010 Desc ="VMAMIN - Limit indicating open circuit that is checked during normal running." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8F6A 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x30A 000100 Cat0ID =0x9 020005 Title ="MAF PIP Limit" 020011 DescSize =0xB 020010 Desc ="VMAFPIPLMT" 020020 Units ="mSecs" 020050 SizeInBits =0x10 020100 Address =0x8F60 020150 Flags =0x2 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x5FE2 000100 Cat0ID =0x7 020005 Title ="Manifold Air Charge Fraction" 020011 DescSize =0x94 020010 Desc ="FILFRC - Ratio of instantaneous air charge / filtered air charge used to determine whether the slow or fast manifold filter constant is to be used." 020020 Units ="" 020050 SizeInBits =0x10 020100 Address =0x93AE 020150 Flags =0x2 020200 Equation =X/256,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x1378 000100 Cat0ID =0x12 020005 Title ="Manifold Fast Fill Constant" 020011 DescSize =0xF0 020010 Desc ="FKARC1- Filter constant for fast manifold filling. Calculate this using the equation: Constant = (load at WOT / 100) * (engine displacement / manifold volume) / number of cylinders. A typical value for load would be 80% for a stock engine." 020020 Units ="n/a" 020050 SizeInBits =0x10 020100 Address =0x93AC 020150 Flags =0x2 020200 Equation =X/65536,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0xD75 000100 Cat0ID =0x12 020005 Title ="Manifold Slow Fill Constant" 020011 DescSize =0xFB 020010 Desc ="FKARCH - Filter constant for slow manifold filling. Calculate this using the equation: Constant = (load at part throttle / 100) * (engine displacement / manifold volume) / number of cylinders. A typical value for load would be 60% for a stock engine." 020020 Units ="n/a" 020050 SizeInBits =0x10 020100 Address =0x93AA 020150 Flags =0x2 020200 Equation =X/65536,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x617E 000100 Cat0ID =0x9 020005 Title ="Manual Gearbox Max Decelleration Load for VSS Test" 020011 DescSize =0x7 020010 Desc ="VSLOAD" 020020 Units ="load" 020050 SizeInBits =0x10 020100 Address =0x8F6E 020150 Flags =0x2 020200 Equation =X/327.68,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x6034 000100 Cat0ID =0x6 020005 Title ="Max RPM for Idle Flag" 020011 DescSize =0xFE 020010 Desc ="IDLRPM - The maximum rpm permissible in order for the Idle Flag to be set when the CT flag is set. If the base target idle speed 'Idle Speed Neutral' (aka NUBASE) and 'Idle Speed Drive' (aka DRBASE) parameters have been altered then adjust this to suit." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x9AB6 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x56A1 000100 Cat0ID =0x6 020005 Title ="Max RPM for Idle Flag Hysteresis" 020011 DescSize =0x4C 020010 Desc ="IDRPMH - Hysteresis for the 'Max RPM for Idle Flag' (aka IDLRPM) parameter." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x9AB8 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0xD15 000100 Cat0ID =0x9 020005 Title ="Max Time in Hold Test" 020011 DescSize =0x6 020010 Desc ="VIPT3" 020020 Units ="secs" 020100 Address =0x8FC2 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x2B6A 000100 Cat0ID =0x9 020005 Title ="Max TP Gain for VSC Test" 020011 DescSize =0x9 020010 Desc ="VTPLU - " 020020 Units ="counts" 020050 SizeInBits =0x10 020100 Address =0x8FC8 020150 Flags =0x2 020200 Equation =X/64,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x7CCB 000100 Cat0ID =0xF 020005 Title ="MFA Cold Start Delay #1" 020011 DescSize =0x7 020010 Desc ="MFATM1" 020020 Units ="secs" 020100 Address =0x8FDB 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x6EB8 000100 Cat0ID =0xF 020005 Title ="MFA Cold Start Delay #2" 020011 DescSize =0x7 020010 Desc ="MFATM4" 020020 Units ="secs" 020100 Address =0x8FDC 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x46F7 000100 Cat0ID =0xF 020005 Title ="MFA Hot Start Delay" 020011 DescSize =0x7 020010 Desc ="MFATM3" 020020 Units ="secs" 020100 Address =0x8FD8 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x7382 000100 Cat0ID =0xF 020005 Title ="MFA Min BP for Economy Mode" 020011 DescSize =0x7 020010 Desc ="MPMNBP" 020020 Units ="in Hg" 020100 Address =0x8FF6 020200 Equation =X/8,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x3B34 000100 Cat0ID =0xF 020005 Title ="MFA Min BP for Economy Mode Hysteresis" 020011 DescSize =0x7 020010 Desc ="MPNBPH" 020020 Units ="in Hg" 020100 Address =0x8FF7 020200 Equation =X/8,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x5345 000100 Cat0ID =0xF 020005 Title ="MFA MPH Min" 020011 DescSize =0x2D 020010 Desc ="VSMPG - Minimum speed to remain in MFA mode." 020020 Units ="mph" 020100 Address =0x8E9C 020200 Equation =X/2,TH|0|0|0|0| 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x5346 000100 Cat0ID =0xF 020005 Title ="MFA MPH Hysteresis" 020011 DescSize =0x7 020010 Desc ="VSMPGH" 020020 Units ="mph" 020100 Address =0x8E9D 020200 Equation =X/2,TH|0|0|0|0| 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x685C 000100 Cat0ID =0xF 020005 Title ="MFA Ramp Increment" 020011 DescSize =0x7 020010 Desc ="MFARMP" 020020 Units ="n/a" 020100 Address =0x8FF8 020200 Equation =X/128,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x1F9 000100 Cat0ID =0xF 020005 Title ="MFA State Constant RPM Entry Condition" 020011 DescSize =0x6 020010 Desc ="MFASN" 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x8FE8 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x5964 000100 Cat0ID =0xF 020005 Title ="MFA State EGO Switch Requirement" 020011 DescSize =0x55 020010 Desc ="SWTCNT - The minimum number of HEGO switches required for the MFA timer to count up." 020020 Units ="no." 020100 Address =0x8FEC 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x198B 000100 Cat0ID =0xF 020005 Title ="MFA State Max Load Condition" 020011 DescSize =0x6 020010 Desc ="MFALH" 020020 Units ="load" 020050 SizeInBits =0x10 020100 Address =0x8FEA 020150 Flags =0x2 020200 Equation =X/327.68,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x69AD 000100 Cat0ID =0xF 020005 Title ="MFA State Max Load Condition Hysteresis" 020011 DescSize =0x7 020010 Desc ="MFALHH" 020020 Units ="load" 020050 SizeInBits =0x10 020100 Address =0x8FF4 020150 Flags =0x2 020200 Equation =X/327.68,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x8FE 000100 Cat0ID =0xF 020005 Title ="MFA State Max RPM" 020011 DescSize =0x7 020010 Desc ="MFANHI" 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x8FE6 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x2FDE 000100 Cat0ID =0xF 020005 Title ="MFA State Max RPM Hysteresis" 020011 DescSize =0x7 020010 Desc ="MFANHH" 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x8FEE 020150 Flags =0x2 020200 Equation =X,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x4537 000100 Cat0ID =0xF 020005 Title ="MFA State Min Load" 020011 DescSize =0x6 020010 Desc ="MFALL" 020020 Units ="load" 020050 SizeInBits =0x10 020100 Address =0x8FF2 020150 Flags =0x2 020200 Equation =X/327.68,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x54AB 000100 Cat0ID =0xF 020005 Title ="MFA State Min RPM" 020011 DescSize =0x7 020010 Desc ="MFANLO" 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x8FE4 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x54DE 000100 Cat0ID =0xF 020005 Title ="MFA State Min RPM Hysteresis" 020011 DescSize =0x7 020010 Desc ="MFANLH" 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x8FF0 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x248D 000100 Cat0ID =0xF 020005 Title ="MFA Warm Start Delay #1" 020011 DescSize =0x7 020010 Desc ="MFATM2" 020020 Units ="secs" 020100 Address =0x8FD9 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x359B 000100 Cat0ID =0xF 020005 Title ="MFA Warm Start Delay #2" 020011 DescSize =0x7 020010 Desc ="MFATM5" 020020 Units ="secs" 020100 Address =0x8FDA 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x360F 000100 Cat0ID =0xB 020005 Title ="MIL Delay Time" 020011 DescSize =0x5C 020010 Desc ="FMDTM - Malfunction indicator light delay time before turning on after a fault is detected." 020020 Units ="secs" 020100 Address =0x8F72 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x3A1C 000100 Cat0ID =0xB 020005 Title ="MIL Frequency" 020011 DescSize =0x62 020010 Desc ="MILTM1 - The malfunction indicator light will flash at the frequency defined by 1 / (2 * MILTM1)." 020020 Units ="secs" 020050 SizeInBits =0x10 020100 Address =0x8F76 020150 Flags =0x2 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5158 000100 Cat0ID =0x4 020005 Title ="Min PIP Period RPM (4 cyl)" 020011 DescSize =0xB4 020010 Desc ="MNPIP4 - RPM at which the ecu determines the PIP signal to be unreliable. PIP inputs are ignored above this value. Set slightly higher than 'Rev Limit Set RPM' (aka NLM_SH) limit." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x8C12 020150 Flags =0x2 020200 Equation =12500000/X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x1DAE 000100 Cat0ID =0x4 020005 Title ="Min PIP Period RPM (6 cyl)" 020011 DescSize =0xB4 020010 Desc ="MNPIP6 - RPM at which the ecu determines the PIP signal to be unreliable. PIP inputs are ignored above this value. Set slightly higher than 'Rev Limit Set RPM' (aka NLM_SH) limit." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x8C14 020150 Flags =0x2 020200 Equation =9375000/X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x52A8 000100 Cat0ID =0x4 020005 Title ="Min PIP Period RPM (8 cyl)" 020011 DescSize =0xB4 020010 Desc ="MNPIP8 - RPM at which the ecu determines the PIP signal to be unreliable. PIP inputs are ignored above this value. Set slightly higher than 'Rev Limit Set RPM' (aka NLM_SH) limit." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x8C16 020150 Flags =0x2 020200 Equation =6250000/X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x2346 000100 Cat0ID =0x1 020005 Title ="Min Time for Lugging O/L" 020011 DescSize =0x64 020010 Desc ="LDLTM - The minimum time in lugging mode required for the 'Lugging O/L Flag' (aka LDFLG) to be set." 020020 Units ="secs" 020100 Address =0x97B5 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x683A 000100 Cat0ID =0x1 020005 Title ="Min Time for Lugging O/L After Startup" 020011 DescSize =0x8E 020010 Desc ="LDTM - The minimum time after startup in lugging mode required for the Lugging O/L Flag to be set.\r\n\r\nDoes not appear to be used in this ecu." 020020 Units ="secs" 020100 Address =0x97B4 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x1502 000100 Cat0ID =0x9 020005 Title ="Min TP Gain for VSC Test" 020011 DescSize =0x9 020010 Desc ="VTPLD - " 020020 Units ="counts" 020050 SizeInBits =0x10 020100 Address =0x8FC6 020150 Flags =0x2 020200 Equation =X/64,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x7566 000100 Cat0ID =0x3 020005 Title ="MPH Average Time Constant" 020011 DescSize =0xDD 020010 Desc ="TCVS - The time constant for the rolling average calculation of the 'MPH Average' (aka VSBAR) value.\r\n\r\nLarger time constant values increase the time lag of the value being updated but reduce unwanted transients from it." 020020 Units ="secs" 020050 SizeInBits =0x10 020100 Address =0x97FA 020150 Flags =0x2 020200 Equation =X/1024,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x457A 000100 Cat0ID =0x3 020005 Title ="MPH Time Constant" 020011 DescSize =0xD4 020010 Desc ="TCMPH - The time constant for the rolling average calculation of the 'MPH' (aka MPH) value.\r\n\r\nLarger time constant values increase the time lag of the value being updated but reduce unwanted transients from it." 020020 Units ="secs" 020050 SizeInBits =0x10 020100 Address =0x9802 020150 Flags =0x2 020200 Equation =X/1024,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x59EF 000100 Cat0ID =0xB 020005 Title ="Neutral Drive Switch Min" 020011 DescSize =0x5 020010 Desc ="VND1" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8F78 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x4DE9 000100 Cat0ID =0xB 020005 Title ="Neutral Drive Switch Max" 020011 DescSize =0x5 020010 Desc ="VND2" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8F7A 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%TABLE%% 000002 UniqueID =0x6149 000100 Cat0ID =0x1 040005 Title ="Accel Enrichment Fuel" 040011 DescSize =0x7 040010 Desc ="FN1303" 040100 Address =0x91CB 040200 ZEq =X/4,TH|0|0|0|0| 040203 XOutType =0x4 040304 YOutType =0x4 040230 RangeLow =0.0000 040240 RangeHigh =100.0000 040300 Rows =0x7 040305 Cols =0x8 040320 XUnits ="deg/sec rate" 040325 YUnits ="deg F" 040330 ZUnits ="lb/min" 040350 XLabels = 17, 32, 47, 62, 77, 92,107,122 040352 XLabelType =0x4 040354 XEq =X,TH|0|0|0|0| 040360 YLabels =-50, 0, 50,100,150,200,250 040362 YLabelType =0x4 040364 YEq =X,TH|0|0|0|0| 040500 XLabelLink =0x3CD7 040505 XLabelSource =0x2 040510 YLabelLink =0x18ED 040515 YLabelSource =0x2 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x18ED 000100 Cat0ID =0x8 000101 Cat1ID =0xFF 040005 Title ="Accel Enrichment Fuel Scaler for ACT to ECT" 040011 DescSize =0x82 040010 Desc ="FN020B - Do not edit first or last entries. Provides row scaling for the following table;\r\n\r\n'Accel Enrichment Fuel' (aka FN1303)" 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x40 040200 ZEq =X,TH|0|0|0|0| 040203 XOutType =0x2 040304 YOutType =0x2 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x5 040305 Cols =0x1 040320 XUnits ="deg F" 040325 YUnits ="row" 040330 ZUnits ="" 040350 XLabels =Table Row Index 040352 XLabelType =0x4 040354 XEq =X*2,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/16,TH|0|0|0|0| 040600 XAddress =0x8CA8 040610 XDataSize =0x1 040620 XAddrStep =-2 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x8CA9 040710 YDataSize =0x1 040720 YAddrStep =-2 040750 YOutputDig =0x1 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%FLAG%% 000002 UniqueID =0x3022 000100 Cat0ID =0xA 030005 Title ="Adaptive Control Idle Low RPM" 030011 DescSize =0xF6 030010 Desc ="HCAMSW - Clear for the adaptive idle fuel cells to used as soon as the filtered airmass region is entered. Set for the adaptive idle fuel cells to used only when in the filtered airmass region and there are no base idle rpm adders being applied." 030100 Address =0x9AFA 030200 BitNumber =0x0 %%END%% %%FLAG%% 000002 UniqueID =0x5E83 000100 Cat0ID =0xE 030005 Title ="Adjustable Dampers Present" 030011 DescSize =0x31 030010 Desc ="HPACL - Set if adjustable dampers are present.\r\n" 030100 Address =0x940E 030200 BitNumber =0x0 %%END%% %%FLAG%% 000002 UniqueID =0x2410 000100 Cat0ID =0x7 030005 Title ="Air Charge Switch" 030011 DescSize =0x93 030010 Desc ="ARCHSW - Selects the method of calculating the filtered air charge value. Set to use manifold filling compensation otherwise no filtering is used." 030100 Address =0x93B0 030200 BitNumber =0x0 %%END%% %%TABLE%% 000002 UniqueID =0x3CD7 000100 Cat0ID =0x8 000101 Cat1ID =0xFF 040005 Title ="Accel Enrichment Fuel Scaler for Throttle Rate" 040011 DescSize =0x85 040010 Desc ="FN019B - Do not edit first or last entries. Provides column scaling for the following table;\r\n\r\n'Accel Enrichment Fuel' (aka FN1303)" 040020 SubType =0x7 040100 Address =0x0 040200 ZEq =X,TH|0|0|0|0| 040304 YOutType =0x2 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x5 040305 Cols =0x1 040320 XUnits ="deg/sec" 040325 YUnits ="column" 040330 ZUnits ="" 040350 XLabels =Table Column Index 040352 XLabelType =0x4 040354 XEq =X/2,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/16,TH|0|0|0|0| 040600 XAddress =0x8C9E 040610 XDataSize =0x1 040620 XAddrStep =-2 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x8C9F 040710 YDataSize =0x1 040720 YAddrStep =-2 040750 YOutputDig =0x1 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0xFF3 000100 Cat0ID =0x1 000101 Cat1ID =0xFF 040005 Title ="Accel Enrichment Multiplier for BP" 040011 DescSize =0xFB 040010 Desc ="FN378 - A multiplier of the result of the 'Accel Enrichment Fuel' table lookup after the 'Accel Enrichment Multiplier for TP' (aka FN331B) multiplier has been applied.\r\n\r\nMultiplier values less than 1 reduce fuel, values greater than 1 increase fuel." 040020 SubType =0x7 040100 Address =0x0 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x5 040305 Cols =0x1 040320 XUnits ="in Hg" 040325 YUnits ="multiplier" 040330 ZUnits ="" 040350 XLabels =Barometric Pressure 040352 XLabelType =0x4 040354 XEq =X/8,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/128,TH|0|0|0|0| 040600 XAddress =0x8DA6 040610 XDataSize =0x1 040620 XAddrStep =-2 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x8DA7 040710 YDataSize =0x1 040720 YAddrStep =-2 040750 YOutputDig =0x3 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x5016 000100 Cat0ID =0x1 000101 Cat1ID =0xFF 040005 Title ="Accel Enrichment Multiplier for TP" 040011 DescSize =0xC6 040010 Desc ="FN331B - A multiplier of the result of the 'Accel Enrichment Fuel' table lookup for the relative throttle position.\r\nMultiplier values less than 1 reduce fuel, values greater than 1 increase fuel." 040020 SubType =0x7 040100 Address =0x0 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x5 040305 Cols =0x1 040320 XUnits ="volts" 040325 YUnits ="multiplier" 040330 ZUnits ="" 040350 XLabels =Throttle Position,Accelerator Enrichment Multiplier 040352 XLabelType =0x4 040354 XEq =X/12800*256,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/128,TH|0|0|0|0| 040600 XAddress =0x91C1 040610 XDataSize =0x1 040620 XAddrStep =-2 040650 XOutputDig =0x3 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x91C2 040710 YDataSize =0x1 040720 YAddrStep =-2 040750 YOutputDig =0x3 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x5879 000100 Cat0ID =0xA 040005 Title ="Adaptive Control Learning Table" 040011 DescSize =0x33B 040010 Desc ="FN1325 - Specifies the number of background loop counts that must occur before an adaptive update can happen. Any positive values shown are actually half that of the number of loop counts required. Positive values or zero permit adaptive update to occur in the cell, higher values reduce the update rate. Negative values force the ecu to use a different cell, e.g. -24 indicates that the cell located at row 2, column 4 should be used. Note: rows and columns commence their numbering at zero.\r\n\r\nThe top row is for used for the special idle adaptive cells (the first four entries only as the others are ignored) and are assigned as follows;\r\n\r\nColumn 0 - in drive, A/C off (automatic transmissions only)\r\nColumn 1 - in drive, A/C on (automatic transmissions only)\r\nColumn 2 - in neutral, A/C off\r\nColumn 3 - in neutral, A/C on" 040100 Address =0x9E00 040150 Flags =0x1 040200 ZEq =X,TH|0|0|0|0| 040203 XOutType =0x4 040304 YOutType =0x4 040205 OutType =0x2 040230 RangeLow =0.0000 040240 RangeHigh =250.0000 040300 Rows =0x9 040305 Cols =0xA 040320 XUnits ="rpm" 040325 YUnits ="load" 040330 ZUnits ="" 040350 XLabels =(null),(null),(null),(null),(null),(null),(null),(null),(null),(null) 040352 XLabelType =0x4 040354 XEq =X,TH|0|0|0|0| 040360 YLabels =(null),(null),(null),(null),(null),(null),(null),(null),(null) 040362 YLabelType =0x4 040364 YEq =X,TH|0|0|0|0| 040500 XLabelLink =0x7CE5 040505 XLabelSource =0x2 040510 YLabelLink =0x5130 040515 YLabelSource =0x2 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x5130 000100 Cat0ID =0x8 000101 Cat1ID =0xFF 040005 Title ="Adaptive & MAF Backflow Scaler for Load" 040011 DescSize =0xA7 040010 Desc ="FN021 - Do not edit first or last entries. Provides row scaling for the following tables;\r\n\r\n'Adaptive Control Learning Table' (aka FN1325)\r\n'MAF Backflow Correction'" 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x300 040200 ZEq =X,TH|0|0|0|0| 040304 YOutType =0x2 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x8 040305 Cols =0x1 040320 XUnits ="load" 040325 YUnits ="row" 040330 ZUnits ="" 040350 XLabels =Raw Load,Table Row (Y) Index 040352 XLabelType =0x4 040354 XEq =X/327.68,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/256,TH|0|0|0|0| 040600 XAddress =0x8CB2 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x8CB4 040750 YOutputDig =0x1 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x6C08 000100 Cat0ID =0x4 000101 Cat1ID =0xFF 040005 Title ="Air Charge Maximum" 040011 DescSize =0x1C7 040010 Desc ="FN037 - The maximum instantaneous air charge value the engine can hold for a given rpm. The calculated instantaneous air charge value is clipped to this. Typically the output column values are set to the maximum on boosted engines and those that have very high volumetric efficiencies.\r\n\r\nTo calculate how this clip relates to airmass flow for differing rpms use the following calculation;\r\n\r\nkg/hr = FN037 * number of cylinders / 2 * rpm * 60 / 2.20462 " 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x300 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0xA 040305 Cols =0x1 040320 XUnits ="rpm" 040325 YUnits ="lb/intake" 040330 ZUnits ="" 040350 XLabels = 040352 XLabelType =0x4 040354 XEq =X/4,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/16777216,TH|0|0|0|0| 040600 XAddress =0x9204 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x9206 040750 YOutputDig =0x7 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0xF2F 000100 Cat0ID =0x2 000101 Cat1ID =0x1 040005 Title ="Altitude Multiplier vs BP" 040011 DescSize =0xD9 040010 Desc ="FN129A - Used in altitude spark and lugging open loop fuel calculations. Should be set to 1.000 at high altitudes and 0.000 at sea level. Values must overlap with the 'Sea Level Multiplier vs BP' (aka FN212A) table. " 040020 SubType =0x7 040100 Address =0x0 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x6 040305 Cols =0x1 040320 XUnits ="in Hg" 040325 YUnits ="multiplier" 040330 ZUnits ="" 040350 XLabels =Barometric Pressure 040352 XLabelType =0x4 040354 XEq =X/8,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/128,TH|0|0|0|0| 040600 XAddress =0x94F8 040610 XDataSize =0x1 040620 XAddrStep =-2 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x94F9 040710 YDataSize =0x1 040720 YAddrStep =-2 040750 YOutputDig =0x3 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x51B 000100 Cat0ID =0x3 000101 Cat1ID =0xFF 040005 Title ="BAP Transfer" 040011 DescSize =0x6 040010 Desc ="FN000" 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x300 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x6 040305 Cols =0x1 040320 XUnits ="volts" 040325 YUnits ="in Hg" 040330 ZUnits ="" 040350 XLabels =X,Y 040352 XLabelType =0x4 040354 XEq =X/12800,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/2048,TH|0|0|0|0| 040600 XAddress =0x8C78 040650 XOutputDig =0x3 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x8C7A 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x2481 000100 Cat0ID =0xD 000101 Cat1ID =0xFF 040005 Title ="Canister Purge Dutycycle Multiplier #1" 040011 DescSize =0x6 040010 Desc ="FN600" 040020 SubType =0x7 040100 Address =0x0 040200 ZEq =X,TH|0|0|0|0| 040203 XOutType =0x2 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x6 040305 Cols =0x1 040320 XUnits ="secs" 040325 YUnits ="multiplier" 040330 ZUnits ="" 040350 XLabels = 040352 XLabelType =0x4 040354 XEq =X,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/128,TH|0|0|0|0| 040600 XAddress =0x9A5A 040610 XDataSize =0x1 040620 XAddrStep =-2 040650 XOutputDig =0x1 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x9A5B 040710 YDataSize =0x1 040720 YAddrStep =-2 040750 YOutputDig =0x3 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x595B 000100 Cat0ID =0xD 000101 Cat1ID =0xFF 040005 Title ="Canister Purge Dutycycle Multiplier #2" 040011 DescSize =0x6 040010 Desc ="FN602" 040020 SubType =0x7 040100 Address =0x0 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x6 040305 Cols =0x1 040320 XUnits ="secs" 040325 YUnits ="multiplier" 040330 ZUnits ="" 040350 XLabels = 040352 XLabelType =0x4 040354 XEq =X/8,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/128,TH|0|0|0|0| 040600 XAddress =0x9A66 040610 XDataSize =0x1 040620 XAddrStep =-2 040650 XOutputDig =0x3 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x9A67 040710 YDataSize =0x1 040720 YAddrStep =-2 040750 YOutputDig =0x3 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x1DD1 000100 Cat0ID =0xD 000101 Cat1ID =0xFF 040005 Title ="Canister Purge Dutycycle vs Airmass" 040011 DescSize =0xA 040010 Desc ="FN605A - " 040020 SubType =0x7 040100 Address =0x0 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x6 040305 Cols =0x1 040320 XUnits ="lb" 040325 YUnits ="dutycycle" 040330 ZUnits ="" 040350 XLabels = 040352 XLabelType =0x4 040354 XEq =X/8,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/1.28,TH|0|0|0|0| 040600 XAddress =0x9A72 040610 XDataSize =0x1 040620 XAddrStep =-2 040650 XOutputDig =0x3 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x9A73 040710 YDataSize =0x1 040720 YAddrStep =-2 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0xEF8 000100 Cat0ID =0x1 000101 Cat1ID =0xFF 040005 Title ="Cold Engine Fuel Multiplier Update Time" 040011 DescSize =0x166 040010 Desc ="FN393F - When the 'Cold Engine Fuel Multiplier Update Timer' (aka MULTMR) exceeds this parameter's lookup value then the 'Cold Engine Fuel Multiplier' (aka LAMMUL) value is updated.