0x1 v250 Advanced $0E.xdf 16168625, 16196395 and 16197427 PCM with $0E Mask. This xdf covers all of the original applications of the code. It doesn't cover any code modifications or hardware modifications, with the one exception of code modification to allow Desired AFR dataloging in the place of Battery Volts. 93V8S10 0 0 0 ==== READ ME (Parameter Comments) ================== READ ME (Parameter Comments) 0 0 0 0 Disclaimer I make no guarantee as to the accuracy of this definition or any definition created by or modified by me. Use at your own risk! If you break your vehicle, fail emissions testing, or etc…, the fault is yours and no one else's. Good Luck 93V8S10 0 0 XDF Read Me Thanks for using this xdf! I hope it will make tuning easier. When I first began tuning I struggled with incomplete xdf definitions, not knowing what all there was that could be adjusted to help with the problems I was experiencing. With this xdf you should not have that problem, this xdf contains much more than what will ever need to be changed. In fact many of the items should not be changed. Please be careful! Please make use of the "Parameter Comments". These can be viewed by clicking the "Parameter Comments" button in the tool bar at the top of the screen. Please make use of the "Visibility Levels" in the tool bar at the top of the screen. This feature will make using this xdf much easier. Two levels are available, Level 1 and Level 10. Level 1 displays the most basic and most used parameters. Level 10 displays all parameters. Good Luck 93V8S10 0 0 ADX Read Me 1 There are two values that need to be set for your engine, Initial Advance and Injector Flow. Initial Advance: After loading A219 $0E TP5 v250.adx into your definitions menu, and opening, go to the Acquisition menu and open Edit Definition. Click on the + sign beside the word Values. An expanded menu will open. Drop down and click on Spark Advance. Then click on the Conversion tab at the bottom of the screen. Next click on the Set button at the top and change the last number in the equation to the Initial Spark Advance. This can be found at 4132 in the bin file. The Initial Spark Advance should match the advance set at the distributor. This will correct the Spark Advance display. If you decide to leave this as is, then you will need to add the appropriate amount of Spark Advance to the displayed amount when viewing, as the definition is set-up for 0 Initial Advance. Thanks 93V8S10 0 0 ADX Read Me 2 There are two values that need to be set for your engine, Initial Advance and Injector Flow. Injector Flow: After loading A219 $0E TP5 v250.adx into your definitions menu, and opening, go to the Acquisition menu and open Edit Definition. Click on the + sign beside the word Values. An expanded menu will open. Drop down and click on Injector Flow. Read the instructions in the Description box, then click on the Conversion tab, then the Set button at top, and make the appropriate change to the equation. This value should reflect the total flow of your injectors not just their rated flow. Changing this is necessary for the MPG display. If this isn't changed the MPG display will be inaccurate. Happy Tuning 93V8S10 0 0 Desired AFR Data Logging To data log “Desired AFR” instead of “Battery Voltage”; change the value at L5214 to $0249 (Desired AFR). Stock value is $00A7 (Battery Voltage). A scalar is provided for this with the Advanced $0E TP5 v250.xdf. The A219 $0E TP5 v250.adx is set-up with displays for “Battery Voltage” and “Desired AFR”, both will show data, but only one will be correct at any given time. The user must remember how the bin is set-up when viewing the displays. Happy Tuning 93V8S10 0 0 WBO2 Data Logging To data log the WBO2 AFR follow these steps: 1. Connect the WBO2 output to pin B16. This is known as the Linear EGR Pintle Position. 2. The A219 $0E TP5 v250.adx is set-up with a display for WBO2. The input from the WBO2 must be, 0v = 10.0 AFR, 5v = 20.0 AFR. The data in the EGR displays, while using the WBO2, is meaningless and should be ignored. 3. EGR and WBO2 cannot be used at the same time. The EGR must be disabled in the bin. 4. Bin modifications: Flags 1. Code 32 EGR Failure (not set) 2. Linear EGR/EVRV EGR (set) 3. Use L478B Table for %EGR (set) 4. Backpressure EGR (not set) 5. EGR Off in Open Loop (not set) 6. EGR Off at Idle (not set) Tables 1. Desired EGR vs. RPM vs. Vacuum (set to all zeros) 2. EGR Fuel Reduction vs. RPM vs. Vacuum (set to all zeros) Good Luck 93V8S10 0 0 0 0 ==== $0E Parameters ============================ $0E Parameters 0 0 0 0 PROM ID Title: PROM ID Location: 4000 Usage: $0E Parameters Tips: Tracking different chip versions. This can be changed to whatever you wish. Doesn't affect calibration at all. Conversion: ID = 1 * X ID 0 0 0 Platform ID (MSW) Title: Platform ID (MSW) Location: 4002 Usage: $0E Parameters Tips: Conversion: None Hex 3 0 0 Platform ID (LSW) Title: Platform ID (LSW) Location: 4004 Usage: $0E Parameters Tips: Conversion: None Hex 3 0 0 Checksum Title: Checksum Location: 4006 Usage: $0E Parameters Tips: Used to verify the contents of a bin file. If the Checksum doesn't match the contents of the bin file the PCM will enter Limp Home Mode. The checksum can be disabled by entering $AA in Mask ID. Do not change setting here! If setting is changed PCM will see a "Error 51 EPROM Checksum Failure". Checksum is automatically updated when bins are saved with TunerPro. Conversion: None Hex 3 0 0 Mask ID Title: Mask ID Location: 4008 Usage: $0E Parameters Tips: Used to determine the XDF file needed. This will always be expressed in HEX. $ or 0x before a number means that it is in HEX. More information about HEX is contained in the Help section. The checksum can be disabled by entering $AA in Mask ID. Conversion: None Hex 3 0 0 New Checksum 0x4008 0xFFFF 0x4006 0x0 Shutdown Timer Title: Shutdown Timer Location: 4009 Usage: $0E Parameters Tips: Time delay for some PCM functions to cease after ignition is shut off. Conversion: Sec. = 0.012474 * X Sec. 1 0 0 0 0 ==== A/C Clutch Parameters ======================== A/C Clutch Parameters 0 0 0 0 A/C Clutch Off to On TPS Title: A/C Clutch Off to On TPS Location: 4010 Usage: A/C Clutch Parameters Tips: 400F Bit 2 "A/C Clutch Control" must be enabled. Not used on V8 and V6 TBI trucks. Conversion: % TPS = 0.390625 * X % TPS 1 0 0 A/C Clutch On to Off TPS Title: A/C Clutch On to Off TPS Location: 4011 Usage: A/C Clutch Parameters Tips: 400F Bit 2 "A/C Clutch Control" must be enabled. Not used on V8 and V6 TBI trucks. Conversion: % TPS = 0.390625 * X % TPS 1 0 0 A/C Clutch Switch Time Title: A/C Clutch Switch Time Location: 4012 Usage: A/C Clutch Parameters Tips: Prevents unwanted compressor off/ on bounce when dash switch is tuned on. 400F Bit 2 "A/C Clutch Control" must be enabled. Not used on V8 and V6 TBI trucks. Conversion: Sec. = 0.1 * X Sec. 1 0 0 A/C Clutch Minimum Re-enable Time Title: A/C Clutch Minimum Re-enable Time Location: 4013 Usage: A/C Clutch Parameters Tips: 400F Bit 2 "A/C Clutch Control" must be enabled. Not used on V8 and V6 TBI trucks. Conversion: Sec. = 0.1 * X Sec. 1 0 0 A/C Clutch Time Delay after Launch Mode Title: A/C Clutch Time Delay after Launch Mode Location: 4014 Usage: A/C Clutch Parameters Tips: 400F Bit 2 "A/C Clutch Control" must be enabled. Not used on V8 and V6 TBI trucks. Conversion: Sec. = 0.1 * X Sec. 1 0 0 A/C Clutch Hi RPM Disable Delay Title: A/C Clutch Hi RPM Disable Delay Location: 4015 Usage: A/C Clutch Parameters Tips: 400F Bit 2 "A/C Clutch Control" must be enabled. Not used on V8 and V6 TBI trucks. Conversion: Sec. = 0.1 * X Sec. 1 0 0 A/C Clutch Re-enable Time after Hi RPM Title: A/C Clutch Re-enable Time after Hi RPM Location: 4016 Usage: A/C Clutch Parameters Tips: 400F Bit 2 "A/C Clutch Control" must be enabled. Not used on V8 and V6 TBI trucks. Conversion: Sec. = 0.1 * X Sec. 1 0 0 A/C Clutch On to Off RPM Title: A/C Clutch On to Off RPM Location: 4017 Usage: A/C Clutch Parameters Tips: 400F Bit 2 "A/C Clutch Control" must be enabled. Not used on V8 and V6 TBI trucks. Conversion: RPM = 25 * X RPM 0 0 0 A/C Clutch Off to On RPM Title: A/C Clutch Off to On RPM Location: 4018 Usage: A/C Clutch Parameters Tips: 400F Bit 2 "A/C Clutch Control" must be enabled. Not used on V8 and V6 TBI trucks. Conversion: RPM = 25 * X RPM 0 0 0 A/C Clutch Hi RPM Threshold Title: A/C Clutch Durability RPM Threshold Location: 4019 Usage: A/C Clutch Parameters Tips: 400F Bit 2 "A/C Clutch Control" must be enabled. Not used on V8 and V6 TBI trucks. Conversion: RPM = 25 * X RPM 0 0 0 A/C Clutch On to Off Temp Title: A/C Clutch On to Off Temp Location: 401A Usage: A/C Clutch Parameters Tips: 400F Bit 2 "A/C Clutch Control" must be enabled. Not used on V8 and V6 TBI trucks. Conversion: Temp (C) = 0.750 * X + -40 C 1 0 0 A/C Clutch Off to On Temp Title: A/C Clutch Off to On Temp Location: 401B Usage: A/C Clutch Parameters Tips: 400F Bit 2 "A/C Clutch Control" must be enabled. Not used on V8 and V6 TBI trucks. Conversion: Temp (C) = 0.750 * X + -40 Deg C 1 0 0 A/C Clutch Launch Mode Lower MPH Limit, A/C On Title: A/C Clutch Launch Mode Lower MPH Limit, A/C On Location: 401C Usage: A/C Clutch Parameters Tips: 400F Bit 2 "A/C Clutch Control" must be enabled. Not used on V8 and V6 TBI trucks. Conversion: MPH = 1 * X MPH 1 0 0 A/C Clutch Launch Mode Lower MPH Limit, A/C Off Title: A/C Clutch Launch Mode Lower MPH Limit, A/C Off Location: 401D Usage: A/C Clutch Parameters Tips: 400F Bit 2 "A/C Clutch Control" must be enabled. Not used on V8 and V6 TBI trucks. Conversion: MPH = 1 * X MPH 1 0 0 A/C Clutch Launch Mode Lower TPS Limit, A/C Off Title: A/C Clutch Launch Mode Lower TPS Limit, A/C Off Location: 401E Usage: A/C Clutch Parameters Tips: 400F Bit 2 "A/C Clutch Control" must be enabled. Not used on V8 and V6 TBI trucks. Conversion: % TPS = 0.390625 * X % TPS 1 0 0 A/C Clutch Launch Mode Lower TPS Limit, A/C On Title: A/C Clutch Launch Mode Lower TPS Limit, A/C On Location: 401F Usage: A/C Clutch Parameters Tips: 400F Bit 2 "A/C Clutch Control" must be enabled. Not used on V8 and V6 TBI trucks. Conversion: % TPS = 0.390625 * X % TPS 1 0 0 A/C Clutch Re-enable Time after Hi TPS Title: A/C Clutch Re-enable Time after Hi TPS Location: 4020 Usage: A/C Clutch Parameters Tips: 400F Bit 2 "A/C Clutch Control" must be enabled. Not used on V8 and V6 TBI trucks. Conversion: Sec. = 0.1 * X Sec. 1 0 0 A/C Clutch Minimum Run Time for A/C On Title: A/C Clutch Minimum Run Time for A/C On Location: 4022 Usage: A/C Clutch Parameters Tips: 400F Bit 2 "A/C Clutch Control" must be enabled. Not used on V8 and V6 TBI trucks. Conversion: Sec. = 0.1 * X Sec. 1 0 0 0 0 ==== CCP Parameters ============================ CCP Parameters 0 0 0 0 CCP Lower MAP for DC Updates Title: CCP Lower MAP for DC Updates Location: 4024 Usage: CCP Parameters Tips: CCP = Charcoal Canister Purge. DC = duty cycle. Conversion: MAP (Kpa) = 0.369000 * X + 10.35 Kpa 1 0 0 CCP Minimum Time between DC Updates Title: CCP Minimum Time between DC Updates Location: 4025 Usage: CCP Parameters Tips: CCP = Charcoal Canister Purge. DC = duty cycle. Conversion: Sec. = 0.1 * X Sec. 1 0 0 CCP Integrator at which DC Increases Title: CCP Integrator at which DC Increases Location: 4026 Usage: CCP Parameters Tips: CCP = Charcoal Canister Purge. DC = duty cycle. Purge increased by value at L4029 if greater than or equal to L4026. Conversion: None Integrator 2 0 0 CCP Integrator at which DC Decreases Title: CCP Integrator at which DC Decreases Location: 4027 Usage: CCP Parameters Tips: CCP = Charcoal Canister Purge. DC = duty cycle. Purge increased by value at L402A if less than L4027. Conversion: None Integrator 2 0 0 CCP Multiplier for Open Loop Title: CCP Multiplier for Open Loop Location: 4028 Usage: CCP Parameters Tips: CCP = Charcoal Canister Purge. DC = duty cycle. CCP purge DC multiplier added to table at L4043 "CCP DC Minimum vs. Air Flow (Closed Loop)" if in open loop. Conversion: Multiplier = 0.003906 * X Multiplier 0 0 CCP DC Increase Factor Title: CCP DC Increase Factor Location: 4029 Usage: CCP Parameters Tips: CCP = Charcoal Canister Purge. DC = duty cycle. Purge increased by value at L4029 if greater than or equal to L4026. Conversion: % = 0.38823529 * X % 0 0 CCP DC Decrease Factor Title: CCP DC Decrease Factor Location: 402A Usage: CCP Parameters Tips: CCP = Charcoal Canister Purge. DC = duty cycle. Purge increased by value at L402A if less than L4027. Conversion: % = 0.38823529 * X % 0 0 CCP Minimum Temperature Title: CCP Minimum Temperature Location: 402B Usage: CCP Parameters Tips: CCP = Charcoal Canister Purge. DC = duty cycle. Conversion: Temp (C) = 0.750 * X + -40 C 1 0 0 CCP Temperature for Full Purge Title: CCP Temperature for Full Purge Location: 402C Usage: CCP Parameters Tips: CCP = Charcoal Canister Purge. DC = duty cycle. Conversion: Temp (C) = 0.750 * X + -40 C 1 0 0 CCP Run Time for Full DC Purge Title: CCP Run Time for Full DC Purge Location: 402D Usage: CCP Parameters Tips: CCP = Charcoal Canister Purge. DC = duty cycle. Conversion: Sec. = 1 * X Sec. 1 0 0 CCP MPH to Clear Multiplier Title: CCP MPH to Clear Multiplier Location: 402F Usage: CCP Parameters Tips: CCP = Charcoal Canister Purge. DC = duty cycle. Lower speed threshold to clear CCP DC multiplier if CCP not allowed. Conversion: MPH = 1 * X MPH 1 0 0 CCP Off to On MPH Title: CCP Off to On MPH Location: 4030 Usage: CCP Parameters Tips: CCP = Charcoal Canister Purge. Conversion: MPH = 1 * X MPH 1 0 0 CCP Off to On MAP Title: CCP Off to On MAP Location: 4031 Usage: CCP Parameters Tips: CCP = Charcoal Canister Purge. Conversion: MAP (Kpa) = 0.369 * X + 10.35 Kpa 1 0 0 CCP Off to On TPS Title: CCP Off to On TPS Location: 4032 Usage: CCP Parameters Tips: CCP = Charcoal Canister Purge. Conversion: % TPS = 0.390625 * X % TPS 1 0 0 CCP On to Off MPH Title: CCP On to Off MPH Location: 4033 Usage: CCP Parameters Tips: CCP = Charcoal Canister Purge. Conversion: MPH = 1 * X MPH 1 0 0 CCP On to Off MAP Title: CCP On to Off MAP Location: 4034 Usage: CCP Parameters Tips: CCP = Charcoal Canister Purge. Conversion: MAP (Kpa) = 0.369 * X + 10.35 Kpa 1 0 0 CCP On to Off TPS Title: CCP On to Off TPS Location: 4035 Usage: CCP Parameters Tips: CCP = Charcoal Canister Purge. Conversion: % TPS = 0.390625 * X % TPS 1 0 0 0 0 ==== CAT Overheat Protection Parameters =============== CAT Overheat Protection Parameters 0 0 0 0 CAT 1st Hysteresis Pair Upper Title: CAT 1st Hysteresis Pair Upper Location: 406D Usage: CAT Overheat Protection Parameters Tips: Must be enabled at L400F Bit 4. Conversion: High Temp (C) = 3 * X + 300.00 C 1 0 0 CAT 1st Hysteresis Pair Lower Title: CAT 1st Hysteresis Pair Lower Location: 406E Usage: CAT Overheat Protection Parameters Tips: Must be enabled at L400F Bit 4. Conversion: High Temp (C) = 3 * X + 300.00 C 1 0 0 CAT 2nd Hysteresis Pair Upper Title: CAT 2nd Hysteresis Pair Upper Location: 406F Usage: CAT Overheat Protection Parameters Tips: Must be enabled at L400F Bit 4. Conversion: High Temp (C) = 3 * X + 300.00 C 1 0 0 CAT 2nd Hysteresis Pair Lower Title: CAT 2nd Hysteresis Pair Lower Location: 4070 Usage: CAT Overheat Protection Parameters Tips: Must be enabled at L400F Bit 4. Conversion: High Temp (C) = 3 * X + 300.00 C 1 0 0 CAT Minimum CTS to use Default CAT Temperature Title: CAT Minimum CTS to use Default CAT Temperature Location: 4071 Usage: CAT Overheat Protection Parameters Tips: Must be enabled at L400F Bit 4. If CTS greater than L4071 use default temperature value at L4072. Conversion: Temp (C) = 0.750 * X + -40 C 1 0 0 CAT Default Temperature Title: CAT Default Temperature Location: 4072 Usage: CAT Overheat Protection Parameters Tips: Must be enabled at L400F Bit 4. If CTS greater than L4071 use default temperature value at L4072. Conversion: High Temp (C) = 3 * X + 300.00 C 1 0 0 CAT Time before use of L4088 Table Title: CAT Time before use of L4088 Table Location: 4073 Usage: CAT Overheat Protection Parameters Tips: Must be enabled at L400F Bit 4. Max time allowed for overheat before flagging overheat condition and using table at L4088 "CAT Endo/ Exothermic Reaction Temp vs. AFR". Conversion: Sec. = 1 * X Sec. 1 0 0 CAT Maximum TPS for Overheat Protection Title: CAT Maximum TPS for Overheat Protection Location: 4074 Usage: CAT Overheat Protection Parameters Tips: Must be enabled at L400F Bit 4. Disable overheat protection after time limit at L4076. Conversion: % TPS = 0.390625 * X % TPS 1 0 0 CAT Minimum RPM for Overheat Protection Title: CAT Minimum RPM for Overheat Protection Location: 4075 Usage: CAT Overheat Protection Parameters Tips: Must be enabled at L400F Bit 4. Disable overheat protection after time limit at L4076. Conversion: RPM = 25 * X RPM 0 0 0 CAT Hi TPS and Low RPM Disable Time Title: CAT Hi TPS and Low RPM Disable Time Location: 4076 Usage: CAT Overheat Protection Parameters Tips: Must be enabled at L400F Bit 4. Time limit for L4074 and L4075. Conversion: Sec. = 1 * X Sec. 1 0 0 0 0 ==== CPI Manifold Tuning Valve Parameters =============== CPI Manifold Tuning Valve Parameters 0 0 0 0 CPI On to Off Lower RPM Title: CPI On to Off Lower RPM Location: 412B Usage: CPI Manifold Tuning Valve Parameters Tips: CPI V6 with manifold tuning valve only. 400E Bit 3 "Variable Manifold Tuning Control" must be enabled, 400F Bit 2 "A/C Clutch Control/Variable Manifold Tune Control" and 400F Bit 0 "Governor Option" must be disabled. Conversion: RPM = 25 * X RPM 0 0 0 CPI Off to On Lower RPM Title: CPI Off to On Lower RPM Location: 412C Usage: CPI Manifold Tuning Valve Parameters Tips: CPI V6 with manifold tuning valve only. 400E Bit 3 "Variable Manifold Tuning Control" must be enabled, 400F Bit 2 "A/C Clutch Control/Variable Manifold Tune Control" and 400F Bit 0 "Governor Option" must be disabled. Conversion: RPM = 25 * X RPM 0 0 0 CPI On to Off Upper RPM Title: CPI On to Off Upper RPM Location: 412D Usage: CPI Manifold Tuning Valve Parameters Tips: CPI V6 with manifold tuning valve only. 400E Bit 3 "Variable Manifold Tuning Control" must be enabled, 400F Bit 2 "A/C Clutch Control/Variable Manifold Tune Control" and 400F Bit 0 "Governor Option" must be disabled. Conversion: RPM = 25 * X RPM 0 0 0 CPI Off to On Upper RPM Title: CPI Off to On Upper RPM Location: 412E Usage: CPI Manifold Tuning Valve Parameters Tips: CPI V6 with manifold tuning valve only. 400E Bit 3 "Variable Manifold Tuning Control" must be enabled, 400F Bit 2 "A/C Clutch Control/Variable Manifold Tune Control" and 400F Bit 0 "Governor Option" must be disabled. Conversion: RPM = 25 * X RPM 0 0 0 CPI On to Off TPS Title: CPI On to Off TPS Location: 412F Usage: CPI Manifold Tuning Valve Parameters Tips: CPI V6 with manifold tuning valve only. 400E Bit 3 "Variable Manifold Tuning Control" must be enabled, 400F Bit 2 "A/C Clutch Control/Variable Manifold Tune Control" and 400F Bit 0 "Governor Option" must be disabled. Conversion: % TPS = 0.390625 * X % TPS 1 0 0 CPI Off to On TPS Title: CPI Off to On TPS Location: 4130 Usage: CPI Manifold Tuning Valve Parameters Tips: CPI V6 with manifold tuning valve only. 400E Bit 3 "Variable Manifold Tuning Control" must be enabled, 400F Bit 2 "A/C Clutch Control/Variable Manifold Tune Control" and 400F Bit 0 "Governor Option" must be disabled. Conversion: % TPS = 0.390625 * X % TPS 1 0 0 CPI On Minimum Temperature Title: CPI On Minimum Temperature Location: 4131 Usage: CPI Manifold Tuning Valve Parameters Tips: CPI V6 with manifold tuning valve only. 400E Bit 3 "Variable Manifold Tuning Control" must be enabled, 400F Bit 2 "A/C Clutch Control/Variable Manifold Tune Control" and 400F Bit 0 "Governor Option" must be disabled. Conversion: Temp (C) = 0.750 * X + -40 C 1 0 0 0 0 ==== Spark/ DRP Parameters ======================= Spark/ DRP Parameters 0 0 0 0 Initial Spark Advance Title: Initial Spark Advance Location: 4132 Usage: Spark/ DRP Parameters Tips: Compensates for the spark advance added by mechanical means. This should be set to the same value that distributor is set to. Conversion: Spark (deg) = 0.351563 * X deg 1 0 0 Engine Running RPM Title: Engine Running RPM Location: 4133, 4134 Usage: Spark/ DRP Parameters Tips: Distributor reference pulse (DRP) threshold for engine to be considered running. Conversion: RPM = ((65536 * 120)/8)/X RPM 0 0 0 Crank to Run RPM Title: Crank to Run RPM Location: 4135, 4136 Usage: Spark/ DRP Parameters Tips: Distributor reference pulse (DRP) threshold to transition from crank to run fuel enable. Conversion: RPM = ((65536 * 120)/8)/X RPM 0 0 0 0 0 ==== MAP Filter Parameters ======================== MAP Filter Parameters 0 0 0 0 Standard MAP Filter Coefficient Title: Standard MAP Filter Coefficient Location: 4137 Usage: MAP Filter Parameters Tips: Conversion: % = 0.38823529 * X % 1 0 0 Transient MAP Filter Coefficient Title: Transient MAP Filter Coefficient Location: 4138 Usage: MAP Filter Parameters Tips: Conversion: % = 0.38823529 * X % 1 0 0 Transient MAP Apply Time Title: Transient MAP Apply Time Location: 4139 Usage: MAP Filter Parameters Tips: Conversion: Sec. = 0.0125 * X Sec 1 0 0 RPM Difference for Transient MAP Title: RPM Difference for Transient MAP Location: 413A Usage: MAP Filter Parameters Tips: Conversion: RPM = 12.5 * X RPM 0 0 0 0 0 ==== Spark Table Biases ========================== Spark Table Biases 0 0 0 0 Main Spark Bias Title: Main Spark Bias Location: 413B Usage: Spark Table Biases Tips: Allows PCM to generate a negative number if necessary. Subtracted from main spark tables. This value will be automatically accounted for in this xdf file, some xdf files do not. Conversion: Spark (deg) = 0.351563 * X deg 1 0 0 Coolant Spark Bias Title: Coolant Spark Bias Location: 413C Usage: Spark Table Biases Tips: Allows PCM to generate a negative number if necessary. Subtracted from coolant compensation spark table. This value will be automatically accounted for in this xdf file, some xdf files do not. Conversion: Spark (deg) = 0.351563 * X deg 1 0 0 Altitude Spark Bias Title: Altitude Spark Bias Location: 413D Usage: Spark Table Biases Tips: Allows PCM to generate a negative number if necessary. Adjusts spark advance for altitude. Subtracted from altitude compensation table. Used with back pressure EGR. This value will be automatically accounted for in this xdf file, some xdf files do not. Conversion: Spark (deg) = 0.351563 * X deg 1 0 0 EGR Spark Bias Title: EGR Spark Bias Location: 413E Usage: Spark Table Biases Tips: Allows PCM to generate a negative number if necessary. Subtracted from EGR Spark Correction table. This value will be automatically accounted for in this xdf file, some xdf files do not. Conversion: Spark (deg) = 0.351563 * X deg 1 0 0 MAT Spark Bias Title: MAT Spark Bias Location: 413F Usage: Spark Table Biases Tips: Allows PCM to generate a negative number if necessary. Subtracted from MAT Spark Compensation table. This value will be automatically accounted for in this xdf file, some