\r\n\r\nThe 'Cold Engine Fuel Multiplier' (aka LAMMUL) value is used to prevent stalling during drive engagement when the engine is cold (automatic gearbox equipped vehicles only)." 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x40 040200 ZEq =X,TH|0|0|0|0| 040203 XOutType =0x2 040304 YOutType =0x2 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x7 040305 Cols =0x1 040320 XUnits ="deg F" 040325 YUnits ="secs" 040330 ZUnits ="" 040350 XLabels =ECT 040352 XLabelType =0x4 040354 XEq =X*2,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X,TH|0|0|0|0| 040600 XAddress =0x8C18 040610 XDataSize =0x1 040620 XAddrStep =-2 040650 XOutputDig =0x1 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x8C19 040710 YDataSize =0x1 040720 YAddrStep =-2 040750 YOutputDig =0x1 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x793A 000100 Cat0ID =0x1 000101 Cat1ID =0xFF 040005 Title ="Cranking Fuel PW Multiply vs Time" 040011 DescSize =0x52 040010 Desc ="FN306 - Multiplies cranking fuel pulsewidth according to length of cranking time." 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x300 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x6 040305 Cols =0x1 040320 XUnits ="sec" 040325 YUnits ="multiplier" 040330 ZUnits ="" 040350 XLabels = 040352 XLabelType =0x4 040354 XEq =X/8,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/16384,TH|0|0|0|0| 040600 XAddress =0x9862 040650 XOutputDig =0x3 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x9864 040750 YOutputDig =0x3 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x4084 000100 Cat0ID =0x1 000101 Cat1ID =0xFF 040005 Title ="Cranking Fuel PW vs ECT" 040011 DescSize =0xBA 040010 Desc ="FN348 - The injector pulsewidth during cranking at sea level. Alter for injector and cam swaps. For larger injectors reduce the pulsewidth by the ratio of the low injector slope change." 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x340 040200 ZEq =X,TH|0|0|0|0| 040203 XOutType =0x2 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x9 040305 Cols =0x1 040320 XUnits ="deg F" 040325 YUnits ="mSecs" 040330 ZUnits ="" 040350 XLabels =Engine Coolant Temperature,Pulsewidth 040352 XLabelType =0x4 040354 XEq =X*2,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/262.144,TH|0|0|0|0| 040600 XAddress =0x987A 040650 XOutputDig =0x1 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x987C 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x44A7 000100 Cat0ID =0x1 000101 Cat1ID =0xFF 040005 Title ="CT Drive Fuel Multiplier vs RPM" 040011 DescSize =0xEF 040010 Desc ="FN301 - Open loop mode multiplier that adjusts the desired A/F ratio when the throttle is closed, the gearbox is in drive and no HEGO switches have occurred.\r\nMultiplier values less than 1 increase fuel, values greater than 1 reduce fuel." 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x300 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x6 040305 Cols =0x1 040320 XUnits ="rpm" 040325 YUnits ="multiplier" 040330 ZUnits ="" 040350 XLabels = 040352 XLabelType =0x4 040354 XEq =X/4,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/128,TH|0|0|0|0| 040600 XAddress =0x9B54 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x9B56 040750 YOutputDig =0x3 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x551E 000100 Cat0ID =0x1 000101 Cat1ID =0xFF 040005 Title ="CT Neutral Fuel Multiplier vs RPM" 040011 DescSize =0xD2 040010 Desc ="FN301N - Open loop mode multiplier that adjusts the desired A/F ratio when the throttle is closed and the gearbox is in neutral.\r\nMultiplier values less than 1 increase fuel, values greater than 1 reduce fuel." 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x300 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x5 040305 Cols =0x1 040320 XUnits ="rpm" 040325 YUnits ="multiplier" 040330 ZUnits ="" 040350 XLabels = 040352 XLabelType =0x4 040354 XEq =X/4,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/128,TH|0|0|0|0| 040600 XAddress =0x9B6C 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x9B6E 040750 YOutputDig =0x3 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x1A00 000100 Cat0ID =0x6 000101 Cat1ID =0xFF 040005 Title ="CT Neutral Timer RPM Adder" 040011 DescSize =0x10C 040010 Desc ="FN880 - The results of this table are used in two ways:\r\n\r\ni) The result of this lookup is used to increase desired idle rpm when the 'CT Neutral Flag (aka CTNFLG) is set.\r\n\r\nii) The result of this lookup is added to the 'CT Neutral Timer Max RPM' (aka INLRPM) value." 040020 SubType =0x7 040100 Address =0x0 040200 ZEq =X,TH|0|0|0|0| 040203 XOutType =0x2 040304 YOutType =0x2 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x7 040305 Cols =0x1 040320 XUnits ="secs" 040325 YUnits ="rpm" 040330 ZUnits ="" 040350 XLabels = 040352 XLabelType =0x4 040354 XEq =X,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X*8,TH|0|0|0|0| 040600 XAddress =0x955A 040610 XDataSize =0x1 040620 XAddrStep =-2 040650 XOutputDig =0x1 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x955B 040710 YDataSize =0x1 040720 YAddrStep =-2 040750 YOutputDig =0x1 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x5880 000100 Cat0ID =0x2 000101 Cat1ID =0xFF 040005 Title ="CT Spark Adder for ECT" 040011 DescSize =0x31 040010 Desc ="FN112 - Added to 'CT Spark vs RPM' lookup value." 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0xC0 040200 ZEq =X,TH|0|0|0|0| 040203 XOutType =0x2 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x7 040305 Cols =0x1 040320 XUnits ="deg F" 040325 YUnits ="deg adv" 040330 ZUnits ="" 040350 XLabels =ECT 040352 XLabelType =0x4 040354 XEq =X*2,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/4,TH|0|0|0|0| 040600 XAddress =0x94C0 040610 XDataSize =0x1 040620 XAddrStep =-2 040650 XOutputDig =0x1 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x94C1 040710 YDataSize =0x1 040720 YAddrStep =-2 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x40BC 000100 Cat0ID =0x2 000101 Cat1ID =0xFF 040005 Title ="CT Spark Subtractor for BP" 040011 DescSize =0x6E 040010 Desc ="FN115 - Subtracted from 'CT Spark vs RPM' lookup value at startup to heat up the catalytic convertor quicker." 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x80 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x6 040305 Cols =0x1 040320 XUnits ="in Hg" 040325 YUnits ="deg adv" 040330 ZUnits ="" 040350 XLabels =Barometric Pressure 040352 XLabelType =0x4 040354 XEq =X/8,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/4,TH|0|0|0|0| 040600 XAddress =0x94CE 040610 XDataSize =0x1 040620 XAddrStep =-2 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x94CF 040710 YDataSize =0x1 040720 YAddrStep =-2 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x7435 000100 Cat0ID =0x2 000101 Cat1ID =0xFF 040005 Title ="CT Spark Subtractor for Neutral" 040011 DescSize =0xE1 040010 Desc ="FN180 - When the 'CT Neutral Flag' (aka CTNFLG) is set the result of this table lookup is subtracted from the 'CT Spark vs RPM' lookup value. The input value to this table is the 'Closed Throttle Neutral Timer' (aka CTNTMR)." 040020 SubType =0x7 040100 Address =0x0 040200 ZEq =X,TH|0|0|0|0| 040203 XOutType =0x2 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x6 040305 Cols =0x1 040320 XUnits ="secs" 040325 YUnits ="deg adv" 040330 ZUnits ="" 040350 XLabels = 040352 XLabelType =0x4 040354 XEq =X,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/4,TH|0|0|0|0| 040600 XAddress =0x954E 040610 XDataSize =0x1 040620 XAddrStep =-2 040650 XOutputDig =0x1 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x954F 040710 YDataSize =0x1 040720 YAddrStep =-2 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x41FC 000100 Cat0ID =0x2 000101 Cat1ID =0xFF 040005 Title ="CT Spark vs RPM" 040011 DescSize =0x3F 040010 Desc ="FN111 - The base spark value used when the throttle is closed." 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x3C0 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x5 040305 Cols =0x1 040320 XUnits ="rpm" 040325 YUnits ="deg adv" 040330 ZUnits ="" 040350 XLabels =Speed 040352 XLabelType =0x4 040354 XEq =X/4,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/4,TH|0|0|0|0| 040600 XAddress =0x94AC 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x94AE 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x4D78 000100 Cat0ID =0x6 000101 Cat1ID =0xFF 040005 Title ="Dashpot Decrement Rate" 040011 DescSize =0x133 040010 Desc ="FN879 - Determines the dashpot (pre position airflow) bleed off rate according to the current dashpot value. During closed throttle mode the dashpot airflow is bled off by decrementing it in order to smooth the transition into rpm control by slowly eliminating the dashpot contribution to the idle airflow." 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x300 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x7 040305 Cols =0x1 040320 XUnits ="lb/min" 040325 YUnits ="lb/min" 040330 ZUnits ="" 040350 XLabels =Dashpot,Decrement Rate 040352 XLabelType =0x4 040354 XEq =X/4096,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/4096,TH|0|0|0|0| 040600 XAddress =0x932A 040650 XOutputDig =0x6 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x932C 040750 YOutputDig =0x6 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x4066 000100 Cat0ID =0x6 000101 Cat1ID =0xFF 040005 Title ="Dashpot Max Clip" 040011 DescSize =0x4C 040010 Desc ="FN882 - The maximum dashpot (pre position airflow) allowed for a given rpm." 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x300 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x5 040305 Cols =0x1 040320 XUnits ="rpm" 040325 YUnits ="lb/min" 040330 ZUnits ="" 040350 XLabels =RPM,Dashpot Clip 040352 XLabelType =0x4 040354 XEq =X/4,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/4096,TH|0|0|0|0| 040600 XAddress =0x9346 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x9348 040750 YOutputDig =0x6 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x1450 000100 Cat0ID =0x1 000101 Cat1ID =0xFF 040005 Title ="Decel Fuel Shut Off Multiplier" 040011 DescSize =0x143 040010 Desc ="FN374 - Adjusts the desired fuel flow if the conditions required for deceleration fuel shut off have been met.\r\nSet multiplier to 0 to invoke deceleration fuel shut off at desired rpm otherwise set to 1.\r\nWhen in underspeed mode this multiplier value is multiplied by the result of the 'Underspeed Fuel Multiplier' lookup." 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x300 040200 ZEq =X,TH|0|0|0|0| 040304 YOutType =0x2 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x6 040305 Cols =0x1 040320 XUnits ="rpm" 040325 YUnits ="multiplier" 040330 ZUnits ="" 040350 XLabels =RPM,Open Loop Fuel Multiplier 040352 XLabelType =0x4 040354 XEq =X/4,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/128,TH|0|0|0|0| 040600 XAddress =0x9DE8 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x9DEA 040750 YOutputDig =0x1 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0xD23 000100 Cat0ID =0x1 000101 Cat1ID =0xFF 040005 Title ="Drive Engagement Fuel Multiplier vs ECT" 040011 DescSize =0x12D 040010 Desc ="FN371 - Provides an initial value for the 'Cold Engine Fuel Multiplier' (aka LAMMUL) value which is used to prevent stalling during drive engagement when the engine is cold (automatic gearbox equipped vehicles only). \r\n\r\nMultiplier values less than 1 increase fuel, values greater than 1 reduce fuel." 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x340 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x8 040305 Cols =0x1 040320 XUnits ="deg F" 040325 YUnits ="multiplier" 040330 ZUnits ="" 040350 XLabels =ECT 040352 XLabelType =0x4 040354 XEq =X/128,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/256,TH|0|0|0|0| 040600 XAddress =0x9CC8 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x9CCA 040750 YOutputDig =0x3 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x648C 000100 Cat0ID =0x2 000101 Cat1ID =0xFF 040005 Title ="Dwell Time Low Temperature" 040011 DescSize =0xAB 040010 Desc ="FN160A - Used when the estimated coil temperature is less than or equal to the 'Dwell Time Table Select Temperature' (aka DWLTBP) value.\r\n\r\nY conversion might be X/524288" 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x300 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x6 040305 Cols =0x1 040320 XUnits ="volts" 040325 YUnits ="mSecs" 040330 ZUnits ="" 040350 XLabels =Battery Voltage,Dwell / Coil Off Time 040352 XLabelType =0x4 040354 XEq =X/16,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/512,TH|0|0|0|0| 040600 XAddress =0x9748 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x974A 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x299 000100 Cat0ID =0x2 000101 Cat1ID =0xFF 040005 Title ="Dwell Time High Temperature" 040011 DescSize =0xA2 040010 Desc ="FN160B - Used when the estimated coil temperature is greater than the 'Dwell Time Table Select Temperature' (aka DWLTBP) value.\r\n\r\nY conversion might be X/524288" 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x300 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x6 040305 Cols =0x1 040320 XUnits ="volts" 040325 YUnits ="mSecs" 040330 ZUnits ="" 040350 XLabels =Battery Voltage,Dwell / Coil Off Time 040352 XLabelType =0x4 040354 XEq =X/16,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/512,TH|0|0|0|0| 040600 XAddress =0x9760 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x9762 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x7458 000100 Cat0ID =0x3 000101 Cat1ID =0xFF 040005 Title ="ECT ACT Transfer" 040011 DescSize =0x33 040010 Desc ="FN703A - Input is a rough hi byte only conversion." 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x80 040200 ZEq =X,TH|0|0|0|0| 040304 YOutType =0x2 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0xA 040305 Cols =0x1 040320 XUnits ="volts" 040325 YUnits ="deg F" 040330 ZUnits ="" 040350 XLabels =Sensor,Temperature 040352 XLabelType =0x4 040354 XEq =X/64,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X*2,TH|0|0|0|0| 040600 XAddress =0x8DB0 040610 XDataSize =0x1 040620 XAddrStep =-2 040650 XOutputDig =0x3 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x8DB1 040710 YDataSize =0x1 040720 YAddrStep =-2 040750 YOutputDig =0x1 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x1F4 000100 Cat0ID =0xC 000101 Cat1ID =0xFF 040005 Title ="EGR Altitude Multiplier for BP" 040011 DescSize =0x5B 040010 Desc ="FN217A - A multiplier of the result of the 'EGR Altitude Table' (aka FN908B) table lookup." 040020 SubType =0x7 040100 Address =0x0 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x6 040305 Cols =0x1 040320 XUnits ="in Hg" 040325 YUnits ="multiplier" 040330 ZUnits ="" 040350 XLabels =Barometric Pressure 040352 XLabelType =0x4 040354 XEq =X/8,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/128,TH|0|0|0|0| 040600 XAddress =0x98F8 040610 XDataSize =0x1 040620 XAddrStep =-2 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x98F9 040710 YDataSize =0x1 040720 YAddrStep =-2 040750 YOutputDig =0x3 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x7875 000100 Cat0ID =0xC 040005 Title ="EGR Altitude Table" 040011 DescSize =0x7 040010 Desc ="FN908B" 040100 Address =0x99FE 040200 ZEq =X/4,TH|0|0|0|0| 040203 XOutType =0x4 040304 YOutType =0x4 040230 RangeLow =0.0000 040240 RangeHigh =50.0000 040300 Rows =0x8 040305 Cols =0xA 040320 XUnits ="rpm" 040325 YUnits ="load" 040330 ZUnits ="EGR%" 040350 XLabels = 500, 700, 900, 1100, 1300, 1500, 2000, 2500, 3000, 4000 040352 XLabelType =0x4 040354 XEq =X,TH|0|0|0|0| 040360 YLabels =0.050,0.100,0.200,0.300,0.400,0.500,0.600,0.750 040362 YLabelType =0x4 040364 YEq =X,TH|0|0|0|0| 040500 XLabelLink =0x7CE5 040505 XLabelSource =0x2 040510 YLabelLink =0x618F 040515 YLabelSource =0x2 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x79F9 000100 Cat0ID =0xC 000101 Cat1ID =0xFF 040005 Title ="EGR Desired Drop vs Desired Flow" 040011 DescSize =0x6 040010 Desc ="FN247" 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x300 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0xA 040305 Cols =0x1 040320 XUnits ="lb/min" 040325 YUnits ="in H2O" 040330 ZUnits ="" 040350 XLabels =X,Y 040352 XLabelType =0x4 040354 XEq =X/32768,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/256,TH|0|0|0|0| 040600 XAddress =0x9986 040650 XOutputDig =0x3 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x9988 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x7864 000100 Cat0ID =0xC 000101 Cat1ID =0xFF 040005 Title ="EGR Dutycycle Adder vs EGR Error" 040011 DescSize =0x9 040010 Desc ="FN239 - " 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x3C0 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x7 040305 Cols =0x1 040320 XUnits ="volts" 040325 YUnits ="adder" 040330 ZUnits ="" 040350 XLabels = 040352 XLabelType =0x4 040354 XEq =X/6400,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/327.68,TH|0|0|0|0| 040600 XAddress =0x9942 040650 XOutputDig =0x3 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x9944 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x196A 000100 Cat0ID =0xC 000101 Cat1ID =0xFF 040005 Title ="EGR Mass Flow as a Function of DELPR" 040011 DescSize =0x24 040010 Desc ="FN246 - Also called 'EGR Transfer'." 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x300 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0xA 040305 Cols =0x1 040320 XUnits ="in H2O" 040325 YUnits ="lb/min" 040330 ZUnits ="" 040350 XLabels =X,Y 040352 XLabelType =0x4 040354 XEq =X/256,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/32768,TH|0|0|0|0| 040600 XAddress =0x995E 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x9960 040750 YOutputDig =0x3 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x3B2B 000100 Cat0ID =0xC 000101 Cat1ID =0xFF 040005 Title ="EGR Mass Flow vs EGR Valve Position" 040011 DescSize =0x43 040010 Desc ="FN219A - Used when 'EGR Type' (aka PFEHP) parameter is set to '0'." 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x300 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x6 040305 Cols =0x1 040320 XUnits ="volts" 040325 YUnits ="lb/min" 040330 ZUnits ="" 040350 XLabels =X,Y 040352 XLabelType =0x4 040354 XEq =X*0.02,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/128,TH|0|0|0|0| 040600 XAddress =0x9904 040650 XOutputDig =0x3 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x9906 040750 YOutputDig =0x3 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x72BA 000100 Cat0ID =0xC 000101 Cat1ID =0xFF 040005 Title ="EGR Multiplier for ACT" 040011 DescSize =0x6 040010 Desc ="FN220" 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x40 040200 ZEq =X,TH|0|0|0|0| 040203 XOutType =0x2 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x5 040305 Cols =0x1 040320 XUnits ="deg F" 040325 YUnits ="multiplier" 040330 ZUnits ="" 040350 XLabels =ACT 040352 XLabelType =0x4 040354 XEq =X*2,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/128,TH|0|0|0|0| 040600 XAddress =0x991C 040610 XDataSize =0x1 040620 XAddrStep =-2 040650 XOutputDig =0x1 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x991D 040710 YDataSize =0x1 040720 YAddrStep =-2 040750 YOutputDig =0x3 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x9FF 000100 Cat0ID =0xC 000101 Cat1ID =0xFF 040005 Title ="EGR Multiplier for ECT" 040011 DescSize =0x6 040010 Desc ="FN211" 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x40 040200 ZEq =X,TH|0|0|0|0| 040203 XOutType =0x2 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x6 040305 Cols =0x1 040320 XUnits ="deg F" 040325 YUnits ="multiplier" 040330 ZUnits ="" 040350 XLabels =ECT 040352 XLabelType =0x4 040354 XEq =X*2,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/128,TH|0|0|0|0| 040600 XAddress =0x98E2 040610 XDataSize =0x1 040620 XAddrStep =-2 040650 XOutputDig =0x1 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x98E3 040710 YDataSize =0x1 040720 YAddrStep =-2 040750 YOutputDig =0x3 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x2D5 000100 Cat0ID =0xC 040005 Title ="EGR Sea Level Table" 040011 DescSize =0x7 040010 Desc ="FN908A" 040100 Address =0x99AE 040200 ZEq =X/4,TH|0|0|0|0| 040203 XOutType =0x4 040304 YOutType =0x4 040230 RangeLow =0.0000 040240 RangeHigh =50.0000 040300 Rows =0x8 040305 Cols =0xA 040320 XUnits ="rpm" 040325 YUnits ="load" 040330 ZUnits ="EGR%" 040350 XLabels = 500, 700, 900, 1100, 1300, 1500, 2000, 2500, 3000, 4000 040352 XLabelType =0x4 040354 XEq =X,TH|0|0|0|0| 040360 YLabels =0.05,0.10,0.20,0.30,0.40,0.50,0.60,0.75 040362 YLabelType =0x4 040364 YEq =X,TH|0|0|0|0| 040500 XLabelLink =0x7CE5 040505 XLabelSource =0x2 040510 YLabelLink =0x618F 040515 YLabelSource =0x2 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x25B5 000100 Cat0ID =0xC 000101 Cat1ID =0xFF 040005 Title ="EGR Valve Position vs Desired Flow" 040011 DescSize =0x6 040010 Desc ="FN221" 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x300 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x7 040305 Cols =0x1 040320 XUnits ="lb/min" 040325 YUnits ="volts" 040330 ZUnits ="" 040350 XLabels =X,Y 040352 XLabelType =0x4 040354 XEq =X/128,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X*0.02,TH|0|0|0|0| 040600 XAddress =0x9926 040650 XOutputDig =0x3 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x9928 040750 YOutputDig =0x3 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x63B2 000100 Cat0ID =0xC 000101 Cat1ID =0xFF 040005 Title ="EGR Valve Upstream Pressure" 040011 DescSize =0x40 040010 Desc ="FN074 - Upstream pressure as a function of input (AM * KAMREF)." 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x300 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0xA 040305 Cols =0x1 040320 XUnits ="lb/min" 040325 YUnits ="in H2O" 040330 ZUnits ="" 040350 XLabels =X,Y 040352 XLabelType =0x4 040354 XEq =X/2048,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/128,TH|0|0|0|0| 040600 XAddress =0x98BA 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x98BC 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x5D5C 000100 Cat0ID =0x8 000101 Cat1ID =0xFF 040005 Title ="Emission Scaler for RPM" 040011 DescSize =0xB3 040010 Desc ="FN039 - Do not edit first or last entries. Provides column scaling for the following tables;\r\n\r\n'HEGO Amplitude' (aka FN1352)\r\n'HEGO Bias' (aka FN1353)\r\n'HEGO Delay' (aka FN1351)" 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x300 040200 ZEq =X,TH|0|0|0|0| 040304 YOutType =0x2 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x8 040305 Cols =0x1 040320 XUnits ="rpm" 040325 YUnits ="column" 040330 ZUnits ="" 040350 XLabels = 040352 XLabelType =0x4 040354 XEq =X/4,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/256,TH|0|0|0|0| 040600 XAddress =0x9B10 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x9B12 040750 YOutputDig =0x1 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x618F 000100 Cat0ID =0x8 000101 Cat1ID =0xFF 040005 Title ="Emissions & Spark Scaler for Load" 040011 DescSize =0x1BE 040010 Desc ="FN071 - Do not edit first or last entries. Provides row scaling for the following tables;\r\n\r\n'EGR Altitude Table'\r\n'EGR Sea Level Table'\r\n'Equilibrium Fuel Time Constant'\r\n'Equilibrium Intake Surface Fuel'\r\n'HEGO Amplitude' (aka FN1352)\r\n'HEGO Bias' (aka FN1353)\r\n'HEGO Delay' (aka FN1351)\r\n'PT Spark Adder for ECT and Load'\r\n'PT Spark Adder for EGR'\r\n'Spark Altitude Table'\r\n'Spark Base Table'\r\n'Spark Sea Level Table'\r\n'Torque Reduction Table'" 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x300 040200 ZEq =X,TH|0|0|0|0| 040304 YOutType =0x2 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x7 040305 Cols =0x1 040320 XUnits ="load" 040325 YUnits ="row" 040330 ZUnits ="" 040350 XLabels = 040352 XLabelType =0x4 040354 XEq =X/327.68,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/256,TH|0|0|0|0| 040600 XAddress =0x8CFA 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x8CFC 040750 YOutputDig =0x1 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x3661 000100 Cat0ID =0x12 040005 Title ="Equilibrium Fuel Time Constant" 040011 DescSize =0x1E8 040010 Desc ="FN1322 - Effects the amount of contribution the transient fuel makes to the injection pulsewidth where;\r\n\r\nSmaller values increases the amount resulting in richer A/F ratios during accelerations.\r\nLarger values decreases the amount resulting in leaner A/F ratios during accelerations.\r\n\r\nThe column input value is the ratio of ACT to ECT where the ACT contribution is defined by the 'ACT Fraction for Transient Fuel' (aka ALPHA) parameter. \r\n\r\nConversion might be X/32, to be determined." 040100 Address =0x9D38 040200 ZEq =X/8,TH|0|0|0|0| 040203 XOutType =0x4 040304 YOutType =0x4 040210 DecimalPl =0x3 040230 RangeLow =0.0000 040240 RangeHigh =100.0000 040300 Rows =0x8 040305 Cols =0xA 040320 XUnits ="deg F" 040325 YUnits ="Load" 040330 ZUnits ="secs" 040350 XLabels =-30, 0, 30, 60, 90,120,150,180,210,240 040352 XLabelType =0x4 040354 XEq =X,TH|0|0|0|0| 040360 YLabels =0.05,0.10,0.20,0.30,0.40,0.50,0.60,0.75 040362 YLabelType =0x4 040364 YEq =X,TH|0|0|0|0| 040500 XLabelLink =0x3CB1 040505 XLabelSource =0x2 040510 YLabelLink =0x618F 040515 YLabelSource =0x2 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x476A 000100 Cat0ID =0x12 040005 Title ="Equilibrium Intake Surface Fuel" 040011 DescSize =0xA8 040010 Desc ="FN1321 - \r\n\r\nThe column input value is the ratio of ACT to ECT where the ACT contribution is defined by the 'ACT Fraction for Transient Fuel' (aka ALPHA) parameter. \r\n" 040100 Address =0x9CE8 040200 ZEq =X/4096,TH|0|0|0|0| 040203 XOutType =0x4 040304 YOutType =0x4 040210 DecimalPl =0x4 040230 RangeLow =0.0000 040240 RangeHigh =300.0000 040300 Rows =0x8 040305 Cols =0xA 040320 XUnits ="deg F" 040325 YUnits ="load" 040330 ZUnits ="lb/min" 040350 XLabels = 4000, 3000, 2500, 2000, 1500, 1300, 1100, 900, 700, 500 040352 XLabelType =0x4 040354 XEq =X,TH|0|0|0|0| 040360 YLabels =0.050,0.100,0.200,0.300,0.400,0.500,0.600,0.750 040362 YLabelType =0x4 040364 YEq =X,TH|0|0|0|0| 040500 XLabelLink =0x3CB1 040505 XLabelSource =0x2 040510 YLabelLink =0x618F 040515 YLabelSource =0x2 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x409B 000100 Cat0ID =0xC 000101 Cat1ID =0xFF 040005 Title ="Exhaust Back Pressure Correction" 040011 DescSize =0xFA 040010 Desc ="FN004 - Used in the exhaust pressure calculation to compensate for exhaust pressure only increasing at half the rate that barometric pressure increases. You should not need change this as it is a correction derived from pressure chamber experiments." 040020 SubType =0x7 040100 Address =0x0 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x5 040305 Cols =0x1 040320 XUnits ="in Hg" 040325 YUnits ="in Hg" 040330 ZUnits ="" 040350 XLabels =Barometric Pressure 040352 XLabelType =0x4 040354 XEq =X/8,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/8,TH|0|0|0|0| 040600 XAddress =0x98B0 040610 XDataSize =0x1 040620 XAddrStep =-2 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x98B1 040710 YDataSize =0x1 040720 YAddrStep =-2 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x43D6 000100 Cat0ID =0xB 040005 Title ="Failed MAF Sensor" 040011 DescSize =0x7D 040010 Desc ="FN1358 - Substitution instantaneous air charge value at sea level used if the MAF sensor has failed and the TP sensor is ok." 040100 Address =0x9102 040200 ZEq =X/131072,TH|0|0|0|0| 040203 XOutType =0x4 040304 YOutType =0x4 040210 DecimalPl =0x8 040230 RangeLow =0.0000 040240 RangeHigh =250.0000 040300 Rows =0x7 040305 Cols =0xA 040320 XUnits ="rpm" 040325 YUnits ="volts - TP relative" 040330 ZUnits ="lb" 040350 XLabels = 500, 700, 900, 1100, 1300, 1500, 2000, 2500, 3000, 4000 040352 XLabelType =0x4 040354 XEq =X,TH|0|0|0|0| 040360 YLabels = 0,3200,6400,12800,19200,25600,32000 040362 YLabelType =0x4 040364 YEq =X,TH|0|0|0|0| 040500 XLabelLink =0x7CE5 040505 XLabelSource =0x2 040510 YLabelLink =0x29C8 040515 YLabelSource =0x2 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x4158 000100 Cat0ID =0xB 000101 Cat1ID =0xFF 040005 Title ="Failed MAF Sensor Alternative" 040011 DescSize =0x8B 040010 Desc ="FN040 - Substitution instantaneous air charge value used if both the MAF and TP sensors have failed.\r\n\r\nOutput conversion to be confirmed." 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x300 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x8 040305 Cols =0x1 040320 XUnits ="rpm" 040325 YUnits ="lb/intake" 040330 ZUnits ="" 040350 XLabels =Speed,Y 040352 XLabelType =0x4 040354 XEq =X/4,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/16777216,TH|0|0|0|0| 040600 XAddress =0x90E2 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x90E4 040750 YOutputDig =0x7 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x3987 000100 Cat0ID =0x8 000101 Cat1ID =0xFF 040005 Title ="Fuel and Spark Scaler for RPM" 040011 DescSize =0x98 040010 Desc ="FN083 - Do not edit first or last entries. Provides column scaling for the following tables;\r\n\r\n'MFA EGR Multiplier'\r\n'MFA PT Spark Adder' (aka FN1124)" 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x300 040200 ZEq =X,TH|0|0|0|0| 040304 YOutType =0x2 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x4 040305 Cols =0x1 040320 XUnits ="rpm" 040325 YUnits ="column" 040330 ZUnits ="" 040350 XLabels =Speed,Table Index 040352 XLabelType =0x4 040354 XEq =X/4,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/256,TH|0|0|0|0| 040600 XAddress =0x8D46 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x8D48 040750 YOutputDig =0x1 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x13EF 000100 Cat0ID =0x1 040005 Title ="Fuel Base Table" 040011 DescSize =0xC4 040010 Desc ="FN1307 - Used when in open loop mode.\r\n\r\nThe column input value is the ratio of ACT to ECT where the ACT contribution is defined by the 'ACT Fraction for Fuel Base Table' (aka FRCBFT) parameter. " 040100 Address =0x9BF0 040200 ZEq =X/128*14.64,TH|0|0|0|0| 040203 XOutType =0x4 040304 YOutType =0x4 040230 RangeLow =8.0000 040240 RangeHigh =18.0000 040300 Rows =0x8 040305 Cols =0xA 040320 XUnits ="deg F" 040325 YUnits ="load%" 040330 ZUnits ="A/F Ratio" 040350 XLabels =(null),(null),(null),(null),(null),(null),(null),(null),(null),(null) 040352 XLabelType =0x4 040354 XEq =X,TH|0|0|0|0| 040360 YLabels =(null),(null),(null),(null),(null),(null),(null),(null) 040362 YLabelType =0x4 040364 YEq =X,TH|0|0|0|0| 040500 XLabelLink =0x3CB1 040505 XLabelSource =0x2 040510 YLabelLink =0x6012 040515 YLabelSource =0x2 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x5567 000100 Cat0ID =0x1 000101 Cat1ID =0xFF 040005 Title ="Fuel Lugging Altitude Multiplier" 040011 DescSize =0xA4 040010 Desc ="FN309 - Open loop mode multiplier that adjusts the desired A/F ratio when lugging.\r\nMultiplier values less than 1 increase fuel, values greater than 1 reduce fuel." 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x300 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x7 040305 Cols =0x1 040320 XUnits ="rpm" 040325 YUnits ="multiplier" 040330 ZUnits ="" 040350 XLabels = 040352 XLabelType =0x4 040354 XEq =X/4,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/128,TH|0|0|0|0| 040600 XAddress =0x9846 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x9848 040750 YOutputDig =0x3 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x16B2 000100 Cat0ID =0x1 000101 Cat1ID =0xFF 040005 Title ="Fuel Lugging Sea Level Multiplier" 040011 DescSize =0xA4 040010 Desc ="FN308 - Open loop mode multiplier that adjusts the desired A/F ratio when lugging.\r\nMultiplier values less than 1 increase fuel, values greater than 1 reduce fuel." 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x300 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x7 040305 Cols =0x1 040320 XUnits ="rpm" 040325 YUnits ="multiplier" 040330 ZUnits ="" 040350 XLabels = 040352 XLabelType =0x4 040354 XEq =X/4,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/128,TH|0|0|0|0| 040600 XAddress =0x982A 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x982C 040750 YOutputDig =0x3 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x6EC3 000100 Cat0ID =0x1 000101 Cat1ID =0xFF 040005 Title ="Fuel Multiplier vs ACT" 040011 DescSize =0xD2 040010 Desc ="FN300 - Open loop multiplier applied to the result of the 'Fuel Base Table' (aka FN1307) lookup to adjust the desired A/F ratio.\r\nMultiplier values less than 1 increase fuel, values greater than 1 reduce fuel." 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x40 040200 ZEq =X,TH|0|0|0|0| 040203 XOutType =0x2 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x6 040305 Cols =0x1 040320 XUnits ="deg F" 040325 YUnits ="multiplier" 040330 ZUnits ="" 040350 XLabels =Intake Air ChargeTemp,Open Loop Fuel Multiplier 040352 XLabelType =0x4 040354 XEq =X*2,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/64,TH|0|0|0|0| 040600 XAddress =0x9B48 040610 XDataSize =0x1 040620 XAddrStep =-2 040650 XOutputDig =0x1 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x9B49 040710 YDataSize =0x1 040720 YAddrStep =-2 040750 YOutputDig =0x3 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x3CB1 000100 Cat0ID =0x8 000101 Cat1ID =0xFF 040005 Title ="Fuel Scaler for ACT to ECT" 040011 DescSize =0x103 040010 Desc ="FN022 - Do not edit first or last entries. Provides column scaling for the following tables;\r\n\r\n'Equilibrium Fuel Time Constant' (aka FN1322) \r\n'Equilibrium Intake Surface Fuel' (aka FN1321)\r\n'Fuel Base Table' (aka FN1307)\r\n'Fuel Startup Table' (aka FN1306)" 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x40 040200 ZEq =X,TH|0|0|0|0| 040203 XOutType =0x2 040304 YOutType =0x2 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x6 040305 Cols =0x1 040320 XUnits ="deg F" 040325 YUnits ="column" 040330 ZUnits ="" 040350 XLabels =ECT/ACT,Map Index 040352 XLabelType =0x4 040354 XEq =X*2,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/16,TH|0|0|0|0| 040600 XAddress =0x8CD2 040610 XDataSize =0x1 040620 XAddrStep =-2 040650 XOutputDig =0x1 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x8CD3 040710 YDataSize =0x1 040720 YAddrStep =-2 040750 YOutputDig =0x1 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x6012 000100 Cat0ID =0x8 000101 Cat1ID =0xFF 040005 Title ="Fuel Scaler for Load%" 040011 DescSize =0xA7 040010 Desc ="FN072A - Do not edit first or last entries. Provides row scaling for the following tables;\r\n\r\n'Fuel Base Table' (aka FN1307)\r\n'MFA Fuel Multiplier Table' (aka FN1328)" 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x300 040200 ZEq =X,TH|0|0|0|0| 040304 YOutType =0x2 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x7 040305 Cols =0x1 040320 XUnits ="load%" 040325 YUnits ="row" 040330 ZUnits ="" 040350 XLabels =Load,Table Row Index 040352 XLabelType =0x4 040354 XEq =X/327.68,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/16,TH|0|0|0|0| 040600 XAddress =0x8D16 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x8D18 040750 YOutputDig =0x1 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x44B7 000100 Cat0ID =0x8 000101 Cat1ID =0xFF 040005 Title ="Fuel Startup Scaler for Time" 040011 DescSize =0x71 040010 Desc ="FN018 - Do not edit first or last entries. Provides row scaling for the following table;\r\n\r\n'Fuel Startup Table'" 040020 SubType =0x7 040100 Address =0x0 040200 ZEq =X,TH|0|0|0|0| 040203 XOutType =0x2 040304 YOutType =0x2 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x7 040305 Cols =0x1 040320 XUnits ="sec" 040325 YUnits ="row" 040330 ZUnits ="" 040350 XLabels =Time,Table Column Index 040352 XLabelType =0x4 040354 XEq =X,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/16,TH|0|0|0|0| 040600 XAddress =0x8C90 040610 XDataSize =0x1 040620 XAddrStep =-2 040650 XOutputDig =0x1 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x8C91 040710 YDataSize =0x1 040720 YAddrStep =-2 040750 YOutputDig =0x1 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x6A64 000100 Cat0ID =0x1 040005 Title ="Fuel Startup Table" 040011 DescSize =0x14B 040010 Desc ="FN1306 - Subtracted from 'Fuel Base Table' for start up enrichment.\r\n\r\nWarning: The top row must always contain zeros to prevent post warmup enrichment still occuring.\r\n\r\nThe column input value is the ratio of ACT to ECT where the ACT contribution is defined by the 'ACT Fraction for Fuel Startup Table' (aka FRCSFT) parameter. \r\n" 040100 Address =0x9C40 040200 ZEq =X/128*14.64,TH|0|0|0|0| 040203 XOutType =0x4 040304 YOutType =0x4 040210 DecimalPl =0x3 040230 RangeLow =0.0000 040240 RangeHigh =10.0000 040300 Rows =0x8 040305 Cols =0xA 040320 XUnits ="deg F" 040325 YUnits ="secs" 040330 ZUnits ="A/F Ratio" 040350 XLabels =-30, 0, 30, 60, 90,120,150,180,210,240 040352 XLabelType =0x4 040354 XEq =X,TH|0|0|0|0| 040360 YLabels = 0, 3, 6, 10, 15, 25, 35, 45 040362 YLabelType =0x4 040364 YEq =X,TH|0|0|0|0| 040500 XLabelLink =0x3CB1 040505 XLabelSource =0x2 040510 YLabelLink =0x44B7 040515 YLabelSource =0x2 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x68EC 000100 Cat0ID =0x3 040005 Title ="HEGO Amplitude" 040011 DescSize =0xED 040010 Desc ="FN1352 - The maximum A/F ratio deviation (plus or minus) from stoichiometric that the A/F ratio oscillates between to form the rich and lean limits of closed loop fueling. The output value is referred to as the 'Peak to Peak Amplitude'." 040100 Address =0x9DA8 040200 ZEq =X/512*14.64,TH|0|0|0|0| 040203 XOutType =0x4 040304 YOutType =0x4 040230 RangeLow =0.0000 040240 RangeHigh =0.1000 040300 Rows =0x8 040305 Cols =0x4 040320 XUnits ="rpm" 040325 YUnits ="load" 040330 ZUnits ="A/F ratio" 040350 XLabels = 700, 900,1950,3000 040352 XLabelType =0x4 040354 XEq =X,TH|0|0|0|0| 040360 YLabels =0.05,0.10,0.20,0.30,0.40,0.50,0.60,0.75 040362 YLabelType =0x4 040364 YEq =X,TH|0|0|0|0| 040500 XLabelLink =0x5D5C 040505 XLabelSource =0x2 040510 YLabelLink =0x618F 040515 YLabelSource =0x2 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x61FA 000100 Cat0ID =0x3 040005 Title ="HEGO Bias" 040011 DescSize =0x120 040010 Desc ="FN1353 - These correction values are used to shift the averaged closed loop A/F ratio slightly away from stoichiometric to adjust emissions. \r\n\r\nPositive bias values will lean the A/F ratio (raise NOx but lower CO)\r\nNegative bias values will richen the A/F ratio (lower NOx but raise CO)" 040100 Address =0x9DC8 040150 Flags =0x1 040200 ZEq =X/2048*14.64,TH|0|0|0|0| 040203 XOutType =0x4 040304 YOutType =0x4 040210 DecimalPl =0x3 040230 RangeLow =-0.0200 040240 RangeHigh =0.0200 040300 Rows =0x8 040305 Cols =0x4 040320 XUnits ="rpm" 040325 YUnits ="load" 040330 ZUnits ="A/F ratio" 040350 XLabels = 700, 900,1950,3000 040352 XLabelType =0x4 040354 XEq =X,TH|0|0|0|0| 040360 YLabels =0.05,0.10,0.20,0.30,0.40,0.50,0.60,0.75 040362 YLabelType =0x4 040364 YEq =X,TH|0|0|0|0| 040500 XLabelLink =0x5D5C 040505 XLabelSource =0x2 040510 YLabelLink =0x618F 040515 YLabelSource =0x2 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x70C2 000100 Cat0ID =0x3 040005 Title ="HEGO Delay" 040011 DescSize =0x194 040010 Desc ="FN1351 - The time delay in revs per second from when a fuel change is made until the HEGO sensor detects this change. Prevents electrical noise in the system being incorrectly interpreted as a HEGO switch. Increase when the HEGO sensor is installed farther downstream from stock position. The result from this table lookup is used to calculate the exhaust pulse transport delay in both PIPs and seconds." 040100 Address =0x9D88 040200 ZEq =X/4,TH|0|0|0|0| 040203 XOutType =0x4 040304 YOutType =0x4 040230 RangeLow =0.0000 040240 RangeHigh =20.0000 040300 Rows =0x8 040305 Cols =0x4 040320 XUnits ="rpm" 040325 YUnits ="load" 040330 ZUnits ="rev per sec" 040350 XLabels = 700, 900,1950,3000 040352 XLabelType =0x4 040354 XEq =X,TH|0|0|0|0| 040360 YLabels =0.05,0.10,0.20,0.30,0.40,0.50,0.60,0.75 040362 YLabelType =0x4 040364 YEq =X,TH|0|0|0|0| 040500 XLabelLink =0x5D5C 040505 XLabelSource =0x2 040510 YLabelLink =0x618F 040515 YLabelSource =0x2 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x7A0F 000100 Cat0ID =0x1 000101 Cat1ID =0xFF 040005 Title ="HEGO Delay PIP Multiplier" 040011 DescSize =0x116 040010 Desc ="FN346 - A multiplier of the exhaust pulse transport delay in PIPs value used to calculate the expected number of PIPs that will occur before the HEGO detects a change in fueling.\r\n\r\nnb The input value of 'Bias/Peak to Peak Amplitude' is clamped to a maximum of 0.45 by the eec." 040020 SubType =0x7 040100 Address =0x0 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0xB 040305 Cols =0x1 040320 XUnits ="bias/ptpamp" 040325 YUnits ="multiplier" 040330 ZUnits ="" 040350 XLabels = 040352 XLabelType =0x4 040354 XEq =X/512,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/16,TH|0|0|0|0| 040600 XAddress =0x8D90 040610 XDataSize =0x1 040620 XAddrStep =-2 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x8D91 040710 YDataSize =0x1 040720 YAddrStep =-2 040750 YOutputDig =0x3 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x739C 000100 Cat0ID =0x1 000101 Cat1ID =0xFF 040005 Title ="HEGO Jumpback Multiplier with Bias" 040011 DescSize =0x312 040010 Desc ="FN344 - When a HEGO switch occurs during closed loop fuelling this is used as a multiplier of the sum of the 'Bias' and 'Peak to Peak Amplitude' (aka PTPAMP) values to determine the amount the desired A/F ratio should jumpback towards the averaged A/F ratio by.\r\n\r\nUsed when either of the two following conditions are met;\r\ni) the HEGO is reporting lean and the 'Bias' is rich (a negative value)\r\nii) the HEGO is reporting rich and the 'Bias' is lean (a positive value) or zero\r\notherwise the 'HEGO Jumpback Multiplier without Bias' (aka FN342) parameter is used.\r\n\r\nNotes:\r\n1) Larger Bias values result in smaller jumpback values.\r\n2) Do not enter multiplier values greater than '1.000'.\r\n3) The input value of 'Bias/Peak to Peak Amplitude' is clamped to a maximum of 0.45 by the eec." 040020 SubType =0x7 040100 Address =0x0 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x5 040305 Cols =0x1 040320 XUnits ="bias/ptpamp" 040325 YUnits ="multiplier" 040330 ZUnits ="" 040350 XLabels = 040352 XLabelType =0x4 040354 XEq =X/512,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/128,TH|0|0|0|0| 040600 XAddress =0x8D86 040610 XDataSize =0x1 040620 XAddrStep =-2 040650 XOutputDig =0x3 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x8D87 040710 YDataSize =0x1 040720 YAddrStep =-2 040750 YOutputDig =0x3 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x5AE 000100 Cat0ID =0x1 000101 Cat1ID =0xFF 040005 Title ="HEGO Jumpback Multiplier without Bias" 040011 DescSize =0x31B 040010 Desc ="FN342 - When a HEGO switch occurs during closed loop fuelling this is used as a multiplier of the 'Peak to Peak Amplitude' (aka PTPAMP) value to determine the amount the desired A/F ratio should jumpback towards the averaged A/F ratio by.\r\n\r\nUsed when either of the two following conditions are met;\r\ni) the HEGO is reporting lean and the 'Bias' is lean (a positive value) or zero\r\nii) the HEGO is reporting rich and the 'Bias' is rich (a negative value)\r\notherwise the 'HEGO Jumpback Multiplier with Bias' (aka FN344) parameter is used.\r\n\r\nNotes:\r\n1) Larger Bias values result in smaller jumpback values.\r\n2) Do not enter multiplier values greater than '1.000'.\r\n3) Do not alter the top two rows.\r\n4) The input value of 'Bias/Peak to Peak Amplitude' is clamped to a maximum of 0.45 by the eec." 040020 SubType =0x7 040100 Address =0x0 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x7 040305 Cols =0x1 040320 XUnits ="bias/ptpamp" 040325 YUnits ="multiplier" 040330 ZUnits ="" 040350 XLabels = 040352 XLabelType =0x4 040354 XEq =X/512,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/128,TH|0|0|0|0| 040600 XAddress =0x8D78 040610 XDataSize =0x1 040620 XAddrStep =-2 040650 XOutputDig =0x3 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x8D79 040710 YDataSize =0x1 040720 YAddrStep =-2 040750 YOutputDig =0x3 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x69DC 000100 Cat0ID =0x1 000101 Cat1ID =0xFF 040005 Title ="HEGO Ramp Rate Multiplier" 040011 DescSize =0x192 040010 Desc ="FN339 - During closed loop fuelling this table determines the rate at which the desired A/F ratio ramps richer or leaner towards the HEGO switch point. As the values in this table are very important for getting the fast and slow ramp rates correct when a Bias is used it should not normally be altered.\r\n\r\nnb The input value of 'Bias/Peak to Peak Amplitude' is clamped to a maximum of 0.45 by the eec." 040020 SubType =0x7 040100 Address =0x0 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x5 040305 Cols =0x1 040320 XUnits ="bias/ptpamp" 040325 YUnits ="multiplier" 040330 ZUnits ="" 040350 XLabels =X 040352 XLabelType =0x4 040354 XEq =X/512,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/256,TH|0|0|0|0| 040600 XAddress =0x8D6E 040610 XDataSize =0x1 040620 XAddrStep =-2 040650 XOutputDig =0x3 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x8D6F 040710 YDataSize =0x1 040720 YAddrStep =-2 040750 YOutputDig =0x3 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x43B5 000100 Cat0ID =0x1 000101 Cat1ID =0xFF 040005 Title ="High Speed Fuel Multiplier" 040011 DescSize =0x10C 040010 Desc ="FN396A - Open loop multiplier that adjusts the desired A/F ratio when the 'Speed Limiter Stage One On' threshold is exceeded.\r\nMultiplier values less than 1 increase fuel, values greater than 1 reduce fuel.\r\nSet to 0.996 when 'High Speed Spark Retard' is set to zero." 040020 SubType =0x7 040100 Address =0x0 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x7 040305 Cols =0x1 040320 XUnits ="mph" 040325 YUnits ="multiplier" 040330 ZUnits ="" 040350 XLabels = 040352 XLabelType =0x4 040354 XEq =X/2,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/256,TH|0|0|0|0| 040600 XAddress =0x981B 040610 XDataSize =0x1 040620 XAddrStep =-2 040650 XOutputDig =0x1 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x981C 040710 YDataSize =0x1 040720 YAddrStep =-2 040750 YOutputDig =0x3 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x253D 000100 Cat0ID =0x2 000101 Cat1ID =0xFF 040005 Title ="High Speed Spark Retard" 040011 DescSize =0xA6 040010 Desc ="FN179A - Deducted from PT and WOT spark calculations when the 'Speed Limiter Stage One On' threshold is exceeded. If set to zero adjust 'High Speed Fuel Multiplier'." 040020 SubType =0x7 040100 Address =0x0 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x7 040305 Cols =0x1 040320 XUnits ="mph" 040325 YUnits ="deg adv" 040330 ZUnits ="" 040350 XLabels = 040352 XLabelType =0x4 040354 XEq =X/2,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/4,TH|0|0|0|0| 040600 XAddress =0x980D 040610 XDataSize =0x1 040620 XAddrStep =-2 040650 XOutputDig =0x1 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x980E 040710 YDataSize =0x1 040720 YAddrStep =-2 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x20ED 000100 Cat0ID =0x6 000101 Cat1ID =0xFF 040005 Title ="Idle Adder for ACT" 040011 DescSize =0x7 040010 Desc ="FN825B" 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x40 040200 ZEq =X,TH|0|0|0|0| 040203 XOutType =0x2 040304 YOutType =0x2 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x7 040305 Cols =0x1 040320 XUnits ="deg F" 040325 YUnits ="rpm" 040330 ZUnits ="" 040350 XLabels =ACT 040352 XLabelType =0x4 040354 XEq =X*2,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X*8,TH|0|0|0|0| 040600 XAddress =0x8DD4 040610 XDataSize =0x1 040620 XAddrStep =-2 040650 XOutputDig =0x1 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x8DD5 040710 YDataSize =0x1 040720 YAddrStep =-2 040750 YOutputDig =0x1 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x3F90 000100 Cat0ID =0x6 000101 Cat1ID =0xFF 040005 Title ="Idle Adder for ECT" 040011 DescSize =0x7 040010 Desc ="FN825A" 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x40 040200 ZEq =X,TH|0|0|0|0| 040203 XOutType =0x2 040304 YOutType =0x2 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x8 040305 Cols =0x1 040320 XUnits ="deg F" 040325 YUnits ="rpm" 040330 ZUnits ="" 040350 XLabels =ECT 040352 XLabelType =0x4 040354 XEq =X*2,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X*8,TH|0|0|0|0| 040600 XAddress =0x8DC4 040610 XDataSize =0x1 040620 XAddrStep =-2 040650 XOutputDig =0x1 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x8DC5 040710 YDataSize =0x1 040720 YAddrStep =-2 040750 YOutputDig =0x1 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x6A16 000100 Cat0ID =0x6 000101 Cat1ID =0xFF 040005 Title ="Idle Airflow Drive" 040011 DescSize =0xBC 040010 Desc ="FN875D - The predicted idle airflow required to achieve the desired idle rpm when in drive at closed throttle.