xdf files do not. Conversion: Spark (deg) = 0.351563 * X deg 1 0 0 Minimum Temperature for Negative Spark Title: Minimum Temperature for Negative Spark Location: 4140 Usage: Spark Table Biases Tips: Conversion: Temp (C) = 0.750 * X + -40 C 1 0 0 Number of Cylinders Title: Number of Cylinders Location: 4141 Usage: Spark Table Biases Tips: Number of cylinders for the engine being used. Conversion: None Cylinders 2 1 0 0 Number of Counts for Run Flag Title: Number of Counts for Run Flag Location: 4142 Usage: Spark Table Biases Tips: Number of counts for run flag to be set if RPM greater than L4134 "Engine Running RPM". Conversion: None Counts 2 1 0 0 Number of DRP for Crank to Run Title: Number of DRP for Crank to Run Location: 4143 Usage: Spark Table Biases Tips: Number of distributor reference pulses to transition from crank to run. Conversion: None DRP 2 1 0 0 0 0 ==== Spark Advance and Retard Limits ================== Spark Advance and Retard Limits 0 0 0 0 Maximum Spark Advance Title: Maximum Spark Advance Location: 4144, 4145 Usage: Spark Advance and Retard Limits Tips: Limits spark advance to mechanical limits of ignition system. Traditional distributors should not exceed 42 degrees of advance. Conversion: Spark (deg) = 0.351563 * X Signed deg 1 0 0 Maximum Spark Retard Title: Maximum Spark Retard Location: 4146, 4147 Usage: Spark Advance and Retard Limits Tips: Limits the amount of total spark retard to a reasonable amount. Conversion: Spark (deg) = 0.351563 * X Signed deg 1 0 0 Maximum Spark Retard for DFCO Title: Maximum Spark Retard for DFCO Location: 4148, 4149 Usage: Spark Advance and Retard Limits Tips: Limits the amount of total spark retard when in DFCO to a reasonable amount. DFCO = Deceleration Fuel Cut-Off Conversion: Spark (deg) = 0.351563 * X Signed deg 1 0 0 Maximum Spark Retard for Torque Management Title: Maximum Spark Retard for Torque Management Location: 414A, 414B Usage: Spark Advance and Retard Limits Tips: Limits the amount of total spark retard during torque management fuel cutoff to a reasonable amount. Conversion: Spark (deg) = 0.351563 * X Signed deg 1 0 0 Crank to Run Spark Multiplier Coefficient Title: Crank to Run Spark Multiplier Coefficient Location: 414C Usage: Spark Advance and Retard Limits Tips: Conversion: Coefficient = 0.003906 * X Coeffficient 3 0 0 DFCO Low TPS Spark Multiplier Coefficient Title: DFCO Low TPS Spark Multiplier Coefficient Location: 414D Usage: Spark Advance and Retard Limits Tips: DFCO = Deceleration Fuel Cut-Off Conversion: Coefficient = 0.003906 * X Coefficient 3 0 0 DFCO High TPS Spark Multiplier Coefficient Title: DFCO High TPS Spark Multiplier Coefficient Location: 414E Usage: Spark Advance and Retard Limits Tips: DFCO = Deceleration Fuel Cut-Off Conversion: Coefficient = 0.003906 * X Coefficient 3 0 0 TPS to use DFCO High TPS Multiplier Title: TPS to use DFCO High TPS Multiplier Location: 414F Usage: Spark Advance and Retard Limits Tips: DFCO = Deceleration Fuel Cut-Off Conversion: % TPS = 0.390625 * X % TPS 1 0 0 Maximum DFCO Spark Advance Title: Maximum DFCO Spark Advance Location: 4150 Usage: Spark Advance and Retard Limits Tips: DFCO = Deceleration Fuel Cut-Off Conversion: Spark (deg) = 0.351563 * X deg 1 0 0 DFCO Spark RPM Filter Time Coefficient Title: DFCO Spark RPM Filter Time Coefficient Location: 4151 Usage: Spark Advance and Retard Limits Tips: DFCO = Deceleration Fuel Cut-Off Conversion: Coefficient = 0.003906 * X Coefficient 3 0 0 0 0 ==== Pseudo-Baro Parameters ====================== Pseudo-Baro Parameters 0 0 0 0 Maximum RPM for Baro Up-Date Title: Maximum RPM for Baro Up-Date Location: 4152 Usage: Pseudo-Baro Parameters Tips: Conversion: RPM = 25 * X RPM 0 0 0 Minimum RPM for Baro Up-Date Title: Minimum RPM for Baro Up-Date Location: 4153 Usage: Pseudo-Baro Parameters Tips: Conversion: RPM = 25 * X RPM 0 0 0 Minimum TPS for Baro Up-Date Title: Minimum TPS for Baro Up-Date Location: 4154 Usage: Pseudo-Baro Parameters Tips: Conversion: % TPS = 0.390625 * X % TPS 1 0 0 Minimum TPS Difference for Baro Up-Date Title: Minimum TPS Difference for Baro Up-Date Location: 4155 Usage: Pseudo-Baro Parameters Tips: Conversion: % TPS = 0.390625 * X % TPS 1 0 0 Baro A/D Filter Coefficient Title: Baro A/D Filter Coefficient Location: 4156 Usage: Pseudo-Baro Parameters Tips: Conversion: % = 0.3905555 * X % 1 0 0 Minimum Temperature for Baro Up-Date Title: Minimum Temperature for Baro Up-Date Location: 4157 Usage: Pseudo-Baro Parameters Tips: Conversion: Temp (C) = 0.750 * X + -40 C 1 0 0 0 0 ==== Idle Spark Advance ========================== Idle Spark Advance 0 0 0 0 Maximum MPH for Idle Spark Title: Maximum MPH for Idle Spark Location: 4158 Usage: Idle Spark Advance Tips: Maximum MPH for idle spark tables to be used. Overspeed/ underspeed idle corrections. This is in two locations!????? Conversion: MPH = 1 * X MPH 1 0 0 TPS to Return to Idle Spark Title: TPS to Return to Idle Spark Location: 4159 Usage: Idle Spark Advance Tips: TPS to return to idle spark from normal spark. Overspeed/ underspeed idle corrections. Conversion: % TPS = 0.390625 * X % TPS 1 0 0 Maximum TPS for Idle Spark Title: Maximum TPS for Idle Spark Location: 415A Usage: Idle Spark Advance Tips: Maximum TPS before switching to normal spark. Overspeed/ underspeed idle corrections. Conversion: % TPS = 0.390625 * X % TPS 1 0 0 Minimum Temperature for Idle Spark Title: Minimum Temperature for Idle Spark Location: 415B Usage: Idle Spark Advance Tips: Minimum temperature before using idle spark tables. Overspeed/ underspeed idle corrections. Conversion: Temp (C) = 0.750 * X + -40 C 1 0 0 Minimum Run Time for Idle Spark Title: Minimum Run Time for Idle Spark Location: 415C, 415D Usage: Idle Spark Advance Tips: Minimum run time before using idle spark tables. Overspeed/ underspeed idle corrections. Conversion: Sec. = 1 * X Sec. 1 0 0 RPM Offset Title: RPM Offset Location: 415E Usage: Idle Spark Advance Tips: Offset for desired RPM if not idling to check RPM qualifiers. For idle SA adjustments. Conversion: RPM = 25 * X RPM 0 0 0 0 0 ==== Power Steering Spark Compensation ================ Power Steering Spark Compensation 0 0 0 0 Temperature for P/S Spark Title: Temperature for P/S Spark Location: 415F Usage: Power Steering Spark Compensation Tips: P/S = Power Steering Conversion: Temp (C) = 0.750 * X + -40 C 1 0 0 Spark Advance for P/S Title: Spark Advance for P/S Location: 4160, 4161 Usage: Power Steering Spark Compensation Tips: P/S = Power Steering Conversion: Spark (deg) = 0.351563 * X deg 1 0 0 TPS for P/S Spark On Title: TPS for P/S Spark On Location: 4162 Usage: Power Steering Spark Compensation Tips: P/S = Power Steering Conversion: % TPS = 0.390625 * X % TPS 1 0 0 TPS for P/S Spark Off Title: TPS for P/S Spark Off Location: 4163 Usage: Power Steering Spark Compensation Tips: P/S = Power Steering Conversion: % TPS = 0.390625 * X % TPS 1 0 0 0 0 ==== Derivative Spark/ Fuel RPM Control Parameters ========= Derivative Spark/ Fuel RPM Control Parameters 0 0 Congratulations, you have discovered the hidden message. "PROM tuning is addictive" 0 0 Transient RPM Idle Spark Correction Bias Title: Transient RPM Idle Spark Correction Bias Location: 4512 Usage: Derivative Spark/ Fuel RPM Control Parameters Tips: Spark bias for table L4519 " Transient RPM Idle Spark Correction vs. RPM Ratio". Conversion: Spark (deg) = 0.351563 * X deg 1 0 0 Maximum Idle Spark Correction Title: Maximum Idle Spark Correction Location: 4513 Usage: Derivative Spark/ Fuel RPM Control Parameters Tips: Conversion: Spark (deg) = 0.351563 * X deg 1 0 0 Maximum RPM for Derivative Term Title: Maximum RPM for Derivative Term Location: 4514 Usage: Derivative Spark/ Fuel RPM Control Parameters Tips: Conversion: RPM = 25 * X RPM 0 0 0 Filter Coefficient, RPM/ 6.25 Title: Filter Coefficient, RPM/ 6.25 Location: 4515 Usage: Derivative Spark/ Fuel RPM Control Parameters Tips: Conversion: RPM = 25 * X RPM 0 0 0 Filter Coefficient, RPM Derivative Term Title: Filter Coefficient, RPM Derivative Term Location: 4516 Usage: Derivative Spark/ Fuel RPM Control Parameters Tips: Conversion: RPM = 25 * X RPM 0 0 0 Minimum Value for Transient RPM Ratio Title: Minimum Value for Transient RPM Ratio Location: 4517 Usage: Derivative Spark/ Fuel RPM Control Parameters Tips: Conversion: Value = 0.00782312295 * X Value 0 0 Maximum Value for Transient RPM Ratio Title: Maximum Value for Transient RPM Ratio Location: 4518 Usage: Derivative Spark/ Fuel RPM Control Parameters Tips: Conversion: Value = 0.00782312295 * X Value 0 0 0 0 ==== Low Octane Retard Parameters ================== Low Octane Retard Parameters 0 0 0 0 Minimum Temperature for Low Octane Retard Title: Minimum Temperature for Low Octane Retard Location: 45B4 Usage: Low Octane Retard Parameters Tips: Conversion: Temp (C) = 0.750 * X + -40 C 1 0 0 Minimum MAP for Low Octane Retard Title: Minimum MAP for Low Octane Retard Location: 45B5 Usage: Low Octane Retard Parameters Tips: Conversion: MAP (Kpa) = 0.369 * X + 10.35 Kpa 1 0 0 Maximum Rate of MAP Change for Low Octane Retard Title: Maximum Rate of MAP Change for Low Octane Retard Location: 45B6 Usage: Low Octane Retard Parameters Tips: Conversion: MAP (Kpa) = 0.369 * X + 10.35 Kpa 1 0 0 High Knock Activity Threshold Title: High Knock Activity Threshold Location: 45B7 Usage: Low Octane Retard Parameters Tips: Sets the amount of knock retard that will be considered as a high amount of knock activity. Conversion: Spark (deg) = 0.351563 * X deg 1 0 0 Low Knock Activity Threshold Title: Low Knock Activity Threshold Location:45B8 Usage: Low Octane Retard Parameters Tips: Sets the amount of knock retard that will be considered as a low amount of knock activity. Conversion: Spark (deg) = 0.351563 * X deg 1 0 0 Ramping Rate for adding Low Octane Retard Title: Ramping Rate for adding Low Octane Retard Location: 45B9 Usage: Low Octane Retard Parameters Tips: Conversion: Counts = 1 * X Counts 0 0 0 Ramping Rate for removing Low Octane Retard Title: Ramping Rate for removing Low Octane Retard Location: 45BA Usage: Low Octane Retard Parameters Tips: Conversion: Counts = 1 * X Counts 0 0 0 Base Low Octane Retard Title: Base Low Octane Retard Location: 45BB Usage: Low Octane Retard Parameters Tips: Conversion: Spark (deg) = 0.351563 * X deg 1 0 0 0 0 ==== Knock Retard Parameters ====================== Knock Retard Parameters 0 0 0 0 Minimum MPH for Knock Retard Title: Minimum MPH for Knock Retard Location: 45D6 Usage: Knock Retard Parameters Tips: Conversion: MPH = 1 * X MPH 0 0 0 Minimum RPM for Knock Retard Title: Minimum RPM for Knock Retard Location: 45D7 Usage: Knock Retard Parameters Tips: Conversion: RPM = 25 * X RPM 0 0 0 Minimum Temperature for Knock Retard Title: Minimum Temperature for Knock Retard Location: 45D8 Usage: Knock Retard Parameters Tips: Conversion: Temp (C) = 0.75 * X + -40 C 1 0 0 0 0 ==== Burst Knock Parameters ======================= Burst Knock Parameters 0 0 0 0 Maximum MAP for Burst Knock Retard Title: Maximum MAP for Burst Knock Retard Location: 46DD Usage: Burst Knock Parameters Tips: Conversion: MAP (Kpa) = 0.369 * X + 10.35 Kpa 1 0 0 Maximum TPS for Burst Knock Retard Title: Maximum TPS for Burst Knock Retard Location: 46DE Usage: Burst Knock Parameters Tips: Conversion: % TPS = 0.390625 * X % TPS 1 0 0 Minimum TPS for Burst Knock Retard Title: Minimum TPS for Burst Knock Retard Location: 46DF Usage: Burst Knock Parameters Tips: Conversion: % TPS = 0.390625 * X % TPS 1 0 0 Time for Burst Knock Retard Title: Time for Burst Knock Retard Location: 46E0 Usage: Burst Knock Parameters Tips: Conversion: msec. = 12.5 * X msec. 0 0 0 0 ==== Dynamic Spark Parameters ===================== Dynamic Spark Parameters 0 0 0 0 RPM RISING RPM RISING 0 0 Spark Advance Derivative Gain Title: Spark Advance Derivative Gain Location: 46EA Usage: Dynamic Spark Parameters Tips: Engine spark advance used with manual transmissions. Conversion: Spark (deg) = 0.351563 * X deg 1 0 0 Spark Advance Derivative Term Bias Title: Spark Advance Derivative Term Bias Location: 46EB Usage: Dynamic Spark Parameters Tips: Engine spark advance used with manual transmissions. Conversion: Spark (deg) = 0.351563 * X deg 1 0 0 Maximum Spark Advance to be Subtracted Title: Maximum Spark Advance to be Subtracted Location: 46EC Usage: Dynamic Spark Parameters Tips: Engine spark advance used with manual transmissions. Conversion: Spark (deg) = 0.351563 * X deg 1 0 0 0 0 RPM FALLING RPM FALLING 0 0 Spark Advance Derivative Gain Title: Spark Advance Derivative Gain Location: 46ED Usage: Dynamic Spark Parameters Tips: Engine spark advance used with manual transmissions. Conversion: Spark (deg) = 0.351563 * X deg 1 0 0 Spark Advance Derivative Term Bias Title: Spark Advance Derivative Term Bias Location: 46EE Usage: Dynamic Spark Parameters Tips: Engine spark advance used with manual transmissions. Conversion: Spark (deg) = 0.351563 * X deg 1 0 0 Maximum Spark Advance to be Added Title: Maximum Spark Advance to be Added Location: 46EF Usage: Dynamic Spark Parameters Tips: Engine spark advance used with manual transmissions. Conversion: Spark (deg) = 0.351563 * X deg 1 0 0 0 0 Temperature for Dynamic Spark Advance Off Title: Temperature for Dynamic Spark Advance Off Location: 46F0 Usage: Dynamic Spark Parameters Tips: Engine spark advance used with manual transmissions. Conversion: Temp (C) = 0.75 * X + -40 C 1 0 0 Temperature for Dynamic Spark Advance On Title: Temperature for Dynamic Spark Advance On Location: 46F1 Usage: Dynamic Spark Parameters Tips: Engine spark advance used with manual transmissions. Conversion: Temp (C) = 0.75 * X + -40 C 1 0 0 0 0 ==== EGR Enable Parameters ======================= EGR Enable Parameters 0 0 0 0 EGR Enable Startup Temperature Title: EGR Enable Startup Temperature Location: 46F7 Usage: EGR Enable Parameters Tips: Conversion: Temp (C) = 0.75 * X + -40 C 1 0 0 Temperature for EGR On Title: Temperature for EGR On Location: 46F8 Usage: EGR Enable Parameters Tips: Conversion: Temp (C) = 0.75 * X + -40 C 1 0 0 Temperature for EGR Off Title: Temperature for EGR Off Location: 46F9 Usage: EGR Enable Parameters Tips: Conversion: Temp (C) = 0.75 * X + -40 C 1 0 0 MAT for EGR On Title: MAT for EGR On Location: 46FA Usage: EGR Enable Parameters Tips: Conversion: Temp (C) = 0.75 * X + -40 C 1 0 0 MAT for EGR Off Title: MAT for EGR Off Location: 46FB Usage: EGR Enable Parameters Tips: Conversion: Temp (C) = 0.75 * X + -40 C 1 0 0 Minimum Speed for EGR Title: Minimum Speed for EGR Location: 46FC Usage: EGR Enable Parameters Tips: Conversion: MPH = 1 * X MPH 1 0 0 RPM for EGR On Title: RPM for EGR On Location: 46FD Usage: EGR Enable Parameters Tips: Conversion: RPM = 25 * X RPM 0 0 0 RPM for EGR Off Title: RPM for EGR Off Location: 46FE Usage: EGR Enable Parameters Tips: Conversion: RPM = 25 * X RPM 0 0 0 TPS for EGR On Title: TPS for EGR On Location: 46FF Usage: EGR Enable Parameters Tips: Conversion: % TPS = 0.390625 * X % TPS 1 0 0 TPS for EGR Off Title: TPS for EGR Off Location: 4700 Usage: EGR Enable Parameters Tips: Conversion: % TPS = 0.390625 * X % TPS 1 0 0 Lower MAP for EGR On Title: Lower MAP for EGR On Location: 4701 Usage: EGR Enable Parameters Tips: EGR MAP (lower window) enable/ disable thresholds. Conversion: MAP (Kpa) = 0.369 * X + 10.35 Kpa 1 0 0 Lower MAP for EGR Off Title: Lower MAP for EGR Off Location: 4702 Usage: EGR Enable Parameters Tips: EGR MAP (lower window) enable/ disable thresholds. Conversion: MAP (Kpa) = 0.369 * X + 10.35 Kpa 1 0 0 Upper MAP for EGR Off Title: Upper MAP for EGR Off Location: 4703 Usage: EGR Enable Parameters Tips: EGR MAP (upper window) enable/ disable thresholds. Conversion: MAP (Kpa) = 0.369 * X + 10.35 Kpa 1 0 0 Upper MAP for EGR On Title: Upper MAP for EGR On Location: 4704 Usage: EGR Enable Parameters Tips: EGR MAP (upper window) enable/ disable thresholds. Conversion: MAP (Kpa) = 0.369 * X + 10.35 Kpa 1 0 0 Maximum TPS for EGR Enable Title: Maximum TPS for EGR Enable Location: 4705 Usage: EGR Enable Parameters Tips: Conversion: % TPS = 0.390625 * X % TPS 1 0 0 Maximum AFR for EGR Enable Title: Maximum AFR for EGR Enable Location: 4706 Usage: EGR Enable Parameters Tips: Conversion: AFR = 0.100 * X AFR __ :1 1 0 0 Minimum Desired EGR Duty Cycle/Pintle Position Title: Minimum Desired EGR Duty Cycle/Pintle Position Location: 4707 Usage: EGR Enable Parameters Tips: EVRV/ Backpressure EGR = Duty Cycle. Liner EGR = Desired Pintle Position. 20% is the minimum allowed, if requested less than 20%, value will be 0%. Conversion: % = X / 2.56 % 1 0 0 EGR Flow Scalar Title: EGR Flow Scalar Location: 47E2 Usage: EGR Enable Parameters Tips: Used in calculation of EGR% flow. Linear and EVRV EGR only. Conversion: gms/Sec. = 1.953 * X ???? gms/Sec. 1 0 0 Minimum Linear EGR Position for EGR Flow Title: Minimum Linear EGR Position for EGR Flow Location: 4858 Usage: EGR Enable Parameters Tips: Linear EGR qualifiers for EGR flow. Conversion: % = X / 2.56 % 1 0 0 Minimum Time to Enable Linear EGR Title: Minimum Time to Enable Linear EGR Location: 4859, 485A Usage: EGR Enable Parameters Tips: Linear EGR qualifiers for EGR flow. Conversion: Sec. = 1 * X Sec. 1 0 0 Minimum Standard EGR % for EGR Flow Title: Minimum Standard EGR % for EGR Flow Location: 485B Usage: EGR Enable Parameters Tips: Standard EGR qualifiers for EGR flow. Conversion: % = X / 2.56 % 1 0 0 Standard EGR Spark Advance Filter Coefficient Title: Standard EGR Spark Advance Filter Coefficient Location: 485C Usage: EGR Enable Parameters Tips: Standard EGR qualifiers for EGR flow. Conversion: Coefficient = X / 256 Coefficient 3 0 0 A/D Value for EGR Pintle Position Scalar Title: A/D Value for EGR Pintle Position Scalar Location: 48A2 Usage: EGR Enable Parameters Tips: Digital EGR pintle position control calibration. Conversion: % = X / 2.56 % 1 0 0 Maximum Allowed Closed EGR Pintle Position Title: Maximum Allowed Closed EGR Pintle Position Location: 48A3 Usage: EGR Enable Parameters Tips: Digital EGR pintle position control calibration. Conversion: % = X / 2.56 % 1 0 0 Minimum Allowed Closed EGR Pintle Position Title: Minimum Allowed Closed EGR Pintle Position Location: 48A4 Usage: EGR Enable Parameters Tips: Digital EGR pintle position control calibration. Conversion: % = X / 2.56 % 1 0 0 Filter Coefficient for EGR Pintle Position Title: Filter Coefficient for EGR Pintle Position Location: 48A5 Usage: EGR Enable Parameters Tips: Digital EGR pintle position control calibration. Conversion: Coefficient = X / 256 Coefficient 3 0 0 Filter Coefficient for EGR % Title: Filter Coefficient for EGR % Location: 48A6 Usage: EGR Enable Parameters Tips: Digital EGR pintle position control calibration. Conversion: Coefficient = X / 256 Coefficient 3 0 0 0 0 ==== O2 Parameters ============================ O2 Parameters 0 0 0 0 Lower Limit for Slow Filtered O2 Title: Lower Limit for Slow Filtered O2 Location: 48B9 Usage: O2 Parameters Tips: Conversion: mVDC = .00434028 * X mVDC 3 0 0 Upper Limit for Slow Filtered O2 Title: Upper Limit for Slow Filtered O2 Location: 48BA Usage: O2 Parameters Tips: Conversion: mVDC = .00434028 * X mVDC 3 0 0 Slow O2 Filter Coefficient for Idle Title: Slow O2 Filter Coefficient for Idle Location: 48BB Usage: O2 Parameters Tips: Conversion: Coefficient = .00434028 * X Coefficient 3 0 0 O2 Initial Value Title: O2 Initial Value Location: 48BC Usage: O2 Parameters Tips: Conversion: mVDC = .00434028 * X mVDC 3 0 0 0 0 ==== MAP AE Parameters ========================= MAP AE Parameters 0 0 0 0 MAP Difference to Enable AE Title: MAP Difference to Enable AE Location: 48BD Usage: MAP AE Parameters Tips: Delta MAP threshold for AE. Conversion: MAP (Kpa) = 0.369 * X + 10.35 Kpa 1 0 0 MAP Difference to Enable AE at Idle Title: MAP Difference to Enable AE at Idle Location: 48BE Usage: MAP AE Parameters Tips: Delta MAP threshold for AE if idling. Conversion: MAP (Kpa) = 0.369 * X + 10.35 Kpa 1 0 0 TPS Threshold to Double Delta MAP AE Title: TPS Threshold to Double Delta MAP AE Location: 48BF Usage: MAP AE Parameters Tips: If TPS greater than setting, multiply 48BD "MAP Difference to Enable AE" and 48BE "MAP Difference to Enable AE at Idle" by 2. Conversion: % TPS = 0.390625 * X % TPS 1 0 0 TPS Threshold to Double MAP AE Title: TPS Threshold to Double MAP AE Location: 48C0 Usage: MAP AE Parameters Tips: If TPS greater than setting, multiply 4B48 "AE vs. MAP Difference" table value by 2. Conversion: % TPS = 0.390625 * X % TPS 1 0 0 0 0 ==== TPS AE Parameters ========================== TPS AE Parameters 0 0 0 0 TPS Difference to Enable AE Title: TPS Difference to Enable AE Location: 48C1 Usage: TPS AE Parameters Tips: TPS threshold for TPS AE. Conversion: % TPS = 0.390625 * X % TPS 1 0 0 TPS AE Off Idle Multiplier Title: TPS AE Off Idle Multiplier Location: 48C2 Usage: TPS AE Parameters Tips: Conversion: Multiplier = X / 128 Multiplier 0 0 MPH to Apply Off Idle Multiplier Title: MPH to Apply Off Idle Multiplier Location: 48C3 Usage: TPS AE Parameters Tips: Conversion: MPH = 1 * X MPH 1 0 0 0 0 ==== AE Parameters ============================ AE Parameters 0 0 0 0 Post DFCO AE Pulse Title: Post DFCO AE Pulse Location: 48C4 Usage: AE Parameters Tips: Provides a pulse of fuel after DFCO if no TPS increase. Conversion: msec. = .06103515625 * X msec. 3 0 0 A/C Off to On AE Title: A/C Off to On AE Location: 48C5 Usage: AE Parameters Tips: Provides AE when A/C is turned on. Conversion: msec. = .06103515625 * X msec. 1 0 0 Execution Time to Filter MAP/ TPS AE Title: Execution Time to Filter MAP/ TPS AE Location: 48C6 Usage: AE Parameters Tips: Conversion: Sec. = 0.1 * X Sec. 1 0 0 TPS Filter Coefficient Title: TPS Filter Coefficient Location: 48C7 Usage: AE Parameters Tips: Conversion: % TPS = 0.390625 * X % TPS 1 0 0 Integrator Locked Time after AE Title: Integrator Locked Time after AE Location: 48C8 Usage: AE Parameters Tips: Conversion: Sec. = 0.01 * X Sec. 3 0 0 0 0 ==== Closed Loop Qualifiers ======================== Closed Loop Qualifiers 0 0 0 0 (Cold) Temperature for Closed Loop Delay Timer Start Title: (Cold) Temperature for Closed Loop Delay Timer Start Location: 48C9 Usage: Closed Loop Qualifiers Tips: Temperature for timer at L48CB "(Warm) Minimum Time for Closed Loop" and L48CC "(Cold) Minimum Time for Closed Loop" to start. Conversion: Temp (C) = 0.75 * X + -40 C 1 0 0 (Hot) Temperature for Closed Loop Delay Timer Start Title: (Hot) Temperature for Closed Loop Delay Timer Start Location: 48CA Usage: Closed Loop Qualifiers Tips: Temperature for timer at L48CD "(Hot) Minimum Time for Closed Loop" to start. Conversion: Temp (C) = 0.75 * X + -40 C 1 0 0 (Warm) Minimum Time for Closed Loop Title: (Warm) Minimum Time for Closed Loop Location: 48CB Usage: Closed Loop Qualifiers Tips: Timer starts if temperature greater than L48C9 "(Cold) Temperature for Closed Loop Delay Timer Start". Conversion: Sec. = 2 * X Sec. 1 0 0 (Cold) Minimum Time for Closed Loop Title: (Cold) Minimum Time for Closed Loop Location: 48CC Usage: Closed Loop Qualifiers Tips: Timer starts if temperature greater than L48C9 "(Cold) Temperature for Closed Loop Delay Timer Start" . Conversion: Sec. = 2 * X Sec. 1 0 0 (Hot) Minimum Time for Closed Loop Title: (Hot) Minimum Time for Closed Loop Location: 48CD Usage: Closed Loop Qualifiers Tips: Timer starts if temperature greater than L48CA "(Hot) Temperature for Closed Loop Delay Timer Start". Conversion: Sec. = 2 * X Sec. 1 0 0 Minimum Temperature for Closed Loop Title: Minimum Temperature for Closed Loop Location: 48CE Usage: Closed Loop Qualifiers Tips: Temperature must be greater than setting before closed loop is entered. Conversion: Temp (C) = 0.75 * X + -40 C 1 0 0 Maximum Temperature for AFR Lookup in Closed Loop Title: Maximum Temperature for AFR Lookup in Closed Loop Location: 48CF Usage: Closed Loop Qualifiers Tips: If temperature less than setting, table at L4BBC "Open Loop AFR vs. Temperature vs. Vacuum" will be used for closed loop fueling instead of L48E5 "Stoichiometric AFR", but only if L400D Bit 0 "Open Loop AFR Enabled" is enabled. Conversion: Temp (C) = 0.75 * X + -40 C 1 0 0 0 0 ==== O2 Ready Parameter ========================= O2 Ready Parameter 0 0 Why does everything "time" related need a different "conversion factor"????? 