\r\n\r\nAlter if the air flow characteristics through the ISC valve have changed." 040020 SubType =0x7 040100 Address =0x0 040200 ZEq =X,TH|0|0|0|0| 040203 XOutType =0x2 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x6 040305 Cols =0x1 040320 XUnits ="desired rpm" 040325 YUnits ="lb/min" 040330 ZUnits ="" 040350 XLabels = 040352 XLabelType =0x4 040354 XEq =X*16,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/128,TH|0|0|0|0| 040600 XAddress =0x9390 040610 XDataSize =0x1 040620 XAddrStep =-2 040650 XOutputDig =0x1 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x9391 040710 YDataSize =0x1 040720 YAddrStep =-2 040750 YOutputDig =0x3 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x133E 000100 Cat0ID =0x6 040005 Title ="Idle Airflow Multiplier" 040011 DescSize =0x58 040010 Desc ="FN1861 - A multiplier of predicted idle airflow to adjust for ECT and time in run mode." 040100 Address =0x9366 040200 ZEq =X/64,TH|0|0|0|0| 040203 XOutType =0x4 040304 YOutType =0x4 040210 DecimalPl =0x3 040230 RangeLow =0.0000 040240 RangeHigh =250.0000 040300 Rows =0x6 040305 Cols =0x7 040320 XUnits ="deg F" 040325 YUnits ="secs" 040330 ZUnits ="multiplier" 040350 XLabels =-50, 0, 50,100,150,200,250 040352 XLabelType =0x4 040354 XEq =X,TH|0|0|0|0| 040360 YLabels = 0, 3, 5, 10, 20, 30 040362 YLabelType =0x4 040364 YEq =X,TH|0|0|0|0| 040500 XLabelLink =0xE7D 040505 XLabelSource =0x2 040510 YLabelLink =0x10B5 040515 YLabelSource =0x2 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x6E83 000100 Cat0ID =0x6 000101 Cat1ID =0xFF 040005 Title ="Idle Airflow Neutral" 040011 DescSize =0xBE 040010 Desc ="FN875N - The predicted idle airflow required to achieve the desired idle rpm when in neutral at closed throttle.\r\n\r\nAlter if the air flow characteristics through the ISC valve have changed." 040020 SubType =0x7 040100 Address =0x0 040200 ZEq =X,TH|0|0|0|0| 040203 XOutType =0x2 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x6 040305 Cols =0x1 040320 XUnits ="desired rpm" 040325 YUnits ="lb/min" 040330 ZUnits ="" 040350 XLabels = 040352 XLabelType =0x4 040354 XEq =X*16,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/128,TH|0|0|0|0| 040600 XAddress =0x939C 040610 XDataSize =0x1 040620 XAddrStep =-2 040650 XOutputDig =0x1 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x939D 040710 YDataSize =0x1 040720 YAddrStep =-2 040750 YOutputDig =0x3 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x835 000100 Cat0ID =0x6 000101 Cat1ID =0xFF 040005 Title ="Idle RPM Error Spark Multiplier Drive" 040011 DescSize =0xCD 040010 Desc ="FN841D - Aggressive closed throttle spark modifier used when in idle 'rpm control' or 'rpm lockout' mode. Outputs a spark multiplier to assist in the correction of any deviation from the desired idle rpm." 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x340 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x7 040305 Cols =0x1 040320 XUnits ="rpm delta" 040325 YUnits ="multiplier" 040330 ZUnits ="" 040350 XLabels = 040352 XLabelType =0x4 040354 XEq =X/4,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/128,TH|0|0|0|0| 040600 XAddress =0x92D6 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x92D8 040750 YOutputDig =0x3 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x1C14 000100 Cat0ID =0x6 000101 Cat1ID =0xFF 040005 Title ="Idle RPM Error Spark Multiplier Neutral" 040011 DescSize =0xCD 040010 Desc ="FN841N - Aggressive closed throttle spark modifier used when in idle 'rpm control' or 'rpm lockout' mode. Outputs a spark multiplier to assist in the correction of any deviation from the desired idle rpm." 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x340 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x7 040305 Cols =0x1 040320 XUnits ="rpm delta" 040325 YUnits ="multiplier" 040330 ZUnits ="" 040350 XLabels = 040352 XLabelType =0x4 040354 XEq =X/4,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/128,TH|0|0|0|0| 040600 XAddress =0x92F2 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x92F4 040750 YOutputDig =0x3 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x3109 000100 Cat0ID =0x6 000101 Cat1ID =0xFF 040005 Title ="Idle Spark Multiplier vs Dashpot" 040011 DescSize =0xD0 040010 Desc ="FN839 - Closed throttle spark modifier used when in idle 'dashpot control' mode following the transition from part throttle. Outputs a spark multiplier to assist in the stabilisation of the desired idle rpm." 040020 SubType =0x7 040100 Address =0x0 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x4 040305 Cols =0x1 040320 XUnits ="lb/min" 040325 YUnits ="multiplier" 040330 ZUnits ="" 040350 XLabels = 040352 XLabelType =0x4 040354 XEq =X/64,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/128,TH|0|0|0|0| 040600 XAddress =0x92CE 040610 XDataSize =0x1 040620 XAddrStep =-2 040650 XOutputDig =0x6 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x92CF 040710 YDataSize =0x1 040720 YAddrStep =-2 040750 YOutputDig =0x3 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x4587 000100 Cat0ID =0x6 000101 Cat1ID =0xFF 040005 Title ="Idle Startup Adder" 040011 DescSize =0x86 040010 Desc ="FN826A - Adds rpm to 'Desired Idle RPM' at startup for the duration specified by the 'Idle Startup Adder Time' (aka TKDTM) parameter." 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x40 040200 ZEq =X,TH|0|0|0|0| 040203 XOutType =0x2 040304 YOutType =0x2 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x7 040305 Cols =0x1 040320 XUnits ="deg F at start" 040325 YUnits ="rpm" 040330 ZUnits ="" 040350 XLabels = 040352 XLabelType =0x4 040354 XEq =X*2,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X*8,TH|0|0|0|0| 040600 XAddress =0x92C0 040610 XDataSize =0x1 040620 XAddrStep =-2 040650 XOutputDig =0x1 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x92C1 040710 YDataSize =0x1 040720 YAddrStep =-2 040750 YOutputDig =0x1 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x1284 000100 Cat0ID =0x1 000101 Cat1ID =0xFF 040005 Title ="Injector Breakpoint" 040011 DescSize =0x265 040010 Desc ="FN389 - The returned lookup value is multiplied by the rpm / 2 to determine the intersection point of the two injector slopes. If the desired fuel flow for a bank is less than or equal to this calculated value then only the 'Injector Low Slope' is used for the calculation of the injection pulsewidth otherwise both injector slopes are used. Use to correct AF ratio at idle when the Long Term Fuel Trims indicate adjustment is required by increasing the value to reduce fuel from the final calculated fuel pulsewidth. Has a diminishing effect from idle up to approximately 1500 rpm. Y conversion to be confirmed." 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x300 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x8 040305 Cols =0x1 040320 XUnits ="volts" 040325 YUnits ="lb/rev" 040330 ZUnits ="" 040350 XLabels =Battery Voltage 040352 XLabelType =0x4 040354 XEq =X/4096,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/268435456,TH|0|0|0|0| 040600 XAddress =0x922C 040650 XOutputDig =0x3 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x922E 040750 YOutputDig =0xA 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x64CC 000100 Cat0ID =0x7 040005 Title ="Injector Firing Order" 040011 DescSize =0x7 040010 Desc ="FN1329" 040100 Address =0x91B9 040200 ZEq =X,TH|0|0|0|0| 040203 XOutType =0x4 040304 YOutType =0x4 040210 DecimalPl =0x0 040230 RangeLow =0.0000 040240 RangeHigh =10.0000 040300 Rows =0x1 040305 Cols =0x8 040320 XUnits ="Injector to Fire" 040325 YUnits ="cylinder" 040330 ZUnits ="injector no." 040350 XLabels =-,-,-,-,-,-,-,- 040352 XLabelType =0x4 040354 XEq =X,TH|0|0|0|0| 040360 YLabels =cylinder 040362 YLabelType =0x4 040364 YEq =X,TH|0|0|0|0| 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x406D 000100 Cat0ID =0x7 000101 Cat1ID =0xFF 040005 Title ="Injector Offset vs Voltage" 040011 DescSize =0xB5 040010 Desc ="FN367 - Extra duration added to injector pulsewidth to compensate for battery voltage. Reduce for larger injectors by the ratio of the injector change. Curve should be exponential." 040020 SubType =0x7 040100 Address =0x0 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0xC 040305 Cols =0x1 040320 XUnits ="volts" 040325 YUnits ="mSecs" 040330 ZUnits ="" 040350 XLabels =Battery Voltage,Injector Offset 040352 XLabelType =0x4 040354 XEq =X/16,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/32,TH|0|0|0|0| 040600 XAddress =0x9B30 040610 XDataSize =0x1 040620 XAddrStep =-2 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x9B31 040710 YDataSize =0x1 040720 YAddrStep =-2 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%CONSTANT%% 000002 UniqueID =0x213E 000100 Cat0ID =0x7 020005 Title ="Number of Cylinders" 020011 DescSize =0x287 020010 Desc ="NUMCYL - If altered then the 'Engine Displacement' (aka SARCHG) conversion equation will need altering. The following parameters will need altering too:\r\n\r\n'Ignition Degrees Per PIP' (aka DEGPIP)\r\n'Injector Firing Order' (aka FN1329)\r\n'Injector Output Port' (aka FN1327)\r\n'Manifold Fast Fill Constant' (aka FKARC1)\r\n'Manifold Slow Fill Constant' (aka FKARCH)\r\n'Number of Injector Output Ports' (aka NUMOUT)\r\n'Number of PIPs Between Injector Outputs' (aka PIPOUT)\r\n'PIPs per Rev' (aka ENGCYL)\r\n'Signature PIP Difference Value' (aka MHPFD)\r\n'Signature PIP Multiplier Highest Value' (aka SIGKLU)\r\n'Signature PIP Multiplier Lowest Value' (aka SIGKLL)" 020020 Units ="no." 020050 SizeInBits =0x10 020100 Address =0x9AA8 020150 Flags =0x2 020200 Equation =X/32,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x6013 000100 Cat0ID =0x7 020005 Title ="Number of HEGOs" 020011 DescSize =0xA8 020010 Desc ="NUMEGO - Set to the number of hego sensors fitted. If converting from a stereo to a mono hego set up the 'Injector Output Port' (aka FN1327) table will need adjusting." 020020 Units ="no." 020100 Address =0x9E70 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x3781 000100 Cat0ID =0x9 020005 Title ="Number of HEGO Switches to Pass Test" 020011 DescSize =0x7 020010 Desc ="VEGOSW" 020020 Units ="no." 020100 Address =0x8EFF 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x5CCE 000100 Cat0ID =0x7 020005 Title ="Number of Injector Output Ports" 020011 DescSize =0x7 020010 Desc ="NUMOUT" 020020 Units ="no." 020100 Address =0x9AB0 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x5FCF 000100 Cat0ID =0x2 020005 Title ="Number of Pips Between Injector Outputs" 020011 DescSize =0x9 020010 Desc ="PIPOUT -" 020020 Units ="" 020050 SizeInBits =0x10 020100 Address =0x9AAC 020150 Flags =0x2 020200 Equation =X/32,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x52D8 000100 Cat0ID =0x11 020005 Title ="Off Button Maximum" 020011 DescSize =0x5D 020010 Desc ="HI_OFF - Highest value of Vehicle Speed Control Command Switch to indicate button depressed." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8E6E 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x52D9 000100 Cat0ID =0x11 020005 Title ="On Button Minimum" 020011 DescSize =0x5C 020010 Desc ="LOW_ON - Lowest value of Vehicle Speed Control Command Switch to indicate button depressed." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8E70 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x108D 000100 Cat0ID =0x2 020005 Title ="PIP Acceleration Limit" 020011 DescSize =0x4C 020010 Desc ="PACLIM - The maximum limit of PIP acceleration in percentage of PIP period." 020020 Units ="%" 020050 SizeInBits =0x10 020100 Address =0x9452 020150 Flags =0x2 020200 Equation =X/327.68,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x5B3C 000100 Cat0ID =0x2 020005 Title ="PIP Acceleration Offset" 020011 DescSize =0x9 020010 Desc ="PACOFF\r\n" 020020 Units ="(beta-cyl)/rev" 020050 SizeInBits =0x10 020100 Address =0x944E 020150 Flags =0x2 020200 Equation =X/65536,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x31E2 000100 Cat0ID =0x2 020005 Title ="PIP Acceleration Period" 020011 DescSize =0x7 020010 Desc ="PACPER" 020020 Units ="(rev-secs)/cyl" 020050 SizeInBits =0x10 020100 Address =0x944C 020150 Flags =0x2 020200 Equation =X/131072,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x563A 000100 Cat0ID =0x9 020005 Title ="PIP IDM Test Min RPM" 020011 DescSize =0x7 020010 Desc ="VLORPM" 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x8ED4 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x6530 000100 Cat0ID =0x9 020005 Title ="PIP Fault Time Out" 020011 DescSize =0x7 020010 Desc ="VPIPTM" 020020 Units ="mSecs" 020050 SizeInBits =0x10 020100 Address =0x8ED6 020150 Flags =0x2 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x5B3D 000100 Cat0ID =0x2 020005 Title ="PIP Period Slope" 020011 DescSize =0x78 020010 Desc ="PACSLO - Used in the calculation to determine the percentage of PIP that PIP will decrease during maximum acceleration." 020020 Units ="beta/sec" 020050 SizeInBits =0x10 020100 Address =0x9450 020150 Flags =0x2 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x4ACD 000100 Cat0ID =0x5 020005 Title ="PIP Recognition Time Delay" 020011 DescSize =0x3D 020010 Desc ="TKYON1 - Used to ignore any noise in the system at power up." 020020 Units ="secs" 020050 SizeInBits =0x10 020100 Address =0x9480 020150 Flags =0x2 020200 Equation =X/1024,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5FD0 000100 Cat0ID =0x1 020005 Title ="PIPs per Crank Injector Firing" 020011 DescSize =0xA 020010 Desc ="CRKPIP - " 020020 Units ="no." 020100 Address =0x9AAE 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x45E2 000100 Cat0ID =0x7 020005 Title ="PIPs per Rev" 020011 DescSize =0x2F 020010 Desc ="ENGCYL - Number of PIPs per engine revolution." 020020 Units ="pips" 020100 Address =0x9E61 020200 Equation =X/2,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0xE6 000100 Cat0ID =0x2 020005 Title ="PT Spark Adder" 020011 DescSize =0x5 020010 Desc ="KPS1" 020020 Units ="deg adv" 020050 SizeInBits =0x10 020100 Address =0x9434 020150 Flags =0x3 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x5AD1 000100 Cat0ID =0x2 020005 Title ="PT Spark Multiplier" 020011 DescSize =0x2 020010 Desc ="Y" 020020 Units ="multiplier" 020100 Address =0x943E 020200 Equation =X/128,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x4276 000100 Cat0ID =0xD 020005 Title ="Purge Cold Start Delay #1" 020011 DescSize =0x7 020010 Desc ="PRGTD1" 020020 Units ="secs" 020100 Address =0x93F9 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x3DDD 000100 Cat0ID =0xD 020005 Title ="Purge Cold Start Delay #2" 020011 DescSize =0x7 020010 Desc ="PRGTD4" 020020 Units ="secs" 020100 Address =0x93FA 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x6D92 000100 Cat0ID =0xD 020005 Title ="Purge Hot Start Delay" 020011 DescSize =0x7 020010 Desc ="PRGTD3" 020020 Units ="secs" 020100 Address =0x93F6 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x3B71 000100 Cat0ID =0xD 020005 Title ="Purge Warm Start Delay #1" 020011 DescSize =0x7 020010 Desc ="PRGTD2" 020020 Units ="secs" 020100 Address =0x93F7 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x2DC 000100 Cat0ID =0xD 020005 Title ="Purge Warm Start Delay #2" 020011 DescSize =0x7 020010 Desc ="PRGTD5" 020020 Units ="secs" 020100 Address =0x93F8 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x58D4 000100 Cat0ID =0xD 020005 Title ="Purge Max ECT" 020011 DescSize =0x45 020010 Desc ="CTPRG - The temperature above which canister purge is not permitted." 020020 Units ="deg F" 020100 Address =0x93ED 020150 Flags =0x1 020200 Equation =X*2,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x69C 000100 Cat0ID =0xD 020005 Title ="Purge Max ECT Hysteresis" 020011 DescSize =0x7 020010 Desc ="CTPRGH" 020020 Units ="deg F" 020100 Address =0x93EE 020150 Flags =0x1 020200 Equation =X*2,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x749D 000100 Cat0ID =0xD 020005 Title ="Purge PT and WOT Delay Time" 020011 DescSize =0x7 020010 Desc ="EVTDOT" 020020 Units ="secs" 020100 Address =0x93F0 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x347C 000100 Cat0ID =0xD 020005 Title ="Purge Test Disable" 020011 DescSize =0xB1 020010 Desc ="Z_VPRG - Normally this is set to\"7C28\", change to \"420\" to prevent the canister purge solenoid test being performed.\r\n\r\nWARNING: Do not enter any value other than one of these." 020020 Units ="" 020050 SizeInBits =0x10 020100 Address =0x7A13 020150 Flags =0x2 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x3 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x52DE 000100 Cat0ID =0x11 020005 Title ="Resume Button Minimum" 020011 DescSize =0x5C 020010 Desc ="LRESUM - Lowest value of Vehicle Speed Control Command Switch to indicate button depressed." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8E7A 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x52DF 000100 Cat0ID =0x11 020005 Title ="Resume Button Maximum" 020011 DescSize =0x5C 020010 Desc ="HRESUM - Higest value of Vehicle Speed Control Command Switch to indicate button depressed." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8E7C 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x3E67 000100 Cat0ID =0x4 020005 Title ="Rev Limit Clear RPM" 020011 DescSize =0x98 020010 Desc ="NLM_CL - Always set lower then the 'Rev Limit Set RPM' (aka NLM_SH) parameter. Fuel delivery remains cut until the engine speed drops below this limit." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x9A84 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x1E53 000100 Cat0ID =0x4 020005 Title ="Rev Limit No Fuel" 020011 DescSize =0xA1 020010 Desc ="NLMT - Very harsh limiter, cuts all fuel delivery, always set higher than 'Rev Limit Set RPM' (aka NLM_SH) parameter.\r\n\r\nDoes not appear to be used in this ecu." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x9A94 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x4B3E 000100 Cat0ID =0x4 020005 Title ="Rev Limit No Fuel Hysteresis" 020011 DescSize =0x70 020010 Desc ="NLMTH - Hysteresis rpm for 'Rev Limit No Fuel' (aka NLMT) parameter.\r\n\r\nDoes not appear to be used in this ecu." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x9A96 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x2458 000100 Cat0ID =0x4 020005 Title ="Rev Limit Set RPM" 020011 DescSize =0xC1 020010 Desc ="NLM_SH - Always set higher then the 'Rev Limit Clear RPM' (aka NLM_CL) parameter. Fuel delivery remains cut until the engine speed drops below the 'Rev Limit Clear RPM' (aka NLM_CL) parameter." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x9A82 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x306 000100 Cat0ID =0x5 020005 Title ="RPM Average Time Constant" 020011 DescSize =0xDF 020010 Desc ="TCNDBR - The time constant for the rolling average calculation of the 'RPM Average' (aka NDBAR) value.\r\n\r\nLarger time constant values increase the time lag of the value being updated but reduce unwanted transients from it." 020020 Units ="secs" 020050 SizeInBits =0x10 020100 Address =0x9804 020150 Flags =0x2 020200 Equation =X/1024,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x7E3A 000100 Cat0ID =0x5 020005 Title ="RPM Time Constant" 020011 DescSize =0xD0 020010 Desc ="TCN - The time constant for the rolling average calculation of the 'RPM' (aka N) value.\r\n\r\nLarger time constant values increase the time lag of the value being updated but reduce unwanted transients from it." 020020 Units ="secs" 020050 SizeInBits =0x10 020100 Address =0x97F4 020150 Flags =0x2 020200 Equation =X/1024,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5EB8 000100 Cat0ID =0x2 020005 Title ="RPM to MPH Ratio for First Gear" 020011 DescSize =0xEE 020010 Desc ="TTNOV - If the rpm is greater than the result of multiplying the average speed by this parameter then the result of the 'Torque Reduction Table' lookup is subtracted from the final spark advance value.\r\n\r\nMulitplier needs to be confirmed" 020020 Units ="rpm/mph" 020100 Address =0x9448 020200 Equation =X*4,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x1FBD 000100 Cat0ID =0x9 020005 Title ="SCVAC Open Circuit Check" 020011 DescSize =0xA 020010 Desc ="OCCDTB - " 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8F8C 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x7989 000100 Cat0ID =0x9 020005 Title ="SCVNT Open Circuit Check" 020011 DescSize =0xA 020010 Desc ="OCCDTA - " 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8F8A 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x1AAC 000100 Cat0ID =0x9 020005 Title ="Self Test Desired RPM" 020011 DescSize =0x6 020010 Desc ="VISCN" 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x9E8C 020150 Flags =0x2 020200 Equation =X*8,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0xDAA 000100 Cat0ID =0x9 020005 Title ="Self Test Ramp Lean Rate" 020011 DescSize =0x7 020010 Desc ="VIPLR1" 020020 Units ="A/F ratio/sec" 020050 SizeInBits =0x10 020100 Address =0x8EB0 020150 Flags =0x2 020200 Equation =X/32768*14.64,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x48CD 000100 Cat0ID =0x9 020005 Title ="Self Test Ramp Rich Rate" 020011 DescSize =0x7 020010 Desc ="VIPRR1" 020020 Units ="A/F ratio/sec" 020050 SizeInBits =0x10 020100 Address =0x8EAE 020150 Flags =0x2 020200 Equation =X/32768*14.64,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x274E 000100 Cat0ID =0x9 020005 Title ="Self Test Ramp Rich Time Delay" 020011 DescSize =0x6 020010 Desc ="VDLY1" 020020 Units ="sec" 020100 Address =0x8FB0 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5444 000100 Cat0ID =0x9 020005 Title ="Self Test Set Speed Proportional Gain" 020011 DescSize =0x29 020010 Desc ="VSTGN - Multiplier of 'Set Speed' value." 020020 Units ="dutycycle/mph" 020050 SizeInBits =0x10 020100 Address =0x8FB4 020150 Flags =0x2 020200 Equation =X/16384,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x20EF 000100 Cat0ID =0x9 020005 Title ="Self Test Vehicle Speed Proportional Gain" 020011 DescSize =0x6 020010 Desc ="VVHGN" 020020 Units ="dutycycle/mph" 020050 SizeInBits =0x10 020100 Address =0x8FB6 020150 Flags =0x2 020200 Equation =X/16384,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5342 000100 Cat0ID =0x11 020005 Title ="Set Speed Max Increment" 020011 DescSize =0x56 020010 Desc ="ACLDED - The maximum increment above vehicle speed to which 'Set Speed' can increase." 020020 Units ="mph" 020050 SizeInBits =0x10 020100 Address =0x8E96 020150 Flags =0x2 020200 Equation =X/512,TH|0|0|0|0| 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x530F 000100 Cat0ID =0x11 020005 Title ="Set Speed Proportional Gain" 020011 DescSize =0x6 020010 Desc ="SETGN" 020020 Units ="multiplier" 020050 SizeInBits =0x10 020100 Address =0x8E84 020150 Flags =0x2 020200 Equation =X/16384,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x27D3 000100 Cat0ID =0x7 020005 Title ="Shift Indicator Light On Time" 020011 DescSize =0x95 020010 Desc ="SLTIM2 - The maximum time the shift indicator light is illuminated for following the minimum elapsed time of the 'Shift Indicator Light Time Delay'." 020020 Units ="secs" 020100 Address =0x8C11 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x4AE2 000100 Cat0ID =0x7 020005 Title ="Shift Indicator Light RPM" 020011 DescSize =0x6B 020010 Desc ="SHIRPM - The shift indicator light is turned on at this rpm regardless of any other condition evaluations." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x8C0E 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x7CF3 000100 Cat0ID =0x7 020005 Title ="Shift Indicator Light Time Delay" 020011 DescSize =0x76 020010 Desc ="SLTIM1 - The minimum elapsed time of the SIL_Timer required in order for the shift indicator light to be illuminated." 020020 Units ="secs" 020100 Address =0x8C10 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x2C88 000100 Cat0ID =0x7 020005 Title ="Shift Indicator Light Timer Enable RPM" 020011 DescSize =0x6E 020010 Desc ="SPTRPM - The rpm at which the SIL_Timer is checked to see if the shift indicator light should be illuminated." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x8C0C 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x5D8C 000100 Cat0ID =0x2 020005 Title ="Signature PIP Difference Value" 020011 DescSize =0xDB 020010 Desc ="MHPFD - Permitted values are;\r\n\r\n8 cylinder, signature dutycycle <= 35% = 0.20\r\n6 cylinder, signature dutycycle <= 30% = 0.24\r\n4 cylinder, signature dutycycle <= 30% = 0.29\r\nSignature PIP distributor not present = 0.99" 020020 Units ="" 020050 SizeInBits =0x10 020100 Address =0x9E68 020150 Flags =0x2 020200 Equation =X/65536,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x100A 000100 Cat0ID =0x2 020005 Title ="Signature PIP Half Period Multiplier Filter Constant" 020011 DescSize =0xA 020010 Desc ="FKSKAY - " 020020 Units ="" 020050 SizeInBits =0x10 020100 Address =0x8E5E 020150 Flags =0x2 020200 Equation =X/65536,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x2CE6 000100 Cat0ID =0x2 020005 Title ="Signature PIP Multiplier Highest Value" 020011 DescSize =0x5B 020010 Desc ="SIGKLU - 1.99996 for 30% dutycycle signature PIP, 1.66666 for 35% dutycycle signature PIP." 020020 Units ="multiplier" 020050 SizeInBits =0x10 020100 Address =0x8E62 020150 Flags =0x2 020200 Equation =X/32768,TH|0|0|0|0| 020210 DecimalPl =0x5 %%END%% %%CONSTANT%% 000002 UniqueID =0x6181 000100 Cat0ID =0x2 020005 Title ="Signature PIP Multiplier Lowest Value" 020011 DescSize =0x5B 020010 Desc ="SIGKLL - 1.42857 for 30% dutycycle signature PIP, 1.25000 for 35% dutycycle signature PIP." 020020 Units ="multiplier" 020050 SizeInBits =0x10 020100 Address =0x8E60 020150 Flags =0x2 020200 Equation =X/32768,TH|0|0|0|0| 020210 DecimalPl =0x5 %%END%% %%CONSTANT%% 000002 UniqueID =0x6853 000100 Cat0ID =0x2 020005 Title ="Spark/Fuel Lug Time Limit" 020011 DescSize =0x49 020010 Desc ="LUGTIM - The maximum value that the 'Lugging Timer' (aka LUGTMR) can be." 020020 Units ="secs" 020100 Address =0x943F 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5B06 000100 Cat0ID =0x2 020005 Title ="Spark Adder for Neutral" 020011 DescSize =0x77 020010 Desc ="NSADD - If in neutral, this is added to the 'CT Spark vs RPM' lookup value when startup kicker adjustment is not used." 020020 Units ="deg adv" 020050 SizeInBits =0x10 020100 Address =0x9442 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x2AD2 000100 Cat0ID =0x2 020005 Title ="Spark Advance Limit" 020011 DescSize =0x7 020010 Desc ="SPKLIM" 020020 Units ="%" 020050 SizeInBits =0x10 020100 Address =0x9476 020150 Flags =0x2 020200 Equation =X/327.68,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0xC27 000100 Cat0ID =0x2 020005 Title ="Spark Advance Limit PIP%" 020011 DescSize =0x42 020010 Desc ="SPTADV - The percentage of PIP that the spark may be advanced by." 020020 Units ="%" 020050 SizeInBits =0x10 020100 Address =0x9454 020150 Flags =0x2 020200 Equation =X/327.68,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x4AE6 000100 Cat0ID =0x2 020005 Title ="Spark Interpolation Inhibit" 020011 DescSize =0x139 020010 Desc ="Z_SPKINT - Normally set to \"1E4\", change to \"194\" to eliminate the eec's use of the 'Spark Altitude Table' (aka FN905A) parameter. When using this code modifier the eec will use the 'Spark Sea Level Table' (aka FN904A) regardless of barometric pressure.\r\n\r\nWARNING: Do not use any values other than one of these." 020020 Units ="n/a" 020050 SizeInBits =0x10 020100 Address =0x5713 020150 Flags =0x2 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x3 020210 DecimalPl =0x1 020230 RangeLow =-10.0000 020240 RangeHigh =55.0000 %%END%% %%CONSTANT%% 000002 UniqueID =0x5D7F 000100 Cat0ID =0x2 020005 Title ="Spark Limit Max" 020011 DescSize =0x7 020010 Desc ="SPUCLP" 020020 Units ="deg adv" 020100 Address =0x943D 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x4E11 000100 Cat0ID =0x2 020005 Title ="Spark Limit Min" 020011 DescSize =0x7 020010 Desc ="SPLCLP" 020020 Units ="deg adv" 020100 Address =0x943C 020200 Equation =X/4,TH|0|0|0|0| 020230 RangeLow =-10.0000 020240 RangeHigh =55.0000 %%END%% %%CONSTANT%% 000002 UniqueID =0xF1A 000100 Cat0ID =0x2 020005 Title ="Spark Max PIP RPM" 020011 DescSize =0x7 020010 Desc ="SPKSWL" 020020 Units ="clock ticks" 020050 SizeInBits =0x10 020100 Address =0x9444 020150 Flags =0x2 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x6591 000100 Cat0ID =0x2 020005 Title ="Spark Min PIP RPM" 020011 DescSize =0x7 020010 Desc ="SPKSWH" 020020 Units ="clock ticks" 020050 SizeInBits =0x10 020100 Address =0x9446 020150 Flags =0x2 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x5482 000100 Cat0ID =0x9 020005 Title ="Spark Test Advance" 020011 DescSize =0x7 020010 Desc ="VIPSPK" 020020 Units ="deg adv" 020050 SizeInBits =0x10 020100 Address =0x8EAA 020150 Flags =0x3 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x1EA3 000100 Cat0ID =0x2 020005 Title ="Spark Tip In Advance Per PIP" 020011 DescSize =0x7 020010 Desc ="TIPINC" 020020 Units ="deg adv" 020100 Address =0x9463 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x45C6 000100 Cat0ID =0x2 020005 Title ="Spark Tip In Max RPM" 020011 DescSize =0x9C 020010 Desc ="NTIP - The maximum rpm allowed in order to a spark tip in condition to be recognised. Must be set to less than 2000 rpm to ensure correct tip in ramp back." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x946E 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x287 000100 Cat0ID =0x2 020005 Title ="Spark Tip In Min ECT" 020011 DescSize =0x56 020010 Desc ="ECTIP - The minimum ECT allowed in order to a spark tip in condition to be recognised" 020020 Units ="deg F" 020100 Address =0x946D 020150 Flags =0x1 020200 Equation =X*2,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x1681 000100 Cat0ID =0x2 020005 Title ="Spark Tip In Retard" 020011 DescSize =0x3C 020010 Desc ="TIPMAX - The amount of spark retard pulled during a tip in." 020020 Units ="deg adv" 020100 Address =0x9462 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x6538 000100 Cat0ID =0x2 020005 Title ="Spark Tip In TP" 020011 DescSize =0x64 020010 Desc ="KACRAT - The change in throttle position required when closing for a spark tip in to be recognised." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x945E 020150 Flags =0x3 020200 Equation =X/6400,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x49AA 000100 Cat0ID =0x4 020005 Title ="Speed Limiter Stage One Off" 020011 DescSize =0xB7 020010 Desc ="HVS_CL - Always set lower then the 'Speed Limiter Stage One On'. AF ratio is enrichened and spark retarded until the engine speed drops below this limit. Set to 127.5 mph to disable." 020020 Units ="mph" 020100 Address =0x9A89 020200 Equation =X/2,TH|0|0|0|0| 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x2507 000100 Cat0ID =0x4 020005 Title ="Speed Limiter Stage One On" 020011 DescSize =0xD8 020010 Desc ="HVS_SH - Speed at which AF ratio is enrichened and spark retarded until the engine speed drops below the 'First Speed Limiter Off'. Always set higher then the 'First Speed Limiter Off'. Set to 127.5 mph to disable." 020020 Units ="mph" 020100 Address =0x9A88 020200 Equation =X/2,TH|0|0|0|0| 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x12AD 000100 Cat0ID =0x4 020005 Title ="Speed Limiter Stage Two Off" 020011 DescSize =0xAF 020010 Desc ="VVS_CL - Always set lower then the 'Speed Limiter Stage Two On'. Fuel delivery remains cut in half until the engine speed drops below this limit. Set to 127.5 mph to disable." 020020 Units ="mph" 020100 Address =0x9A87 020200 Equation =X/2,TH|0|0|0|0| 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x8B9 000100 Cat0ID =0x4 020005 Title ="Speed Limiter Stage Two On" 020011 DescSize =0x109 020010 Desc ="VVS_SH - Speed at which the injectors are fired alternately to limit speed. Fuel delivery remains cut in half until the engine speed drops below the 'Speed Limiter Stage Two Off'. Always set higher then the 'Second Speed Limiter Off'. Set to 127.5 mph to disable." 020020 Units ="mph" 020100 Address =0x9A86 020200 Equation =X/2,TH|0|0|0|0| 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x4EBD 000100 Cat0ID =0x7 020005 Title ="Speed Sensor Present" 020011 DescSize =0x86 020010 Desc ="VSTYPE - \r\n0 = no vehicle speed sensor present\r\n1 = vehicle speed sensor present\r\n2 = vehicle speed sensor and cruise control present" 020020 Units ="none" 020100 Address =0x8EA1 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x3251 000100 Cat0ID =0x9 020005 Title ="SPOUT Test Min RPM" 020011 DescSize =0x3A 020010 Desc ="VSPRPM - The minimum rpm required to pass the SPOUT test." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x8FA8 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x42C3 000100 Cat0ID =0x9 020005 Title ="SPOUT Test Min Time" 020011 DescSize =0xA1 020010 Desc ="VSPTDL - The minimum time required since the spark advance has been set to the 'SPOUT Test Spark Advance' (aka VSPADV) value before the SPOUT test can continue." 020020 Units ="secs" 020100 Address =0x8FAF 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x1F50 000100 Cat0ID =0x9 020005 Title ="SPOUT Test Spark Advance" 020011 DescSize =0x7 020010 Desc ="VSPADV" 020020 Units ="deg adv" 020050 SizeInBits =0x10 020100 Address =0x8FAA 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x7900 000100 Cat0ID =0x9 020005 Title ="SPOUT Test Spark Retard" 020011 DescSize =0x7 020010 Desc ="VSPRET" 020020 Units ="deg adv" 020050 SizeInBits =0x10 020100 Address =0x8FAC 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x278B 000100 Cat0ID =0x5 020005 Title ="Stall RPM" 020011 DescSize =0x37 020010 Desc ="STALLN\r\n\r\nDoes not appear to be used in this strategy." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x9E62 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x54A8 000100 Cat0ID =0x1 020005 Title ="Startup Fuel Multiplier" 020011 DescSize =0x1CE 020010 Desc ="NUMPR - A multiplier of the 'CT Neutral Fuel Multiplier vs RPM' (aka FN301N) lookup result used when the following conditions are met;\r\n\r\nThe ECT at startup is between the 'Cold Start Max ECT' (aka CTLOW) and 'Startup Fuel Multiplier Max ECT' (aka CTHIN) parameter values.\r\nThe time since start is less than the 'Startup Fuel Multiplier Time Delay' (aka OLMTD1) parameter value.\r\n\r\nMultiplier values less than 1 increase fuel, values greater than 1 reduce fuel." 020020 Units ="multiplier" 020100 Address =0x8FE1 020200 Equation =X/128,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0xF3E 000100 Cat0ID =0x1 020005 Title ="Startup Fuel Multiplier Max ECT" 020011 DescSize =0x49 020010 Desc ="CTHIN - The maximum ECT at startup to use the 'Startup Fuel Multiplier'." 020020 Units ="deg F" 020100 Address =0x8FE0 020150 Flags =0x1 020200 Equation =X*2,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x54A9 000100 Cat0ID =0x1 020005 Title ="Startup Fuel Multiplier Time Delay" 020011 DescSize =0x4C 020010 Desc ="OLMTD1 - The maximum time since start to use the 'Startup Fuel Multiplier'." 020020 Units ="secs" 020100 Address =0x8FE2 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x515A 000100 Cat0ID =0x2 020005 Title ="Startup Kicker Min RPM" 020011 DescSize =0x74 020010 Desc ="HCSD - The minimum rpm for the 'CT Spark Subtractor for BP' table to be used. See also 'Startup Kicker Time Delay'." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x9436 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x3793 000100 Cat0ID =0x2 020005 Title ="Startup Kicker Min RPM Hysteresis" 020011 DescSize =0x3B 020010 Desc ="HCSDH - Hysteresis for the 'Startup Kicker Min RPM' value." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x9438 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x274D 000100 Cat0ID =0x5 020005 Title ="Steady State Factor" 020011 DescSize =0x36 020010 Desc ="SSFCTR - Used in MKAY and signature KAY calculations." 020020 Units ="multiplier" 020050 SizeInBits =0x10 020100 Address =0x8C0A 020150 Flags =0x2 020200 Equation =X/65536,TH|0|0|0|0| 020210 DecimalPl =0x5 %%END%% %%CONSTANT%% 000002 UniqueID =0x5ADC 000100 Cat0ID =0x7 020005 Title ="Supercharger Bypass Throttle Breakpoint" 020011 DescSize =0xD8 020010 Desc ="THBPSC - Value added to closed throttle value to establish the minimum throttle position at which the supercharger bypass valve is opened. Requires 'Auxillary Hardware Present' (aka THRMHP) parameter to be set to 2." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8E64 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x3ABE 000100 Cat0ID =0x7 020005 Title ="Supercharger Bypass Throttle Breakpoint Hysteresis" 020011 DescSize =0xDE 020010 Desc ="THBPSH - Value subtracted from combined 'Supercharger Bypass Throttle Breakpoint' and closed throttle value to establish throttle position below which the supercharger bypass valve is closed. Typically set at 0.120 volts." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8E66 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x1D9C 000100 Cat0ID =0x7 020005 Title ="Thermactor Bypass Cold Start Delay #1" 020011 DescSize =0x7 020010 Desc ="BYSTM1" 020020 Units ="secs" 020100 Address =0x93B9 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x78D2 000100 Cat0ID =0x7 020005 Title ="Thermactor Bypass Cold Start Delay #2" 020011 DescSize =0x7 020010 Desc ="BYSTM4" 020020 Units ="secs" 020100 Address =0x93BA 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x12E2 000100 Cat0ID =0x7 020005 Title ="Thermactor Bypass Hot Start Delay" 020011 DescSize =0x7 020010 Desc ="BYSTM3" 020020 Units ="secs" 020100 Address =0x93B6 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x53C8 000100 Cat0ID =0x7 020005 Title ="Thermactor Bypass Hysteresis" 020011 DescSize =0x7C 020010 Desc ="CTBYSH - Hysteresis for the 'Thermactor Bypass Min ACT' (aka ATBYS) and 'Thermactor Bypass Min ECT' (aka CTBYS) parameters." 020020 Units ="deg F" 020100 Address =0x93C0 020150 Flags =0x2 020200 Equation =X*2,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x5D0D 000100 Cat0ID =0x7 020005 Title ="Thermactor Bypass Min ACT" 020011 DescSize =0x52 020010 Desc ="ATBYS - The minimum ACT at which no thermactor air is added to the exhaust gases." 020020 Units ="deg F" 020100 Address =0x93BE 020150 Flags =0x1 020200 Equation =X*2,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x57A5 000100 Cat0ID =0x7 020005 Title ="Thermactor Bypass Min ECT" 020011 DescSize =0x52 020010 Desc ="CTBYS - The minimum ECT at which no thermactor air is added to the exhaust gases." 020020 Units ="deg F" 020100 Address =0x93BF 020150 Flags =0x2 020200 Equation =X*2,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x39B6 000100 Cat0ID =0x7 020005 Title ="Thermactor Bypass Warm Start Delay #1" 020011 DescSize =0x7 020010 Desc ="BYSTM2" 020020 Units ="secs" 020100 Address =0x93B7 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x5D7C 000100 Cat0ID =0x7 020005 Title ="Thermactor Bypass Warm Start Delay #2" 020011 DescSize =0x7 020010 Desc ="BYSTM5" 020020 Units ="secs" 020100 Address =0x93B8 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x3260 000100 Cat0ID =0x7 020005 Title ="Thermactor Bypass WOT Time Delay" 020011 DescSize =0x7 020010 Desc ="BYPWOT" 020020 Units ="secs" 020100 Address =0x93BD 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x718 000100 Cat0ID =0x7 020005 Title ="Thermactor Decel Upstream Air Max RPM" 020011 DescSize =0x7 020010 Desc ="UPRPM2" 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x93C4 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x363F 000100 Cat0ID =0x7 020005 Title ="Thermactor Decel Upstream Air Max RPM Hysteresis" 020011 DescSize =0x7 020010 Desc ="UPRPMH" 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x93C2 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x580A 000100 Cat0ID =0x7 020005 Title ="Thermactor Delay Time for MFA" 020011 DescSize =0x7 020010 Desc ="DMPDLY" 020020 Units ="secs" 020100 Address =0x93DF 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x6F18 000100 Cat0ID =0x7 020005 Title ="Thermactor Delay Time for Open Throttle" 020011 DescSize =0x7 020010 Desc ="DNSTMI" 020020 Units ="secs" 020100 Address =0x93D8 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x4BE6 000100 Cat0ID =0x7 020005 Title ="Thermactor Downstream Air Max Load" 020011 DescSize =0x6 020010 Desc ="DNLOD" 020020 Units ="load" 020050 SizeInBits =0x10 020100 Address =0x93D4 020150 Flags =0x2 020200 Equation =X/327.68,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x583A 000100 Cat0ID =0x7 020005 Title ="Thermactor Downstream Air Max Load Hysteresis" 020011 DescSize =0x48 020010 Desc ="DNLODH - Hysteresis for the 'Thermactor Downstream Air Max Load' value." 020020 Units ="load" 020050 SizeInBits =0x10 020100 Address =0x93D6 020150 Flags =0x2 020200 Equation =X/327.68,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x43DE 000100 Cat0ID =0x9 020005 Title ="Thermactor Downstream Air Test Wait" 020011 DescSize =0x7 020010 Desc ="VATMR2" 020020 Units ="secs" 020100 Address =0x8FB3 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x6D88 000100 Cat0ID =0x7 020005 Title ="Thermactor Upstream Air Cold Start Delay #1" 020011 DescSize =0x7 020010 Desc ="UPSTM1" 020020 Units ="secs" 020100 Address =0x93D1 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x5FDF 000100 Cat0ID =0x7 020005 Title ="Thermactor Upstream Air Cold Start Delay #2" 020011 DescSize =0x7 020010 Desc ="UPSTM4" 020020 Units ="secs" 020100 Address =0x93D2 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x6495 000100 Cat0ID =0x7 020005 Title ="Thermactor Upstream Air Decel Time Delay" 020011 DescSize =0x7 020010 Desc ="CTARTM" 020020 Units ="secs" 020100 Address =0x93C6 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x9AB 000100 Cat0ID =0x9 020005 Title ="Thermactor Upstream Air Dump Time Delay" 020011 DescSize =0x6 020010 Desc ="VDLY2" 020020 Units ="secs" 020100 Address =0x8FB1 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x767A 000100 Cat0ID =0x7 020005 Title ="Thermactor Upstream Air Hot Start Delay" 020011 DescSize =0x7 020010 Desc ="UPSTM3" 020020 Units ="secs" 020100 Address =0x93CE 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x27DE 000100 Cat0ID =0x7 020005 Title ="Thermactor Upstream Air Max Time" 020011 DescSize =0x104 020010 Desc ="HMSTM - If the time since start is less than this value then thermactor upstream air is permitted providing the 'Thermactor Upstream WOT Time Delay' (aka UPSWOT) delay has not been exceeded. Setting to 255 will inhibit the use of this time limiting parameter." 020020 Units ="secs" 020100 Address =0x93C7 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x7F0 000100 Cat0ID =0x7 020005 Title ="Thermactor Upstream Air Time Delay" 020011 DescSize =0x9 020010 Desc ="HMCTM - " 020020 Units ="secs" 020100 Address =0x93C7 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x29B4 000100 Cat0ID =0x7 020005 Title ="Thermactor Upstream Air Timer Min Load%" 020011 DescSize =0x6E 020010 Desc ="UPLOD - If the load% drops below this value when the 'Upstream Air Timer' is running then the timer is reset." 020020 Units ="load%" 020050 SizeInBits =0x10 020100 Address =0x93CA 020150 Flags =0x2 020200 Equation =X/327.68,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x63FE 000100 Cat0ID =0x7 020005 Title ="Thermactor Upstream Air Timer Min Load% Hysteresis" 020011 DescSize =0x91 020010 Desc ="UPLODH - If load% is greater than the sum of this value plus the 'Upstream Air Timer Min Load' value then the 'Upstream Air Timer' is activated." 020020 Units ="load%" 020050 SizeInBits =0x10 020100 Address =0x93CC 020150 Flags =0x2 020200 Equation =X/327.68,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0xF43 000100 Cat0ID =0x7 020005 Title ="Thermactor Upstream Air Warm Start Delay #1" 020011 DescSize =0x7 020010 Desc ="UPSTM2" 020020 Units ="secs" 020100 Address =0x93CF 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x4219 000100 Cat0ID =0x7 020005 Title ="Thermactor Upstream Air Warm Start Delay #2" 020011 DescSize =0x7 020010 Desc ="UPSTM5" 020020 Units ="secs" 020100 Address =0x93D0 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x1D5C 000100 Cat0ID =0x7 020005 Title ="Thermactor Upstream WOT Time Delay" 020011 DescSize =0xF0 020010 Desc ="UPSWOT - If the time at WOT is less than this value then thermactor upstream air is permitted providing the 'Thermactor Upstream Air Max Time' (aka HMSTM) delay has not been exceeded. Set to zero to inhibit upstream air being added at WOT." 020020 Units ="secs" 020100 Address =0x93D3 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x5B3 000100 Cat0ID =0x7 020005 Title ="Throttle Body Air Flow" 020011 DescSize =0x2F6 020010 Desc ="ITHBMA - This parameter is the air mass flow through the throttle body when the butterfly is closed against the idle stop screw and the ISC dutycycle is 0%. This value is used by the eec to determine the ISC dutycycle required to meet the calculated desired idle air flow. Alter when the throttle body has been changed using this method;\r\n\r\nWith the engine fully warmed up and the idle steady, set the 'Disable ISC' (aka Z_ISCSW) parameter value to \"00\" and hopefully the car will still be idling. Adjust the throttle body stop screw so that the car will just barely idle and set the TPS to ~0.95 volts. Datalog the MAF's flow over a period of 30 seconds and calculate the average. Convert this kg/hr value into lb/min and use this value for this parameter." 020020 Units ="lb/min" 020050 SizeInBits =0x10 020100 Address =0x902E 020150 Flags =0x2 020200 Equation =X/4096,TH|0|0|0|0| 020210 DecimalPl =0x6 %%END%% %%CONSTANT%% 000002 UniqueID =0x5311 000100 Cat0ID =0x11 020005 Title ="Throttle Position Proportional Gain" 020011 DescSize =0x38 020010 Desc ="TAPGN - A multiplier of the relative throttle position." 020020 Units ="multiplier" 020050 SizeInBits =0x10 020100 Address =0x8E88 020150 Flags =0x2 020200 Equation =X/131072,TH|0|0|0|0| 020210 DecimalPl =0x6 %%END%% %%CONSTANT%% 000002 UniqueID =0x5818 000100 Cat0ID =0x1 020005 Title ="Time at High Load to Force O/L" 020011 DescSize =0x91 020010 Desc ="HLCTM - The time delay at high load before going to open loop. High load is determined by the 'Load% Min for O/L vs ECT' (aka FN320A) parameter." 020020 Units ="secs" 020100 Address =0x9AA0 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x573F 000100 Cat0ID =0x10 020005 Title ="Time Delay Before N/D or D/N Switch Registers" 020011 DescSize =0xA 020010 Desc ="NDDELT - " 020020 Units ="secs" 020100 Address =0x9068 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5DA1 000100 Cat0ID =0x9 020005 Title ="Time for IDM Bypass After PIP Recovery" 020011 DescSize =0x7 020010 Desc ="VIDMST" 020020 Units ="secs" 020100 Address =0x8ED0 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x27C9 000100 Cat0ID =0x9 020005 Title ="Time Out for IDM Fault" 020011 DescSize =0x7 020010 Desc ="VIDMTM" 020020 Units ="mSecs" 020050 SizeInBits =0x10 020100 Address =0x8ED2 020150 Flags =0x2 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x0 %%END%% %%CONSTANT%% 000002 UniqueID =0x155A 000100 Cat0ID =0x3 020005 Title ="TPS Average Closing Time Constant" 020011 DescSize =0x1B1 020010 Desc ="TCDASD - The time constant for the rolling average calculation of the 'TPS Average' (aka DSTPBR) value when the throttle is closing. The 'TPS Average' (aka DSTPBR) value is used in the calculation of the dashpot (pre position airflow) value.\r\n\r\nLarger time constant values increase the time lag of the value being updated but reduce unwanted transients from it. Smaller values reduce the dashpot prior to entry into dashpot control." 020020 Units ="secs" 020050 SizeInBits =0x10 020100 Address =0x97E2 020150 Flags =0x2 020200 Equation =X/1024,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5E6A 000100 Cat0ID =0x3 020005 Title ="TPS Average Opening Time Constant" 020011 DescSize =0x1B3 020010 Desc ="TCDASU - The time constant for the rolling average calculation of the 'TPS Average' (aka DSTPBR) value when the throttle is opening. The 'TPS Average' (aka DSTPBR) value is used in the calculation of the dashpot (pre position airflow) value.\r\n\r\nLarger time constant values increase the time lag of the value being updated but reduce unwanted transients from it. Smaller values result in quicker dashpot response to tip in/out actions." 