0 0 Maximum Time for O2 to Dwell in Window Title: Maximum Time for O2 to Dwell in Window Location: 48D0 Usage: O2 Ready Parameter Tips: Minimum time for inside window for Not-Ready. Conversion: Sec. = 0.2 * X Sec. 1 0 0 0 0 ==== BLM Update Parameters ======================= BLM Update Parameters 0 0 0 0 Minimum Vacuum for BLM Update Title: Minimum Vacuum for BLM Update Location: 48D1 Usage: BLM Update Parameters Tips: Conversion: Kpa Vacuum = 0.08 * X ?? Kpa Vacuum 1 0 0 Minimum MAP for BLM Update Title: Minimum MAP for BLM Update Location: 48D2 Usage: BLM Update Parameters Tips: Conversion: MAP (Kpa) = 0.369 * X + 10.35 Kpa 1 0 0 Maximum MAP for BLM Update Title: Maximum MAP for BLM Update Location: 48D3 Usage: BLM Update Parameters Tips: Conversion: MAP (Kpa) = 0.369 * X + 10.35 Kpa 1 0 0 Minimum Temperature for BLM Update Enable Title: Minimum Temperature for BLM Update Enable Location: 48D4 Usage: BLM Update Parameters Tips: Conversion: Temp (C) = 0.75 * X + -40 C 1 0 0 Maximum RPM for BLM Update Enable Title: Maximum RPM for BLM Update Enable Location: 48D5 Usage: BLM Update Parameters Tips: Conversion: RPM = 25 * X RPM 0 0 0 0 0 ==== Idle Parameters ============================ Idle Parameters 0 0 0 0 Maximum MPH for Idle VE Title: Maximum MPH for Idle VE Location: 48D6 Usage: Idle Parameters Tips: If MPH less than setting, table at L4A89 "Idle VE Table" will be used. Conversion: MPH = 1 * X MPH 1 0 0 Maximum MPH for Idle Spark Table Title: Maximum MPH for Idle Spark Table Location: 48D7 Usage: Idle Parameters Tips: Maximum MPH for idle spark tables to be used. Overspeed/ underspeed idle corrections. This is in two locations!????? Conversion: MPH = 1 * X MPH 1 0 0 Maximum TPS for Idle VE Title: Maximum TPS for Idle VE Location: 48D8 Usage: Idle Parameters Tips: If TPS less than setting, table at L4A89 "Idle VE Table" will be used. Conversion: % TPS = 0.390625 * X % TPS 1 0 0 Maximum TPS for Derivative RPM Calculation Title: Maximum TPS for Derivative RPM Calculation Location: 48D9 Usage: Derivative Idle Control Tips: Conversion: % TPS = 0.390625 * X % TPS 1 0 0 Maximum MPH for Derivative RPM Calculation Title: Maximum MPH for Derivative RPM Calculation Location: 48DA Usage: Derivative Idle Control Tips: Conversion: MPH = 1 * X MPH 1 0 0 Minimum Temperature for Derivative RPM Calculation Title: Minimum Temperature for Derivative RPM Calculation Location: 48DB Usage: Derivative Idle Control Tips: Conversion: Temp (C) = 0.75 * X + -40 C 1 0 0 0 0 ==== Open Loop Qualifiers ========================= Open Loop Qualifiers 0 0 0 0 Open Loop Enable Timer Title: Open Loop Enable Timer Location: 48DC Usage: Open Loop Qualifiers Tips: If time greater than setting, enable open loop idle. Conversion: Sec. = 1 * X Sec. 1 0 0 Stay in Open Loop Timer Title: Stay in Open Loop Timer Location: 48DD Usage: Open Loop Qualifiers Tips: Timer threshold to remain in open loop idle. Conversion: Sec. = 1 * X Sec. 1 0 0 Clear Initial Idle Timer Title: Clear Initial Idle Timer Location: 48DE, 48DF Usage: Open Loop Qualifiers Tips: Time after startup to clear initial idle terms. Conversion: Sec. = 1 * X Sec. 1 0 0 Open Loop Idle Temperature Threshold Title: Open Loop Idle Temperature Threshold Location: 48E0 Usage: Open Loop Qualifiers Tips: Threshold to remain in open loop idle. Conversion: Temp (C) = 0.75 * X + -40 C 1 0 0 0 0 ==== Open Loop AFR Parameters ===================== Open Loop AFR Parameters 0 0 0 0 Temperature for Open Loop Idle AFR Bias Title: Temperature for Open Loop Idle AFR Bias Location: 48E1 Usage: Open Loop AFR Parameters Tips: Conversion: Temp (C) = 0.75 * X + -40 C 1 0 0 Lower Temperature for Open Loop Enrichment Title: Lower Temperature for Open Loop Enrichment Location: 48E2 Usage: Open Loop AFR Parameters Tips: Conversion: Temp (C) = 0.75 * X + -40 C 1 0 0 Upper Temperature for Open Loop Enrichment Title: Upper Temperature for Open Loop Enrichment Location: 48E3 Usage: Open Loop AFR Parameters Tips: Conversion: Temp (C) = 0.75 * X + -40 C 1 0 0 Timer for Idle Enrichment in Drive Title: Timer for Idle Enrichment in Drive Location: 48E4 Usage: Open Loop AFR Parameters Tips: Conversion: Sec. = .05 * X Sec. 1 0 0 Stoichiometric AFR Title: Stoichiometric AFR Location: 48E5 Usage: Open Loop AFR Parameters Tips: Used if temperature greater than L48CE "Minimum Temperature for Closed Loop". Used if temperature greater than L48CF "Maximum Temperature for AFR Lookup in Closed Loop" if L400D Bit 0 "Open Loop AFR Enabled" is enabled. Conversion: AFR (__:1) = 0.1 * X __:1 1 0 0 Open Loop AFR Bias Title: Open Loop AFR Bias Location: 48E6 Usage: Open Loop AFR Parameters Tips: Used prior to TPS action after start up. Conversion: AFR (__:1) = 0.1 * X __:1 1 0 0 Quasi- Closed Loop Lower AFR Limit Title: Quasi- Closed Loop Lower AFR Limit Location: 48E7 Usage: Open Loop AFR Parameters Tips: Conversion: AFR (__:1) = 0.1 * X __:1 1 0 0 Initial AFR Enrichment in Drive Title: Initial AFR Enrichment in Drive Location: 48E8 Usage: Open Loop AFR Parameters Tips: Conversion: AFR (__:1) = 0.1 * X __:1 1 0 0 Initial AFR Enrichment in Park/ Neutral Title: Initial AFR Enrichment in Park/ Neutral Location: 48E9 Usage: Open Loop AFR Parameters Tips: Conversion: AFR (__:1) = 0.1 * X __:1 1 0 0 Filter Coefficient for Idle Transition Title: Filter Coefficient for Idle Transition Location: 48EA Usage: Open Loop AFR Parameters Tips: Conversion: % = 0.3905555 * X % 1 0 0 0 0 ==== BLM Parameters ============================ BLM Parameters 0 0 0 0 Minimum Time to Update BLM Title: Minimum Time to Update BLM Location: 48EB Usage: BLM Parameters Tips: Conversion: msec. = 50 * X + 50 msec. 0 0 0 RPM Hysteresis to Change BLM Cells Title: RPM Hysteresis to Change BLM Cells Location: 48F2 Usage: BLM Parameters Tips: Conversion: RPM = 25 * X RPM 0 0 0 SD MAP Hysteresis to Change BLM Cells Title: SD MAP Hysteresis to Change BLM Cells Location: 48F3 Usage: BLM Parameters Tips: Conversion: Kpa = 0.369 * X Kpa 1 0 0 Delta Integrator Threshold to Update BLM Title: Delta Integrator Threshold to Update BLM Location: 48F5 Usage: BLM Parameters Tips: Conversion: INT = 1 * X INT 0 0 0 Integrator Threshold to Bar Open Loop Idle Title: Delta Integrator Threshold to Bar Open Loop Idle Location: 48F6 Usage: BLM Parameters Tips: Conversion: INT = 1 * X INT 0 0 0 Minimum BLM Title: Minimum BLM Location: 48F7 Usage: BLM Parameters Tips: Conversion: BLM = 1 * X BLM 0 0 0 Minimum BLM at Idle Title: Minimum BLM at Idle Location: 48F8 Usage: BLM Parameters Tips: Conversion: BLM = 1 * X BLM 0 0 0 BLM Step Value Title: BLM Step Value Location: 48F9 Usage: BLM Parameters Tips: Conversion: BLM = 1 * X BLM 0 0 0 Maximum BLM Title: Maximum BLM Location: 48FA Usage: BLM Parameters Tips: Conversion: BLM = 1 * X BLM 0 0 0 Maximum Initial BLM Title: Maximum Initial BLM Location: 48FB Usage: BLM Parameters Tips: Resets out of bounds BLM upon cell change. ?? Conversion: BLM = 1 * X BLM 0 0 0 Minimum Initial BLM Title: Minimum Initial BLM Location: 48FC Usage: BLM Parameters Tips: Resets out of bounds BLM upon cell change. ?? Conversion: BLM = 1 * X BLM 0 0 0 0 0 ==== Integrator Anti-Windup Parameters ================ Integrator Anti-Windup Parameters 0 0 0 0 Lower Integrator Threshold Title: Lower Integrator Threshold Location: 4905 Usage: Integrator Anti-Windup Parameters Tips: Parameters to set BLM cell change and cause integrator reset. Lower integrator threshold to flag BLM cell change when BLM rising. Conversion: INT = 1 * X INT 0 0 0 Upper Integrator Threshold Title: Upper Integrator Threshold Location: 4906 Usage: Integrator Anti-Windup Parameters Tips: Parameters to set BLM cell change and cause integrator reset. Upper integrator threshold to flag BLM cell change when BLM falling. Conversion: INT = 1 * X INT 0 0 0 Leaner Delta BLM Threshold Title: Leaner Delta BLM Threshold Location: 4907 Usage: Integrator Anti-Windup Parameters Tips: Parameters to set BLM cell change and cause integrator reset. Delta BLM threshold to clear BLM cell change if going leaner. Conversion: BLM = 1 * X BLM Difference 0 0 0 Richer Delta BLM Threshold Title: Richer Delta BLM Threshold Location: 4908 Usage: Integrator Anti-Windup Parameters Tips: Parameters to set BLM cell change and cause integrator reset. Delta BLM threshold to clear BLM cell change if going richer. Conversion: BLM = 1 * X BLM Difference 0 0 0 Lower MAP Threshold for INT Reset Title: Lower MAP Threshold for INT Reset Location: 4909 Usage: Integrator Anti-Windup Parameters Tips: Parameters to set BLM cell change and cause integrator reset. Conversion: MAP (Kpa) = 0.369 * X + 10.35 Kpa 1 0 0 Lower Threshold not to Reset INT Title: Lower Threshold not to Reset INT Location: 490A Usage: Integrator Anti-Windup Parameters Tips: Parameters to set BLM cell change and cause integrator reset. Conversion: RPM = 25 * X RPM 0 0 0 Upper Threshold not to Reset INT Title: Upper Threshold not to Reset INT Location: 490B Usage: Integrator Anti-Windup Parameters Tips: Parameters to set BLM cell change and cause integrator reset. Conversion: RPM = 25 * X RPM 0 0 0 Speed Threshold to Reset INT Title: Speed Threshold to Reset INT Location: 490C Usage: Integrator Anti-Windup Parameters Tips: Parameters to set BLM cell change and cause integrator reset. Conversion: MPH = 1 * X MPH 1 0 0 VE Table Change INT Threshold Title: VE Table Change INT Threshold Location: 490D Usage: Integrator Anti-Windup Parameters Tips: Parameters to set BLM cell change and cause integrator reset. Integrator threshold to reset integrator on VE table change, Conversion: INT = 1 * X INT 0 0 0 0 0 ==== Integrator Parameters ======================== Integrator Parameters 0 0 0 0 Minimum Integrator Title: Minimum Integrator Location: 490E Usage: Integrator Parameters Tips: Conversion: INT = 1 * X INT 0 0 0 Maximum Integrator Title: Maximum Integrator Location: 490F Usage: Integrator Parameters Tips: Conversion: INT = 1 * X INT 0 0 0 Integrator Proportional Term Limit Title: Integrator Proportional Term Limit Location: 4910 Usage: Integrator Parameters Tips: Proportional term limit when AE in effect. Conversion: INT = 1 * X INT Limit 0 0 0 Lean AFR Limit Title: Lean AFR Limit Location: 4911 Usage: Integrator Parameters Tips: Conversion: AFR = 0.100 * X __:1 1 0 0 0 0 ==== Power Enrichment Parameters =================== Power Enrichment Parameters 0 0 0 0 RPM Difference to Bypass PE Delay Title: RPM Difference to Bypass PE Delay Location: 4912 Usage: Power Enrichment Parameters Tips: If RPM quickly increases more than setting, PE delay is bypassed Conversion: RPM = 12.5 * X RPM 0 0 0 Lower Temperature to Bypass PE Delay Title: Lower Temperature to Bypass PE Delay Location: 4913 Usage: Power Enrichment Parameters Tips: If temperature less than setting, PE delay will be bypassed. Conversion: Temp (C) = 0.75 * X + -40 C 1 0 0 Upper Temperature to Bypass PE Delay Title: Upper Temperature to Bypass PE Delay Location: 4914 Usage: Power Enrichment Parameters Tips: If temperature greater than setting, PE delay will be bypassed. Conversion: Temp (C) = 0.75 * X + -40 C 1 0 0 Minimum TPS for PE Title: Minimum TPS for PE Location: 4915 Usage: Power Enrichment Parameters Tips: Conversion: % TPS = 0.390625 * X % TPS 1 0 0 RPM to Bypass PE Delay Title: RPM to Bypass PE Delay Location: 4916 Usage: Power Enrichment Parameters Tips: If RPM greater than setting, bypass PE delay. Conversion: RPM = 25 * X RPM 0 0 0 PE Delay Time Title: PE Delay Time Location: 4917 Usage: Power Enrichment Parameters Tips: Time delay for Power Enrichment. Conversion: Sec. = 1 * X Sec. 1 0 0 PE Slew Rate Title: PE Slew Rate Location: 4918 Usage: Power Enrichment Parameters Tips: Delay for PE to become active. Conversion: msec. = 12.5 * X msec. 0 0 PE Slew Multiplier Title: PE Slew Multiplier Location: 4919 Usage: Power Enrichment Parameters Tips: PE ramping rate. Conversion: % = 0.3905555 * X % 1 0 0 Minimum Temperature for PE Title: Minimum Temperature for PE Location: 491A Usage: Power Enrichment Parameters Tips: If temperature less than setting, PE will be disabled. Conversion: Temp (C) = 0.75 * X + -40 C 1 0 0 Time for Extended PE Title: Time for Extended PE Location: 491B Usage: Power Enrichment Parameters Tips: If in PE longer than setting, disable PE entrance ramp. Conversion: Sec. = 1 * X Sec. 1 0 0 Maximum Temperature for PE Title: Maximum Temperature for PE Location: 491C Usage: Power Enrichment Parameters Tips: If temperature greater than setting, PE will be disabled. Conversion: Temp (C) = 0.75 * X + -40 C 1 0 0 Minimum RPM for Cold PE Title: Minimum RPM for Cold PE Location: 491D Usage: Power Enrichment Parameters Tips: See L4922 " Added AFR when Cold PE". Conversion: RPM = 25 * X RPM 0 0 0 Minimum MPH for Cold PE Title: Minimum MPH for Cold PE Location: 491E Usage: Power Enrichment Parameters Tips: See L4922 " Added AFR when Cold PE". Conversion: MPH = 1 * X MPH 1 0 0 Minimum MPH for Fast PE Title: Minimum MPH for Fast PE Location: 491F Usage: Power Enrichment Parameters Tips: Fast PE = Entering PE with no delay time. Conversion: MPH = 1 * X MPH 1 0 0 Minimum TPS for Fast PE Title: Minimum TPS for Fast PE Location: 4920 Usage: Power Enrichment Parameters Tips: Fast PE = Entering PE with no delay time. Conversion: % TPS = 0.390625 * X % TPS 1 0 0 Minimum Time for Fast PE Title: Minimum Time for Fast PE Location: 4921 Usage: Power Enrichment Parameters Tips: Fast PE = Entering PE with no delay time. Conversion: Sec. = 1 * X Sec. 1 0 0 Added AFR when Cold PE Title: Added AFR when Cold PE Location: 4922 Usage: Power Enrichment Parameters Tips: Added to Base PE AFR and to PE table settings when engine is cold. ?? Conversion: AFR = 0.100 * X __:1 1 0 0 Base PE AFR Title: Base PE AFR Location: 4923 Usage: Power Enrichment Parameters Tips: AFR adjustment if in PE ramp mode. Conversion: AFR = 0.100 * X __:1 1 0 0 Minimum MPH for PE Title: Minimum MPH for PE Location: 4924, 4925 Usage: Power Enrichment Parameters Tips: PE disabled if MPH less than setting. Conversion: MPH = 1 * X MPH 1 0 0 0 0 ==== Choke AFR Parameters ======================= Choke AFR Parameters 0 0 0 0 Choke AFR Decay Multiplier Title: Choke AFR Decay Multiplier Location: 4926 Usage: Choke AFR Parameters Tips: Conversion: % = 0.390625 * X % 1 0 0 Time Before Choke AFR Decay Title: Time Before Choke AFR Decay Location: 4927 Usage: Choke AFR Parameters Tips: Time after startup to decay choke AFR. Conversion: Sec. = 0.2 * X Sec. 1 0 0 0 0 ==== Asynchronous/ Synchronous BPW Parameters ========== Asynchronous/ Synchronous BPW Parameters 0 0 0 0 Minimum Async to Sync BPW Title: Minimum Async to Sync BPW Location: 4928, 4929 Usage: Asynchronous and Synchronous BPW Parameters Tips: Asynchronous to Synchronous if BPW greater than setting. If CPI/ PFI then single fire to double fire. Conversion: uSec. = 15.2587890 * X uSec. 1 0 0 Minimum Sync to Async BPW Title: Minimum Sync to Async BPW Location: 492A, 492B Usage: Asynchronous and Synchronous BPW Parameters Tips: Synchronous to Asynchronous if BPW less than or equal to setting. If CPI/ PFI then double fire to single fire. Conversion: uSec. = 15.2587890 * X uSec. 1 0 0 Async to Sync Fuel MAP Threshold Title: Async to Sync Fuel MAP Threshold Location: 492C Usage: Asynchronous and Synchronous BPW Parameters Tips: MAP threshold to transition back to sync fire if MAP less than or equal to setting. TBI only. Conversion: MAP (Kpa) = 0.369 * X + 10.35 Kpa 1 0 0 Async to Sync Fuel RPM Threshold Title: Async to Sync Fuel RPM Threshold Location: 492D Usage: Asynchronous and Synchronous BPW Parameters Tips: RPM threshold to transition back to sync fire if RPM less than or equal to setting. TBI only. Conversion: RPM = 25 * X RPM 0 0 0 Sync to Async Fuel MAP Threshold Title: Sync to Async Fuel MAP Threshold Location: 492E Usage: Asynchronous and Synchronous BPW Parameters Tips: MAP threshold to enter async fire if MAP greater than setting. TBI only. Conversion: MAP (Kpa) = 0.369 * X + 10.35 Kpa 1 0 0 Sync to Async Fuel RPM Threshold Title: Sync to Async Fuel RPM Threshold Location: 492F Usage: Asynchronous and Synchronous BPW Parameters Tips: RPM threshold to enter async fire if RPM greater than setting. TBI only. Conversion: RPM = 25 * X RPM 0 0 0 Maximum Async BPW Title: Maximum Async BPW Location: 4930, 4931 Usage: Asynchronous and Synchronous BPW Parameters Tips: Maximum async BPW per pass. Conversion: msec. = .0152587890 * X msec. 1 0 0 Minimum Async BPW Title: Minimum Async BPW Location: 4932, 4933 Usage: Asynchronous and Synchronous BPW Parameters Tips: Minimum async BPW per pass. Conversion: uSec. = 15.2587890 * X uSec. 1 0 0 0 0 ==== Deceleration Enleanment Parameters =============== Deceleration Enleanment Parameters 0 0 0 0 TPS for Deceleration Enleanment Title: TPS for Deceleration Enleanment Location: 4934 Usage: Deceleration Enleanment Parameters Tips: Amount of negative TPS difference for deceleration enleanment to be engaged. Conversion: - % TPS = 0.390625 * X - % TPS 1 0 0 MAP for Deceleration Enleanment Title: MAP for Deceleration Enleanment Location: 4935 Usage: Deceleration Enleanment Parameters Tips: Amount of negative MAP difference for deceleration enleanment to be engaged. Conversion: MAP (Kpa) = 0.369 * X + 10.35 - Kpa 1 0 0 Deceleration Enleanment Multiplier Title: Deceleration Enleanment Multiplier Location: 4936 Usage: Deceleration Enleanment Parameters Tips: Multiplier for low speed deceleration enleanment. Conversion: Multiplier % = 0.390625 * X % 1 0 0 MPH for Deceleration Enleanment Title: MPH for Deceleration Enleanment Location: 4937 Usage: Deceleration Enleanment Parameters Tips: MPH threshold for low speed deceleration enleanment. Conversion: MPH = 1 * X MPH 1 0 0 0 0 ==== Deceleration Fuel Cut-Off Parameters =============== Deceleration Fuel Cut-Off Parameters 0 0 0 0 DFCO RPM Hysteresis Title: DFCO RPM Hysteresis Location: 4938 Usage: Deceleration Fuel Cut-Off Parameters Tips: Conversion: RPM = 25 * X RPM 0 0 0 Minimum MPH to Enter DFCO Title: Minimum MPH to Enter DFCO Location: 4939 Usage: Deceleration Fuel Cut-Off Parameters Tips: Lowest MPH that DFCO can be initiated. Conversion: MPH = 1 * X MPH 1 0 0 MPH to Disable DFCO Title: MPH to Disable DFCO Location: 493A Usage: Deceleration Fuel Cut-Off Parameters Tips: DFCO will be disable if MPH drops below setting. Conversion: MPH = 1 * X MPH 1 0 0 MAP Threshold for Mandatory DFCO Title: MAP Threshold for Mandatory DFCO Location: 493B Usage: Deceleration Fuel Cut-Off Parameters Tips: Lower MAP kpa at which DFCO is mandatory. Conversion: MAP (Kpa) = 0.369 * X + 10.35 Kpa 1 0 0 Maximum MAP for DFCO Title: Maximum MAP for DFCO Location: 493C Usage: Deceleration Fuel Cut-Off Parameters Tips: Upper MAP limit for DFCO. Conversion: MAP (Kpa) = 0.369 * X + 10.35 Kpa 1 0 0 DFCO Additional AE Title: DFCO Additional AE Location: 493D, 493E Usage: Deceleration Fuel Cut-Off Parameters Tips: Provides additional AE when exiting DFCO. Conversion: msec. = .0152587890 * X msec. 0 0 Minimum Time before DFCO Title: Minimum Time before DFCO Location: 493F Usage: Deceleration Fuel Cut-Off Parameters Tips: Qualifications for DFCO must be met for minimum time specified. Conversion: Sec. = 0.1 * X Sec. 1 0 0 Maximum Time for Additional AE Title: Maximum Time for Additional AE Location: 4940 Usage: Deceleration Fuel Cut-Off Parameters Tips: Maximum Time after exiting DFCO to sustain additional AE specified at L493D "DFCO Additional AE". Conversion: msec. = 12.5 * X msec. 0 0 0 Decay Rate for DFCO Multiplier Title: Decay Rate for DFCO Multiplier Location: 4941 Usage: Deceleration Fuel Cut-Off Parameters Tips: % per 12.5 msec. Conversion: % = X / 2.56 % per 12.5 msec. 1 0 0 Minimum Temperature for DFCO Title: Minimum Temperature for DFCO Location: 4942 Usage: Deceleration Fuel Cut-Off Parameters Tips: If temperature less than setting DFCO will be disabled. Conversion: Temp (C) = 0.75 * X + -40 C 1 0 0 RPM Drop before DFCO Disabled Title: RPM Drop before DFCO Disabled Location: 4943 Usage: Deceleration Fuel Cut-Off Parameters Tips: Amount of RPM difference allowed before DFCO is disabled. Conversion: RPM = 12.5 * X RPM 0 0 0 MAP Drop before DFCO Disabled Title: MAP Drop before DFCO Disabled Location: 4944 Usage: Deceleration Fuel Cut-Off Parameters Tips: Amount of MAP difference allowed before DFCO is disabled. Conversion: MAP (Kpa) = 0.315 * X ?? Kpa 1 0 0 0 0 ==== Idle O2 Parameters ========================== Idle O2 Parameters 0 0 0 0 O2 mV Hysteresis for Rich/Lean Title: O2 mV Hysteresis for Rich/Lean Location: 4945 Usage: Idle O2 Parameters Tips: Conversion: mVDC = 4.340280 * X mVDC 0 0 0 Minimum Slow O2 Error to Update INT Title: Minimum Slow O2 Error to Update INT Location: 4946 Usage: Idle O2 Parameters Tips: Conversion: Counts = 1 * X Counts 0 0 0 PID Table Airflow Scalar Title: PID Table Airflow Scalar Location: 4947 Usage: Idle O2 Parameters Tips: Scalar for airflow used in PID tables. Conversion: Scalar = X / 65.536 Scalar 0 0 Rich Idle O2 Voltage Threshold Title: Rich Idle O2 Voltage Threshold Location: 4948 Usage: Idle O2 Parameters Tips: Conversion: mVDC = 4.340280 * X mVDC 0 0 0 Lean Idle O2 Voltage Threshold Title: Lean Idle O2 Voltage Threshold Location: 4949 Usage: Idle O2 Parameters Tips: Conversion: mVDC = 4.340280 * X mVDC 0 0 0 Mean Rich/ Lean Idle O2 Voltage Threshold Title: Mean Rich/ Lean Idle O2 Voltage Threshold Location: 494A Usage: Idle O2 Parameters Tips: Conversion: mVDC = 4.340280 * X mVDC 0 0 0 Proportional Duration Offset at Idle Title: Proportional Duration Offset at Idle Location: 494B Usage: Idle O2 Parameters Tips: Used for idle, instead of table L4D26 "Proportional