020020 Units ="secs" 020050 SizeInBits =0x10 020100 Address =0x97E4 020150 Flags =0x2 020200 Equation =X/1024,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5542 000100 Cat0ID =0x1 020005 Title ="TPS Min Delta for Tip Out" 020011 DescSize =0x9F 020010 Desc ="TPDLTA - The minimum throttle position change required to indicate closing throttle movement. Value must be at least 0.1 volts to avoid A-D conversion jitter." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x9006 020150 Flags =0xE 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 020240 RangeHigh =5.1200 %%END%% %%CONSTANT%% 000002 UniqueID =0x4D89 000100 Cat0ID =0x9 020005 Title ="TPS KOEO Max" 020011 DescSize =0x60 020010 Desc ="VTAP2 - The KOEO test value at which the eec considers that the sensor has failed open circuit." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8EB8 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x18E7 000100 Cat0ID =0x9 020005 Title ="TPS KOEO Min" 020011 DescSize =0x61 020010 Desc ="VTAP1 - The KOEO test value at which the eec considers that the sensor has failed short circuit." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8EB6 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x6898 000100 Cat0ID =0x9 020005 Title ="TPS KOER Max" 020011 DescSize =0x60 020010 Desc ="VTAP4 - The KOER test value at which the eec considers that the sensor has failed open circuit." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8EBC 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x301F 000100 Cat0ID =0x9 020005 Title ="TPS KOER Min" 020011 DescSize =0x61 020010 Desc ="VTAP3 - The KOER test value at which the eec considers that the sensor has failed short circuit." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8EBA 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x3EAB 000100 Cat0ID =0x3 020005 Title ="TPS Knock Strategy Time Constant" 020011 DescSize =0xE5 020010 Desc ="TCTPT - The time constant for the rolling average calculation of the 'TPS Knock Strategy' (aka TBART) value.\r\n\r\nLarger time constant values increase the time lag of the value being updated but reduce unwanted transients from it." 020020 Units ="secs" 020050 SizeInBits =0x10 020100 Address =0x9806 020150 Flags =0x2 020200 Equation =X/1024,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x23E3 000100 Cat0ID =0x4 020005 Title ="TPS Max" 020011 DescSize =0x67 020010 Desc ="TAPMAX - The continuous test value at which the eec considers that the sensor has failed open circuit." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8EC8 020150 Flags =0xE 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 020240 RangeHigh =5.0000 %%END%% %%CONSTANT%% 000002 UniqueID =0x497F 000100 Cat0ID =0x9 020005 Title ="TPS Max for Output Test" 020011 DescSize =0x6 020010 Desc ="VTAP5" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8EBE 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x42E 000100 Cat0ID =0x4 020005 Title ="TPS Min" 020011 DescSize =0x68 020010 Desc ="TAPMIN - The continuous test value at which the eec considers that the sensor has failed short circuit." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8ECA 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x6B88 000100 Cat0ID =0x9 020005 Title ="TPS Min for Output Test" 020011 DescSize =0x6 020010 Desc ="VTAP6" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8EC0 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x42E3 000100 Cat0ID =0x3 020005 Title ="TPS O/L Threshold" 020011 DescSize =0xB0 020010 Desc ="THBP5 - The relative throttle position to force open loop.\r\n\r\nNB the relative throttle position is the actual throttle position value minus the closed throttle position value." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x9A92 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5446 000100 Cat0ID =0x11 020005 Title ="TPS Proportional Gain" 020011 DescSize =0x6 020010 Desc ="VTPGN" 020020 Units ="dutycycle/count" 020050 SizeInBits =0x10 020100 Address =0x8FB8 020150 Flags =0x2 020200 Equation =X/131072,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x7DB3 000100 Cat0ID =0x3 020005 Title ="TPS PT Threshold" 020011 DescSize =0x110 020010 Desc ="DELTA -The relative throttle position at which PT mode occurs. If altered, adjust 'Dashpot TP' (aka DELHYS) and 'ISC RPM Control TP' (aka DELRAT) to suit.\r\n\r\nNB the relative throttle position is the actual throttle position value minus the closed throttle position value." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x97AA 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x678F 000100 Cat0ID =0x3 020005 Title ="TPS PT Threshold Hysteresis" 020011 DescSize =0x9D 020010 Desc ="HYSTS - Hysteresis for 'TPS PT Threshold' (aka DELTA) parameter. If altered, adjust 'Dashpot TP' (aka DELHYS) and 'ISC RPM Control TP' (aka DELRAT) to suit." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x97AE 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x57D4 000100 Cat0ID =0x3 020005 Title ="TPS Time Constant" 020011 DescSize =0xD5 020010 Desc ="TCTP - The time constant for the rolling average calculation of the 'TPS' (aka TPBAR) value.\r\n\r\nLarger time constant values increase the time lag of the value being updated but reduce unwanted transients from it." 020020 Units ="secs" 020050 SizeInBits =0x10 020100 Address =0x97F6 020150 Flags =0x2 020200 Equation =X/1024,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x791A 000100 Cat0ID =0x3 020005 Title ="TPS WOT Threshold" 020011 DescSize =0xB6 020010 Desc ="THBP2 - The relative throttle position at which WOT mode occurs.\r\n\r\nNB the relative throttle position is the actual throttle position value minus the closed throttle position value." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x97B0 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x2BCC 000100 Cat0ID =0x3 020005 Title ="TPS WOT Threshold Hysteresis" 020011 DescSize =0x6 020010 Desc ="HYST2" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x97AC 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x55A5 000100 Cat0ID =0x12 020005 Title ="Transient Fuel Acceleration Multiplier" 020011 DescSize =0xA5 020010 Desc ="MEFTRA - Multiplier of the transient fuel contribution to the injection pulsewidth.\r\nMultiplier values less than 1 reduce fuel, values greater than 1 increase fuel." 020020 Units ="multiplier" 020100 Address =0x9014 020200 Equation =X/128,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5572 000100 Cat0ID =0x12 020005 Title ="Transient Fuel Compensation Start Delay" 020011 DescSize =0x5A 020010 Desc ="TFCTM - Time delay from exiting cranking before transient fuel compensation is permitted." 020020 Units ="secs" 020100 Address =0x9010 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x55A7 000100 Cat0ID =0x12 020005 Title ="Transient Fuel Deadband" 020011 DescSize =0xA 020010 Desc ="TFCDED - " 020020 Units ="%" 020050 SizeInBits =0x10 020100 Address =0x9016 020150 Flags =0x2 020200 Equation =X/2.56,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x55A6 000100 Cat0ID =0x12 020005 Title ="Transient Fuel Deceleration Multiplier" 020011 DescSize =0xA5 020010 Desc ="MEFTRD - Multiplier of the transient fuel contribution to the injection pulsewidth.\r\nMultiplier values less than 1 reduce fuel, values greater than 1 increase fuel." 020020 Units ="multiplier" 020100 Address =0x9015 020200 Equation =X/128,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5571 000100 Cat0ID =0x12 020005 Title ="Transient Fuel Max RPM Deadband" 020011 DescSize =0x5F 020010 Desc ="TFSMN - The maximum rpm deadband above idle rpm to disable transient fuel during dashpot mode." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x900E 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x5570 000100 Cat0ID =0x12 020005 Title ="Transient Fuel Multiplier" 020011 DescSize =0x8E 020010 Desc ="KFT - A global multiplier used in the calculation of the 'Equilbrium Fuel Transfer Rate'. Set to zero to disable transient fuel compensation." 020020 Units ="multiplier" 020100 Address =0x900C 020200 Equation =X/128,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x6EFF 000100 Cat0ID =0x2 020005 Title ="Transient Spark Flag Hi Lo Changes" 020011 DescSize =0x7 020010 Desc ="DFMIN0" 020020 Units ="no." 020100 Address =0x9E6E 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x33FC 000100 Cat0ID =0x2 020005 Title ="Transient Spark Flag Lo Hi Changes" 020011 DescSize =0x7 020010 Desc ="DFMIN1" 020020 Units ="no." 020100 Address =0x9E6F 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x5888 000100 Cat0ID =0x2 020005 Title ="Transient Spark Min RPM" 020011 DescSize =0x4D 020010 Desc ="TRSRPM - The minimum rpm required to enable the transient spark calculation." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x9E6A 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x5D45 000100 Cat0ID =0x2 020005 Title ="Transient Spark Min RPM Hysteresis" 020011 DescSize =0x42 020010 Desc ="TRSRPH - Hysyteresis for the 'Transient Spark Min RPM' parameter." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x9E6C 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x21AC 000100 Cat0ID =0x10 020005 Title ="Transmission Strategy" 020011 DescSize =0x10A 020010 Desc ="TSTRAT - Selects which transmission strategy to use;\r\n0 = no transmission control\r\n1 = SIL (shift indicator light)\r\n2 = A4LD with 3/4 shift control and convertor clutch control\r\n3 = AXOD\r\n4 = C6E4 (E4OD)\r\n5 = A4LD-E\r\n6 = FAX-4\r\n7 = AOD-4 (AOD-I)\r\n8 = 4EAT\r\n9 = CD4E" 020020 Units ="" 020100 Address =0x9E5D 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x6268 000100 Cat0ID =0x10 020005 Title ="Transmission Type" 020011 DescSize =0x149 020010 Desc ="TRLOAD -\r\n0 = manual, no clutch or gear switches, forced neutral state\r\n1 = manual, no clutch or gear switches\r\n2 = manual, one clutch or gear switch\r\n3 = manual, both clutch and gear switches\r\n4 = auto, non electronic, neutral drive switch\r\n5 = auto, non electronic, neutral pressure switch\r\n6 = auto, electronic, PRNDL sensor" 020020 Units ="" 020100 Address =0x9E5C 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x1811 000100 Cat0ID =0x5 020005 Title ="Underspeed RPM" 020011 DescSize =0x38 020010 Desc ="UNRPM - The rpm below which the UNDERSPEED_FLAG is set." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x97BE 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x51E3 000100 Cat0ID =0x5 020005 Title ="Underspeed RPM Hysteresis" 020011 DescSize =0x3A 020010 Desc ="UNRPMH - The hysteresis value for 'Underspeed RPM' value." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x97C0 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x29F2 000100 Cat0ID =0x5 020005 Title ="Unmeasured Air" 020011 DescSize =0x63 020010 Desc ="ARCHLK - Air entering the engine that hasn't been measured by the MAF sensor, e.g. EGR, CANP, PCV." 020020 Units ="lb/min" 020050 SizeInBits =0x10 020100 Address =0x9018 020150 Flags =0x2 020200 Equation =X/2048,TH|0|0|0|0| 020210 DecimalPl =0x6 %%END%% %%CONSTANT%% 000002 UniqueID =0x5316 000100 Cat0ID =0x11 020005 Title ="Vehicle Speed Control Deadband" 020011 DescSize =0x72 020010 Desc ="MPHDED - If actual mph is less than desired speed minus this value then vehicle speed control should be disabled." 020020 Units ="mph" 020050 SizeInBits =0x10 020100 Address =0x8E92 020150 Flags =0x2 020200 Equation =X/512,TH|0|0|0|0| 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x5314 000100 Cat0ID =0x11 020005 Title ="Vehicle Speed Control Disable MPH" 020011 DescSize =0x42 020010 Desc ="MAXVSP - The speed above which vehicle speed control is disabled." 020020 Units ="mph" 020050 SizeInBits =0x10 020100 Address =0x8E8E 020150 Flags =0x2 020200 Equation =X/512,TH|0|0|0|0| 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x5315 000100 Cat0ID =0x11 020005 Title ="Vehicle Speed Control Disable RPM" 020011 DescSize =0x40 020010 Desc ="VSNMAX - The rpm above which vehicle speed control is disabled." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x8E90 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x5344 000100 Cat0ID =0x11 020005 Title ="Vehicle Speed Control Dutycycle Offset" 020011 DescSize =0x7 020010 Desc ="HLDREF" 020020 Units ="%" 020050 SizeInBits =0x10 020100 Address =0x8E9A 020150 Flags =0x2 020200 Equation =X/128,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x5313 000100 Cat0ID =0x11 020005 Title ="Vehicle Speed Control Enable MPH" 020011 DescSize =0x3A 020010 Desc ="MINVSP - The minimum mph to enable vehicle speed control." 020020 Units ="mph" 020050 SizeInBits =0x10 020100 Address =0x8E8C 020150 Flags =0x2 020200 Equation =X/512,TH|0|0|0|0| 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x5341 000100 Cat0ID =0x11 020005 Title ="Vehicle Speed Control Enable MPH Hysteresis" 020011 DescSize =0x5 020010 Desc ="MPHH" 020020 Units ="mph" 020050 SizeInBits =0x10 020100 Address =0x8E94 020150 Flags =0x2 020200 Equation =X/512,TH|0|0|0|0| 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x6259 000100 Cat0ID =0x9 020005 Title ="Vehicle Speed Dutycycle Bias" 020011 DescSize =0x7 020010 Desc ="VDCBIA" 020020 Units ="%" 020050 SizeInBits =0x10 020100 Address =0x8FCA 020150 Flags =0x2 020200 Equation =X/128,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x5310 000100 Cat0ID =0x11 020005 Title ="Vehicle Speed Proportional Gain" 020011 DescSize =0x4F 020010 Desc ="VEHGN - Multiplier of vehicle speed used in the vehicle speed control routine." 020020 Units ="multiplier" 020050 SizeInBits =0x10 020100 Address =0x8E86 020150 Flags =0x2 020200 Equation =X/16384,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5471 000100 Cat0ID =0x9 020005 Title ="Vehicle Speed Ramp Rate" 020011 DescSize =0x6 020010 Desc ="VACRR" 020020 Units ="mph/sec" 020050 SizeInBits =0x10 020100 Address =0x8FBE 020150 Flags =0x2 020200 Equation =X/512,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x5F90 000100 Cat0ID =0x9 020005 Title ="VISDL2" 020011 DescSize =0x32 020010 Desc ="VISDL2\r\n\r\nDoes not appear to be used in this ecu." 020020 Units ="secs" 020100 Address =0x9E89 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x3B3D 000100 Cat0ID =0x5 020005 Title ="Voltage Calibration Constant" 020011 DescSize =0x2A 020010 Desc ="VCAL - Used to calculate battery voltage." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x9A8A 020150 Flags =0x2 020200 Equation =X/4096,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x1D9D 000100 Cat0ID =0x9 020005 Title ="VSC Speed Decrease Test Time" 020011 DescSize =0x6 020010 Desc ="VIPT4" 020020 Units ="secs" 020100 Address =0x980C 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x6D9D 000100 Cat0ID =0x9 020005 Title ="VSC Speed Post Ramp Test Time Delay" 020011 DescSize =0x7 020010 Desc ="VDLY11" 020020 Units ="secs" 020100 Address =0x8FC4 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x4A1A 000100 Cat0ID =0x9 020005 Title ="VSC Speed Ramp Test Time Delay" 020011 DescSize =0x7 020010 Desc ="VDLY10" 020020 Units ="secs" 020100 Address =0x8FC3 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x76B4 000100 Cat0ID =0x9 020005 Title ="VSC Static Test Max Time" 020011 DescSize =0x6 020010 Desc ="VIPT1" 020020 Units ="secs" 020100 Address =0x8FC0 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x1181 000100 Cat0ID =0x9 020005 Title ="VSC Test Max Ramp Time" 020011 DescSize =0x6 020010 Desc ="VIPT2" 020020 Units ="secs" 020100 Address =0x8FC1 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x1D9B 000100 Cat0ID =0x9 020005 Title ="VSC Test Max Time" 020011 DescSize =0x4F 020010 Desc ="VVSCET - The maximum time allowed since power up for the test to be permitted." 020020 Units ="secs" 020100 Address =0x8FCC 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x7AF6 000100 Cat0ID =0x9 020005 Title ="VSC Test MPH" 020011 DescSize =0x48 020010 Desc ="VMLO - The maximum vehicle speed in order for the test to be permitted." 020020 Units ="mph" 020050 SizeInBits =0x10 020100 Address =0x980A 020150 Flags =0x2 020200 Equation =X/512,TH|0|0|0|0| 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x15FA 000100 Cat0ID =0x9 020005 Title ="VSC Test Set Speed" 020011 DescSize =0x5 020010 Desc ="VRSS" 020020 Units ="mph" 020050 SizeInBits =0x10 020100 Address =0x8FBC 020150 Flags =0x2 020200 Equation =X/512,TH|0|0|0|0| 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x2322 000100 Cat0ID =0x9 020005 Title ="VSC Test Set Speed Hysteresis" 020011 DescSize =0x5 020010 Desc ="VRSH" 020020 Units ="mph" 020050 SizeInBits =0x10 020100 Address =0x8FBA 020150 Flags =0x2 020200 Equation =X/512,TH|0|0|0|0| 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x761D 000100 Cat0ID =0x9 020005 Title ="VSC Test TP Min Change" 020011 DescSize =0x6 020010 Desc ="VTPLD" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8FC6 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x3730 000100 Cat0ID =0x9 020005 Title ="VSC Test TP Max Change" 020011 DescSize =0x6 020010 Desc ="VTPLU" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8FC8 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x52B1 000100 Cat0ID =0x11 020005 Title ="VSCCS Min Change" 020011 DescSize =0xB7 020010 Desc ="DEBAMP - The minimum change in voltage of the Vehicle Speed Control Command Switch for the 'Debounce Timer' (aka DEBTMR) to be reset to the 'Debounce Time Delay' (aka DEBTIM) value. " 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8E6C 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x77A9 000100 Cat0ID =0x11 020005 Title ="VSS Error Deadband" 020011 DescSize =0x48 020010 Desc ="HLDRNG - VSC dutycycle error deadband for which no pulses are required." 020020 Units ="%" 020100 Address =0x8E9E 020200 Equation =X/128,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x39DB 000100 Cat0ID =0x7 020005 Title ="VSS Frequency" 020011 DescSize =0x7 020010 Desc ="VSCFRQ" 020020 Units ="Hz" 020100 Address =0x8EA0 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x2B5D 000100 Cat0ID =0x9 020005 Title ="VSS Test Decel MAP Max" 020011 DescSize =0x1E 020010 Desc ="VSMAPL - Manual gearbox only." 020020 Units ="in Hg" 020100 Address =0x8FCD 020200 Equation =X/8,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x5216 000100 Cat0ID =0x9 020005 Title ="VSS Test Min MPH" 020011 DescSize =0x7 020010 Desc ="VSSMN1" 020020 Units ="mph" 020100 Address =0x8FD2 020200 Equation =X/2,TH|0|0|0|0| 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x4DDF 000100 Cat0ID =0x9 020005 Title ="VSS Test Min Time" 020011 DescSize =0x45 020010 Desc ="VSSTIM - The minimum time required before the VSS test can continue." 020020 Units ="secs" 020100 Address =0x8FD4 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x4911 000100 Cat0ID =0x9 020005 Title ="VSS Test Min RPM Auto Gearbox" 020011 DescSize =0xA 020010 Desc ="VSAMIN - " 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x8FCE 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x339F 000100 Cat0ID =0x9 020005 Title ="VSS Test Min RPM Manual Gearbox" 020011 DescSize =0xA 020010 Desc ="VSMMIN - " 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x8FD0 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x7F75 000100 Cat0ID =0x1 020005 Title ="Warm HEGO Flag Cold Start Delay #1" 020011 DescSize =0x130 020010 Desc ="OPCLT1 - When the ECT at start is less than the 'Cold Start Max ECT' value this is the minimum time that must pass since exiting crank in order for the WARM_EGO_FLAG to be set.\r\n\r\nNote: the 'HEGO Min Switches Before Warm' (aka EGOCL1) and 'Warm HEGO Flag Cold Start Delay #2' values also need exceeding." 020020 Units ="secs" 020100 Address =0x9A8F 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x2B7D 000100 Cat0ID =0x1 020005 Title ="Warm HEGO Flag Cold Start Delay #2" 020011 DescSize =0x14E 020010 Desc ="OPCLT4 - When the ECTat start is less than the 'Cold Start Max ECT' value this is the minimum time that must pass since the ECT exceeded the 'Engine Warm ECT' value in order for the WARM_EGO_FLAG to be set.\r\n\r\nNote: the 'HEGO Min Switches Before Warm' (aka EGOCL1) and 'Warm HEGO Flag Cold Start Delay #1' values also need exceeding." 020020 Units ="secs" 020100 Address =0x9A90 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x6872 000100 Cat0ID =0x1 000101 Cat1ID =0xB 020005 Title ="Warm HEGO Flag Hot Start Delay" 020011 DescSize =0x162 020010 Desc ="OPCLT3 - When the ECT at start is greater than the 'Hot Start Min ECT' value this is the minimum time that must pass since exiting crank in order for the WARM_EGO_FLAG to be set.\r\n\r\nNote: the 'HEGO Min Switches Before Warm' (aka EGOCL1) value also needs exceeding.\r\n\r\nThis parameter is also used during failure management when the ECT sensor has failed." 020020 Units ="secs" 020100 Address =0x9A8C 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x4B61 000100 Cat0ID =0x1 000101 Cat1ID =0xB 020005 Title ="Warm HEGO Flag Warm Start Delay #1" 020011 DescSize =0x1A0 020010 Desc ="OPCLT2 - When the ECT at start is between the 'Cold Start Max ECT' and 'Hot Start Min ECT' values this is the minimum time that must pass since exiting crank in order for the WARM_EGO_FLAG to be set.\r\n\r\nNote: the 'HEGO Min Switches Before Warm' (aka EGOCL1) and 'Warm HEGO Flag Warm Start Delay #2' values also need exceeding.\r\n\r\nThis parameter is also used during failure management when the ECT sensor has failed." 020020 Units ="secs" 020100 Address =0x9A8D 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x1166 000100 Cat0ID =0x1 020005 Title ="Warm HEGO Flag Warm Start Delay #2" 020011 DescSize =0x166 020010 Desc ="OPCLT5 - When the ECT at start is between the 'Cold Start Max ECT' and 'Hot Start Min ECT' values this is the minimum time that must pass since the ECT exceeded the 'Engine Warm ECT' value in order for the WARM_EGO_FLAG to be set.\r\n\r\nNote: the 'HEGO Min Switches Before Warm' (aka EGOCL1) and 'Warm HEGO Flag Warm Start Delay #1' values also need exceeding." 020020 Units ="secs" 020100 Address =0x9A8E 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x42FA 000100 Cat0ID =0x9 020005 Title ="Wiggle Test Upcount Threshold" 020011 DescSize =0x7 020010 Desc ="WIGLVL" 020020 Units ="" 020100 Address =0x8ECC 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x5CD2 000100 Cat0ID =0x2 020005 Title ="WOT Spark Adder" 020011 DescSize =0x5 020010 Desc ="KWS1" 020020 Units ="deg adv" 020050 SizeInBits =0x10 020100 Address =0x943A 020150 Flags =0x3 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x43E4 000100 Cat0ID =0x2 020005 Title ="WOT Spark Elimination" 020011 DescSize =0x2CE 020010 Desc ="Z_WSPKSW - This is normally set to \"D030\", change to \"4920\" to use the part throttle spark parameters instead of the WOT spark parameters when at WOT.\r\n\r\nWARNING: Do not use any values other than these OR attempt to make this change whilst emulating.\r\n\r\nOptionable: Next use the Hex Editor (ctrl + H) to fill the addresses from 0x56A3 to 0x56EB with \"FF\". WARNING: These changes are non reversable.\r\n\r\nThe following parameters are now ineffective and any alterations made to them will not have any effect on the spark timing;\r\n\r\n'WOT Spark Adder' (aka KWS1) \r\n'WOT Spark Advance vs ACT' (aka FN135)\r\n'WOT Spark Advance vs BP' (aka FN133)\r\n'WOT Spark Advance vs ECT' (aka FN134)\r\n'WOT Spark Advance vs RPM' (aka FN131)" 020020 Units ="" 020050 SizeInBits =0x10 020100 Address =0x56A1 020150 Flags =0x2 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x3 020210 DecimalPl =0x1 %%END%% %%TABLE%% 000002 UniqueID =0x64CB 000100 Cat0ID =0x7 040005 Title ="Injector Output Port" 040011 DescSize =0x113 040010 Desc ="FN1327 - Links the injector to a calculated fuel pulsewidth.\r\n\r\n1 = use Fuel Pulsewidth #1\r\n2 = use Fuel Pulsewidth #2.\r\n\r\nNote: If the 'Number of HEGOs' (aka NUMEGO) parameter = 1 then set all entries to 1 or cylinder bank 2 will receive no fuel. Only use values of 1 or 2." 040100 Address =0x91B1 040200 ZEq =X/2+1,TH|0|0|0|0| 040203 XOutType =0x4 040304 YOutType =0x4 040205 OutType =0x2 040210 DecimalPl =0x1 040230 RangeLow =0.0000 040240 RangeHigh =10.0000 040300 Rows =0x1 040305 Cols =0x8 040320 XUnits ="Injector Port" 040325 YUnits ="n/a" 040330 ZUnits ="no." 040350 XLabels =1,2,3,4,5,6,7,8 040352 XLabelType =0x4 040354 XEq =X,TH|0|0|0|0| 040360 YLabels =Port 040362 YLabelType =0x4 040364 YEq =X,TH|0|0|0|0| 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x6499 000100 Cat0ID =0x7 040005 Title ="Injector Timing" 040011 DescSize =0x278 040010 Desc ="FN1315 - Defines the injector firing timing point from TDC. Can indicate the start or end timing point of the injector pulse depending on the setting of the 'Injector Timing Edge' (aka INJREF) parameter. The result from is table lookup is modified by the 'Injector Timing Multiplier' (aka IDKMUL) and 'Injector Timing Delay' (aka IDKADD) parameters.