Duration Offset vs. Airflow". Conversion: msec. = 25 * X msec. 0 0 0 Proportional Duration Dead Band Title: Proportional Duration Dead Band Location: 494C Usage: Idle O2 Parameters Tips: Conversion: msec. = 25 * X msec. 0 0 0 0 0 ==== O2 PID Idle Parameters ======================= O2 PID Idle Parameters 0 0 0 0 PROPORTIONAL GAINS IF UNSTABLE IDLE PRESENT PROPORTIONAL GAINS IF UNSTABLE IDLE PRESENT 0 0 Proportional Gain if Rich (Unstable) Title: Proportional Gain if Rich (Unstable) Location: 494D Usage: O2 PID Idle Parameters Tips: Conversion: Gain = X / 256 Gain 3 0 0 Proportional Gain if Lean (Unstable) Title: Proportional Gain if Lean (Unstable) Location: 494E Usage: O2 PID Idle Parameters Tips: Conversion: Gain = X / 256 Gain 3 0 0 0 0 PROPORTIONAL GAINS IF STABLE IDLE PRESENT PROPORTIONAL GAINS IF STABLE IDLE PRESENT 0 0 Proportional Gain if Rich (Stable) Title: Proportional Gain if Rich (Stable) Location: 494F Usage: O2 PID Idle Parameters Tips: Conversion: Gain = X / 256 Gain 3 0 0 Proportional Gain if Lean (Stable) Title: Proportional Gain if Lean (Stable) Location: 4950 Usage: O2 PID Idle Parameters Tips: Also indexed for integrator delay term. Conversion: Gain = X / 256 Gain 3 0 0 0 0 Integrator Delay for Stable Idle Title: Integrator Delay for Stable Idle Location: 4951 Usage: O2 PID Idle Parameters Tips: Conversion: msec. = 25 * X msec 0 0 0 Delta RPM Threshold for Unstable Idle Title: Delta RPM Threshold for Unstable Idle Location: 4952 Usage: O2 PID Idle Parameters Tips: Conversion: RPM = 12.500000 * X RPM 0 0 0 Factor Applied to O2 Error if Going Richer Title: Factor Applied to O2 Error if Going Richer Location: 4953 Usage: O2 PID Idle Parameters Tips: Conversion: Factor = X / 256 Factor 3 0 0 Factor Applied to O2 Error if Idling Title: Factor Applied to O2 Error if Idling Location: 4954 Usage: O2 PID Idle Parameters Tips: Conversion: Factor = X / 256 Factor 3 0 0 0 0 ==== Choke Park to Drive AFR Parameters =============== Choke Park to Drive AFR Parameters 0 0 0 0 Upper Temperature for Park to Drive AFR Title: Upper Temperature for Park to Drive AFR Location: 4955 Usage: Choke Park to Drive AFR Parameters Tips: Maximum temperature for AFR to be increased while transitioning from park to drive when engine is cold. Conversion: Temp (C) = 0.750000 * X + -40 C 1 0 0 Park to Drive AFR Limit Title: Park to Drive AFR Limit Location: 4956 Usage: Choke Park to Drive AFR Parameters Tips: Limits the amount of AFR increase while transitioning from park to drive when engine is cold. Conversion: AFR = 0.100 * X __:1 1 0 0 Time for Park to Drive AFR Title: Time for Park to Drive AFR Location: 4957 Usage: Choke Park to Drive AFR Parameters Tips: Time for park to drive AFR to remain in affect. Conversion: Sec. = 0.2 * X Sec. 1 0 0 0 0 ==== Hot Restart Parameters ======================= Hot Restart Parameters 0 0 0 0 Minimum Previous Temperature for Hot Restart Title: Minimum Previous Temperature for Hot Restart Location: 4958 Usage: Hot Restart Parameters Tips: Minimum previous shutdown temp to enable hot restart parameters. Conversion: Temp (C) = 0.750000 * X + -40 C 1 0 0 Minimum Temperature for Hot Restart Title: Minimum Temperature for Hot Restart Location: 4959 Usage: Hot Restart Parameters Tips: Conversion: Temp (C) = 0.750000 * X + -40 C 1 0 0 AFR for Hot Restart Title: AFR for Hot Restart Location: 495A Usage: Hot Restart Parameters Tips: Amount of AFR increase during hot restart. Conversion: AFR = 0.100 * X __:1 1 0 0 Minimum Time for Hot Restart Title: Minimum Time for Hot Restart Location: 495B, 495C Usage: Hot Restart Parameters Tips: Minimum time to clear hot restart status. Conversion: Sec. = 1.0 * X Sec. 1 0 0 0 0 ==== Crank to Run Transition Parameters ================ Crank to Run Transition Parameters 0 0 0 0 DRP Before Crank to Run Transition Title: DRP Before Crank to Run Transition Location: 495D Usage: Crank to Run Transition Parameters Tips: Number of Distributor Reference Pulses before crank to run transition. Conversion: DRP = 1 * X DRP 0 0 0 Crank 2nd Injector Firing BPW Multiplier Title: Crank 2nd Injector Firing BPW Multiplier Location: 495E Usage: Crank to Run Transition Parameters Tips: Conversion: Multiplier = X / 128 Multiplier 3 0 0 Temperature for Transition AFR Added Title: Temperature for Transition AFR Added Location: 495F Usage: Crank to Run Transition Parameters Tips: Threshold to add AFR transition ratio in. Conversion: Temp (C) = 0.750000 * X + -40 C 1 0 0 Maximum Time for Fuel Pump Running with No DRP Title: Maximum Time for Fuel Pump Running with No DRP Location: 4960, 4961 Usage: Crank to Run Transition Parameters Tips: Conversion: Sec. = 0.0125 * X Sec. 1 0 0 DRP between Crank to Run Routines Title: DRP between Crank to Run Routines Location: 4962 Usage: Crank to Run Transition Parameters Tips: Number of DRP between each execution of crank to run transition routine. Conversion: DRP = 1 * X DRP 0 0 0 0 0 ==== Speed and RPM Limiter Parameters ================ Speed and RPM Limiter Parameters 0 0 0 0 Time Delay for High Speed Fuel Cut Off Title: Time Delay for High Speed Fuel Cut Off Location: 4963 Usage: Speed and RPM Limiter Parameters Tips: Delays activation of fuel cut off when speed limit is exceeded. Conversion: Sec. = 0.0125 * X Sec. 1 0 0 Fuel Resume RPM after MPH Overspeed Title: Fuel Resume RPM after MPH Overspeed Location: 4964 Usage: Speed and RPM Limiter Parameters Tips: If RPM drops to setting after MPH limit has been exceeded fueling will resume. Conversion: RPM = 25.000000 * X RPM 0 0 0 RPM to Enter Fuel Cut Off Title: RPM to Enter Fuel Cut Off Location: 4965 Usage: Speed and RPM Limiter Parameters Tips: Rev limiter on RPM. Conversion: RPM = 25.000000 * X RPM 0 0 0 RPM to Resume Fueling Title: RPM to Resume Fueling Location: 4966 Usage: Speed and RPM Limiter Parameters Tips: Rev limiter on RPM. Conversion: RPM = 25.000000 * X RPM 0 0 0 RPM to Enter Fuel Cut Off if Transmission Error Title: RPM to Enter Fuel Cut Off if Transmission Error Location: 4967 Usage: Speed and RPM Limiter Parameters Tips: Rev limiter on RPM if transmission error. Conversion: RPM = 25.000000 * X RPM 0 0 0 RPM to Resume Fueling if Transmission Error Title: RPM to Resume Fueling if Transmission Error Location: 4968 Usage: Speed and RPM Limiter Parameters Tips: Rev limiter off RPM if transmission error. Conversion: RPM = 25.000000 * X RPM 0 0 0 MPH to Enter Fuel Cut Off Title: MPH to Enter Fuel Cut Off Location: 4969 Usage: Speed and RPM Limiter Parameters Tips: Speed limiter on MPH. Conversion: MPH = 1 * X MPH 1 0 0 MPH to Resume Fueling Title: MPH to Resume Fueling Location: 496A Usage: Speed and RPM Limiter Parameters Tips: Speed limiter off MPH. Conversion: MPH = 1 * X MPH 1 0 0 0 0 ==== BPW Limits =============================== BPW Limits 0 0 0 0 Minimum Synchronous BPW Title: Minimum Synchronous BPW Location: 496B, 496C Usage: BPW Limits Tips: Conversion: uSec. = 15.2587890 * X uSec. 1 0 0 Minimum Synchronous BPW Allowed Title: Minimum Synchronous BPW Allowed Location: 496D, 496E Usage: BPW Limits Tips: Minimum synchronous BPW allowed if PCM calculations are less than setting. Conversion: uSec. = 15.2587890 * X uSec. 1 0 0 Async Short BPW Offset Bias Title: Async Short BPW Offset Bias Location: 496F, 4970 Usage: BPW Limits Tips: Used with Asynchronous fuel delivery. Offset bias for short BPW if L400E Bit 4 "Async Short BPW Offset vs. BPW " is not enabled. Setting added to table L4977 " Async Short BPW Offset vs. BPW " if L400E Bit 4 "Use Async Short BPW Offset vs. BPW Table" is enabled. Conversion: uSec. = 15.2587890 * X uSec. 1 0 0 Degrees of Delay from DRP to Injector Firing Title: Degrees of Delay from DRP to Injector Firing Location: 4971 Usage: BPW Limits Tips: Used in CPI/ PFI mode only, see L400B Bit 0. Conversion: Deg = X / 1.422222 Deg. 0 0 Minimum Time in Double Fire Title: Minimum Time in Double Fire Location: 4972 Usage: BPW Limits Tips: Used in CPI/ PFI mode only, see L400B Bit 0. Minimum time to transition back to single fire mode. Conversion: Deg = X / 1.422222 Deg. 0 0 0 0 ==== Engine Constants =========================== Engine Constants 0 0 0 0 Injector Flow Rate (TBI lb/hr) Title: Injector Flow Rate (TBI lb/hr) Location: 4D90, 4D91 Usage: Engine Constants Tips: Flow rate of one injector at current fuel pressure. Conversion: TBI lb/hr = (X / 819.2) * 7.93651 lb/hr 1 0 0 Injector Flow Rate (CPI lb/hr) Title: Injector Flow Rate (CPI lb/hr) Location: 4D90, 4D91 Usage: Engine Constants Tips: Flow rate of CPI injector unit at current fuel pressure. Conversion: CPI lb/hr = (X / 273.1) * 7.93651 lb/hr 1 0 0 Injector Flow Rate (MPFI lb/hr) Title: Injector Flow Rate (MPFI lb/hr) Location: 4D90, 4D91 Usage: Engine Constants Tips: Flow rate of one injector at current fuel pressure. Conversion: MPFI lb/hr = ( X / 1638.4) * 7.93651 lb/hr 1 0 0 Injector Flow Rate (TBI gms/sec) Title: Injector Flow Rate (TBI gms/sec) Location: 4D90, 4D91 Usage: Engine Constants Tips: Flow rate of one injector at current fuel pressure. Conversion: TBI gms/sec = X / 819.2 gms/sec 0 0 Injector Flow Rate (CPI gms/sec) Title: Injector Flow Rate (CPI gms/sec) Location: 4D90, 4D91 Usage: Engine Constants Tips: Flow rate of CPI injector unit at current fuel pressure. Conversion: CPI gms/sec = X / 273.1 gms/sec 0 0 Injector Flow Rate (MPFI gms/sec) Title: Injector Flow Rate (MPFI gms/sec) Location: 4D90, 4D91 Usage: Engine Constants Tips: Flow rate of one injector at current fuel pressure. Conversion: MPFI gms/sec = X / 1638.4 gms/sec 0 0 Cylinder Volume Title: Cylinder Volume Location: 4D92 Usage: Engine Constants Tips: The cubic inch displacement of one cylinder. Conversion: CID = 0.275039 * X CID 0 0 0 0 ==== Cranking Fuel Parameters ====================== Cranking Fuel Parameters 0 0 0 0 Minimum DRP for L4DAB Table Title: Minimum DRP for L4DAB Table Location: 4D93 Usage: Cranking Fuel Parameters Tips: DRP threshold to use RPM based crank fuel multipliers at L4DAB "Crank Fuel Multiplier vs. RPM". Conversion: DRP = 1 * X DRP 0 0 0 Crank DRP Counter after Stall Title: Crank DRP Counter after Stall Location: 4D94 Usage: Cranking Fuel Parameters Tips: Initiate crank DRP counter to setting on bad shutdown (stall). Conversion: DRP = 1 * X DRP 0 0 0 DRP Counter Limit for Fuel Pump Relay Failure Title: DRP Counter Limit for Fuel Pump Relay Failure Location: 4D95 Usage: Cranking Fuel Parameters Tips: DRP counter limit for fuel pump relay failure. Conversion: DRP = 1 * X DRP 0 0 0 Fuel Pump Volts to Limit DRP Counter Title: Fuel Pump Volts to Limit DRP Counter Location: 4D96 Usage: Cranking Fuel Parameters Tips: Lower fuel pump voltage limit to allow DRP counter to update. Conversion: Volts = .1 * X Volts 1 0 0 Temperature for Cold Cranking Title: Temperature for Cold Cranking Location: 4D97 Usage: Cranking Fuel Parameters Tips: If temperature less than setting use table L4DDC "Cold Crank BPW Multiplier vs. DRP". If temperature equal to or greater than setting use table L4DF4 "Non Hot Restart Crank BPW multiplier vs. DRP". Conversion: Temp (C) = 0.750000 * X + -40 C 1 0 0 Crank BPW vs. Temperature Table Scalar Title: Crank BPW vs. Temperature Table Scalar Location: 4D98, 4D99 Usage: Cranking Fuel Parameters Tips: Scalar for table L4D9A "Crank BPW vs. Temperature". This value will be automatically accounted for in table L4D9A "Crank BPW vs. Temperature". Conversion: Scalar = X / 65.536 Scalar 0 0 0 0 ==== AIR Management Qualifiers ===================== AIR Management Qualifiers 0 0 0 0 Slow Filtered O2 Coefficient for AIR Title: Slow Filtered O2 Coefficient for AIR Location: 4E87 Usage: AIR Management Qualifiers Tips: Conversion: Coefficient = X / 2.56 Coefficient 1 0 0 Upper RPM for AIR Title: Upper RPM for AIR Location: 4E88 Usage: AIR Management Qualifiers Tips: AIR will be disabled if RPM greater than setting. Conversion: RPM = 25.000000 * X RPM 0 0 0 Minimum Map for AIR Title: Minimum Map for AIR Location: 4E89 Usage: AIR Management Qualifiers Tips: AIR will be disabled if MAP less than setting. Conversion: MAP (Kpa) = 0.369000 * X + 10.35 Kpa 1 0 0 Minimum Temperature for AIR Title: Minimum Temperature for AIR Location: 4E8A Usage: AIR Management Qualifiers Tips: AIR will be disabled if temperature less than setting. Conversion: Temp (C) = 0.750000 * X + -40 C 1 0 0 Maximum Time for AIR if PE Title: Maximum Time for AIR if PE Location: 4E8B Usage: AIR Management Qualifiers Tips: Air will be disabled if time greater than setting if PE is entered. Conversion: Sec. = 0.100000 * X Sec. 1 0 0 Filter Coefficient for MPH Title: Filter Coefficient for MPH Location: 4E8C Usage: AIR Management Qualifiers Tips: Lag filter coefficient for VSS (L02A5) Filter MPH. Conversion: Coefficient = X / 2.56 Coefficient 1 0 0 0 0 ==== IAC Parameters ============================ IAC Parameters 0 0 0 0 Minimum Temperature for IAC before Startup Title: Minimum Temperature for IAC before Startup Location: 4E8F Usage: IAC Parameters Tips: Minimum temperature threshold to move IAC prior to initial startup. Conversion: Temp (C) = 0.750000 * X + -40 C 1 0 0 Park Position for IAC Title: Park Position for IAC Location: 4EAE Usage: IAC Parameters Tips: Conversion: Steps = 1 * X Steps 0 0 0 Default Value for P/N Idle if Memory Failure Title: Default Value for P/N Idle if Memory Failure Location: 4EAF Usage: IAC Parameters Tips: Conversion: % Airflow = 0.390625 * X % Airflow 0 0 0 Default Value for Drive Idle if Memory Failure Title: Default Value for Drive Idle if Memory Failure Location: 4EB0 Usage: IAC Parameters Tips: Conversion: % Airflow = 0.390625 * X % Airflow 0 0 0 Added Airflow for A/C On if Memory Failure and High Temp Title: Added Airflow for A/C On if Memory Failure and High Temp Location: 4EB1 Usage: IAC Parameters Tips: Used if temperature greater than L4EB3 "IAC High Engine Temperature". Conversion: % Airflow = 0.390625 * X % Airflow 0 0 0 Added Airflow for A/C On if Memory Failure and Normal Temp Title: Added Airflow for A/C On if Memory Failure and Normal Temp Location: 4EB2 Usage: IAC Parameters Tips: Used if temperature less than L4EB3 "IAC High Engine Temperature". Conversion: % Airflow = 0.390625 * X % Airflow 0 0 0 IAC High Engine Temperature Title: IAC High Engine Temperature Location: 4EB3 Usage: IAC Parameters Tips: Used for L4EB1 "Added Airflow for A/C On if Memory Failure and High Temp" and L4EB2 "Added Airflow for A/C On if Memory Failure and Normal Temp". Conversion: Temp (C) = 0.750000 * X + -40 C 1 0 0 Minimum Volts for IAC Operation Title: Minimum Volts for IAC Operation Location: 4EB4 Usage: IAC Parameters Tips: Conversion: Volts = .1 * X Volts 1 0 0 MPH for IAC Reset if Memory Failure Title: MPH for IAC Reset if Memory Failure Location: 4EB5 Usage: IAC Parameters Tips: Conversion: MPH = 1.0 * X MPH 1 0 0 IAC Added Air after Startup Title: IAC Added Air after Startup Location: 4EB6 Usage: IAC Parameters Tips: Replaces TPS. Conversion: % Airflow = 0.390625 * X % Airflow 1 0 0 Decay Period for Initial IAC Flow Title: Decay Period for Initial IAC Flow Location: 4EB7 Usage: IAC Parameters Tips: Conversion: msec. = 100 * X msec. 0 0 0 Time until Initial Idle Speed Decay Title: Time until Initial Idle Speed Decay Location: 4EB8 Usage: IAC Parameters Tips: Run before start of L4EB9 "Initial Idle Speed Decay Period". Conversion: Sec. = 1.0 * X Sec. 1 0 0 Initial Idle Speed Decay Period Title: Initial Idle Speed Decay Period Location: 4EB9 Usage: IAC Parameters Tips: PER 12.5 msec INT PERIOD. Decay period after L4EB8 "Time until Initial Idle Speed Decay". Conversion: msec. = 100 * X msec. 0 0 0 Initial Idle Speed Multiplier if in P/N Title: Initial Idle Speed Multiplier if in P/N Location: 4EBA Usage: IAC Parameters Tips: Conversion: Multiplier = X / 128 Multiplier 0 0 Decay Multiplier for Initial IAC Flow Title: Decay Multiplier for Initial IAC Flow Location: 4EBB Usage: IAC Parameters Tips: Conversion: % Multiplier = 0.390625 * X % 1 0 0 Decay Multiplier for Coupled Flow, P/N Title: Decay Multiplier for Coupled Flow, P/N Location: 4EBC Usage: IAC Parameters Tips: Conversion: % Multiplier = 0.390625 * X % 1 0 0 Decay Multiplier for Coupled Flow, Drive Title: Decay Multiplier for Coupled Flow, Drive Location: 4EBD Usage: IAC Parameters Tips: Conversion: % Multiplier = 0.390625 * X % 1 0 0 Upper MPH to Decay Initial IAC Flow Title: Upper MPH to Decay Initial IAC Flow Location: 4EBE Usage: IAC Parameters Tips: Conversion: MPH = 1.0 * X MPH 1 0 0 Initial IAC Flow vs. Temperature Kickdown Multiplier Title: Initial IAC Flow vs. Temperature Kickdown Multiplier Location: 4EBF Usage: IAC Parameters Tips: Conversion: % Multiplier = 0.390625 * X % 1 0 0 0 0 ALOWABLE DIFFERENCES BETWEEN INITIAL IAC FLOW ALOWABLE DIFFERENCES BETWEEN INITIAL IAC FLOW 0 0 Maximum Allowable Difference (P/N to Drive) Title: Maximum Allowable Difference (P/N to Drive) Location: 4EEC Usage: IAC Parameters Tips: P/N to Drive. Flows are not saved if significantly different from one another. Conversion: % Airflow = 0.390625 * X + % Airflow 0 0 0 Minimum Allowable Difference (P/N to Drive) Title: Minimum Allowable Difference (P/N to Drive) Location: 4EED Usage: IAC Parameters Tips: P/N to Drive. Flows are not saved if significantly different from one another. Conversion: % Airflow = 0.390625 * X - % Airflow 0 0 0 Maximum Allowable Difference (Drive to P/N) Title: Maximum Allowable Difference (Drive to P/N) Location: 4EEE Usage: IAC Parameters Tips: Drive to P/N. Flows are not saved if significantly different from one another. Conversion: % Airflow = 0.390625 * X + % Airflow 0 0 0 Minimum Allowable Difference (Drive to P/N) Title: Minimum Allowable Difference (Drive to P/N) Location: 4EEF Usage: IAC Parameters Tips: Drive to P/N. Flows are not saved if significantly different from one another. Conversion: % Airflow = 0.390625 * X - % Airflow 0 0 0 0 0 ==== Closed Loop Idle Qualifiers ===================== Closed Loop Idle Qualifiers 0 0 0 0 Upper Limit for Closed Throttle Title: Upper Limit for Closed Throttle Location: 4EF0 Usage: Closed Loop Idle Qualifiers Tips: Conversion: % TPS = 0.390625 * X % TPS 0 0 Upper MPH Limit for Closed Loop Idle Title: Upper MPH Limit for Closed Loop Idle Location: 4EF1 Usage: Closed Loop Idle Qualifiers Tips: Conversion: MPH = 1.0 * X MPH 1 0 0 Closed Loop Enable Delay Title: Closed Loop Enable Delay Location: 4EF2 Usage: Closed Loop Idle Qualifiers Tips: Closed loop enable delay if qualifiers not met. Conversion: msec. = 25 * X msec. 0 0 0 0 0 ==== IAC Transition Parameters ===================== IAC Transition Parameters 0 0 0 0 IAC Flow Multiplier for A/C On to Off Transition Title: IAC Flow Multiplier for A/C On to Off Transition Location: 4F0D Usage: IAC Transition Parameters Tips: Conversion: % Multiplier = 0.390625 * X % 1 0 0 Minimum IAC A/C On to Off Transition Flow Title: Minimum IAC A/C On to Off Transition Flow Location: 4F0E Usage: IAC Transition Parameters Tips: Conversion: % Airflow = 0.390625 * X % Airflow 1 0 0 Maximum IAC A/C On to Off Transition Flow Title: Maximum IAC A/C On to Off Transition Flow Location: 4F0F Usage: IAC Transition Parameters Tips: Conversion: % Airflow = 0.390625 * X % Airflow 1 0 0 A/C On to Off Transition Period Title: A/C On to Off Transition Period Location: 4F10 Usage: IAC Transition Parameters Tips: Conversion: msec. = 25 * X msec. 0 0 0 Additional Added Delay for Closed Loop Idle during A/C Transition Title: Additional Added Delay for Closed Loop Idle during A/C Transition Location: 4F11 Usage: IAC Transition Parameters Tips: Conversion: msec. = 25 * X msec. 0 0 0 Flow Transition Multiplier for A/C Transition Title: Flow Transition Multiplier for A/C Transition Location: 4F1A Usage: IAC Transition Parameters Tips: Conversion: % Multiplier = X / 2.56 % 1 0 0 Minimum Allowed Airflow Change for A/C Transition Title: Minimum Allowed Airflow Change for A/C Transition Location: 4F1B Usage: IAC Transition Parameters Tips: Conversion: % Airflow = X / 2.56 % Airflow 1 0 0 Maximum Allowed Airflow Change for A/C Transition Title: Maximum Allowed Airflow Change for A/C Transition Location: 4F1C Usage: IAC Transition Parameters Tips: Conversion: % Airflow = X / 2.56 % Airflow 1 0 0 Idle Transition Period for A/C Transition Title: Idle Transition Period for A/C Transition Location: 4F1E Usage: IAC Transition Parameters Tips: Conversion: msec. = 25 * X msec. 0 0 0 Delay for Closed Loop Idle after A/C Transition Title: Delay for Closed Loop Idle after A/C Transition Location: 4F1F Usage: IAC Transition Parameters Tips: Conversion: msec. = 25 * X msec. 0 0 0 A/C Transition Flow Decay Rate Title: A/C Transition Flow Decay Rate Location: 4F20 Usage: IAC Transition Parameters Tips: Conversion: % Airflow = X * 2.56 % Airflow 1 0 0 A/C Transition Flow Decay Period Title: A/C Transition Flow Decay Period Location: 4F21 Usage: IAC Transition Parameters Tips: Conversion: msec. = 100 * X msec. 0 0 0 0 0 PARK TO DRIVE PARK TO DRIVE 0 0 Added IAC Flow for P to D Shift Title: Added IAC Flow for P to D Shift Location: 4F22 Usage: IAC Transition Parameters Tips: Conversion: % Airflow = X / 2.56 % Airflow 1 0 0 Transition Period for P to D Shift Title: Transition Period for P to D Shift Location: 4F23 Usage: IAC Transition Parameters Tips: Conversion: msec. = 25 * X msec. 0 0 0 0 0 DRIVE TO PARK DRIVE TO PARK 0 0 Added IAC Flow for D to P Shift Title: Added IAC Flow for D to P Shift Location: 4F24 Usage: IAC Transition Parameters Tips: Conversion: % Airflow = X / 2.56 % Airflow 1 0 0 Transition Period for D to P Shift Title: Transition Period for D to P Shift Location: 4F25 Usage: IAC Transition Parameters Tips: Conversion: msec. = 25 * X msec. 0 0 0 Closed Loop Idle Delay for D to P Shift Title: Closed Loop Idle Delay for D to P Shift Location: 4F26 Usage: IAC Transition Parameters Tips: Conversion: msec. = 25 * X msec. 0 0 0 Temperature for Cold Idle Added Delay during P/N or Drive Transition Title: Temperature for Cold Idle Added Delay during P/N or Drive Transition Location: 4F27 Usage: IAC Transition Parameters Tips: Conversion: Temp (C) = 0.750000 * X + -40 C 1 0 0 0 0 PARK TO DRIVE PARK TO DRIVE 0 0 Added Idle Delay for P to D Transition Title: Added Idle Delay for P to D Transition Location: 4F28 Usage: IAC Transition Parameters Tips: Added idle delay for closed loop when cold and have shifted from park to drive. Conversion: msec. = 25 * X msec. 0 0 0 Addition Delay for P to D Transition Title: Addition Delay for P to D Transition Location: 4F29 Usage: IAC Transition Parameters Tips: Additional park to drive shift transition delay when cold. Conversion: msec. = 25 * X msec. 0 0 0 0 0 DRIVE TO PARK DRIVE TO PARK 0 0 Added Idle Delay for D to P Transition Title: Added Idle Delay for D to P Transition Location: 4F2A Usage: IAC Transition Parameters Tips: Added idle delay for closed loop when cold and have shifted from drive to park. Conversion: msec. = 25 * X msec. 0 0 0 Addition Delay for D to P Transition Title: Addition Delay for D to P Transition Location: 4F2B Usage: IAC Transition Parameters Tips: Additional park to drive shift transition delay when cold. Conversion: msec. = 25 * X msec. 0 0 0 0 0 POWER STEERING COMPENSATION POWER STEERING COMPENSATION 0 0 Added Flow for P/S Compensation Title: Added Flow for P/S Compensation Location: 4F2C Usage: IAC Transition Parameters Tips: Conversion: % = X / 2.56 % Airflow 1 0 0 Closed Loop Idle Delay if P/S Compensation in Affect Title: Closed Loop Idle Delay if P/S Compensation in Affect Location: 4F2D Usage: IAC Transition Parameters Tips: Conversion: msec. = 25 * X msec. 0 0 0 P/S Compensation IAC Flow Decay Period Title: P/S Compensation IAC Flow Decay Period Location: 4F2E Usage: IAC Transition Parameters Tips: Conversion: msec. = 25 * X msec. 0 0 0 P/S Compensation Flow Decay Rate Title: P/S Compensation Flow Decay Rate Location: 4F2F Usage: IAC Transition Parameters Tips: Conversion: % = X / 2.56 % Airflow 1 0 0 0 0 ==== Idle Speed Parameters ======================== Idle Speed Parameters 0 0 0 0 Error Gain Factor for Rough Idle Title: Error Gain Factor for Rough Idle Location: 4F7B Usage: Idle Speed Parameters Tips: Conversion: Factor = 0.00390625 * X Factor 0 0 Coefficient for RPM Variations Title: Coefficient for RPM Variations Location: 4F7C Usage: Idle Speed Parameters Tips: Conversion: Coefficient = X / .256 Coefficient 1 0 0 0 0 DEFAULT RPM ERRORS FOR TRANSITIONS DEFAULT RPM ERRORS FOR TRANSITIONS 0 0 Upper Default RPM Error (Open Throttle) Title: Upper Default RPM Error (Open Throttle) Location: 4F7D Usage: Idle Speed Parameters Tips: Conversion: RPM = 12.500000 * X RPM 0 0 0 Default RPM Error for P/N to Drive Transition Title: Default RPM Error for P/N to Drive Transition Location: 4F7E Usage: Idle Speed Parameters Tips: Conversion: RPM = 12.500000 * X RPM 0 0 0 Default RPM Error for A/C Transition Title: Default RPM Error for A/C Transition Location: 4F7F Usage: Idle Speed Parameters Tips: Conversion: RPM = 12.500000 * X RPM 0 0 0 Default RPM Error for P/S Active Title: Default RPM Error for P/S Active Location: 4F80 Usage: Idle Speed Parameters Tips: Conversion: RPM = 12.500000 * X RPM 0 0 0 RPM Error Threshold for Rough Idle Title: RPM Error Threshold for Rough Idle Location: 4F81 Usage: Idle Speed Parameters Tips: Conversion: RPM = 12.500000 * X RPM 0 0 0 0 0 LOW BATTERY VOLTS CORRECTION PARAMETERS LOW BATTERY VOLTS CORRECTION PARAMETERS 0 0 Lower Volts to Begin Raising RPM Title: Lower Volts to Begin Raising RPM Location: 4F82 Usage: Idle Speed Parameters Tips: Lower threshold to begin raising RPM to compensate for low battery volts. Conversion: Volts = .1 * X Volts 1 0 0 RPM Gain Per Volt Title: RPM Gain Per Volt Location: 4F83 Usage: Idle Speed Parameters Tips: Conversion: Gain(RPM/Volt) = X * (125/256) RPM per Volt 0 0 0 Maximum Added RPM for Low Volts Title: Maximum Added RPM for Low Volts Location: 4F84 Usage: Idle Speed Parameters Tips: Conversion: RPM = 12.500000 * X RPM 0 0 0 0 0 CCP COMPENSATION PARAMETERS CCP COMPENSATION PARAMETERS 0 0 Upper BLM Limit for Idle Purge Compensation Title: Upper BLM Limit for Idle Purge Compensation Location: 4F85 Usage: Idle Speed Parameters Tips: Conversion: BLM = 1 * X BLM 0 0 0 Minimum Time before Idle Purge Compensation Title: Minimum Time before Idle Purge Compensation Location: 4F86 Usage: Idle Speed Parameters Tips: Conversion: Sec. = 1.0 * X Sec. 1 0 0 Lower Temperature for Idle Purge Compensation Title: Lower Temperature for Idle Purge Compensation Location: 4F87 Usage: Idle Speed Parameters Tips: Conversion: Temp (C) = 0.750000 * X + -40 C 1 0 0 Idle Purge Compensation (P/N, A/C Off) Title: Idle Purge Compensation (P/N, A/C Off) Location: 4F88 Usage: Idle Speed Parameters Tips: Conversion: RPM = 12.500000 * X RPM 0 0 0 Idle Purge Compensation (P/N, A/C On) Title: Idle Purge Compensation (P/N, A/C On) Location: 4F89 Usage: Idle Speed Parameters Tips: Conversion: RPM = 12.500000 * X RPM 0 0 0 Idle Purge Compensation (Drive, A/C Off) Title: Idle Purge Compensation (Drive, A/C Off) Location: 4F8A Usage: Idle Speed Parameters Tips: Conversion: RPM = 12.500000 * X RPM 0 0 0 Idle Purge Compensation (Drive, A/C On) Title: Idle Purge Compensation (Drive, A/C On) Location: 4F8B Usage: Idle Speed Parameters Tips: Conversion: RPM = 12.500000 * X RPM 0 0 0 0 0 HIGH A/C PRESSURE RPM COMPENSATION PARAMETERS HIGH A/C PRESSURE RPM COMPENSATION PARAMETERS 0 0 Desired RPM for High A/C Pressure (P/N) Title: Desired RPM for High A/C Pressure (P/N) Location: 4F8C Usage: Idle Speed Parameters Tips: Conversion: RPM = 12.500000 * X RPM 0 0 0 Desired RPM for High A/C Pressure (Drive) Title: Desired RPM for High A/C Pressure (Drive) Location: 4F8D Usage: Idle Speed Parameters Tips: Conversion: RPM = 12.500000 * X RPM 0 0 0 Added RPM Delay if High Load Title: Added RPM Delay if High Load Location: 4F8E Usage: Idle Speed Parameters Tips: Delay to add in desired RPM if high load previously present. Conversion: Sec. = 1.0 * X Sec. 1 0 0 Added RPM Delay if not High Load Title: Added RPM Delay if not High Load Location: 4F8F Usage: Idle Speed Parameters Tips: Delay to add in desired RPM if high load not previously present. Conversion: Sec. = 1.0 * X Sec. 1 0 0 0 0 ==== Integral Idle Control Parameters ================== Integral Idle Control Parameters 0 0 0 0 STEADY STATE IDLE STEADY STATE IDLE 0 0 Upper RPM Error Limit Title: Upper RPM Error Limit Location: 4FBC Usage: Integral Idle Control Parameters Tips: Upper RPM error limit for steady state idle. Conversion: RPM = 12.500000 * X RPM 1 0 0 Lower Temperature Threshold Title: Lower Temperature Threshold Location: 4FBD Usage: Integral Idle Control Parameters Tips: Lower temp threshold for steady state idle check. Conversion: Temp (C) = 0.750000 * X + -40 C 1 0 0 Upper Temperature Threshold Title: Upper Temperature Threshold Location: 4FBE Usage: Integral Idle Control Parameters Tips: Upper temp threshold for steady state idle check. Conversion: Temp (C) = 0.750000 * X + -40 C 0 0 0 0 ALLOWABLE INTEGRATOR DIFFERENCE (P/N) ALLOWABLE INTEGRATOR DIFFERENCE (P/N) 0 0 Minimum Allowable Difference (P/N) Title: Minimum Allowable Difference (P/N) Location: 4FBF Usage: Integral Idle Control Parameters Tips: Allowable integrator difference for A/C and non-A/C terms, P/N. Conversion: % = 0.390625 * X % Flow 1 0 0 Maximum Allowable Difference (P/N) Title: Maximum Allowable Difference (P/N) Location: 4FC0 Usage: Integral Idle Control Parameters Tips: Allowable integrator difference for A/C and non-A/C terms, P/N. Conversion: % = 0.390625 * X % Flow 1 0 0 0 0 ALLOWABLE INTEGRATOR DIFFERENCE (DRIVE) ALLOWABLE INTEGRATOR DIFFERENCE (DRIVE) 0 0 Minimum Allowable Difference (Drive) Title: Minimum Allowable Difference (Drive) Location: 4FC1 Usage: Integral Idle Control Parameters Tips: Allowable integrator difference for A/C and non-A/C terms, drive. Conversion: % = 0.390625 * X % Flow 1 0 0 Maximum Allowable Difference (Drive) Title: Maximum Allowable Difference (Drive) Location: 4FC2 Usage: Integral Idle Control Parameters Tips: Allowable integrator difference for A/C and non-A/C terms, drive. Conversion: % = 0.390625 * X % Flow 1 0 0 Sure hope someone uses this stuff. 0 0 ALLOWABLE INTEGRATOR DIFFERENCE (P/N AND DRIVE) ALLOWABLE INTEGRATOR DIFFERENCE (P/N AND DRIVE) 0 0 Maximum Allowable Difference (P/N and Drive) Title: Maximum Allowable Difference (P/N and Drive) Location: 4FC3 Usage: Integral Idle Control Parameters Tips: Allowable integrator difference for drive and P/N terms, both non-A/C and A/C. Conversion: % = 0.390625 * X % Flow 1 0 0 Minimum Allowable Difference (P/N and Drive) Title: Minimum Allowable Difference (P/N and Drive) Location: 4FC4 Usage: Integral Idle Control Parameters Tips: Allowable integrator difference for drive and P/N terms, both non-A/C and A/C. Conversion: % = 0.390625 * X % Flow 1 0 0 0 0 ALLOWABLE INTEGRATOR DIFFERENCE ALLOWABLE INTEGRATOR DIFFERENCE 0 0 Maximum Allowable Difference (No A/C) Title: Maximum Allowable Difference (No A/C) Location: 4FC5 Usage: Integral Idle Control Parameters Tips: Allowable integral difference between steady state and current integral terms, checked when not in closed loop idle. Conversion: % = 0.390625 * X % Flow 1 0 0 Minimum Allowable Difference (A/C) Title: Minimum Allowable Difference (A/C) Location: 4FC6 Usage: Integral Idle Control Parameters Tips: Allowable integral difference between steady state and current integral terms, checked when not in closed loop idle. Conversion: % = 0.390625 * X % Flow 1 0 0 0 0 ==== Idle Proportional Action Qualifiers ================= Idle Proportional Action Qualifiers 0 0 0 0 Lower MPH to Limit Proportional Action Title: Lower MPH to Limit Proportional Action Location: 4FC7 Usage: Idle Proportional Action Qualifiers Tips: Lower threshold to limit proportional action. Conversion: MPH = 1.0 * X MPH 1 0 0 Upper MPH to Restore Proportional Action Title: Upper MPH to Restore Proportional Action Location: 4FC8 Usage: Idle Proportional Action Qualifiers Tips: Upper threshold to restore proportional action. Conversion: MPH = 1.0 * X MPH 1 0 0 Upper Limit for RPM Error Title: Upper Limit for RPM Error Location: 4FC9 Usage: Idle Proportional Action Qualifiers Tips: Upper limit for RPM error when limiting proportional action. Conversion: RPM = 12.500000 * X RPM 0 0 0 0 0 FILTER COEFFICIENT FOR LIMITING DERIVATIVE IDLE ACTION FILTER COEFFICIENT FOR LIMITING DERIVATIVE IDLE ACTION 0 0 Coefficient for Positive Action Title: Coefficient for Positive Action Location: 5038 Usage: Idle Proportional Action Tips: Conversion: Coefficient = X / 256 Coefficient 3 0 0 Coefficient for Negative Action Title: Coefficient for Negative Action Location: 5039 Usage: Idle Proportional Action Tips: Conversion: Coefficient = X / 256 Coefficient 3 0 0 0 0 ==== Stall Saver Activation Thresholds ================== Stall Saver Activation Thresholds 0 0 0 0 Stall Saver Activation (P/N, A/C Off) (%) Title: Stall Saver Activation (P/N, A/C Off) (%) Location: 504B Usage: Stall Saver Activation Thresholds Tips: See L4E8D Bit 7 "Stall Saver Activation Thresholds". If not enabled, qualifiers are % multipliers for desired idle to obtain RPM threshold. If enabled, qualifiers are RPM thresholds. Conversion: Multiplier % = 0.390625 * X Multiplier % 1 0 0 Stall Saver Activation (P/N, A/C On) (%) Title: Stall Saver Activation (P/N, A/C On) (%) Location: 504C Usage: Stall Saver Activation Thresholds Tips: See L4E8D Bit 7 "Stall Saver Activation Thresholds". If not enabled, qualifiers are % multipliers for desired idle to obtain RPM threshold. If enabled, qualifiers are RPM thresholds. Conversion: Multiplier % = 0.390625 * X Multiplier % 1 0 0 Stall Saver Activation (Drive, A/C Off) (%) Title: Stall Saver Activation (Drive, A/C Off) (%) Location: 504D Usage: Stall Saver Activation Thresholds Tips: See L4E8D Bit 7 "Stall Saver Activation Thresholds". If not enabled, qualifiers are % multipliers for desired idle to obtain RPM threshold. If enabled, qualifiers are RPM thresholds. Conversion: Multiplier % = 0.390625 * X Multiplier % 1 0 0 Stall Saver Activation (Drive, A/C On) (%) Title: Stall Saver Activation (Drive, A/C On) (%) Location: 504E Usage: Stall Saver Activation Thresholds Tips: See L4E8D Bit 7 "Stall Saver Activation Thresholds". If not enabled, qualifiers are % multipliers for desired idle to obtain RPM threshold. If enabled, qualifiers are RPM thresholds. Conversion: Multiplier % = 0.390625 * X Multiplier % 1 0 0 Stall Saver Activation (P/N) (Lower RPM) Title: Stall Saver Activation (P/N) (Lower RPM) Location: 504B Usage: Stall Saver Activation Thresholds Tips: See L4E8D Bit 7 "Stall Saver Activation Thresholds". If not enabled, qualifiers are % multipliers for desired idle to obtain RPM threshold. If enabled, qualifiers are RPM thresholds. Conversion: RPM = 12.500000 * X RPM 0 0 0 Stall Saver Activation (P/N) (Upper RPM) Title: Stall Saver Activation (P/N) (Upper RPM) Location: 504C Usage: Stall Saver Activation Thresholds Tips: See L4E8D Bit 7 "Stall Saver Activation Thresholds". If not enabled, qualifiers are % multipliers for desired idle to obtain RPM threshold. If enabled, qualifiers are RPM thresholds. Conversion: RPM = 12.500000 * X RPM 0 0 0 Stall Saver Activation (Drive) (Lower RPM) Title: Stall Saver Activation (Drive) (Lower RPM) Location: 504D Usage: Stall Saver Activation Thresholds Tips: See L4E8D Bit 7 "Stall Saver Activation Thresholds". If not enabled, qualifiers are % multipliers for desired idle to obtain RPM threshold. If enabled, qualifiers are RPM thresholds. Conversion: RPM = 12.500000 * X RPM 0 0 0 Stall Saver Activation (Drive) ( Upper RPM) Title: Stall Saver Activation (Drive) ( Upper RPM) Location: 504E Usage: Stall Saver Activation Thresholds Tips: See L4E8D Bit 7 "Stall Saver Activation Thresholds". If not enabled, qualifiers are % multipliers for desired idle to obtain RPM threshold. If enabled, qualifiers are RPM thresholds. Conversion: RPM = 12.500000 * X RPM 0 0 0 0 0 ==== Stall Saver Corrections ======================== Stall Saver Corrections 0 0 0 0 Added Airflow (P/N, A/C Off) Title: Added Airflow (P/N, A/C Off) Location: 504F Usage: Stall Saver Corrections Tips: Conversion: % = 0.390625 * X % Airflow 1 0 0 Added Airflow (P/N, A/C On) Title: Added Airflow (P/N, A/C On) Location: 5050 Usage: Stall Saver Corrections Tips: Conversion: % = 0.390625 * X % Airflow 1 0 0 Added Airflow (Drive, A/C Off) Title: Added Airflow (Drive, A/C Off) Location: 5051 Usage: Stall Saver Corrections Tips: Conversion: % = 0.390625 * X % Airflow 1 0 0 Added Airflow (Drive, A/C On) Title: Added Airflow (Drive, A/C On) Location: 5052 Usage: Stall Saver Corrections Tips: Conversion: % = 0.390625 * X % Airflow 1 0 0 Delay before Re-Enabling (P/N) Title: Delay before Re-Enabling (P/N) Location: 5053 Usage: Stall Saver Corrections Tips: Conversion: Sec. = 0.025 * X Sec. 1 0 0 Delay before Re-Enabling (Drive) Title: Delay before Re-Enabling (Drive) Location: 5054 Usage: Stall Saver Corrections Tips: Conversion: Sec. = 0.025 * X Sec. 1 0 0 0 0 ==== Throttle Follower Parameters ==================== Throttle Follower Parameters 0 0 0 0 Maximum TPS for Throttle Follower (P/N) Title: Maximum TPS for Throttle Follower (P/N) Location: 506C Usage: Throttle Follower Parameters Tips: Conversion: % TPS = 0.390625 * X % TPS 1 0 0 Maximum TPS for Throttle Follower (Drive) Title: Maximum TPS for Throttle Follower (Drive) Location: 506D Usage: Throttle Follower Parameters Tips: Conversion: % TPS = 0.390625 * X % TPS 1 0 0 TPS Throttle Follower Coefficient (P/N) Title: TPS Throttle Follower Coefficient (P/N) Location: 506E Usage: Throttle Follower Parameters Tips: TPS throttle follower filtering coefficient, while in P/N. Conversion: Coefficient = X / 256 Coefficient 3 0 0 Minimum Flow Difference to Update Throttle Follower Flow Title: Minimum Flow Difference to Update Throttle Follower Flow Location: 5085 Usage: Throttle Follower Parameters Tips: Conversion: % = 0.390625 * X % 1 0 0 MAP for Scaling Down TPS Filter Coefficient Title: MAP for Scaling Down TPS Filter Coefficient Location: 5086 Usage: Throttle Follower Parameters Tips: Conversion: MAP (Kpa) = 0.369000 * X + 10.35 Kpa 1 0 0 Multiplier for Reducing Filter Coefficient Title: Multiplier for Reducing Filter Coefficient Location: 5087 Usage: Throttle Follower Parameters Tips: Multiplier for reducing filter coefficient when low MAP. Conversion: Multiplier = X / 256 Multiplier 1 0 0 Time for Limiting Throttle Follower Title: Time for Limiting Throttle Follower Location: 5095 Usage: Throttle Follower Parameters Tips: Time after throttle closes to limit throttle follower action. Extended throttle follower parameters. Conversion: Sec. = X / 10 Sec. 1 0 0 Flow Added to Steady State Integral (A/C Off, Drive) Title: Flow Added to Steady State Integral (A/C Off, Drive) Location: 5096 Usage: Throttle Follower Parameters Tips: Added flow for steady state integral cells on initialization. Extended throttle follower parameters. Conversion: % = 0.390625 * X % 1 0 0 Flow Added to Steady State Integral (A/C On, Drive) Title: Flow Added to Steady State Integral (A/C On, Drive) Location: 5097 Usage: Throttle Follower Parameters Tips: Added flow for steady state integral cells on initialization. Extended throttle follower parameters. Conversion: % = 0.390625 * X % 1 0 0 Lower Temperature for Cold Engine Mode Title: Lower Temperature for Cold Engine Mode Location: 5098 Usage: Throttle Follower Parameters Tips: Special idle air modifiers prior to CAT light off. Also used by non-CAT calibrations to reduce HC emissions. Conversion: Temp (C) = 0.750000 * X + -40 C 1 0 0 Upper Temperature for Cold Engine Mode Title: Upper Temperature for Cold Engine Mode Location: 5099 Usage: Throttle Follower Parameters Tips: Special idle air modifiers prior to CAT light off. Also used by non-CAT calibrations to reduce HC emissions. Conversion: Temp (C) = 0.750000 * X + -40 C 1 0 0 Maximum Time for Cold Engine Mode Title: Maximum Time for Cold Engine Mode Location: 509A, 509B Usage: Throttle Follower Parameters Tips: Special idle air modifiers prior to CAT light off. Also used by non-CAT calibrations to reduce HC emissions. Maximum time to remain in cold engine mode. Conversion: Sec. = 1.0 * X Sec. 1 0 0 Multiplier for Reducing Throttle Follower Action (Cold) Title: Multiplier for Reducing Throttle Follower Action (Cold) Location: 509C Usage: Throttle Follower Parameters Tips: Special idle air modifiers prior to CAT light off. Also used by non-CAT calibrations to reduce HC emissions. Conversion: % = 0.390625 * X % 1 0 0 Multiplier for Reducing Throttle Follower Action (Warm) Title: Multiplier for Reducing Throttle Follower Action (Warm) Location: 509D Usage: Throttle Follower Parameters Tips: Special idle air modifiers prior to CAT light off. Also used by non-CAT calibrations to reduce HC emissions. Multiplier for reducing T/F action during warm engine operation. Conversion: % = 0.390625 * X % 1 0 0 Multiplier for Lower TPS Limit Title: Multiplier for Lower TPS Limit Location: 509E Usage: Throttle Follower Parameters Tips: Special idle air modifiers prior to CAT light off. Also used by non-CAT calibrations to reduce HC emissions. Modify table L5088 "Lower Limit for TPS to Ensure Throttle Follower" by this factor. Multiplier for lower closed throttle TPS limit when in cool engine mode. Conversion: Multiplier = X / 64 Multiplier 0 0 Added Throttle Follower Gain Title: Added Throttle Follower Gain Location: 509F Usage: Throttle Follower Parameters Tips: Special idle air modifiers prior to CAT light off. Also used by non-CAT calibrations to reduce HC emissions. Added throttle follower gain for cool engine operation. Conversion: Gain = X / 64 Gain 0 0 0 0 ==== IAC AE, PE, DFCO Parameters =================== IAC AE, PE, DFCO Parameters 0 0 0 0 Lower Threshold for IAC AE Title: Lower Threshold for IAC AE Location: 50A6 Usage: IAC AE, PE, DFCO Parameters Tips: Conversion: % = 0.390625 * X % Flow 1 0 0 Upper Threshold for IAC AE Title: Upper Threshold for IAC AE Location: 50A7 Usage: IAC AE, PE, DFCO Parameters Tips: Conversion: % = 0.390625 * X % Flow 1 0 0 Maximum IAC % Flow in PE Title: Maximum IAC % Flow in PE Location: 50A8, 50A9 Usage: IAC AE, PE, DFCO Parameters Tips: Used by TBI systems to shut down IAC near WOT to improve air fuel distribution on dyno. Conversion: % = .00152587 * X % Flow 3 0 0 Flow Bias for Added IAC Flow in DFCO Title: Flow Bias for Added IAC Flow in DFCO Location: 50AA Usage: IAC AE, PE, DFCO Parameters Tips: Following table L50A1 "AE vs. % IAC Flow Difference". Conversion: % = 0.390625 * X % Flow 1 0 0 DFCO Decay Amount Title: DFCO Decay Amount Location: 50BC Usage: IAC AE, PE, DFCO Parameters Tips: DFCO flow decay rate per sec = decay amount/decay time rate. Conversion: % = 3.90625 * X % 0 0 0 DFCO Decay Rate Title: DFCO Decay Rate Location: 50BD Usage: IAC AE, PE, DFCO Parameters Tips: DFCO flow decay rate per sec = decay amount/decay time rate. Conversion: msec. = 100 * X msec. 0 0 0 0 0 ==== Throttle Kicker Parameters ===================== Throttle Kicker Parameters 0 0 0 0 Temperature to Enable Throttle Kicker Title: Temperature to Enable Throttle Kicker Location: 50C5 Usage: Throttle Kicker Parameters Tips: Conversion: Temp (C) = 0.750000 * X + -40 C 1 0 0 Throttle Kicker Bias Title: Throttle Kicker Bias Location: 50C6 Usage: Throttle Kicker Parameters Tips: Subtracted bias when throttle kicker is active. Conversion: % Flow = 0.390625 * X % Flow 1 0 0 Throttle Kicker Airflow Multiplier (Factor) Title: Throttle Kicker Airflow Multiplier (Factor) Location: 50C7 Usage: Throttle Kicker Parameters Tips: Conversion: Multiplier = X / 256 Multiplier 0 0 0 MPH to Enable Throttle Kicker (Low Baro) Title: MPH to Enable Throttle Kicker (Low Baro) Location: 50C8 Usage: Throttle Kicker Parameters Tips: Conversion: MPH = 1.0 * X MPH 0 0 0 TPS to Enable Throttle Kicker (Low Baro) Title: TPS to Enable Throttle Kicker (Low Baro) Location: 50C9 Usage: Throttle Kicker Parameters Tips: Conversion: % TPS = 0.390625 * X % TPS 1 0 0 Minimum Time for Throttle Kicker Title: Minimum Time for Throttle Kicker Location: 50CA Usage: Throttle Kicker Parameters Tips: Minimum time for throttle kicker to be active. Conversion: Sec. = 1.0 * X Sec. 1 0 0 Upper Baro to Disable Throttle Kicker Title: Upper Baro to Disable Throttle Kicker Location: 50CB Usage: Throttle Kicker Parameters Tips: Conversion: Kpa = 0.369000 * X Kpa 1 0 0 Lower Baro to Enable Throttle Kicker Title: Lower Baro to Enable Throttle Kicker Location: 50CC Usage: Throttle Kicker Parameters Tips: Conversion: Kpa = 0.369000 * X Kpa 1 0 0 Idle Integrator for Disabling Throttle Kicker Title: Idle Integrator for Disabling Throttle Kicker Location: 50CD Usage: Throttle Kicker Parameters Tips: Conversion: % Flow = 0.390625 * X % Flow 1 0 0 Lower Idle Integrator for Enabling Throttle Kicker (Low Baro) Title: Lower Idle Integrator for Enabling Throttle Kicker (Low Baro) Location: 50CE Usage: Throttle Kicker Parameters Tips: Conversion: % Flow = 0.390625 * X % Flow 1 0 0 RPM Error to Disable Throttle Kicker (Drive) Title: RPM Error to Disable Throttle Kicker (Drive) Location: 50CF Usage: Throttle Kicker Parameters Tips: Conversion: RPM = 25.000000 * X RPM 0 0 0 RPM Error to Disable Throttle Kicker (P/N) Title: RPM Error to Disable Throttle Kicker (P/N) Location: 50D0 Usage: Throttle Kicker Parameters Tips: Conversion: RPM = 25.000000 * X RPM 0 0 0 Minimum Time for Throttle Kicker to be Active Title: Minimum Time for Throttle Kicker to be Active Location: 50D1 Usage: Throttle Kicker Parameters Tips: Hysterias time if re-enable must stay on. Conversion: Sec. = 1.0 * X Sec. 1 0 0 Default Base TPS for Throttle Kicker Title: Default Base TPS for Throttle Kicker Location: 50D2 Usage: Throttle Kicker Parameters Tips: Default A/D TPS if non volatile memory failure. Conversion: % TPS = 0.390625 * X % TPS 