\r\n\r\nIf the appropriate conditions are met then a fixed injector timing value may alternatively be provided by one of the following parameters;\r\n\r\n'Injector Timing Value at Idle' (aka MIDTV)\r\n'Injector Timing Value for MFA' (aka MINTV)\r\n'Injector Timing Value in Neutral' (aka CINTV)" 040100 Address =0x9160 040200 ZEq =X*4,TH|0|0|0|0| 040203 XOutType =0x4 040304 YOutType =0x4 040205 OutType =0x2 040210 DecimalPl =0x1 040230 RangeLow =0.0000 040240 RangeHigh =1000.0000 040300 Rows =0x8 040305 Cols =0xA 040320 XUnits ="rpm" 040325 YUnits ="load" 040330 ZUnits ="crank deg" 040350 XLabels = 500, 700, 900, 1100, 1300, 1500, 2000, 2500, 3000, 4000 040352 XLabelType =0x4 040354 XEq =X,TH|0|0|0|0| 040360 YLabels =0.05,0.10,0.20,0.30,0.40,0.50,0.60,0.75 040362 YLabelType =0x4 040364 YEq =X,TH|0|0|0|0| 040500 XLabelLink =0x7CE5 040505 XLabelSource =0x2 040510 YLabelLink =0xDA3 040515 YLabelSource =0x2 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0xDA3 000100 Cat0ID =0x8 000101 Cat1ID =0xFF 040005 Title ="Injector Timing Scaler for Load" 040011 DescSize =0x7B 040010 Desc ="FN085 - Do not edit first or last entries. Provides row scaling for the following table;\r\n\r\n'Injector Timing' (aka FN1315)" 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x300 040200 ZEq =X,TH|0|0|0|0| 040304 YOutType =0x2 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x6 040305 Cols =0x1 040320 XUnits ="load" 040325 YUnits ="row" 040330 ZUnits ="" 040350 XLabels =Load,Table Row Index 040352 XLabelType =0x4 040354 XEq =X/327.68,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/16,TH|0|0|0|0| 040600 XAddress =0x9148 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x914A 040750 YOutputDig =0x1 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x1655 000100 Cat0ID =0x6 000101 Cat1ID =0xFF 040005 Title ="ISC Adder vs RPM" 040011 DescSize =0xFC 040010 Desc ="FN810 - An adder used in the calculation of the desired ISC valve airflow to correct for dips in the idle rpm. If the base target idle speed values have been altered then adjust the input rpm in rows 2, 3 and 4 to suit. Do not edit first or last rows." 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x300 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x5 040305 Cols =0x1 040320 XUnits ="rpm" 040325 YUnits ="lb/min" 040330 ZUnits ="" 040350 XLabels =Speed 040352 XLabelType =0x4 040354 XEq =X/4,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/4096,TH|0|0|0|0| 040600 XAddress =0x9286 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x9288 040750 YOutputDig =0x3 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x648E 000100 Cat0ID =0x6 000101 Cat1ID =0xFF 040005 Title ="ISC C/L RPM Correction Rate" 040011 DescSize =0x6 040010 Desc ="FN860" 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x340 040200 ZEq =X,TH|0|0|0|0| 040304 YOutType =0x2 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x7 040305 Cols =0x1 040320 XUnits ="rpm" 040325 YUnits ="rate" 040330 ZUnits ="" 040350 XLabels = 040352 XLabelType =0x4 040354 XEq =X/4,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X,TH|0|0|0|0| 040600 XAddress =0x930E 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x9310 040750 YOutputDig =0x1 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x7454 000100 Cat0ID =0x6 000101 Cat1ID =0xFF 040005 Title ="ISC Dutycycle During Crank" 040011 DescSize =0x6 040010 Desc ="FN884" 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x40 040200 ZEq =X,TH|0|0|0|0| 040203 XOutType =0x2 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x6 040305 Cols =0x1 040320 XUnits ="deg F at start" 040325 YUnits ="dutycycle" 040330 ZUnits ="" 040350 XLabels = 040352 XLabelType =0x4 040354 XEq =X*2,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/1.28,TH|0|0|0|0| 040600 XAddress =0x935A 040610 XDataSize =0x1 040620 XAddrStep =-2 040650 XOutputDig =0x1 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x935B 040710 YDataSize =0x1 040720 YAddrStep =-2 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0xCB5 000100 Cat0ID =0x6 000101 Cat1ID =0xFF 040005 Title ="ISC Dutycycle Multiplier vs Load" 040011 DescSize =0xBB 040010 Desc ="FN820B - Used to compensate for the increase in airflow through the ISC valve during high manifold vacuum compared to normal idle vacuum levels, e.g. during closed throttle deceleration." 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x300 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x6 040305 Cols =0x1 040320 XUnits ="load" 040325 YUnits ="multiplier" 040330 ZUnits ="" 040350 XLabels =Time in Crank Mode,Crank Fuel Multiplier 040352 XLabelType =0x4 040354 XEq =X/327.68,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/128,TH|0|0|0|0| 040600 XAddress =0x929A 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x929C 040750 YOutputDig =0x3 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x54D3 000100 Cat0ID =0x6 000101 Cat1ID =0xFF 040005 Title ="ISC Gain vs RPM Error" 040011 DescSize =0x289 040010 Desc ="FN824 - A multplier of the following parameters, used as input in IPSIBR calculation for proportion correction of idle rpm when in closed loop rpm control. The input rpm at rows 4 and 5 should typically be set to 16 rpm lower and higher respectively than the base target idle speed value. The input rpm at rows 3 and 6 should typically be set to approximately 200 rpm lower and higher respectively than the base target idle speed value. Do not edit the first or last rows.\r\n\r\nISC Gain For Overspeed in Drive (to be confirmed)\r\nISC Gain For Overspeed in Neutral\r\nISC Gain For Underspeed in Drive (to be confirmed)\r\nISC Gain For Underspeed in Neutral" 040020 SubType =0x7 040100 Address =0x0 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x7 040305 Cols =0x1 040320 XUnits ="rpm" 040325 YUnits ="gain" 040330 ZUnits ="" 040350 XLabels = 040352 XLabelType =0x4 040354 XEq =X*16,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/64,TH|0|0|0|0| 040600 XAddress =0x92B2 040610 XDataSize =0x1 040620 XAddrStep =-2 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x92B3 040710 YDataSize =0x1 040720 YAddrStep =-2 040750 YOutputDig =0x3 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0xE7D 000100 Cat0ID =0x8 000101 Cat1ID =0xFF 040005 Title ="ISC Startup Scaler for ECT" 040011 DescSize =0x7D 040010 Desc ="FN020C - Do not edit first or last entries. Provides column scaling for the following table;\r\n\r\n'Desired Airflow Multiplier'" 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x40 040200 ZEq =X,TH|0|0|0|0| 040203 XOutType =0x2 040304 YOutType =0x2 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x5 040305 Cols =0x1 040320 XUnits ="deg F" 040325 YUnits ="column" 040330 ZUnits ="" 040350 XLabels =ECT,Table Index 040352 XLabelType =0x4 040354 XEq =X*2,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/16,TH|0|0|0|0| 040600 XAddress =0x924C 040610 XDataSize =0x1 040620 XAddrStep =-2 040650 XOutputDig =0x1 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x924D 040710 YDataSize =0x1 040720 YAddrStep =-2 040750 YOutputDig =0x1 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x10B5 000100 Cat0ID =0x8 000101 Cat1ID =0xFF 040005 Title ="ISC Time Scaler for Time" 040011 DescSize =0x7B 040010 Desc ="FN018B - Do not edit first or last entries. Provides row scaling for the following table;\r\n\r\n'Desired Airflow Multiplier'" 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x300 040200 ZEq =X,TH|0|0|0|0| 040203 XOutType =0x2 040304 YOutType =0x2 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x5 040305 Cols =0x1 040320 XUnits ="secs" 040325 YUnits ="column" 040330 ZUnits ="" 040350 XLabels =Table Index 040352 XLabelType =0x4 040354 XEq =X,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/256,TH|0|0|0|0| 040600 XAddress =0x9AFC 040650 XOutputDig =0x1 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x9AFE 040750 YOutputDig =0x1 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x2142 000100 Cat0ID =0x6 000101 Cat1ID =0xFF 040005 Title ="ISC Transfer" 040011 DescSize =0x4F 040010 Desc ="FN800 - Alter if air flow characteristics through the ISC valve have changed." 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x300 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0xC 040305 Cols =0x1 040320 XUnits ="lb/min" 040325 YUnits ="dutycycle" 040330 ZUnits ="" 040350 XLabels = 040352 XLabelType =0x4 040354 XEq =X/4096,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/327.68,TH|0|0|0|0| 040600 XAddress =0x9256 040650 XOutputDig =0x3 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x9258 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0xE68 000100 Cat0ID =0x2 000101 Cat1ID =0xFF 040005 Title ="Knock Advance Rate vs RPM" 040011 DescSize =0x1D6 040010 Desc ="FN146B - This limits the rate at which the spark returns to the calculated spark advance following retardation due to knock control in order to avoid pinging. This value is the number of milliseconds that must pass since the last spark increment before the next increment is allowed to occur. Decrease to improve throttle response. When allowed, the spark is advanced a 1/4 of a degree each time at a maximum rate of a 1/4 quarter of a degree between each firing event." 040020 SubType =0x7 040100 Address =0x0 040200 ZEq =X,TH|0|0|0|0| 040203 XOutType =0x2 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x6 040305 Cols =0x1 040320 XUnits ="rpm" 040325 YUnits ="mSecs" 040330 ZUnits ="" 040350 XLabels =RPM,Seconds/Degree 040352 XLabelType =0x4 040354 XEq =X/4*128,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/16,TH|0|0|0|0| 040600 XAddress =0x979C 040610 XDataSize =0x1 040620 XAddrStep =-2 040650 XOutputDig =0x1 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x979D 040710 YDataSize =0x1 040720 YAddrStep =-2 040750 YOutputDig =0x3 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x6C27 000100 Cat0ID =0x2 000101 Cat1ID =0xFF 040005 Title ="Knock Retard Increment vs RPM" 040011 DescSize =0x7 040010 Desc ="FN143A" 040020 SubType =0x7 040100 Address =0x0 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x6 040305 Cols =0x1 040320 XUnits ="rpm" 040325 YUnits ="sec/degrees" 040330 ZUnits ="" 040350 XLabels =Speed,Y 040352 XLabelType =0x4 040354 XEq =X/4*128,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/4,TH|0|0|0|0| 040600 XAddress =0x9778 040610 XDataSize =0x1 040620 XAddrStep =-2 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x9779 040710 YDataSize =0x1 040720 YAddrStep =-2 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x4DFC 000100 Cat0ID =0x2 000101 Cat1ID =0xFF 040005 Title ="Knock Threshold Window Time" 040011 DescSize =0xA 040010 Desc ="FN144A - " 040020 SubType =0x7 040100 Address =0x0 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x7 040305 Cols =0x1 040320 XUnits ="rpm" 040325 YUnits ="PIP period fraction" 040330 ZUnits ="" 040350 XLabels =Speed,Y 040352 XLabelType =0x4 040354 XEq =X*32,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/1024,TH|0|0|0|0| 040600 XAddress =0x9784 040610 XDataSize =0x1 040620 XAddrStep =-2 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x9785 040710 YDataSize =0x1 040720 YAddrStep =-2 040750 YOutputDig =0x3 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x2B30 000100 Cat0ID =0x2 000101 Cat1ID =0xFF 040005 Title ="Knock Threshold Window Position" 040011 DescSize =0x72 040010 Desc ="FN145A - The result of this lookup is added to the 'Knock Threshold Window Position Delay' (aka WOPEN) parameter." 040020 SubType =0x7 040100 Address =0x0 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x5 040305 Cols =0x1 040320 XUnits ="rpm" 040325 YUnits ="PIP period fraction" 040330 ZUnits ="" 040350 XLabels =Speed 040352 XLabelType =0x4 040354 XEq =X/4*128,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/256,TH|0|0|0|0| 040600 XAddress =0x9792 040610 XDataSize =0x1 040620 XAddrStep =-2 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x9793 040710 YDataSize =0x1 040720 YAddrStep =-2 040750 YOutputDig =0x6 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0xBE5 000100 Cat0ID =0x1 000101 Cat1ID =0xFF 040005 Title ="Load% Min for O/L vs ECT" 040011 DescSize =0x17B 040010 Desc ="FN320A - Use to set the minimum load% required to permit entry into open loop operation according to ECT.\r\n\r\nWhen the result of this table's lookup is less than LOAD% then the 'Inhibit High Load Timer Flag' is set. If the 'Inhibit High Load Timer Flag' is clear then open loop mode is entered after the 'Time at High Load to Force O/L' (aka HLCTM) time period has been exceeded." 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x340 040200 ZEq =X,TH|0|0|0|0| 040203 XOutType =0x2 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x7 040305 Cols =0x1 040320 XUnits ="deg F" 040325 YUnits ="load%" 040330 ZUnits ="" 040350 XLabels =ECT 040352 XLabelType =0x4 040354 XEq =X*2,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/327.68,TH|0|0|0|0| 040600 XAddress =0x9CAC 040650 XOutputDig =0x1 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x9CAE 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x461 000100 Cat0ID =0x2 000101 Cat1ID =0xFF 040005 Title ="LOM Table" 040011 DescSize =0x65 040010 Desc ="FN125 - Used to determine if the more aggressive 'Spark Base Table' (aka FN901) table is to be used." 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x300 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x5 040305 Cols =0x1 040320 XUnits ="rpm" 040325 YUnits ="load" 040330 ZUnits ="" 040350 XLabels =Speed 040352 XLabelType =0x4 040354 XEq =X/4,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/327.68,TH|0|0|0|0| 040600 XAddress =0x94DA 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x94DC 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x429B 000100 Cat0ID =0x3 040005 Title ="MAF Backflow Correction" 040011 DescSize =0x52 040010 Desc ="FN1035 - Multiplier of raw air mass to compensate for backflow in the MAF sensor." 040100 Address =0x9BA0 040200 ZEq =X/128,TH|0|0|0|0| 040203 XOutType =0x4 040304 YOutType =0x4 040210 DecimalPl =0x3 040230 RangeLow =8.0000 040240 RangeHigh =18.0000 040300 Rows =0x8 040305 Cols =0xA 040320 XUnits ="rpm" 040325 YUnits ="load" 040330 ZUnits ="A/F Ratio" 040350 XLabels = 500, 700, 900, 1100, 1300, 1500, 2000, 2500, 3000, 4000 040352 XLabelType =0x4 040354 XEq =X,TH|0|0|0|0| 040360 YLabels =0.050,0.100,0.200,0.300,0.400,0.500,0.600,0.750 040362 YLabelType =0x4 040364 YEq =X,TH|0|0|0|0| 040500 XLabelLink =0x7CE5 040505 XLabelSource =0x2 040510 YLabelLink =0x5130 040515 YLabelSource =0x2 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x2748 000100 Cat0ID =0x3 000101 Cat1ID =0xFF 040005 Title ="MAF Transfer" 040011 DescSize =0x3A 040010 Desc ="FN036 - Output is shown in kg/hr (converted from lb/tick)" 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x300 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x1E 040305 Cols =0x1 040320 XUnits ="volts" 040325 YUnits ="kg/hr" 040330 ZUnits ="" 040350 XLabels =MAF Voltage,Mass Flow 040352 XLabelType =0x4 040354 XEq =X/4096,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/3.1562283 ,TH|0|0|0|0| 040600 XAddress =0x8DE2 040650 XOutputDig =0x3 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x8DE4 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0xFEA 000100 Cat0ID =0xF 000101 Cat1ID =0xFF 040005 Title ="MFA Altitude Multiplier vs BP" 040011 DescSize =0x3F 040010 Desc ="FN311 - Also used in part throttle spark and EGR calculations." 040020 SubType =0x7 040100 Address =0x0 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x6 040305 Cols =0x1 040320 XUnits ="in Hg" 040325 YUnits ="multiplier" 040330 ZUnits ="" 040350 XLabels =Barometric Pressure 040352 XLabelType =0x4 040354 XEq =X/8,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/128,TH|0|0|0|0| 040600 XAddress =0x90B9 040610 XDataSize =0x1 040620 XAddrStep =-2 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x90BA 040710 YDataSize =0x1 040720 YAddrStep =-2 040750 YOutputDig =0x3 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x2D8C 000100 Cat0ID =0x8 000101 Cat1ID =0xFF 040005 Title ="MFA EGR and PT Spark Scaler for Load " 040011 DescSize =0xA2 040010 Desc ="FN082 - Do not edit first or last entries. Provides row scaling for the following tables;\r\n\r\n'MFA EGR Multiplier' (aka FN1223)\r\n'MFA PT Spark Adder' (aka FN1124)" 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x300 040200 ZEq =X,TH|0|0|0|0| 040304 YOutType =0x2 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x5 040305 Cols =0x1 040320 XUnits ="load" 040325 YUnits ="row" 040330 ZUnits ="" 040350 XLabels = 040352 XLabelType =0x4 040354 XEq =X/327.68,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/256,TH|0|0|0|0| 040600 XAddress =0x8D32 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x8D34 040750 YOutputDig =0x1 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0xA15 000100 Cat0ID =0xF 040005 Title ="MFA EGR Multiplier" 040011 DescSize =0x45 040010 Desc ="FN1223 - Multiplier used for ramping in managed fuel air EGR tables." 040100 Address =0x9A4E 040200 ZEq =X/128,TH|0|0|0|0| 040203 XOutType =0x4 040304 YOutType =0x4 040210 DecimalPl =0x3 040230 RangeLow =0.0000 040240 RangeHigh =250.0000 040300 Rows =0x3 040305 Cols =0x4 040320 XUnits ="rpm" 040325 YUnits ="load" 040330 ZUnits ="multiplier" 040350 XLabels = 500, 700, 900, 1100 040352 XLabelType =0x4 040354 XEq =X,TH|0|0|0|0| 040360 YLabels =0.050,0.100,0.200 040362 YLabelType =0x4 040364 YEq =X,TH|0|0|0|0| 040500 XLabelLink =0x3987 040505 XLabelSource =0x2 040510 YLabelLink =0x2D8C 040515 YLabelSource =0x2 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x3AAD 000100 Cat0ID =0xF 040005 Title ="MFA Fuel Multiplier Table" 040011 DescSize =0xFA 040010 Desc ="FN1328 - Open loop mode multiplier that adjusts the desired A/F ratio when the conditions for economy mode are met and the 'Allow MFA Strategy' (aka MFASW) flag is set.\r\nMultiplier values less than 1 increase fuel, values greater than 1 reduce fuel." 040100 Address =0x9069 040200 ZEq =X/128,TH|0|0|0|0| 040203 XOutType =0x4 040304 YOutType =0x4 040210 DecimalPl =0x3 040230 RangeLow =0.0000 040240 RangeHigh =250.0000 040300 Rows =0x8 040305 Cols =0xA 040320 XUnits ="rpm" 040325 YUnits ="load%" 040330 ZUnits ="multiplier" 040350 XLabels = 500, 700, 900, 1100, 1300, 1500, 2000, 2500, 3000, 4000 040352 XLabelType =0x4 040354 XEq =X,TH|0|0|0|0| 040360 YLabels =0.08,0.15,0.27,0.40,0.55,0.70,0.80,0.90 040362 YLabelType =0x4 040364 YEq =X,TH|0|0|0|0| 040500 XLabelLink =0x7CE5 040505 XLabelSource =0x2 040510 YLabelLink =0x6012 040515 YLabelSource =0x2 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x6561 000100 Cat0ID =0x2 040005 Title ="MFA PT Spark Adder" 040011 DescSize =0xA 040010 Desc ="FN1124 - " 040100 Address =0x96B4 040150 Flags =0x1 040200 ZEq =X/4,TH|0|0|0|0| 040203 XOutType =0x4 040304 YOutType =0x4 040230 RangeLow =0.0000 040240 RangeHigh =100.0000 040300 Rows =0x3 040305 Cols =0x4 040320 XUnits ="rpm" 040325 YUnits ="load" 040330 ZUnits ="" 040350 XLabels = 900,1267,1633,2000 040352 XLabelType =0x4 040354 XEq =X,TH|0|0|0|0| 040360 YLabels =0.18,0.29,0.52 040362 YLabelType =0x4 040364 YEq =X,TH|0|0|0|0| 040500 XLabelLink =0x3987 040505 XLabelSource =0x2 040510 YLabelLink =0x2D8C 040515 YLabelSource =0x2 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x22C5 000100 Cat0ID =0x5 000101 Cat1ID =0xFF 040005 Title ="Peak Load at Sea Level vs RPM" 040011 DescSize =0x13B 040010 Desc ="FN035 - Used in the calculation of load% when the 'Percent Load Switch' (aka PRLDSW) parameter is not set. Adjust when the volumetric efficiency of the engine has changed. The values in the output column are the maximum peak load for a given RPM when at sea level and the inlet air charge temperature is 100 deg F." 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x300 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x7 040305 Cols =0x1 040320 XUnits ="rpm" 040325 YUnits ="load" 040330 ZUnits ="" 040350 XLabels = 040352 XLabelType =0x4 040354 XEq =X/4,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/327.68,TH|0|0|0|0| 040600 XAddress =0x9C90 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x9C92 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x653B 000100 Cat0ID =0x2 040005 Title ="PT Spark Adder for ECT vs Load" 040011 DescSize =0xA 040010 Desc ="FN1133 - " 040100 Address =0x9710 040150 Flags =0x1 040200 ZEq =X/4,TH|0|0|0|0| 040203 XOutType =0x4 040304 YOutType =0x4 040230 RangeLow =-50.0000 040240 RangeHigh =50.0000 040300 Rows =0x8 040305 Cols =0x7 040320 XUnits ="deg F" 040325 YUnits ="load" 040330 ZUnits ="" 040350 XLabels = 60, 75, 91,106,196,210,230 040352 XLabelType =0x4 040354 XEq =X,TH|0|0|0|0| 040360 YLabels =0.050,0.100,0.200,0.300,0.400,0.500,0.600,0.750 040362 YLabelType =0x4 040364 YEq =X,TH|0|0|0|0| 040500 XLabelLink =0x3658 040505 XLabelSource =0x2 040510 YLabelLink =0x618F 040515 YLabelSource =0x2 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x6532 000100 Cat0ID =0x2 040005 Title ="PT Spark Adder for EGR" 040011 DescSize =0x9B 040010 Desc ="FN1121 - The result of this table lookup is multiplied by the 'Actual EGR Percent' (aka EGRACT) value to give a spark adder value whilst at part throttle." 040100 Address =0x9664 040150 Flags =0x1 040200 ZEq =X/64,TH|0|0|0|0| 040203 XOutType =0x4 040304 YOutType =0x4 040230 RangeLow =0.0000 040240 RangeHigh =250.0000 040300 Rows =0x8 040305 Cols =0xA 040320 XUnits ="rpm" 040325 YUnits ="load" 040330 ZUnits ="multiplier" 040350 XLabels = 500, 700, 900, 1100, 1300, 1500, 2000, 2500, 3000, 4000 040352 XLabelType =0x4 040354 XEq =X,TH|0|0|0|0| 040360 YLabels =0.050,0.100,0.200,0.300,0.400,0.500,0.600,0.750 040362 YLabelType =0x4 040364 YEq =X,TH|0|0|0|0| 040500 XLabelLink =0x7CE5 040505 XLabelSource =0x2 040510 YLabelLink =0x618F 040515 YLabelSource =0x2 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x4CF3 000100 Cat0ID =0x2 000101 Cat1ID =0xFF 040005 Title ="PT Spark Adder for ACT" 040011 DescSize =0x6 040010 Desc ="FN126" 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0xC0 040200 ZEq =X,TH|0|0|0|0| 040203 XOutType =0x2 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x5 040305 Cols =0x1 040320 XUnits ="deg F" 040325 YUnits ="deg adv" 040330 ZUnits ="" 040350 XLabels =Air Charge Temperature,Spark Advance [deg adv] 040352 XLabelType =0x4 040354 XEq =X*2,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/4,TH|0|0|0|0| 040600 XAddress =0x94EE 040610 XDataSize =0x1 040620 XAddrStep =-2 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x94EF 040710 YDataSize =0x1 040720 YAddrStep =-2 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x3658 000100 Cat0ID =0x8 000101 Cat1ID =0xFF 040005 Title ="PT Spark Scaler for ECT" 040011 DescSize =0x8E 040010 Desc ="FN033 - Do not edit first or last entries. Provides column scaling for the following table;\r\n\r\n'PT Spark Adder for ECT and Load' (aka FN1133)" 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x340 040200 ZEq =X,TH|0|0|0|0| 040203 XOutType =0x2 040304 YOutType =0x2 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x9 040305 Cols =0x1 040320 XUnits ="deg F" 040325 YUnits ="row" 040330 ZUnits ="" 040350 XLabels =ECT,Table Index 040352 XLabelType =0x4 040354 XEq =X*2,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/256,TH|0|0|0|0| 040600 XAddress =0x9488 040650 XOutputDig =0x1 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x948A 040750 YOutputDig =0x1 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x49E7 000100 Cat0ID =0x5 000101 Cat1ID =0xFF 040005 Title ="Sea Level Multiplier vs BP" 040011 DescSize =0x13E 040010 Desc ="FN212A - Used in sea level spark, open loop fuel and EGR calculations. Should be set to 0.000 at high altitudes and 1.000 at sea level. Values must overlap with the 'Altitude Multiplier vs BP' (aka FN129A) table. \r\n\r\nFor EGR, this is a multiplier of the result of the 'EGR Sea Level Table' (aka FN908A) table lookup." 