1 0 0 Base TPS Offset for Throttle Kicker Title: Base TPS Offset for Throttle Kicker Location: 50D3 Usage: Throttle Kicker Parameters Tips: Conversion: % TPS = 0.390625 * X % TPS 1 0 0 Minimum TPS Difference for Error Title: Minimum TPS Difference for Error Location: 50D4 Usage: Throttle Kicker Parameters Tips: Minimum delta TPS threshold not to set error 36. Conversion: % TPS = 0.390625 * X % TPS 1 0 0 Minimum Time before Re-enabling Throttle Kicker Title: Minimum Time before Re-enabling Throttle Kicker Location: 50D5 Usage: Throttle Kicker Parameters Tips: Conversion: Sec. = (1.0 * X) + 255 Sec. 0 0 0 0 0 ==== Governor Parameters ======================== Governor Parameters 0 0 0 0 RPM Threshold for Engine Overspeed Title: RPM Threshold for Engine Overspeed Location: 50D6 Usage: Governor Parameters Tips: Conversion: RPM = 25.000000 * X RPM 0 0 0 Minimum Governor RPM Title: Minimum Governor RPM Location: 50D7 Usage: Governor Parameters Tips: Conversion: RPM = 25.000000 * X RPM 0 0 0 MPH Threshold for Governor Title: MPH Threshold for Governor Location: 50D8 Usage: Governor Parameters Tips: 0 = no MPH governing. Conversion: MPH = 1.0 * X MPH 1 0 0 MPH Error Threshold to Exit Governing Title: MPH Error Threshold to Exit Governing Location: 50D9 Usage: Governor Parameters Tips: Governor MPH error threshold to exit MPH governing. Conversion: MPH = 1.0 * X MPH 1 0 0 RPM Threshold for Governor Overspeed Light Title: RPM Threshold for Governor Overspeed Light Location: 50DA Usage: Governor Parameters Tips: Conversion: RPM = 25.000000 * X RPM 0 0 0 RPM Proportional Gain Term Title: RPM Proportional Gain Term Location: 50DB Usage: Governor Parameters Tips: Conversion: Gain = X / 64 Gain 0 0 MPH Proportional Gain Term Title: MPH Proportional Gain Term Location: 50DC Usage: Governor Parameters Tips: Conversion: Gain = X / 64 Gain 0 0 Desired TPS Integral Gain Term for MPH Overspeed Title: Desired TPS Integral Gain Term for MPH Overspeed Location: 50DD Usage: Governor Parameters Tips: Conversion: Gain = X / 64 Gain 0 0 Desired TPS Integral Gain Term for RPM Overspeed Title: Desired TPS Integral Gain Term for RPM Overspeed Location: 50DE Usage: Governor Parameters Tips: Conversion: Gain = X / 64 Gain 0 0 Upper Limit for Governor TPS Title: Upper Limit for Governor TPS Location: 50DF Usage: Governor Parameters Tips: Conversion: % TPS = 0.390625 * X % TPS 1 0 0 Minimum Desired TPS for Overspeed Title: Minimum Desired TPS for Overspeed Location: 50E0 Usage: Governor Parameters Tips: Conversion: % TPS = 0.390625 * X % TPS 1 0 0 Minimum Desired TPS for Derivative Action Title: Minimum Desired TPS for Derivative Action Location: 50E1 Usage: Governor Parameters Tips: Conversion: % TPS = 0.390625 * X % TPS 1 0 0 Filter Coefficient for Governor RPM Title: Filter Coefficient for Governor RPM Location: 50E2 Usage: Governor Parameters Tips: Conversion: Coefficient = X / 256 Coefficient 0 0 TPS Threshold for Return Gain Factors Title: TPS Threshold for Return Gain Factors Location: 50E3 Usage: Governor Parameters Tips: Conversion: % TPS = 0.390625 * X % TPS 1 0 0 High Desired TPS Return Gain Title: High Desired TPS Return Gain Location: 50E4 Usage: Governor Parameters Tips: Conversion: Gain = X / 64 Gain 0 0 Low Desired TPS Return Gain Title: Low Desired TPS Return Gain Location: 50E5 Usage: Governor Parameters Tips: Conversion: Gain = X / 64 Gain 0 0 0 0 ==== Shift Light Parameters ======================== Shift Light Parameters 0 0 0 0 Minimum Temperature for Shift Light Title: Minimum Temperature for Shift Light Location: 511D Usage: Shift Light Parameters Tips: Conversion: Temp (C) = 0.750000 * X + -40 C 1 0 0 TPS Lower Limit for Shift Light (Low Gears) Title: TPS Lower Limit for Shift Light (Low Gears) Location: 511E Usage: Shift Light Parameters Tips: If TPS % less than setting and in lower gears, turn off shift light. Conversion: % TPS = 0.390625 * X % TPS 1 0 0 TPS Lower Limit for Shift Light (High Gears) Title: TPS Lower Limit for Shift Light (High Gears) Location: 511F Usage: Shift Light Parameters Tips: If TPS % less than setting and in higher gears, turn off shift light. Conversion: % TPS = 0.390625 * X % TPS 1 0 0 RPM for Mandatory Shift Light Title: RPM for Mandatory Shift Light Location: 5120 Usage: Shift Light Parameters Tips: Conversion: RPM = 25.000000 * X RPM 0 0 0 Shift Light Activation Delay (Low Gears) Title: Shift Light Activation Delay (Low Gears) Location: 5121 Usage: Shift Light Parameters Tips: Conversion: Sec. = X / 10 Sec. 1 0 0 Shift Light Activation Delay (High Gears) Title: Shift Light Activation Delay (High Gears) Location: 5122 Usage: Shift Light Parameters Tips: Conversion: Sec. = X / 10 Sec. 1 0 0 0 0 ==== 700R4 Anti-Abuse Routine ===================== 700R4 Anti-Abuse Routine 0 0 0 0 Time for Anti-Abuse Routine Title: Time for Anti-Abuse Routine Location: 5153 Usage: 700R4 Anti-Abuse Routine Tips: Time for anti-abuse routine to be in effect. Conversion: msec. = 12.5 * X msec. 0 0 0 Maximum Speed for Park to Drive Title: Maximum Speed for Park to Drive Location: 5154 Usage: 700R4 Anti-Abuse Routine Tips: Conversion: MPH = 1.0 * X MPH 1 0 0 RPM Threshold to Flag Abuse Title: RPM Threshold to Flag Abuse Location: 5155 Usage: 700R4 Anti-Abuse Routine Tips: Conversion: Scaled RPM = (X - 64) * 25 RPM 2 0 0 0 RPM Threshold to Clear Abuse Flag Title: RPM Threshold to Clear Abuse Flag Location: 5156 Usage: 700R4 Anti-Abuse Routine Tips: Conversion: Scaled RPM = (X - 64) * 25 RPM 0 0 0 Minimum TPS for Anti-Abuse Routine Title: Minimum TPS for Anti-Abuse Routine Location: 5157 Usage: 700R4 Anti-Abuse Routine Tips: Conversion: % TPS = 0.390625 * X % TPS 1 0 0 0 0 ==== 700R4 TCC Parameters ======================= 700R4 TCC Parameters 0 0 0 0 Lower Temperature Limit for TCC Lockup Title: Lower Temperature Limit for TCC Lockup Location: 5158 Usage: 700R4 TCC Parameters Tips: Conversion: Temp (C) = 0.750000 * X + -40 C 1 0 0 TPS Hysteresis Title: TPS Hysteresis Location: 5159 Usage: 700R4 TCC Parameters Tips: TPS Hysteresis if TCC locked, used with table L5162 "Lower TPS for TCC to Lock vs. MPH". Conversion: % TPS = 0.390625 * X % TPS 1 0 0 Throttle Closing Limit Title: Throttle Closing Limit Location: 515A Usage: 700R4 TCC Parameters Tips: Delta TPS TCC limits to lock. Conversion: % = 0.390625 * X - % 1 0 0 Throttle Opening Limit Title: Throttle Opening Limit Location: 515B Usage: 700R4 TCC Parameters Tips: Delta TPS TCC limits to lock. Conversion: % = 0.390625 * X % 1 0 0 Relock Delay after Qualifiers Not Met Title: Relock Delay after Qualifiers Not Met Location: 515C Usage: 700R4 TCC Parameters Tips: TCC relock delay. Conversion: Sec. = X / 10 Sec. 1 0 0 Coast Relock Delay Title: Coast Relock Delay Location: 515D Usage: 700R4 TCC Parameters Tips: TCC relock delay. Conversion: Sec. = X / 10 Sec. 1 0 0 MPH to Lock TCC Title: MPH to Lock TCC Location: 515E Usage: 700R4 TCC Parameters Tips: MPH thresholds for TCC lockup. Conversion: MPH = 1.0 * X MPH 0 0 0 MPH to Unlock TCC Title: MPH to Unlock TCC Location: 515F Usage: 700R4 TCC Parameters Tips: MPH thresholds for TCC lockup. Conversion: MPH = 1.0 * X MPH 0 0 0 RPM to Lock TCC Title: RPM to Lock TCC Location: 5160 Usage: 700R4 TCC Parameters Tips: RPM thresholds for TCC lockup. Conversion: RPM = 25.000000 * X RPM 0 0 0 RPM to Unlock TCC Title: RPM to Unlock TCC Location: 5161 Usage: 700R4 TCC Parameters Tips: RPM thresholds for TCC lockup. Conversion: RPM = 25.000000 * X RPM 0 0 0 0 0 ==== VATS Parameters =========================== VATS Parameters 0 0 0 0 Lower Frequency Limit Title: Lower Frequency Limit Location: 5189, 518A Usage: VATS Parameters Tips: Conversion: msec. = (X * .00076293) * 10 msec. 0 0 Upper Frequency Limit Title: Upper Frequency Limit Location: 518B, 518C Usage: VATS Parameters Tips: Conversion: msec. = (X * .00076293) * 10 msec. 0 0 0 0 ==== 4L80-E Transmission Parameters ================== 4L80-E Transmission Parameters 0 0 0 0 Transmission PROM ID Title: Transmission PROM ID Location: 5D00, 5D01 Usage: 4L80-E Transmission Parameters Tips: Used for tracking different chip versions. This can be changed to whatever you wish. Doesn't affect calibration at all. Conversion: 1.000000 * X ID 0 0 0 Brake Switch Filter Time Title: Brake Switch Filter Time Location: 5D06 Usage: 4L80-E Transmission Parameters Tips: Minimum time for brake switch to change state. Conversion: Sec. = X / 160 Sec. 3 0 0 Transmission Baro Scalar Title: Transmission Baro Scalar Location: 5D07 Usage: 4L80-E Transmission Parameters Tips: Baro sensor voltage change per Kpa. Conversion: mVDC = .00434028 * X mVDC 0 0 Transmission Baro Bias Title: Transmission Baro Bias Location: 5D08, 5D09 Usage: 4L80-E Transmission Parameters Tips: Baro sensor at 0 pressure. Conversion: ???? ???? 0 0 0 Transmission Baro Filter Coefficient Title: Transmission Baro Filter Coefficient Location: 5D0A Usage: 4L80-E Transmission Parameters Tips: Conversion: Coefficient = X / 256 Coefficient 3 0 0 Transmission Temperature Filter Coefficient Title: Transmission Temperature Filter Coefficient Location: 5D0B Usage: 4L80-E Transmission Parameters Tips: Conversion: Coefficient = X / 256 Coefficient 3 0 0 Temperature Filter Coefficient Title: Temperature Filter Coefficient Location: 5D0C Usage: 4L80-E Transmission Parameters Tips: Conversion: Coefficient = X / 256 Coefficient 3 0 0 Torque Converter Slip Filter Coefficient Title: Torque Converter Slip Filter Coefficient Location: 5D0D Usage: 4L80-E Transmission Parameters Tips: Conversion: Coefficient = X / 256 Coefficient 3 0 0 Powertrain in Motion Flag Reset Time Title: Powertrain in Motion Flag Reset Time Location: 5D0E Usage: 4L80-E Transmission Parameters Tips: Minimum time to clear powertrain in motion flag. Conversion: msec. = 22.5 * X msec. 0 0 0 Disable Manual Shift Pattern Title: Disable Manual Shift Pattern Location: 5D0F Usage: 4L80-E Transmission Parameters Tips: Non-zero value disables manual shift pattern Conversion: 1 * X 0 0 0 Change in RPM Sample Rate Title: Change in RPM Sample Rate Location: 5D10 Usage: 4L80-E Transmission Parameters Tips: Sampling rate for monitoring change in engine RPM. Conversion: 1 * X 0 0 0 0 0 ==== 4L80-E VSS Parameters ======================= 4L80-E VSS Parameters 0 0 0 0 Maximum Time between Transmission and Input Pulses Title: Maximum Time between Transmission and Input Pulses Location: 5D11 Usage: 4L80-E VSS Parameters Tips: Conversion: Sec. = X / 40 Sec. 0 0 0 PLS/ REV Input Speed Callibration Title: PLS/ REV Input Speed Callibration Location: 5D12, 5D13 Usage: 4L80-E VSS Parameters Tips: Conversion: Integer Integer 2 3 0 0 Transmission Input Speed Filter Coefficient Title: Transmission Input Speed Filter Coefficient Location: 5D14 Usage: 4L80-E VSS Parameters Tips: Conversion: Coefficient = X / 256 Coefficient 3 0 0 Overdrive Ratio Title: Overdrive Ratio Location: 5D15, 5D16 Usage: 4L80-E VSS Parameters Tips: Conversion: Ratio = 0.000977 * X Ratio 3 0 0 Transmission Output Speed Filter Coefficient Title: Transmission Output Speed Filter Coefficient Location: 5D17 Usage: 4L80-E VSS Parameters Tips: Conversion: Coefficient = X / 256 Coefficient 3 0 0 Maximum Time for TOS Signal Title: Maximum Time for TOS Signal Location: 5D18 Usage: 4L80-E VSS Parameters Tips: Maximum time to wait for TOS signal before signal considered no longer present. Conversion: msec. = 25 * X msec. 0 0 0 RPM/VSS Ratio Title: RPM/VSS Ratio Location: 5D19, 5D1A Usage: 4L80-E VSS Parameters 8 x numeral gear ratio x 12 x 5280 Tips: Value = ------------------------------------------------ x 65536 512 x 60 x tire radius in inches x 2 x pi Conversion: Ratio = 0.000977 * X Ratio 3 0 0 VSS Filter Time Const. Title: VSS Filter Time Const. Location: 5D1B Usage: 4L80-E VSS Parameters Tips: Conversion: Coefficient = X / 256 Coefficient 3 0 0 4wd Low Reduction Ratio Title: 4wd Low Reduction Ratio Location: 5D16, 5D17 Usage: 4L80-E VSS Parameters Tips: Conversion: Ratio = 0.000977 * X Ratio 3 0 0 Scan Tool Speed Value Title: Scan Tool Speed Value Location: 5D1E, 5D1F Usage: 4L80-E VSS Parameters Tips: Conversion: Ratio = 0.000977 * X Ratio 3 0 0 MPH Filter Coefficient Title: MPH Filter Coefficient Location: 5D20 Usage: 4L80-E VSS Parameters Tips: Conversion: Coefficient = X / 256 Coefficient 3 0 0 0 0 ==== 4L80-E Kickdown Mode Parameters ================ 4L80-E Kickdown Mode Parameters 0 0 0 0 TPS to Enable Kickdown Mode Title: TPS to Enable Kickdown Mode Location: 5D21 Usage: 4L80-E Kickdown TPS Parameters Tips: Conversion: % TPS = 0.390625 * X % TPS 1 0 0 TPS to Disable Kickdown Mode Title: TPS to Disable Kickdown Mode Location: 5D22 Usage: 4L80-E Kickdown TPS Parameters Tips: Conversion: % TPS = 0.390625 * X % TPS 1 0 0 0 0 ==== 4L80-E Powertrain in Motion Parameters ============= 4L80-E Powertrain in Motion Parameters 0 0 0 0 Minimum Engine RPM Title: Minimum Engine RPM Location: 5D23, 5D24 Usage: 4L80-E Powertrain in Motion Parameters Tips: Minimum engine RPM for powertrain to be in motion. Conversion: RPM = (1 * X) / 8 RPM 0 0 0 Minimum TOS RPM Title: Minimum TOS RPM Location: 5D25, 5D26 Usage: 4L80-E Powertrain in Motion Parameters Tips: Minimum vehicle speed for powertrain to be in motion. Conversion: RPM = (1 * X) / 8 RPM 1 0 0 Minimum TIS RPM Title: Minimum TIS RPM Location: 5D27, 5D28 Usage: 4L80-E Powertrain in Motion Parameters Tips: Minimum turbine speed for powertrain to be in motion. Conversion: RPM = (1 * X) / 8 RPM 1 0 0 0 0 ==== 4L80-E Shift Pattern Parameters ================== 4L80-E Shift Pattern Parameters 0 0 0 0 Time to Limit Shifts after TCC Action Title: Time to Limit Shifts after TCC Action Location: 5D30 Usage: 4L80-E Shift Pattern Parameters Tips: Time threshold to prevent gear shifts while TCC being applied/released. Conversion: Sec. = X / 10 Sec. 1 0 0 Maximum Time to Limit 3 -> 2 Shift when Limiting 4 -> 2 Shift Title: Maximum Time to Limit 3 -> 2 Shift when Limiting 4 -> 2 Shift Location: 5D31 Usage: 4L80-E Shift Pattern Parameters Tips: Time thresholds to limit nuisance downshifts into 2nd from 4th gear. Conversion: Sec. = X / 10 Sec. 1 0 0 Lower 4 -> 2 Shift Limiting Time Title: Lower 4 -> 2 Shift Limiting Time Location: 5D32 Usage: 4L80-E Shift Pattern Parameters Tips: Time thresholds to limit nuisance downshifts into 2nd from 4th gear. Conversion: Sec. = X / 10 Sec. 1 0 0 Upper 4 -> 2 Shift Limiting Time Title: Upper 4 -> 2 Shift Limiting Time Location: 5D33 Usage: 4L80-E Shift Pattern Parameters Tips: Time thresholds to limit nuisance downshifts into 2nd from 4th gear. Conversion: Sec. = X / 10 Sec. 1 0 0 Lower Temperature for Preventing Shifts Title: Lower Temperature for Preventing Shifts Location: 5D34 Usage: 4L80-E Shift Pattern Parameters Tips: Temp window for preventing shifts into 4th. Conversion: Temp (C) = 0.750000 * X + -40 C 1 0 0 Upper Temperature for Preventing Shifts Title: Upper Temperature for Preventing Shifts Location: 5D35 Usage: 4L80-E Shift Pattern Parameters Tips: Temp window for preventing shifts into 4th. Conversion: Temp (C) = 0.750000 * X + -40 C 1 0 0 Lower Cold Shift Temperature Title: Lower Cold Shift Temperature Location: 5D36 Usage: 4L80-E Shift Pattern Parameters Tips: Window defining cold engine transmission shifts. Conversion: Temp (C) = 0.750000 * X + -40 C 1 0 0 Upper Cold Shift Temperature Title: Upper Cold Shift Temperature Location: 5D37 Usage: 4L80-E Shift Pattern Parameters Tips: Window defining cold engine transmission shifts. Conversion: Temp (C) = 0.750000 * X + -40 C 1 0 0 Baro Shift Point Gain Title: Baro Shift Point Gain Location: 5D38 Usage: 4L80-E Shift Pattern Parameters Tips: Conversion: Gain = (X - 128) / 128 Gain 0 0 0 0 ==== 4L80-E Manual Shift Parameters ================== 4L80-E Manual Shift Parameters 0 0 0 0 Downshift MPH 4 -> 3, 3 -> 2 Shift Title: Downshift MPH 4 -> 3, 3 -> 2 Shift Location: 5D3A Usage: 4L80-E Manual Shift Parameters Tips: Must be set to 0 MPH. Conversion: MPH = 0.5 * X MPH 0 0 0 Upshift MPH 2 -> 3, 3 -> 4 Shift Title: Upshift MPH 2 -> 3, 3 -> 4 Shift Location: 5D3B Usage: 4L80-E Manual Shift Parameters Tips: Must be set to 128 MPH Conversion: MPH = 0.5 * X MPH 0 0 0 MPH for Forced 1 -> 2 Shift Title: MPH for Forced 1 -> 2 Shift Location: 5D3C Usage: 4L80-E Manual Shift Parameters Tips: Conversion: MPH = 0.5 * X MPH 1 0 0 MPH for Forced 2 -> 1 Shift Title: MPH for Forced 2 -> 1 Shift Location: 5D3D Usage: 4L80-E Manual Shift Parameters Tips: Conversion: MPH = 0.5 * X MPH 1 0 0 0 0 ==== 4L80-E Garage Shift Parameters ================== 4L80-E Garage Shift Parameters 0 0 0 0 Maximum MPH for Low Speed Line Pressure Handling (P/N) Title: Maximum MPH for Low Speed Line Pressure Handling (P/N) Location: 5F11 Usage: 4L80-E Garage Shift Parameters Tips: Upper MPH threshold for low speed line pressure handling. Conversion: MPH = 0.5 * X MPH 0 0 0 Maximum MPH for Low Speed Line Pressure Handling (Drive) Title: Maximum MPH for Low Speed Line Pressure Handling (Drive) Location: 5F12 Usage: 4L80-E Garage Shift Parameters Tips: Upper MPH threshold for low speed line pressure handling. Conversion: MPH = 0.5 * X MPH 0 0 0 Added Low Speed Line Pressure (P/N) Title: Added Low Speed Line Pressure (P/N) Location: 5F13 Usage: 4L80-E Garage Shift Parameters Tips: Conversion: PSI = 1 * X PSI 0 0 0 Added Low Speed Line Pressure (Drive) Title: Added Low Speed Line Pressure (Drive) Location: 5F14 Usage: 4L80-E Garage Shift Parameters Tips: Conversion: PSI = 1 * X PSI 0 0 0 Added Low Speed Line Pressure (Reverse) Title: Added Low Speed Line Pressure (Reverse) Location: 5F15 Usage: 4L80-E Garage Shift Parameters Tips: Conversion: PSI = 1 * X PSI 0 0 0 0 0 ==== 4L80-E Line Pressure Parameters ================== 4L80-E Line Pressure Parameters 0 0 0 0 Maximum Allowed Line Pressure Title: Maximum Allowed Line Pressure Location: 5F2C Usage: 4L80-E Line Pressure Parameters Tips: Maximum allowed added line pressure. Conversion: PSI = 1 * X PSI 0 0 0 0 0 ==== Desired AFR Data Logging ===================== Desired AFR Data Logging 0 0 0 0 Desired AFR Title: Desired AFR Location: 5214, 5215 Usage: Desired AFR Data logging Tips: To data log "Desired AFR" instead of "Battery Volts", change the value at this location to $0249 "Desired AFR". Stock value is $00A7 "Battery Volts". Ads file can be changed to reflect this change, if desired. Conversion: None Hex 3 0 0 0 0 0 0x1 ==== Air Fuel Mode Words ========================= Air Fuel Mode Words 0x1 0x1 De-Latch Title: De-Latch Location: 400B-Bit 7 Usage: Air Fuel Mode Words Tips: Skip delta TPS check when already in deceleration enleanment. Checkmark to enable. I4 and V8 bins are normally off. V6 bins are normally on. 0x80 MAT Sensor Title: MAT Sensor Location: 400B-Bit 6 Usage: Air Fuel Mode Words Tips: Enables MAT sensor calibrations. Checkmark to enable MAT sensor calibrations. This can also be used for a IAT sensor. 0x40 180 Degree Offset Title: 180 Degree Offset Location: 400B-Bit 5 Usage: Air Fuel Mode Words Tips: Checkmark to enable 180 Degree Offset. I4 bins are normally on. V6 and V8 bins are normally off. 0x20 ASDF Crank Title: (Alternate Synchronous Double Fire) ASDF Crank Location: 400B-Bit 4 Usage: Air Fuel Mode Words Tips: Checkmark to enable ASDF Crank. I4 bins are normally on. V6 and V8 bins are normally off. 0x10 Acceleration Enrichment Limit Option Title: Acceleration Enrichment Limit Option Location: 400B-Bit 3 Usage: Air Fuel Mode Words Tips: Limits closed loop corrections when AE is in effect. Checkmark to enable the Acceleration Enrichment Limit Option. V6 bins are normally off. I4 and V8 bins are normally on. 0x8 Synchronous Fuel At Idle Title: Synchronous Fuel At Idle Location: 400B-Bit 2 Usage: Air Fuel Mode Words Tips: Checkmark to enable Synchronous Fuel At Idle. TBI only. 0x4 AIR Management Title: AIR Management Location: 400B-Bit 1 Usage: Air Fuel Mode Words Tips: Enables PCM A.I.R. control. Checkmark if you have a computer controlled Air Injection System (smog pump). 0x2 CPI/PFI Mode Title: CPI/PFI Mode Location: 400B-Bit 0 Usage: Air Fuel Mode Words Tips: To change between TBI and CPI/PFI injector firing strategies. Checkmark if you will be using Central Port Injection or Port Fuel Injection. TBI fires the injectors twice per crankshaft revolution. CPI/PFI fires the injectors once per revolution. PCM modifications are also required. 0x1 Charcoal Canister Purge Title: Charcoal Canister Purge Location: 400C-Bit 7 Usage: Air Fuel Mode Words Tips: Enables PCM CCP control. Checkmark if you will be using a computer controlled CCP valve. 0x80 Conditional Integrator Reset on BLM Cell Change Title: Conditional Integrator Reset on BLM Cell Change Location: 400C-Bit 6 Usage: Air Fuel Mode Words Tips: To have the integrator reset when a BLM cell change occurs. This mode is not used with 400C-Bit 4, but is used with 400C-Bit 5. Used on I4 engines, not used on V6 or V8 engines. 0x40 Integrator Reset if Acceleration Enrichment Title: Integrator Reset if Acceleration Enrichment Location: 400C-Bit 5 Usage: Air Fuel Mode Words Tips: To have the integrator reset when Acceleration Enrichment (AE) occurs. This mode is not used with 400C-Bit 4, but is used with 400C-Bit 6. Used on I4 engines, not used on V6 or V8 engines. 0x20 Integrator Reset if BLM Cell Change Title: Integrator Reset if BLM Cell Change Location: 400C-Bit 4 Usage: Air Fuel Mode Words Tips: To have the integrator reset when a BLM change occurs. This mode is not used with 400C-Bit 6 or 400C-Bit 5. Used on V6 and V8 engines, not used on I4 engines. 0x10 Alternate Synchronous Double Fire Title: Alternate Synchronous Double Fire Location: 400C-Bit 3 Usage: Air Fuel Mode Words Tips: Checkmark to enable ASDF. I4 bins are normally on. V6 and V8 bins are normally off. 0x8 Crank Fuel All Injectors Each DRP Title: Crank Fuel All Injectors Each DRP Location: 400C-Bit 2 Usage: Air Fuel Mode Words Tips: Enables fuel from all injectors, with each distributor reference pulse (DRP), while starting. Most bin's have this enabled, some do not. 0x4 Error 44/45 BLM Limit Title: Error 44/45 BLM Limit Location: 400C-Bit 1 Usage: Air Fuel Mode Words Tips: Used for V8 and V6 engines, not used for I4 engines. 0x2 Synchronous MAP Sensor Reads Title: Synchronous MAP Sensor Reads Location: 400C-Bit 0 Usage: Air Fuel Mode Words Tips: Synchronizes MAP sensor readings with distributor reference pulses (DRP). 0x1 Single Pass EGR Test Title: Single Pass EGR Test Location: 400D-Bit 7 Usage: Air Fuel Mode Words Tips: Checkmark to enable. Most bin's have this enabled. 0x80 VATS Title: VATS Location: 400D-Bit 6 Usage: Air Fuel Mode Words Tips: Checkmark to enable VATS. Vehicle Anti Theft System (VATS). 