040020 SubType =0x7 040100 Address =0x0 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x5 040305 Cols =0x1 040320 XUnits ="in Hg" 040325 YUnits ="multiplier" 040330 ZUnits ="" 040350 XLabels =Barometric Pressure 040352 XLabelType =0x4 040354 XEq =X/8,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/128,TH|0|0|0|0| 040600 XAddress =0x98EE 040610 XDataSize =0x1 040620 XAddrStep =-2 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x98EF 040710 YDataSize =0x1 040720 YAddrStep =-2 040750 YOutputDig =0x3 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x66C9 000100 Cat0ID =0x7 000101 Cat1ID =0xFF 040005 Title ="Shift Indicator Light RPM vs ECT" 040011 DescSize =0x80 040010 Desc ="FN651 - Output value is added to 'Shift Indicator Light RPM vs Load' value to determine shift indicator light on rpm threshold." 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x340 040200 ZEq =X,TH|0|0|0|0| 040203 XOutType =0x2 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x7 040305 Cols =0x1 040320 XUnits ="deg F" 040325 YUnits ="rpm" 040330 ZUnits ="" 040350 XLabels =ECT 040352 XLabelType =0x4 040354 XEq =X*2,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/4,TH|0|0|0|0| 040600 XAddress =0x8C34 040650 XOutputDig =0x1 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x8C36 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x66CA 000100 Cat0ID =0x7 000101 Cat1ID =0xFF 040005 Title ="Shift Indicator Light RPM vs Load" 040011 DescSize =0x80 040010 Desc ="FN652A - Output value is added to 'Shift Indicator Light RPM vs ECT' value to determine shift indicator light on rpm threshold." 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x300 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0xA 040305 Cols =0x1 040320 XUnits ="load" 040325 YUnits ="rpm" 040330 ZUnits ="" 040350 XLabels =Load 040352 XLabelType =0x4 040354 XEq =X/327.68,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/4,TH|0|0|0|0| 040600 XAddress =0x8C50 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x8C52 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0xBF0 000100 Cat0ID =0x2 040005 Title ="Spark Altitude Table" 040011 DescSize =0x180 040010 Desc ="FN905A - The result of this table lookup is multiplied by the result of the 'Altitude Multiplier vs BP' (aka FN129A) lookup. This is part of the ecu's interpolation between the 'Spark Altitude Table' and the 'Spark Sea Level Table' (aka FN904A) during normal part throttle operation. \r\n\r\nTo eliminate this interpolation use the 'Spark Interpolation Inhibit' (aka Z_SPKINT) parameter." 040100 Address =0x9614 040200 ZEq =X/4,TH|0|0|0|0| 040203 XOutType =0x4 040304 YOutType =0x4 040230 RangeLow =0.0000 040240 RangeHigh =60.0000 040300 Rows =0x8 040305 Cols =0xA 040320 XUnits ="rpm" 040325 YUnits ="load" 040330 ZUnits ="deg adv" 040350 XLabels = 500, 700, 900, 1100, 1300, 1500, 2000, 2500, 3000, 4000 040352 XLabelType =0x4 040354 XEq =X,TH|0|0|0|0| 040360 YLabels =0.050,0.100,0.200,0.300,0.400,0.500,0.600,0.750 040362 YLabelType =0x4 040364 YEq =X,TH|0|0|0|0| 040500 XLabelLink =0x7CE5 040505 XLabelSource =0x2 040510 YLabelLink =0x618F 040515 YLabelSource =0x2 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x4775 000100 Cat0ID =0x2 040005 Title ="Spark Base Table" 040011 DescSize =0x42 040010 Desc ="FN901 - A more aggressive spark advance used during acceleration." 040100 Address =0x9574 040200 ZEq =X/4,TH|0|0|0|0| 040203 XOutType =0x4 040304 YOutType =0x4 040230 RangeLow =0.0000 040240 RangeHigh =60.0000 040300 Rows =0x8 040305 Cols =0xA 040320 XUnits ="rpm" 040325 YUnits ="load" 040330 ZUnits ="deg adv" 040350 XLabels = 500, 700, 900, 1100, 1300, 1500, 2000, 2500, 3000, 4000 040352 XLabelType =0x4 040354 XEq =X,TH|0|0|0|0| 040360 YLabels =0.050,0.100,0.200,0.300,0.400,0.500,0.600,0.750 040362 YLabelType =0x4 040364 YEq =X,TH|0|0|0|0| 040500 XLabelLink =0x7CE5 040505 XLabelSource =0x2 040510 YLabelLink =0x618F 040515 YLabelSource =0x2 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x1425 000100 Cat0ID =0x2 040005 Title ="Spark Sea Level Table" 040011 DescSize =0x181 040010 Desc ="FN904A - The result of this table lookup is multiplied by the result of the 'Sea Level Multiplier vs BP' (aka FN212A) lookup. This is part of the ecu's interpolation between the 'Spark Sea Level Table' and the 'Spark Altitude Table' (aka FN905A) during normal part throttle operation. \r\n\r\nTo eliminate this interpolation use the 'Spark Interpolation Inhibit' (aka Z_SPKINT) parameter." 040100 Address =0x95C4 040200 ZEq =X/4,TH|0|0|0|0| 040203 XOutType =0x4 040304 YOutType =0x4 040230 RangeLow =0.0000 040240 RangeHigh =60.0000 040300 Rows =0x8 040305 Cols =0xA 040320 XUnits ="rpm" 040325 YUnits ="load" 040330 ZUnits ="deg adv" 040350 XLabels = 500, 700, 900, 1100, 1300, 1500, 2000, 2500, 3000, 4000 040352 XLabelType =0x4 040354 XEq =X,TH|0|0|0|0| 040360 YLabels =0.050,0.100,0.200,0.300,0.400,0.500,0.600,0.750 040362 YLabelType =0x4 040364 YEq =X,TH|0|0|0|0| 040500 XLabelLink =0x7CE5 040505 XLabelSource =0x2 040510 YLabelLink =0x618F 040515 YLabelSource =0x2 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x7CE5 000100 Cat0ID =0x8 000101 Cat1ID =0xFF 040005 Title ="Spark, Injector Timing, MAF Backflow Scaler for RPM" 040011 DescSize =0x187 040010 Desc ="FN070 - Do not edit first or last entries. Provides column scaling for the following tables;\r\n\r\n'Adaptive Control Learning Table'\r\n'EGR Altitude Table'\r\n'EGR Sea Level Table'\r\n'Failed Mass Air Flow Sensor'\r\n'Injector Timing'\r\n'MAF Backflow Correction'\r\n'MFA Fuel Table'\r\n'PT Spark Adder for EGR'\r\n'Spark Altitude Table'\r\n'Spark Base Table'\r\n'Spark Sea Level Table'\r\n'Torque Reduction Table'" 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x300 040200 ZEq =X,TH|0|0|0|0| 040304 YOutType =0x2 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x7 040305 Cols =0x1 040320 XUnits ="rpm" 040325 YUnits ="column" 040330 ZUnits ="" 040350 XLabels =Speed,Table Column (X) Index 040352 XLabelType =0x4 040354 XEq =X/4,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/256,TH|0|0|0|0| 040600 XAddress =0x8CDE 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x8CE0 040750 YOutputDig =0x1 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x4826 000100 Cat0ID =0x2 000101 Cat1ID =0xFF 040005 Title ="Startup Kicker Time Delay" 040011 DescSize =0xC8 040010 Desc ="FN400 - If the time since exiting crank is greater that the result of this lookup, and the rpm is greater than the 'Startup Kicker Min RPM' value, then 'CT Spark Subtractor for BP' table is not used." 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x40 040200 ZEq =X,TH|0|0|0|0| 040203 XOutType =0x2 040304 YOutType =0x2 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x6 040305 Cols =0x1 040320 XUnits ="deg F at start" 040325 YUnits ="secs" 040330 ZUnits ="" 040350 XLabels = 040352 XLabelType =0x4 040354 XEq =X*2,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X,TH|0|0|0|0| 040600 XAddress =0x9568 040610 XDataSize =0x1 040620 XAddrStep =-2 040650 XOutputDig =0x1 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x9569 040710 YDataSize =0x1 040720 YAddrStep =-2 040750 YOutputDig =0x1 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x31B9 000100 Cat0ID =0x2 040005 Title ="Torque Reduction Table" 040011 DescSize =0x7 040010 Desc ="FN1119" 040100 Address =0x96C0 040150 Flags =0x1 040200 ZEq =X/4,TH|0|0|0|0| 040203 XOutType =0x4 040304 YOutType =0x4 040230 RangeLow =0.0000 040240 RangeHigh =250.0000 040300 Rows =0x8 040305 Cols =0xA 040320 XUnits ="rpm" 040325 YUnits ="load" 040330 ZUnits ="deg adv" 040350 XLabels =(null),(null),(null),(null),(null),(null),(null),(null),(null),(null) 040352 XLabelType =0x4 040354 XEq =X,TH|0|0|0|0| 040360 YLabels =(null),(null),(null),(null),(null),(null),(null),(null) 040362 YLabelType =0x4 040364 YEq =X,TH|0|0|0|0| 040500 XLabelLink =0x7CE5 040505 XLabelSource =0x2 040510 YLabelLink =0x618F 040515 YLabelSource =0x2 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x29C8 000100 Cat0ID =0x8 000101 Cat1ID =0xFF 040005 Title ="TP Scaler for MAF Failure" 040011 DescSize =0xB5 040010 Desc ="FN098 - Do not edit first or last entries. Provides row scaling for the following table using the relative throttle position as the input value;\r\n\r\n'Failed MAF Sensor' (aka FN1358)" 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x300 040200 ZEq =X,TH|0|0|0|0| 040304 YOutType =0x2 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x7 040305 Cols =0x1 040320 XUnits ="volts" 040325 YUnits ="row" 040330 ZUnits ="" 040350 XLabels = 040352 XLabelType =0x4 040354 XEq =X/12800,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/256,TH|0|0|0|0| 040600 XAddress =0x90C6 040650 XOutputDig =0x3 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x90C8 040750 YOutputDig =0x1 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x4614 000100 Cat0ID =0x10 000101 Cat1ID =0xFF 040005 Title ="Transmission Time Delay" 040011 DescSize =0x76 040010 Desc ="FN394F - Used to delay the change in state of the DNDSUP flag until the transmission actually engages or disengages. " 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x40 040200 ZEq =X,TH|0|0|0|0| 040203 XOutType =0x2 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x7 040305 Cols =0x1 040320 XUnits ="deg F" 040325 YUnits ="secs" 040330 ZUnits ="" 040350 XLabels =ECT 040352 XLabelType =0x4 040354 XEq =X*2,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/8,TH|0|0|0|0| 040600 XAddress =0x8C26 040610 XDataSize =0x1 040620 XAddrStep =-2 040650 XOutputDig =0x1 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x8C27 040710 YDataSize =0x1 040720 YAddrStep =-2 040750 YOutputDig =0x3 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%CHECKSUM%% 000002 UniqueID =0x4C 010005 Title ="Checksum" 010010 DataStart =0x2000 010015 DataEnd =0x9FFF 010022 DataSizeBits =0x10 010025 StoreAddr =0x200A 010030 CalcMethod =0x1 010050 Flags =0x1 %%END%% %%TABLE%% 000002 UniqueID =0x2608 000100 Cat0ID =0x1 000101 Cat1ID =0xFF 040005 Title ="Underspeed Fuel Multiplier" 040011 DescSize =0xB7 040010 Desc ="FN387 - A multiplier of the 'Decel Fuel Shut Off Multiplier' lookup value when in underspeed mode.\r\nMultiplier values less than 1 decrease fuel, values greater than 1 increase fuel." 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x40 040200 ZEq =X,TH|0|0|0|0| 040203 XOutType =0x2 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x9 040305 Cols =0x1 040320 XUnits ="deg F" 040325 YUnits ="muliplier" 040330 ZUnits ="" 040350 XLabels =ECT 040352 XLabelType =0x4 040354 XEq =X*2,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/64,TH|0|0|0|0| 040600 XAddress =0x989E 040610 XDataSize =0x1 040620 XAddrStep =-2 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x989F 040710 YDataSize =0x1 040720 YAddrStep =-2 040750 YOutputDig =0x3 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x1FD0 000100 Cat0ID =0x1 000101 Cat1ID =0xFF 040005 Title ="WOT Fuel Multiplier vs RPM" 040011 DescSize =0x84 040010 Desc ="FN303 - Adjusts the desired A/F ratio when at WOT.\r\nMultiplier values less than 1 increase fuel, values greater than 1 reduce fuel." 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x300 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x8 040305 Cols =0x1 040320 XUnits ="rpm" 040325 YUnits ="multiplier" 040330 ZUnits ="" 040350 XLabels =RPM,WOT Fuel Multiplier 040352 XLabelType =0x4 040354 XEq =X/4,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/128,TH|0|0|0|0| 040600 XAddress =0x9B80 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x9B82 040750 YOutputDig =0x3 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x421A 000100 Cat0ID =0x2 000101 Cat1ID =0xFF 040005 Title ="WOT Spark Advance vs ACT" 040011 DescSize =0x55 040010 Desc ="FN135 - Spark advance added to 'WOT Spark Advance vs RPM' (aka FN131) lookup result." 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0xC0 040200 ZEq =X,TH|0|0|0|0| 040203 XOutType =0x2 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x7 040305 Cols =0x1 040320 XUnits ="deg F" 040325 YUnits ="deg adv" 040330 ZUnits ="" 040350 XLabels =Intake Air Charge Temp,WOT Spark Advance 040352 XLabelType =0x4 040354 XEq =X*2,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/4,TH|0|0|0|0| 040600 XAddress =0x9540 040610 XDataSize =0x1 040620 XAddrStep =-2 040650 XOutputDig =0x1 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x9541 040710 YDataSize =0x1 040720 YAddrStep =-2 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x2660 000100 Cat0ID =0x2 000101 Cat1ID =0xFF 040005 Title ="WOT Spark Advance vs BP" 040011 DescSize =0x56 040010 Desc ="FN133 - Spark advance added to 'WOT Spark Advance vs RPM' (aka FN131) lookup result." 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x80 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x5 040305 Cols =0x1 040320 XUnits ="in Hg" 040325 YUnits ="deg adv" 040330 ZUnits ="" 040350 XLabels =Barometric Pressure,Spark Adder 040352 XLabelType =0x4 040354 XEq =X/8,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/4,TH|0|0|0|0| 040600 XAddress =0x9528 040610 XDataSize =0x1 040620 XAddrStep =-2 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x9529 040710 YDataSize =0x1 040720 YAddrStep =-2 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x38D4 000100 Cat0ID =0x2 000101 Cat1ID =0xFF 040005 Title ="WOT Spark Advance vs ECT" 040011 DescSize =0x56 040010 Desc ="FN134 - Spark advance added to 'WOT Spark Advance vs RPM' (aka FN131) lookup result." 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0xC0 040200 ZEq =X,TH|0|0|0|0| 040203 XOutType =0x2 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x7 040305 Cols =0x1 040320 XUnits ="deg F" 040325 YUnits ="deg adv" 040330 ZUnits ="" 040350 XLabels =Engine Coolant Temp,WOT SparkAdvance 040352 XLabelType =0x4 040354 XEq =X*2,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/4,TH|0|0|0|0| 040600 XAddress =0x9532 040610 XDataSize =0x1 040620 XAddrStep =-2 040650 XOutputDig =0x1 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x9533 040710 YDataSize =0x1 040720 YAddrStep =-2 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%TABLE%% 000002 UniqueID =0x6F6E 000100 Cat0ID =0x2 000101 Cat1ID =0xFF 040005 Title ="WOT Spark Advance vs RPM" 040011 DescSize =0x23 040010 Desc ="FN131 - Spark advance used at WOT." 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x380 040200 ZEq =X,TH|0|0|0|0| 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x9 040305 Cols =0x1 040320 XUnits ="rpm" 040325 YUnits ="deg adv" 040330 ZUnits ="" 040350 XLabels =RPM,WOT Spark Advance 040352 XLabelType =0x4 040354 XEq =X/4,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X/4,TH|0|0|0|0| 040600 XAddress =0x9504 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x9506 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%FLAG%% 000002 UniqueID =0x66FC 000100 Cat0ID =0x1 030005 Title ="Allow Accel Enrichment" 030011 DescSize =0x5A 030010 Desc ="AEFLAG - Set to allow acceleration enrichment.\r\n\r\nDoes not appear to be used in this ecu." 030100 Address =0x9004 030200 BitNumber =0x0 %%END%% %%FLAG%% 000002 UniqueID =0x178B 000100 Cat0ID =0x9 030005 Title ="Allow Brake On/Off Test" 030011 DescSize =0x1B 030010 Desc ="VBISW - Set to permit test" 030100 Address =0x8EEC 030200 BitNumber =0x0 %%END%% %%FLAG%% 000002 UniqueID =0x3581 000100 Cat0ID =0xB 030005 Title ="Allow C/L Re-entry on HEGO Failure" 030011 DescSize =0x57 030010 Desc ="LOESSW - Set to permit re-entry into closed loop fuelling when EGOs are not switching." 030100 Address =0x93E0 030200 BitNumber =0x0 %%END%% %%FLAG%% 000002 UniqueID =0x71BC 000100 Cat0ID =0xC 030005 Title ="Allow EPT at Idle" 030011 DescSize =0x49 030010 Desc ="EPTSW - Set to permit the 'EPT at Idle' (EPTZER) value to be calculated." 030100 Address =0x97D8 030200 BitNumber =0x0 %%END%% %%FLAG%% 000002 UniqueID =0x1E50 000100 Cat0ID =0x9 030005 Title ="Allow Fuel Pump Monitor Test" 030011 DescSize =0x45 030010 Desc ="V_FPMFLG - Set to permit the Fuel Pump Monitor Test to be performed." 030100 Address =0x8ECD 030200 BitNumber =0x0 %%END%% %%FLAG%% 000002 UniqueID =0x951 000100 Cat0ID =0x9 030005 Title ="Allow Goose Test" 030011 DescSize =0x1D 030010 Desc ="V_GOOSW - Set to permit test" 030100 Address =0x8EE6 030200 BitNumber =0x0 %%END%% %%FLAG%% 000002 UniqueID =0x37C1 000100 Cat0ID =0x9 030005 Title ="Allow HEGO Switch Test" 030011 DescSize =0x1C 030010 Desc ="VEGOBP - Set to permit test" 030100 Address =0x8EFE 030200 BitNumber =0x0 %%END%% %%FLAG%% 000002 UniqueID =0x3B7C 000100 Cat0ID =0xF 030005 Title ="Allow MFA Strategy" 030011 DescSize =0x37 030010 Desc ="MFASW - Set for fuel economy mode strategy to be used." 030100 Address =0x8FDD 030200 BitNumber =0x0 %%END%% %%FLAG%% 000002 UniqueID =0x1F48 000100 Cat0ID =0xD 030005 Title ="Allow O/L Canister Purge" 030011 DescSize =0x38 030010 Desc ="PURGSW - Set to permit canister purge during open loop." 030100 Address =0x93EF 030200 BitNumber =0x0 %%END%% %%FLAG%% 000002 UniqueID =0xBA9 000100 Cat0ID =0x9 030005 Title ="Allow Power Steering Test" 030011 DescSize =0x45 030010 Desc ="VPSSW - Set to permit testing of the power steering pressure switch." 030100 Address =0x8FA6 030200 BitNumber =0x0 %%END%% %%FLAG%% 000002 UniqueID =0x3F38 000100 Cat0ID =0x9 030005 Title ="Allow Secondary Air Test" 030011 DescSize =0x7 030010 Desc ="VAIRFL" 030100 Address =0x8EA7 030200 BitNumber =0x0 %%END%% %%FLAG%% 000002 UniqueID =0x57DA 000100 Cat0ID =0x9 030005 Title ="Allow SPOUT Test" 030011 DescSize =0x1C 030010 Desc ="VSPTEN - Set to permit test" 030100 Address =0x8FAE 030200 BitNumber =0x0 %%END%% %%FLAG%% 000002 UniqueID =0x5C7C 000100 Cat0ID =0x9 030005 Title ="Allow Thermactor Test" 030011 DescSize =0x7 030010 Desc ="VTABFL" 030100 Address =0x8EA8 030200 BitNumber =0x0 %%END%% %%FLAG%% 000002 UniqueID =0x1C7 000100 Cat0ID =0x9 030005 Title ="Allow VSS Test" 030011 DescSize =0x1B 030010 Desc ="VSSSW - Set to permit test" 030100 Address =0x8FD3 030200 BitNumber =0x0 %%END%% %%FLAG%% 000002 UniqueID =0xC49 000100 Cat0ID =0xE 030005 Title ="Alternator Control Present" 030011 DescSize =0x121 030010 Desc ="ECADHP - Set if an Electronically Controlled Accessory Drive (ECAD) module is present. This module monitors alternator demand and signals the eec when demand is low. If the appropriate conditions are met then the eec signals the ECAD module that the alternator is to be run at half speed." 030100 Address =0x93E1 030200 BitNumber =0x0 %%END%% %%FLAG%% 000002 UniqueID =0x3AE7 000100 Cat0ID =0x3 030005 Title ="BAP Sensor Present" 030011 DescSize =0x37 030010 Desc ="BPSSW - Set if a Barometric Pressure Sensor is fitted." 030100 Address =0x947B 030200 BitNumber =0x0 %%END%% %%FLAG%% 000002 UniqueID =0x73B4 000100 Cat0ID =0x7 030005 Title ="Brake Switch Present" 030011 DescSize =0x2A 030010 Desc ="BIHP - Set if brake pedal switch present." 030100 Address =0x93BB 030200 BitNumber =0x0 %%END%% %%FLAG%% 000002 UniqueID =0x764B 000100 Cat0ID =0x9 030005 Title ="Bypass Fault Reporting" 030011 DescSize =0x57 030010 Desc ="VDISFM - Set to inhibit fault reporting. Not sure which fault reporting this prevents." 030100 Address =0x8EE8 030200 BitNumber =0x0 %%END%% %%FLAG%% 000002 UniqueID =0x5997 000100 Cat0ID =0x7 030005 Title ="CID Sensor Present" 030011 DescSize =0x57 030010 Desc ="HP_CID - Set if cylinder identification hardware present, e.g. for an EDIS conversion." 030100 Address =0x9E66 030200 BitNumber =0x0 %%END%% %%FLAG%% 000002 UniqueID =0x48C 000100 Cat0ID =0x7 030005 Title ="CID Sensor Type" 030011 DescSize =0x6D 030010 Desc ="HP_CIDSEL - set for Variable Reluctance sensor, clear for a Hall Effect sensor. Used for an EDIS conversion." 030100 Address =0x9E67 030200 BitNumber =0x0 %%END%% %%FLAG%% 000002 UniqueID =0x78EC 000100 Cat0ID =0x2 030005 Title ="Computer Controlled Dwell Present" 030011 DescSize =0x89 030010 Desc ="CCDSW - Set if dwell is computer controlled and a \"black\" CCD TFI module is used otherwise dwell is TFI controlled with a \"gray\" module." 030100 Address =0x944A 030200 BitNumber =0x0 %%END%% %%FLAG%% 000002 UniqueID =0x6B55 000100 Cat0ID =0x1 030005 Title ="Crank Injector Timing" 030011 DescSize =0x76 030010 Desc ="EDSEL - Set to use the rising edge of the PIP for injector firing during cranking otherwise the falling edge is used." 030100 Address =0x9AB2 030200 BitNumber =0x0 %%END%% %%FLAG%% 000002 UniqueID =0x5F49 000100 Cat0ID =0x1 030005 Title ="Decel Fuel Shut Off PT Enable" 030011 DescSize =0x9B 030010 Desc ="PTDFSW - Set for PT deceleration fuel shut off, clear for CT deceleration fuel shut off. It is not advisable to set this as it can cause engine 'clunk'. " 030100 Address =0x9AE1 030200 BitNumber =0x0 %%END%% %%FLAG%% 000002 UniqueID =0x2371 000100 Cat0ID =0x7 030005 Title ="Electro Drive Fan Present" 030011 DescSize =0x30 030010 Desc ="EDFHP - Set if an electro drive fan is present." 030100 Address =0x941C 030200 BitNumber =0x0 %%END%% %%FLAG%% 000002 UniqueID =0x3750 000100 Cat0ID =0x7 030005 Title ="Enable Special Injector Timing at Idle" 030011 DescSize =0x7F 030010 Desc ="CIDRSW - Set to fix the injector timing to the 'Injector Timing Value at Idle' (aka MIDTV) value when the vehicle is in drive." 030100 Address =0x9ABC 030200 BitNumber =0x0 %%END%% %%FLAG%% 000002 UniqueID =0x5328 000100 Cat0ID =0x7 030005 Title ="Enable Special Injector Timing in Neutral" 030011 DescSize =0x65 030010 Desc ="CINTSW - Set to fix the injector timing to the 'Injector Timing Value in Neutral' (aka CINTV) value." 030100 Address =0x8FDE 030200 BitNumber =0x0 %%END%% %%FLAG%% 000002 UniqueID =0x7EB2 000100 Cat0ID =0x1 030005 Title ="Force Background Fuel" 030011 DescSize =0x40 030010 Desc ="BFULSW - Set to prevent foreground fuel pulsewidth calculation." 030100 Address =0x8E5C 030200 BitNumber =0x0 %%END%% %%FLAG%% 000002 UniqueID =0x4F26 000100 Cat0ID =0x2 030005 Title ="High Data Rate Electronic Spark Present" 030011 DescSize =0x29 030010 Desc ="HP_HIDRES - Used for an EDIS conversion." 030100 Address =0x9449 030200 BitNumber =0x0 %%END%% %%FLAG%% 000002 UniqueID =0x1E31 000100 Cat0ID =0x7 030005 Title ="High Speed Fan Present" 030011 DescSize =0x3B 030010 Desc ="HEDFHP - Set if the electro drive fan is a two speed unit." 030100 Address =0x941D 030200 BitNumber =0x0 %%END%% %%FLAG%% 000002 UniqueID =0x2814 000100 Cat0ID =0x7 030005 Title ="Injector Timing Edge" 030011 DescSize =0x79 030010 Desc ="INJREF - Indicates which edge of the fuel pulse is used for the injector timing, clear = rising edge, set = falling edge" 030100 Address =0x8FFA 030200 BitNumber =0x0 %%END%% %%FLAG%% 000002 UniqueID =0x4FAD 000100 Cat0ID =0x2 030005 Title ="Knock Sensor Present" 030011 DescSize =0x29 030010 Desc ="KIHP - Set if a knock sensor is present." 030100 Address =0x947A 030200 BitNumber =0x0 %%END%% %%FLAG%% 000002 UniqueID =0x6D31 000100 Cat0ID =0x1 030005 Title ="Lambda Reset Switch" 030011 DescSize =0x6E 030010 Desc ="LAMSW - Set if desired A/F ratio is to be clipped to be no leaner than 14.64 when transiting from O/L to C/L." 030100 Address =0x9E64 030200 BitNumber =0x0 %%END%% %%FLAG%% 000002 UniqueID =0x3947 000100 Cat0ID =0x2 030005 Title ="Lugging Timer Reset Switch" 030011 DescSize =0x90 030010 Desc ="LUGSW - If set then the 'Lugging Timer' (aka LUGTMR) is cleared before the Lugging Timer Up Flag is cleared and Lugging Timer Down Flag is set." 030100 Address =0x9440 030200 BitNumber =0x0 %%END%% %%FLAG%% 000002 UniqueID =0x70DC 000100 Cat0ID =0x5 030005 Title ="Percent Load Switch" 030011 DescSize =0x22A 030010 Desc ="PRLDSW - Used for determining the value of load%.\r\n\r\nSet for load% = load\r\nClear for load% = load/peak load\r\n\r\nIf this parameter is altered then the following parameters will/may need adjusting to suit;\r\n\r\n'Fuel Lugging Mode O/L Min Load%' (aka LDMH)\r\n'Fuel Lugging Mode O/L Min Load% Hysteresis' (aka LDMHH)\r\n'Fuel Scaler for Load%' (aka FN072A)\r\n'Load% Min for O/L Hysteresis' (aka HLODH)\r\n'Load% Min for O/L vs ECT' (aka FN320A)\r\n'Thermactor Upstream Air Timer Min Load%' (aka UPLOD)\r\n'Thermactor Upstream Air Timer Min Load% Hysteresis' (aka UPLODH)" 030100 Address =0x9A80 030200 BitNumber =0x0 %%END%% %%FLAG%% 000002 UniqueID =0x3B7A 000100 Cat0ID =0x7 030005 Title ="Power Steering Pressure Switch Present" 030011 DescSize =0x3B 030010 Desc ="PSPSHP - Set if power steering pressure switch is present." 030100 Address =0x93BC 030200 BitNumber =0x0 %%END%% %%FLAG%% 000002 UniqueID =0x6A36 000100 Cat0ID =0x12 030005 Title ="Transient Fuel Compensation Switch" 030011 DescSize =0x69 030010 Desc ="TFCISW - Set if it is assumed the manifold wall is wet at start up, otherwise wall is assumed to be dry." 030100 Address =0x9013 030200 BitNumber =0x0 %%END%%