0x40 Use L478B Table for %EGR Title: Use L478B Table for %EGR Location: 400D-Bit 5 Usage: Air Fuel Mode Words Tips: Checkmark to use table L478B "EGR Fuel Reduction vs. RPM vs. Vacuum". Use with PCM controlled EGR. 0x20 EGR Off at Idle Title: EGR Off at Idle Location: 400D-Bit 4 Usage: Air Fuel Mode Words Tips: Checkmark to disable EGR at idle. 0x10 EGR Off in Open Loop Title: EGR Off in Open Loop Location: 400D-Bit 3 Usage: Air Fuel Mode Words Tips: Checkmark to disable EGR in open loop. 0x8 Backpressure EGR Title: Backpressure EGR Location: 400D-Bit 2 Usage: Air Fuel Mode Words Tips: Checkmark if a backpressure EGR is in use. TBI engines use backpressure EGR. 0x4 Linear EGR/EVRV EGR Title: Linear EGR/EVRV EGR Location: 400D-Bit 1 Usage: Air Fuel Mode Words Tips: Checkmark if a linear EGR valve is in use. No checkmark if EGR used, is controlled by a Electronic Vacuum Regulator Valve. 0x2 Open Loop AFR Enable Title: Open Loop AFR Enable Location: 400D-Bit 0 Usage: Air Fuel Mode Words Tips: Enables use of L4BBC "Open Loop AFR vs. Temperature vs. Vacuum" table for closed loop fueling, when coolant temperature less than L48CF "Maximum Temperature for AFR Lookup in Closed Loop". Can be used for a "lean cruise" or other specific fueling conditions. Also used for VE tuning. 0x1 Latch Error 45 Title: Latch Error 45 Location: 400E-Bit 5 Usage: Air Fuel Mode Words Tips: Checkmark to enable. 0x20 Use Async Short BPW Offset vs. BPW Table Title: Use Async Short BPW Offset vs. BPW Table Location: 400E-Bit 4 Usage: Air Fuel Mode Words Tips: Enable to use L4977 "Async Short BPW Offset vs. BPW" table, with asynchronous fueling. No checkmark to use L496F "Async Short BPW Offset Bias". Used with PFI and CPI. Not used with TBI. 0x10 Variable Manifold Tuning Control Title: Variable Manifold Tuning Control Location: 400E-Bit 3 Usage: Air Fuel Mode Words Tips: CPI V6 only. 0x8 Shift Light Enable Title: Shift Light Enable Location: 400E-Bit 2 Usage: Air Fuel Mode Words Tips: Enables shift light for manual transmission and disables automatic transmission controls. Must be enabled for manual transmission and for non electronic auto transmissions. Table L5D56 "Upshift RPM vs. Shift" must be set to zero if using a manual transmission or auto transmission without electronic controls. 0x4 Use MAP/ Baro Ratio for DFCO Title: Use MAP/ Baro Ratio for DFCO Location: 400E-Bit 1 Usage: Air Fuel Mode Words Tips: Used with PFI I4 engines. Use Altitude CMAP vs. MAP Load for Fuel Curve Hysteresis Pair 0x2 Use MAP/ Baro Ratio for BLM Cell Bounds Title: Use MAP/ Baro Ratio for BLM Cell Bounds Location: 400E-Bit 0 Usage: Air Fuel Mode Words Tips: Used with CPI V6 engines. Use Altitude CMAP vs. MAP Load and AD MAP for BLM Enable 0x1 Manual Transmission Title: Manual Transmission Location: 400F-Bit 7 Usage: Air Fuel Mode Words Tips: Checkmark for manual transmission. No checkmark for TCC control. Enable if using a TH 350 or TH 400 transmission without TCC. Table L5D56 "Upshift RPM vs. Shift" must be set to zero if using a manual transmission or auto transmission without electronic controls. 0x80 Torque Converter Clutch Only Title: Torque Converter Clutch Only Location: 400F-Bit 6 Usage: Air Fuel Mode Words Tips: Checkmark for manual transmissions and for TH 350, TH 400, 200R4, and 700R4 auto transmissions with or without TCC. No checkmark for 4L80-E transmissions. Table L5D56 "Upshift RPM vs. Shift" must be set to zero if using a manual transmission or auto transmission without electronic controls. 0x40 Catalytic Converter Overheat Protection Title: Catalytic Converter Overheat Protection Location: 400F-Bit 4 Usage: Air Fuel Mode Words Tips: Checkmark to enable catalytic converter overheat protection. 0x10 Burst Knock Retard Title: Burst Knock Retard Location: 400F-Bit 3 Usage: Air Fuel Mode Words Tips: Checkmark to enable. 0x8 A/C Clutch Control/Variable Manifold Tune Control Title: A/C Clutch Control/Variable Manifold Tune Control Location: 400F-Bit 2 Usage: Air Fuel Mode Words Tips: Checkmark for A/C clutch control. No checkmark for variable manifold control. Not used for CPI V6. 0x4 Governor Option Title: Governor Option Location: 400F-Bit 0 Usage: Air Fuel Mode Words Tips: Checkmark to enable "Governor Parameters". No checkmark to use "Speed and RPM Limiter Parameters". 0x1 0x1 ==== BLM Parameters ============================ BLM Parameters 0x1 0x1 Separate BLM Park/ Neutral Cells Title: Separate BLM Park/ Neutral Cells Location: 48F4 Bit 2 Usage: BLM Parameters Tips: Enables more BLM cells. 0x4 Separate BLM A/C Idle Cells Title: Separate BLM A/C Idle Cells Location: 48F4 Bit 1 Usage: BLM Parameters Tips: Enables more BLM cells. 0x2 Separate BLM Idle Cells Title: Separate BLM Idle Cells Location: 48F4 Bit 0 Usage: BLM Parameters Tips: Enables more BLM cells. 0x1 0x1 ==== IAC Parameters ============================ IAC Parameters 0x1 0x1 Stall Saver Activation Thresholds Title: Stall Saver Activation Thresholds Location: 4E8D Bit 7 Usage: IAC Parameters Tips: 1 = Stall saver thresholds are default RPM. 0 = Stall saver thresholds are based on requested RPM. If not enabled, qualifiers are % multipliers for desired idle to obtain RPM threshold. If enabled, qualifiers are RPM thresholds. 0x80 MAT Table for A/C Transitions Title: MAT Table for A/C Transitions Location: 4E8D Bit 6 Usage: IAC Parameters Tips: Enable to use table L4F15 "IAC Flow Difference for A/C Transition vs. MAT" for A/C on/off transitions. 0x40 Initiate Integral with Calibration Const. Not Running Title: Initiate Integral with Calibration Const. Not Running Location: 4E8D Bit 5 Usage: IAC Parameters Tips: ???? 0x20 A/C High Pressure Switch Title: A/C High Pressure Switch Location: 4E8D Bit 4 Usage: IAC Parameters Tips: Enable if using a A/C high pressure switch. 0x10 Use A/C Off Idle Integral Cells Title: Use A/C Off Idle Integral Cells Location: 4E8D Bit 3 Usage: IAC Parameters Tips: Use A/C off idle integral cells to reset A/C on integral cells. 0x8 Throttle Kicker Enable Title: Throttle Kicker Enable Location: 4E8D Bit 2 Usage: IAC Parameters Tips: 0x4 Use Extended Throttle Cracker in DFCO Title: Use Extended Throttle Cracker in DFCO Location: 4E8D Bit 1 Usage: IAC Parameters Tips: Enable to use Extended Throttle Cracker while in DFCO 0x2 Closed Loop Idle Title: Closed Loop Idle Location: 4E8D Bit 0 Usage: IAC Parameters Tips: 1 = Manual transmission, disable closed loop idle if qualifiers not met. 0 = Auto transmission, enable closed loop idle if RPM low. 0x1 Power Steering Switch Title: Power Steering Switch Location: 4E8E Bit 1 Usage: IAC Parameters Tips: Enable if power steering pressure switch is in use. 0x2 Initiate 16 Bit Integrals from 8 Bit Warm Cells Title: Initiate 16 Bit Integrals from 8 Bit Warm Cells Location: 4E8E Bit 0 Usage: IAC Parameters Tips: ???? 0x1 0x1 ==== Error Codes ============================== Error Codes 0x1 0x1 Code 13 O2 Sensor Failure Title: Code 13 O2 Sensor Failure Location: 5B00 Bit 7 Usage: Enable error code 13. Tips: 0x80 Code 14 Coolant Sensor High Temp Title: Code 14 Coolant Sensor High Temp Location: 5B00 Bit 6 Usage: Enable error code 14. Tips: 0x40 Code 15 Coolant Sensor Low Temp Title: Code 15 Coolant Sensor Low Temp Location: 5B00 Bit 5 Usage: Enable error code 15. Tips: 0x20 Code 16 Vehical Speed Sensor Failure Title: Code 16 Vehical Speed Sensor Failure Location: 5B00 Bit 4 Usage: Enable error code 16. Tips: 0x10 Code 21 TPS Sensor High Title: Code 21 TPS Sensor High Location: 5B00 Bit 0 Usage: Enable error code 21. Tips: 0x1 Code 22 TPS Sensor Low Title: Code 22 TPS Sensor Low Location: 5B01 Bit 7 Usage: Enable error code 22. Tips: 0x80 Code 23 MAT Sensor Low Title: Code 23 MAT Sensor Low Location: 5B01 Bit 6 Usage: Enable error code 23. Tips: 0x40 Code 24 Transmission Output Speed Low Title: Code 24 Transmission Output Speed Low Location: 5B01 Bit 5 Usage: Enable error code 24. Tips: 0x20 Code 25 MAT Sensor High Title: Code 25 MAT Sensor High Location: 5B01 Bit 4 Usage: Enable error code 25. Tips: 0x10 Code 28 Transmission Pressure Manifold Title: Code 28 Transmission Pressure Manifold Location: 5B01 Bit 1 Usage: Enable error code 28. Tips: 0x2 Code 31 Governor Failure Title: Code 31 Governor Failure Location: 5B02 Bit 7 Usage: Enable error code 31. Tips: 0x80 Code 32 EGR Failure Title: Code 32 EGR Failure Location: 5B02 Bit 6 Usage: Enable error code 32. Tips: 0x40 Code 33 MAP Sensor High Title: Code 33 MAP Sensor High Location: 5B02 Bit 5 Usage: Enable error code 33. Tips: 0x20 Code 34 MAP Sensor Low Title: Code 34 MAP Sensor Low Location: 5B02 Bit 4 Usage: Enable error code 34. Tips: 0x10 Code 35 IAC Failure Title: Code 35 IAC Failure Location: 5B02 Bit 3 Usage: Enable error code 35. Tips: 0x8 Code 36 Throttle Kicker Failure Title: Code 36 Throttle Kicker Failure Location: 5B02 Bit 2 Usage: Enable error code 36. Tips: 0x4 Code 37 TCC Brake Switch Stuck On Title: Code 37 TCC Brake Switch Stuck On Location: 5B02 Bit 1 Usage: Enable error code 37. Tips: 0x2 Code 38 TCC Brake Switch Stuck Off Title: Code 38 TCC Brake Switch Stuck Off Location: 5B02 Bit 0 Usage: Enable error code 38. Tips: 0x1 Code 39 TCC Stuck Off Title: Code 39 TCC Stuck Off Location: 5B03 Bit 7 Usage: Enable error code 39. Tips: 0x80 Code 41 Cam Pulse Sensor Failure Title: Code 41 Cam Pulse Sensor Failure Location: 5B03 Bit 6 Usage: Enable error code 41. Tips: 0x40 Code 42 Ignition Error Title: Code 42 Ignition Error Location: 5B03 Bit 5 Usage: Enable error code 42. Tips: 0x20 Code 43 Knock Sensor Circuit Failure Title: Code 43 Knock Sensor Circuit Failure Location: 5B03 Bit 4 Usage: Enable error code 43. Tips: 0x10 Code 44 O2 Sensor Lean Title: Code 44 O2 Sensor Lean Location: 5B03 Bit 3 Usage: Enable error code 44. Tips: 0x8 Code 45 O2 Sensor Rich Title: Code 45 O2 Sensor Rich Location: 5B03 Bit 2 Usage: Enable error code 45. Tips: 0x4 Code 46 VATS Failure Title: Code 46 VATS Failure Location: 5B03 Bit 1 Usage: Enable error code 46. Tips: 0x2 Code 51 EPROM Checksum Failure Title: Code 51 EPROM Checksum Failure Location: 5B04 Bit 5 Usage: Enable error code 51. Tips: 0x20 Code 52 System Voltage High (Long Test) Title: Code 52 System Voltage High (Long Test) Location: 5B04 Bit 4 Usage: Enable error code 52. Tips: 0x10 Code 53 System Voltage High Title: Code 53 System Voltage High Location: 5B04 Bit 3 Usage: Enable error code 53. Tips: 0x8 Code 54 Fuel Pump Relay Failure Title: Code 54 Fuel Pump Relay Failure Location: 5B04 Bit 2 Usage: Enable error code 54. Tips: 0x4 Code 55 PCM Failure Title: Code 55 PCM Failure Location: 5B04 Bit 1 Usage: Enable error code 55. Tips: 0x2 Code 58 Transmission Temperature High Title: Code 58 Transmission Temperature High Location: 5B05 Bit 6 Usage: Enable error code 58. Tips: 0x40 Code 59 Transmission Temperature Low Title: Code 59 Transmission Temperature Low Location: 5B05 Bit 5 Usage: Enable error code 59. Tips: 0x20 Code 63 Barometric Pressure Sensor High Title: Code 63 Barometric Pressure Sensor High Location: 5B05 Bit 2 Usage: Enable error code 63. Tips: 0x4 Code 64 Barometric Pressure Sensor Low Title: Code 64 Barometric Pressure Sensor Low Location: 5B05 Bit 1 Usage: Enable error code 64. Tips: 0x2 Code 66 3 -> 2 Shift Solenoid Failure Title: Code 66 3 -> 2 Shift Solenoid Failure Location: 5B06 Bit 7 Usage: Enable error code 66. Tips: 0x80 Code 67 TCC Solenoid Failure Title: Code 67 TCC Solenoid Failure Location: 5B06 Bit 6 Usage: Enable error code 67. Tips: 0x40 Code 68 Transmission Slipping Title: Code 68 Transmission Slipping Location: 5B06 Bit 5 Usage: Enable error code 68. Tips: 0x20 Code 69 TCC Stuck On Title: Code 69 TCC Stuck On Location: 5B06 Bit 4 Usage: Enable error code 69. Tips: 0x10 Code 71 Transmission Input Speed Low Title: Code 71 Transmission Input Speed Low Location: 5B06 Bit 3 Usage: Enable error code 71. Tips: 0x8 Code 72 Transmission Output Speed Loss Title: Code 72 Transmission Output Speed Loss Location: 5B06 Bit 2 Usage: Enable error code 72. Tips: 0x4 Code 73 Pressure Control Solenoid Title: Code 73 Pressure Control Solenoid Location: 5B06 Bit 1 Usage: Enable error code 73. Tips: 0x2 Code 74 Transmission Input Speed Sensor Title: Code 74 Transmission Input Speed Sensor Location: 5B06 Bit 0 Usage: Enable error code 74. Tips: 0x1 Code 75 System Voltage Low Title: Code 75 System Voltage Low Location: 5B07 Bit 7 Usage: Enable error code 75. Tips: 0x80 Code 77 MNP Switch Title: Code 77 MNP Switch Location: 5B07 Bit 5 Usage: Enable error code 77. Tips: 0x20 Code 79 Transmission Overheat Title: Code 79 Transmission Overheat Location: 5B07 Bit 3 Usage: Enable error code 79. Tips: 0x8 Code 81 2 -> 3 Shift Solenoid Failure Title: Code 81 2 -> 3 Shift Solenoid Failure Location: 5B07 Bit 2 Usage: Enable error code 81. Tips: 0x4 Code 82 1 -> 2 Shift Solenoid Failure Title: Code 82 1 -> 2 Shift Solenoid Failure Location: 5B07 Bit 1 Usage: Enable error code 82. Tips: 0x2 Code 83 TCC PWM Solenoid Failure Title: Code 83 TCC PWM Solenoid Failure Location: 5B07 Bit 0 Usage: Enable error code 83. Tips: 0x1 Code 85 Undefined Shift Solenoid Failure Title: Code 85 Undefined Shift Solenoid Failure Location: 5B08 Bit 6 Usage: Enable error code 85. Tips: 0x40 Code 86 2 -> 3 Shift Solenoid Stuck On Title: Code 86 2 -> 3 Shift Solenoid Stuck On Location: 5B08 Bit 5 Usage: Enable error code 86. Tips: 0x20 Code 87 2 -> 3 Shift Solenoid Stuck Off Title: Code 87 2 -> 3 Shift Solenoid Stuck Off Location: 5B08 Bit 4 Usage: Enable error code 87. Tips: 0x10 Code 89 Maximum Adaptive Long Shift Title: Code 89 Maximum Adaptive Long Shift Location: 5B08 Bit 2 Usage: Enable error code 89. Tips: 0x4 0x1 ==== 4L80-E Transmission Parameters ================== 4L80-E Transmission Parameters 0x1 0x1 Force 2nd Gear if in D2 and not Manual Title: Force 2nd Gear if in D2 and not Manual Location: 5D02 Bit 5 Usage: 4L80-E Transmission Parameters Tips: 0x20 Output Speed Not from DRAC Title: Output Speed Not from DRAC Location: 5D02 Bit 4 Usage: 4L80-E Transmission Parameters Tips: Digital Ratio Adapter Controller 0x10 Baro and MAP Sensor Used Title: Baro and MAP Sensor Used Location: 5D02 Bit 2 Usage: 4L80-E Transmission Parameters Tips: 1 = Use MAP and Baro, 0 = MAP only. 0x4 Allow TPS Hysteresis buffer every 25 msec. Title: Allow TPS Hysteresis buffer every 25 msec. Location: 5D02 Bit 0 Usage: 4L80-E Transmission Parameters Tips: 0x1 Filter 4WD Low Input Title: Filter 4WD Low Input Location: 5D03 Bit 4 Usage: 4L80-E Transmission Parameters Tips: 0x10 Filter Cruise Control Input Title: Filter Cruise Control Input Location: 5D03 Bit 3 Usage: 4L80-E Transmission Parameters Tips: 0x8 Filter A/C Input Title: Filter A/C Input Location: 5D03 Bit 2 Usage: 4L80-E Transmission Parameters Tips: 0x4 Filter Shifter Pattern Inputs Title: Filter Shifter Pattern Inputs Location: 5D03 Bit 1 Usage: 4L80-E Transmission Parameters Tips: 0x2 Filter Range Shifter Inputs Title: Filter Range Shifter Inputs Location: 5D03 Bit 0 Usage: 4L80-E Transmission Parameters Tips: 0x1 0x1 1 0 0 1 0 0 2 0.000000 255.000000 1 ==== CCP Parameters ============================ CCP Parameters 1 0 0 1 0 0 2 0.000000 255.000000 1 1 0 0 1 0 0 2 0.000000 255.000000 1 CCP DC vs. Air Flow (Closed Loop) Title: CCP DC vs. Air Flow (Closed Loop) Location: 4036 Usage: CCP Parameters Tips: CCP = Charcoal Canister Purge. Conversion: % DC = 0.3905555 * X % DC 1 1000.000000 0 0 Air Flow 17 1000.000000 4 0 0 % DC 1 0.000000 255.000000 1 CCP DC Minimum vs. Air Flow (Closed Loop) Title: CCP DC Minimum vs. Air Flow (Closed Loop) Location: 4047 Usage: CCP Parameters Tips: CCP = Charcoal Canister Purge. Conversion: % DC = 0.3905555 * X % DC 1 1000.000000 0 0 Air Flow 17 1000.000000 4 0 0 % DC 1 0.000000 255.000000 1 CCP Purge Allowed vs. BLM Cell Title: CCP Purge Allowed vs. BLM Cell Location: 4058 Usage: CCP Parameters Tips: CCP = Charcoal Canister Purge. 0 = False 1 = True Conversion: None Yes/ No 1 1000.000000 2 0 0 BLM Cell 21 1000.000000 4 0 0 Yes/ No 1 0.000000 255.000000 2 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 ==== CAT Overheat Protection Parameters ============== CAT Overheat Protection Parameters 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 CAT Temperature Filter Coefficient vs. Air Flow Title: CAT Temperature Filter Coefficient vs. Air Flow Location: 4077 Usage: CAT Overheat Protection Parameters Tips: Conversion: % = 0.3905555 * X % 1 1000.000000 0 0 Air Flow 17 1000.000000 4 0 0 % 1 0.000000 255.000000 1 CAT Endo/ Exothermic Reaction Temp vs. AFR Title: CAT Endo/ Exothermic Reaction Temp vs. AFR Location: 4088 Usage: CAT Overheat Protection Parameters Tips: Conversion: High Temp (C) = 3 * X + 300.00 C 1 1000.000000 0 0 AFR 7 1000.000000 4 0 0 C 2 0.000000 255.000000 1 CAT Reaction Temperature vs. RPM vs. Air Flow Title: CAT Reaction Temperature vs. RPM vs. Air Flow Location: 4092 Usage: CAT Overheat Protection Parameters Tips: Conversion: Mid Temp (C) = X + 300.00 Air Flow 17 1000.000000 4 0 0 RPM 9 1000.000000 4 0 0 C 2 0.000000 255.000000 2 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 ==== Spark Advance Tables ======================== Spark Advance Tables 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 Main Spark Table vs. MAP vs. RPM (Open Throttle) Title: Main Spark Table vs. MAP vs. RPM (Open Throttle) Location: 4167 Usage: Spark Advance Tables Tips: Main spark advance when throttle is open. This table automatically adjusts for L413B "Main Spark Bias". This table represents "Total Spark Advance". Conversion: Spark Table - Bias = 0.351563 * ( X - Y ) Kpa 17 1000.000000 4 0 0 RPM 17 1000.000000 4 0 0 deg 1 0.000000 255.000000 1 Main Spark Table vs. MAP vs. RPM (Closed Throttle) Title: Main Spark Table vs. MAP vs. RPM (Closed Throttle) Location: 428B Usage: Spark Advance Tables Tips: Main spark advance when throttle is closed. This table automatically adjusts for L413B "Main Spark Bias". This table represents "Total Spark Advance". Conversion: Spark Table - Bias = 0.351563 * ( X - Y ) Kpa 17 1000.000000 4 0 0 RPM 17 1000.000000 4 0 0 deg 1 0.000000 255.000000 1 CTS Spark Advance Compensation vs. Vacuum vs. Temperature Title: CTS Spark Advance Compensation vs. Vacuum vs. Temperature Location: 43B0 Usage: Spark Advance Tables Tips: Adjusts spark advance for different engine temperatures. CTS = Coolant Temperature Sensor. This value is added to the value in the "Main Spark Tables". This table automatically adjusts for L413C "Coolant Spark Bias". Conversion: Spark Table - Bias = 0.351563 * (X - Y) vac 9 1000.000000 4 0 0 C 15 1000.000000 4 0 0 deg 1 0.000000 255.000000 1 MAT Spark Advance Compensation vs. Vacuum vs. Temperature Title: MAT Spark Advance Compensation vs. Vacuum vs. Temperature Location: 443B Usage: Spark Advance Tables Tips: Adjusts spark advance for different MAT temperatures. MAT = Manifold Air Temperature. This value is added to the value in the "Main Spark Tables". This table automatically adjusts for L413F "MAT Spark Advance". Conversion: Spark Table - Bias = 0.351563 * (X - Y) vac 12 1000.000000 4 0 0 C MAT 8 1000.000000 4 0 0 deg 1 0.000000 255.000000 1 MAT Multiplier for Negative Spark Advance vs. MAP Title: MAT Multiplier for Negative Spark Advance vs. MAP Location: 449B Usage: Spark Advance Tables Tips: Conversion: % = X / 2.56 % 1 1000.000000 4 0 0 Kpa 17 1000.000000 4 0 0 % 1 0.000000 255.000000 1 MAT Multiplier for Positive Spark Advance vs. MAP Title: MAT Multiplier for Positive Spark Advance vs. MAP Location: 44AC Usage: Spark Advance Tables Tips: Conversion: % = X / 2.56 % 1 1000.000000 0 0 Kpa 17 1000.000000 4 0 0 % 1 0.000000 255.000000 1 PE Spark vs. RPM Title: PE Spark vs. RPM Location: 44BD Usage: Spark Advance Tables Tips: Adds spark while in PE mode. PE = Power Enrichment Conversion: Spark (deg) = 0.351563 * X deg 1 1000.000000 0 0 RPM 17 1000.000000 4 0 0 deg 1 0.000000 255.000000 1 Spark Advance Decay Period vs. Air Flow Title: Spark Advance Decay Period vs. Air Flow Location: 44CE Usage: Spark Advance Tables Tips: Conversion: Sec. = 0.0125 * X Sec. 1 1000.000000 0 0 Air Flow 5 1000.000000 4 0 0 Sec. 4 0.000000 255.000000 1 Altitude Spark Advance Correction vs. Baro vs. Vacuum Title: Altitude Spark Advance Correction vs. Baro vs. Vacuum Location: 44D6 Usage: Spark Advance Tables Tips: Adjusts spark advance for altitude. This value is added to the value in the "Main Spark Tables". This table automatically adjusts for L413D "Altitude Spark Bias". Used with back pressure EGR. Conversion: Spark Table - Bias = 0.351563 * (X - Y) vac 6 1000.000000 4 0 0 Baro 4 1000.000000 4 0 0 deg 1 0.000000 255.000000 1 Idle Overspeed Spark Retard vs. RPM Error Title: Idle Overspeed Spark Retard vs. RPM Error Location: 44EF Usage: Spark Advance Tables Tips: Idle overspeed/ underspeed corrections. Subtracted from spark advance to lower engine speed. This is why timing is constantly moving around at idle. Conversion: Spark (deg) = 0.351563 * X deg 1 1000.000000 0 0 RPM Error 7 1000.000000 4 0 0 deg 1 0.000000 255.000000 1 Idle Overspeed Spark Multiplier vs. MAP Title: Idle Overspeed Spark Multiplier vs. MAP Location: 44F7 Usage: Spark Advance Tables Tips: Idle overspeed/ underspeed corrections. Subtracted from spark advance to lower engine speed. This is why timing is constantly moving around at idle. Conversion: Multiplier = 0.003906 * X Multiplier 1 1000.000000 0 0 Kpa 9 1000.000000 4 0 0 Multiplier 3 0.000000 255.000000 1 Idle Underspeed Spark Advance vs. RPM Error Title: Idle Underspeed Spark Advance vs. RPM Error Location: 4501 Usage: Spark Advance Tables Tips: Idle overspeed/ underspeed corrections. Added to spark advance to raise engine speed. This is why timing is constantly moving around at idle. Conversion: Spark (deg) = 0.351563 * X deg 1 1000.000000 0 0 RPM Error 7 1000.000000 4 0 0 deg 1 0.000000 255.000000 1 Idle Underspeed Spark Multiplier vs. MAP Title: Idle Underspeed Spark Multiplier vs. MAP Location: 4509 Usage: Spark Advance Tables Tips: Idle overspeed/ underspeed corrections. Added to spark advance to raise engine speed. This is why timing is constantly moving around at idle. Conversion: Multiplier = 0.003906 * X Multiplier 1 1000.000000 0 0 Kpa 9 1000.000000 4 0 0 Multiplier 3 0.000000 255.000000 1 Transient RPM Idle Spark Correction vs. RPM Ratio Title: Transient RPM Idle Spark Correction vs. RPM Ratio Location: 4519 Usage: Spark Advance Tables Tips: This value is added to the value in the "Main Spark Tables". This table automatically adjusts for L4512 "Transient RPM Idle Spark Correction Bias". Conversion: Spark Table - Bias = 0.351563 * (X - Y) deg 1 1000.000000 0 0 RPM Ratio 17 1000.000000 4 0 0 deg 1 0.000000 255.000000 1 Startup Spark vs. Temperature Title: Startup Spark vs. Temperature Location: 452B Usage: Spark Advance Tables Tips: Startup spark adder. Conversion: Spark (deg) = 0.351563 * X deg 1 1000.000000 0 0 C 9 1000.000000 4 0 0 deg 1 0.000000 255.000000 1 Startup Spark Decay Rate vs. Temperature Title: Startup Spark Decay Rate vs. Temperature Location: 4535 Usage: Spark Advance Tables Tips: Time for startup spark to end. Conversion: Sec. = 1 * X Sec. 1 1000.000000 0 0 C 9 1000.000000 4 0 0 Sec. 1 0.000000 255.000000 1 Startup Spark Decay Multiplier vs. Temperature Title: Startup Spark Decay Multiplier vs. Temperature Location: 453F Usage: Spark Advance Tables Tips: Conversion: Multiplier = 0.003906 * X Multiplier 1 1000.000000 0 0 C 9 1000.000000 4 0 0 Multiplier 3 0.000000 255.000000 1 Spark Latency Correction vs. RPM Title: Spark Latency Correction vs. RPM Location: 4549 Usage: Spark Advance Tables Tips: Conversion: uSec. = 15.26 * X uSec. 1 1000.000000 0 0 RPM 13 1000.000000 4 0 0 uSec. 0 0.000000 255.000000 1 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 ==== Pseudo-Baro Parameters ====================== Pseudo-Baro Parameters 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 Baro Correction Factor vs. RPM vs. TPS Title: Baro Correction Factor vs. RPM vs. TPS Location: 4559 Usage: Pseudo-Baro Parameters Tips: Conversion: Kpa = 0.369000 * X % TPS 6 1000.000000 4 0 0 RPM 7 1000.000000 4 0 0 Kpa 1 0.000000 255.000000 1 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 ==== Spark Retard Tables ========================= Spark Retard Tables 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 Maximum PE Knock Retard vs. RPM Title: Maximum PE Knock Retard vs. RPM Location: 4583 Usage: Spark Retard Tables Tips: PE = Power Enrichment. Limits knock retard in PE mode. Conversion: Spark (deg) = 0.351563 * X deg 1 1000.000000 0 0 RPM 8 1000.000000 4 0 0 deg 1 0.000000 255.000000 1 Maximum Knock Retard vs. Vacuum Title: Maximum Knock Retard vs. Vacuum Location: 458B Usage: Spark Retard Tables Tips: Limits knock retard while not in PE. Conversion: Spark (deg) = 0.351563 * X deg 1 1000.000000 0 0 Vacuum 7 1000.000000 4 0 0 deg 1 0.000000 255.000000 1 Knock Retard Attack Rate vs. RPM Title: Knock Retard Attack Rate vs. RPM Location: 4592 Usage: Spark Retard Tables Tips: Conversion: mSec. = .0225 * X mSec. 1 1000.000000 0 0 RPM 17 1000.000000 4 0 0 mSec. 1 0.000000 255.000000 1 Knock Retard Recovery Rate vs. RPM Title: Knock Retard Recovery Rate vs. RPM Location: 45A3 Usage: Spark Retard Tables Tips: Conversion: % per Sec. = 1.953 * X % per Sec. 1 1000.000000 4 0 0 RPM 17 1000.000000 4 0 0 % per Sec. 1 0.000000 255.000000 1 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 ==== Low Octane Retard Parameters ================== Low Octane Retard Parameters 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 Low Octane Retard Multiplier vs. RPM Title: Low Octane Retard Multiplier vs. RPM Location: 45BC Usage: Low Octane Retard Parameters Tips: Applied to base retard. Conversion: % Multiplier = X / 2.56 % Multiplier 1 1000.000000 0 0 RPM 9 1000.000000 4 0 0 % Multiplier 1 0.000000 255.000000 1 Low Octane Retard Multiplier vs. MAP Title: Low Octane Retard Multiplier vs. MAP Location: 45C5 Usage: Low Octane Retard Parameters Tips: Applied to base retard. Conversion: % Multiplier = X / 2.56 % Multiplier 1 1000.000000 0 0 Kpa 17 1000.000000 4 0 0 % Multiplier 1 0.000000 255.000000 1 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 ==== Knock Retard Parameters ====================== Knock Retard Parameters 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 Minimum Knock Counts vs. RPM Title: Minimum Knock Counts vs. RPM Location: 45D9 Usage: Knock Retard Parameters Tips: Subtracted out from knock counts before store. Conversion: Counts = 1 * X Counts 1 1000.000000 0 0 RPM 65 1000.000000 4 0 0 Counts 0 0.000000 255.000000 1 Knock Count Bias vs. RPM Title: Knock Count Bias vs. RPM Location: 461A Usage: Knock Retard Parameters Tips: Conversion: Counts = 1 * X Counts 1 1000.000000 0 0 RPM 65 1000.000000 4 0 0 Counts 0 0.000000 255.000000 1 Knock Window Delay Time vs. RPM Title: Knock Window Delay Time vs. RPM Location: 465B Usage: Knock Retard Parameters Tips: Conversion: msec. = X / 131.072 msec. 1 1000.000000 0 0 RPM 65 1000.000000 4 0 0 msec. 3 0.000000 255.000000 1 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 ==== Burst Knock Parameters ======================= Burst Knock Parameters 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 Burst Knock Retard vs. Temperature Title: Burst Knock Retard vs. Temperature Location: 46E2 Usage: Burst Knock Parameters Tips: Conversion: Spark (deg) = 0.351563 * X deg 1 1000.000000 0 0 C 8 1000.000000 4 0 0 deg 1 0.000000 255.000000 1 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 ==== Dynamic Spark Parameters ===================== Dynamic Spark Parameters 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 Filter Coefficient vs. TPS Title: Filter Coefficient vs. TPS Location: 46F2 Usage: Dynamic Spark Parameters Tips: Engine spark advance used with manual transmissions. Conversion: % Coefficient = 0.3905555 * X % Coefficient 1 1000.000000 0 0 % TPS 5 1000.000000 4 0 0 % Coefficient 0 0.000000 255.000000 1 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 ==== EGR Enable Tables ========================== EGR Enable Tables 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 Desired EGR vs. RPM vs. Vacuum Title: Desired EGR vs. RPM vs. Vacuum Location: 470C Usage: EGR Enable Tables Tips: Digital Valve = All 99.6 %, Linear Valve = Desired Pintle Position, EVRV = Duty Cycle Conversion: % = X / 2.56 Vacuum 9 1000.000000 4 0 0 RPM 9 1000.000000 4 0 0 % 1 0.000000 255.000000 1 Desired EGR Gain Factor vs. Temperature Title: Desired EGR Gain Factor vs. Temperature Location: 475E Usage: EGR Enable Tables Tips: Conversion: Factor = X / 128 Factor 1 1000.000000 0 0 C 7 1000.000000 4 0 0 Factor 1 0.000000 255.000000 1 EGR Gain Factor vs. Baro vs. MAP Title: EGR Gain Factor vs. Baro vs. MAP Location: 4768 Usage: EGR Enable Tables Tips: Conversion: Factor = X / 128 Baro 4 1000.000000 4 0 0 MAP 8 1000.000000 4 0 0 Factor 1 0.000000 255.000000 1 EGR Fuel Reduction vs. RPM vs. Vacuum Title: EGR Fuel Reduction vs. RPM vs. Vacuum Location: 478B Usage: EGR Enable Tables Tips: Used for % EGR with backpressure valves, if L400D, Bit 2 "Backpressure EGR" is enabled. Used for EGR fuel reduction if other types of EGR valves are used and L400D, Bit 2 is not enabled. 25% fuel reduction maximum. Conversion: % = 0.097660 * X Vacuum 13 1000.000000 4 0 0 RPM 5 1000.000000 4 0 0 % 1 0.000000 255.000000 1 EGR Filter Coefficient vs. Airflow Title: EGR Filter Coefficient vs. Airflow Location: 47CC Usage: EGR Enable Tables Tips: Conversion: Coefficient = X / 256 Coefficient 1 1000.000000 0 0 Airflow 5 1000.000000 4 0 0 Coefficient 3 0.000000 255.000000 1 EGR Exhaust Backpressure vs. Airflow Title: EGR Exhaust Backpressure vs. Airflow Location: 47D1 Usage: EGR Enable Tables Tips: Conversion: Backpressure = .3125 * X Backpressure 1 1000.000000 0 0 Airflow 17 1000.000000 4 0 0 Backpressure 1 0.000000 255.000000 1 EGR % Flow vs. Delta MAP vs. EGR %, (or EVRV Duty Cycle) Title: EGR % Flow vs. Delta MAP vs. EGR %, (or EVRV Duty Cycle) Location: 47E6 Usage: EGR Enable Tables Tips: Conversion: EGR % Flow = X / 2.56 MAP 10 1000.000000 4 0 0 EGR % Flow 11 1000.000000 4 0 0 EGR % Flow 1 0.000000 255.000000 1 EGR % Altitude Correction Multiplier vs. Baro Title: EGR % Altitude Correction Multiplier vs. Baro Location: 4854 Usage: EGR Enable Tables Tips: Conversion: Multiplier = X / 256 Multiplier 1 1000.000000 0 0 Baro 4 1000.000000 4 0 0 Multiplier 3 0.000000 255.000000 1 EGR Spark Correction vs. RPM vs. Vacuum Title: EGR Spark Correction vs. RPM vs. Vacuum Location: 4861 Usage: EGR Enable Tables Tips: Adjusts spark advance for EGR operating conditions. This value is added to the value in the "Main Spark Tables". This table automatically adjusts for L413E "EGR Spark Bias". Conversion: Spark Table - Bias = 0.351563 * (X - Y) Vacuum 13 1000.000000 4 0 0 RPM 5 1000.000000 4 0 0 deg 1 0.000000 255.000000 1 EGR D. C. Integral Initial vs. Desired EGR Position Title: EGR D. C. Integral Initial vs. Desired EGR Position Location: 48A8 Usage: EGR Enable Tables Tips: Digital EGR pintle position control calibration. Conversion: Initial Value = X / 2.56 Initial Value 1 1000.000000 0 0 % EGR 5 1000.000000 4 0 0 Initial Value 1 0.000000 255.000000 1 EGR Integral Gain vs. EGR Error Title: EGR Integral Gain vs. EGR Error Location: 48AE Usage: EGR Enable Tables Tips: Digital EGR pintle position control calibration. Conversion: Gain = X / 256 Gain 1 1000.000000 0 0 EGR % Error 5 1000.000000 4 0 0 Gain 3 0.000000 255.000000 1 EGR Proportional Gain vs. EGR Error Title: EGR Proportional Gain vs. EGR Error Location: 48B4 Usage: EGR Enable Tables Tips: Digital EGR pintle position control calibration. Conversion: Gain = X / 256 Gain 1 1000.000000 0 0 % EGR Error 5 1000.000000 4 0 0 Gain 3 0.000000 255.000000 1 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 ==== BLM Parameters ============================ BLM Parameters 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 RPM Boundaries for BLM Cells Title: RPM Boundaries for BLM Cells Location: 48EC Usage: BLM Parameters Tips: Conversion: RPM = 25.000000 * X RPM 1 1000.000000 0 0 3 1000.000000 4 0 0 RPM 0 0.000000 255.000000 1 MAP Boundaries for BLM Cells Title: MAP Boundaries for BLM Cells Location: 48EF Usage: BLM Parameters Tips: Conversion: MAP (Kpa) = 0.369000 * X + 10.35 Kpa 1 1000.000000 0 0 3 1000.000000 4 0 0 Kpa 1 0.000000 255.000000 1 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 ==== O2 Window Boundaries ======================= O2 Window Boundaries 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 Closed Loop O2 Window Title: Closed Loop O2 Window Location: 48FD Usage: O2 Window Boundaries Tips: Used to make sure O2 doesn't dwell around stoic, indicating a fault with the O2 sensor. If O2 dwells, learn is disabled after period of time. Conversion: O2 mVDC = 4.340280 * X mVDC 1 1000.000000 0 0 2 1000.000000 4 0 0 mVDC 0 0.000000 255.000000 1 Open Loop O2 Window Title: Open Loop O2 Window Location: 48FF Usage: O2 Window Boundaries Tips: Used to make sure O2 doesn't dwell around stoic, indicating a fault with the O2 sensor. If O2 dwells, learn is disabled after period of time. Conversion: O2 mVDC = 4.340280 * X mVDC 1 1000.000000 0 0 2 1000.000000 4 0 0 mVDC 0 0.000000 255.000000 1 Closed Loop Idle O2 Window Title: Closed Loop Idle O2 Window Location: 4901 Usage: O2 Window Boundaries Tips: Used to make sure O2 doesn't dwell around stoic, indicating a fault with the O2 sensor. If O2 dwells, learn is disabled after period of time. Conversion: O2 mVDC = 4.340280 * X mVDC 1 1000.000000 0 0 2 1000.000000 4 0 0 mVDC 0 0.000000 255.000000 1 Open Loop Idle O2 Window Title: Open Loop Idle O2 Window Location: 4903 Usage: O2 Window Boundaries Tips: Used to make sure O2 doesn't dwell around stoic, indicating a fault with the O2 sensor. If O2 dwells, learn is disabled after period of time. Conversion: O2 mVDC = 4.340280 * X mVDC 1 1000.000000 0 0 2 1000.000000 4 0 0 mVDC 0 0.000000 255.000000 1 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 ==== BPW Parameters =========================== BPW Parameters 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 RPM for PE vs. Baro kpa Title: RPM for PE vs. Baro kpa Location: 4973 Usage: BPW Parameters Tips: Conversion: RPM = 25.000000 * X RPM 1 1000.000000 0 0 kpa 4 1000.000000 4 0 0 RPM 0 0.000000 255.000000 1 Async Short BPW Offset vs. BPW Title: Async Short BPW Offset vs. BPW Location: 4977 Usage: BPW Parameters Tips: CPI/PFI only. Values are added to L496F "Async Short BPW Offset Bias". Table selected by flag L400E bit 4 "Use Async Short BPW Offset vs. BPW Table". This xdf does not automatically correct for L496F "Async Short BPW Offset Bias". Conversion: uSec. = 15.2587890 * X uSec. 1 1000.000000 0 0 uSec. BPW 15 1000.000000 4 0 0 uSec. 1 0.000000 255.000000 1 BPW Multiplier vs. Fuel Pump Voltage Title: BPW Multiplier vs. Fuel Pump Voltage Location: 4986 Usage: BPW Parameters Tips: Adjusts for variations in voltage to fuel pump. Conversion: Multiplier = X / 128 Multiplier 1 1000.000000 0 0 volts 17 1000.000000 4 0 0 Multiplier 3 0.000000 255.000000 1 CAT Overheat AFR Limit vs. Airflow Title: CAT Overheat AFR Limit vs. Airflow Location: 4997 Usage: BPW Parameters Tips: Conversion: AFR = 0.100 * X AFR 1 1000.000000 0 0 Airflow 17 1000.000000 4 0 0 AFR 1 0.000000 255.000000 1 BPW Altitude Correction Multiplier vs. MAP vs. Baro Title: BPW Altitude Correction Multiplier vs. MAP vs. Baro Location: 49AB Usage: BPW Parameters Tips: Conversion: Multiplier = X / 128 Baro 4 1000.000000 4 0 0 kpa 9 1000.000000 4 0 0 Multiplier 3 0.000000 255.000000 1 Altitude Compensation Value for MAP Title: Altitude Compensation Value for MAP Location: 49CF Usage: BPW Parameters Tips: ?????? Conversion: Kpa = .625 * X + 5 Value 1 1000.000000 0 0 Baro 4 1000.000000 4 0 0 Value 0 0.000000 255.000000 1 Open Throttle VE vs. MAP vs. RPM Title: Open Throttle VE vs. MAP vs. RPM Location: 49D6 Usage: BPW Parameters Tips: Table used if TPS equal to or greater than L48D8 "Maximum TPS for Idle VE", or MPH equal to or greater than L48D6 "Maximum MPH for Idle VE", or RPM equal to or greater than 1800 RPM. Conversion: VE = 0.390625 * X kpa 11 1000.000000 4 0 0 RPM 16 1000.000000 4 0 0 VE 1 0.000000 255.000000 1 Idle VE vs. MAP vs. RPM Title: Idle VE vs. MAP vs. RPM Location: 4A89 Usage: BPW Parameters Tips: Table used if TPS less than L48D8 "Maximum TPS for Idle VE", or MPH less than L48D6 "Maximum MPH for Idle VE", or RPM less than 1800 RPM. Conversion: VE = 0.390625 * X kpa 11 1000.000000 4 0 0 RPM 8 1000.000000 4 0 0 VE 1 0.000000 255.000000 1 MAT & CTS Blend Multiplier vs. Airflow Title: MAT & CTS Blend Multiplier vs. Airflow Location: 4AE1 Usage: BPW Parameters Tips: Larger multiplier = more CTS blended into MAT. Used only if L400B Bit 6 "MAT Sensor" is enabled. Conversion: Multiplier = X / 128 Multiplier 1 1000.000000 0 0 Airflow 17 1000.000000 4 0 0 Multiplier 3 0.000000 255.000000 1 Inverse Air Density @ Sea Level vs. Blended Intake Temperature Title: Inverse Air Density @ Sea Level vs. Blended Intake Temperature Location: 4AF2 Usage: BPW Parameters Tips: Conversion: l/g = (X * 128 + 29824) / 45064 l/g 1 1000.000000 0 0 C 17 1000.000000 4 0 0 l/g 2 0.000000 255.000000 1 Injector Offset vs. Battery Voltage Title: Injector Offset vs. Battery Voltage Location: 4B03 Usage: BPW Parameters Tips: Settings will vary upon type of injectors used and amount of fuel pressure used. It's very important that this table be correct, sometimes the correct settings can be got from the injector manufacture, if not the injectors should be tested. Conversion: uSec. = 15.2587890 * X uSec. 1 1000.000000 0 0 volts 17 1000.000000 4 0 0 uSec. 0 0.000000 255.000000 1 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 ==== Deceleration Enleanment Parameters =============== Deceleration Enleanment Parameters 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 Deceleration Enleanment Factor vs. Temperature Title: Deceleration Enleanment Factor vs. Temperature Location: 4B15 Usage: Deceleration Enleanment Parameters Tips: Conversion: Factor = X / 32 Factor 1 1000.000000 0 0 C 9 1000.000000 4 0 0 Factor 1 0.000000 255.000000 1 Deceleration Enleanment vs. MAP Difference Title: Deceleration Enleanment vs. MAP Difference Location: 4B1E Usage: Deceleration Enleanment Parameters Tips: Set amount of fuel reduction based upon the amount of change in MAP kpa. Conversion: % = 0.390625 * X % 1 1000.000000 0 0 kpa 11 1000.000000 4 0 0 % 1 0.000000 255.000000 1 Deceleration Enleanment vs. TPS Difference Title: Deceleration Enleanment vs. TPS Difference Location: 4B29 Usage: Deceleration Enleanment Parameters Tips: Set amount of fuel reduction based upon the amount of change in TPS position. Conversion: % = 0.390625 * X % 1 1000.000000 0 0 % TPS 17 1000.000000 4 0 0 % 1 0.000000 255.000000 1 MAP Filter Coefficient vs. Temperature Title: MAP Filter Coefficient vs. Temperature Location: 4B3A Usage: Deceleration Enleanment Parameters Tips: Conversion: X / 256 Coefficient 1 1000.000000 0 0 C 13 1000.000000 4 0 0 Coefficient 3 0.000000 255.000000 1 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 ==== Acceleration Enrichment Tables =================== Acceleration Enrichment Tables 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 AE vs. MAP Difference Title: AE vs. MAP Difference Location: 4B48 Usage: Acceleration Enrichment Tables Tips: Added AE based upon difference in MAP kpa. TPS AE comes in when you stab the throttle but is over after about .1 sec, then MAP AE takes over for approximately 2.5 sec. All AE BPW is done in Asynchronous mode because it is in addition to the synchronous pulses that normally fuel the engine. Conversion: uSec. = 61.03515625 * X uSec. 1 1000.000000 0 0 kpa 5 1000.000000 4 0 0 uSec. 0 0.000000 255.000000 1 AE vs. TPS Difference Title: AE vs. TPS Difference Location: 4B4D Usage: Acceleration Enrichment Tables Tips: Added AE based upon difference in TPS position. TPS AE comes in when you stab the throttle but is over after about .1 sec, then MAP AE takes over for approximately 2.5 sec. All AE BPW is done in Asynchronous mode because it is in addition to the synchronous pulses that normally fuel the engine. Conversion: uSec. = 61.03515625 * X uSec. 1 1000.000000 0 0 % 17 1000.000000 4 0 0 uSec. 0 0.000000 255.000000 1 TPS Difference AE Multiplier vs. Baro Title: TPS Difference AE Multiplier vs. Baro Location: 4B5E Usage: Acceleration Enrichment Tables Tips: Used to make large corrections to TPS AE. Conversion: Multiplier = X / 128 Multiplier 1 1000.000000 0 0 kpa 4 1000.000000 4 0 0 Multiplier 2 0.000000 255.000000 1 TPS Difference AE Coefficient vs. Temperature Title: TPS Difference AE Coefficient vs. Temperature Location: 4B62 Usage: Acceleration Enrichment Tables Tips: Used to correct TPS AE in relation to temperature, independent of L4B6F "AE Correction Factor vs. Temperature". Conversion: Coefficient = X / 256 Coefficient 1 1000.000000 0 0 C 13 1000.000000 4 0 0 Coefficient 3 0.000000 255.000000 1 AE Correction Factor vs. Temperature Title: AE Correction Factor vs. Temperature Location: 4B6F Usage: Acceleration Enrichment Tables Tips: Corrects Total AE in relation to temperature. Conversion: Factor = X / 32 Factor 1 1000.000000 0 0 C 17 1000.000000 4 0 0 Factor 1 0.000000 255.000000 1 TPS Difference AE Correction Factor vs. MAT Title: TPS Difference AE Correction Factor vs. MAT Location: 4B80 Usage: Acceleration Enrichment Tables Tips: Conversion: Factor = X / 128 Factor 1 1000.000000 0 0 C 17 1000.000000 4 0 0 Factor 1 0.000000 255.000000 1 MAP Difference AE Correction Factor vs. Temperature Title: MAP Difference AE Correction Factor vs. Temperature Location: 4B91 Usage: Acceleration Enrichment Tables Tips: Used to make corrections to TPS AE in relation to MAT/ IAT sensor data. Conversion: Factor = X / 32 Factor 1 1000.000000 0 0 C 17 1000.000000 4 0 0 Factor 1 0.000000 255.000000 1 MAP Difference AE Multiplier vs. RPM Title: MAP Difference AE Multiplier vs. RPM Location: 4BA3 Usage: Acceleration Enrichment Tables Tips: Used to make large corrections to MAP AE. TPS AE comes in when you stab the throttle but is over after about .1 sec, then MAP AE takes over for approximately 2.5 sec. All AE BPW is done in Asynchronous mode because it is in addition to the synchronous pulses that normally fuel the engine. Conversion: Multiplier = X / 128 Multiplier 1 1000.000000 0 0 RPM 8 1000.000000 4 0 0 Multiplier 3 0.000000 255.000000 1 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 ==== Open Loop AFR Tables ======================== Open Loop AFR Tables 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 Open Loop Idle Lean Limit vs. Temperature Title: Open Loop Idle Lean Limit vs. Temperature Location: 4BAB Usage: Open Loop AFR Tables Tips: Conversion: AFR = 0.100 * X AFR 1 1000.000000 0 0 C 13 1000.000000 4 0 0 AFR 1 0.000000 255.000000 1 Open Loop AFR vs. Temperature vs. Vacuum Title: Open Loop AFR vs. Temperature vs. Vacuum Location: 4BBC Usage: Open Loop AFR Tables Tips: Normally used for open loop but can be used in closed loop if L400D Bit 0 "Open Loop AFR Enabled" is enabled and temperature is greater than L48CE "Minimum Temperature for Closed Loop" and temperature is less than L48CF "Maximum Temperature for AFR Lookup in Closed Loop". Conversion: AFR = 0.100 * X Vacuum 9 1000.000000 4 0 0 C 13 1000.000000 4 0 0 AFR 1 0.000000 255.000000 1 Choke AFR vs. Temperature Title: Choke AFR vs. Temperature Location: 4C31 Usage: Open Loop AFR Tables Tips: After startup AFR increases with time, simulation a choke and choke pull off. Time between increments is from L4C42 "Choke AFR Decay Time vs. Temperature" X L4C53 "Choke AFR Decay Time Multiplier vs. Airflow". AFR is subtracted out to enrich the initial AFR after startup. Conversion: AFR = 0.100 * X AFR 1 1000.000000 0 0 C 17 1000.000000 4 0 0 AFR 1 0.000000 255.000000 1 Choke AFR Decay Time vs. Temperature Title: Choke AFR Decay Time vs. Temperature Location: 4C42 Usage: Open Loop AFR Tables Tips: After startup AFR increases with time, simulation a choke and choke pull off. Time between increments is from L4C42 "Choke AFR Decay Time vs. Temperature" X L4C53 "Choke AFR Decay Time Multiplier vs. Airflow". AFR is subtracted out to enrich the initial AFR after startup. Conversion: Sec. = 0.2 * X Sec. 1 1000.000000 0 0 C 17 1000.000000 4 0 0 Sec. 1 0.000000 255.000000 1 Choke AFR Decay Time Multiplier vs. Airflow Title: Choke AFR Decay Time Multiplier vs. Airflow Location: 4C53 Usage: Open Loop AFR Tables Tips: After startup AFR increases with time, simulation a choke and choke pull off. Time between increments is from L4C42 "Choke AFR Decay Time vs. Temperature" X L4C53 "Choke AFR Decay Time Multiplier vs. Airflow". AFR is subtracted out to enrich the initial AFR after startup. Conversion: Multiplier = X / 128 Multiplier 1 1000.000000 0 0 Airflow 5 1000.000000 4 0 0 Multiplier 2 0.000000 255.000000 1 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 ==== Power Enrichment Tables ====================== Power Enrichment Tables 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 TPS for Fast PE vs. RPM Title: TPS for Fast PE vs. RPM Location: 4C59 Usage: Power Enrichment Tables Tips: Fast PE = Entering PE with no delay time. Conversion: % TPS = 0.390625 * X % TPS 1 1000.000000 0 0 RPM 9 1000.000000 4 0 0 % TPS 1 0.000000 255.000000 1 TPS for PE vs. RPM Title: TPS for PE vs. RPM Location: 4C63 Usage: Power Enrichment Tables Tips: Conversion: % TPS = 0.390625 * X % TPS 1 1000.000000 0 0 RPM 9 1000.000000 4 0 0 % TPS 1 0.000000 255.000000 1 PE AFR vs. RPM Title: PE AFR vs. RPM Location: 4C6C Usage: Power Enrichment Tables Tips: PE is enable if TPS is equal to or greater than setting. Conversion: AFR = 0.100 * X AFR 1 1000.000000 0 0 RPM 17 1000.000000 4 0 0 AFR 1 0.000000 255.000000 1 Fast PE Entry Delay Reduction vs. RPM Title: Fast PE Entry Delay Reduction vs. RPM Location: 4C7E Usage: Power Enrichment Tables Tips: Table represents fraction of time needed to enter PE relative to the time normally needed. A value of 10 would be 1/10 the time needed to normally enter PE, when these values are used instead to compute the delay for PE. Value at L4917 " PE Delay Time" determines time to enter/exit PE. Conversion: Factor = 1 * X Factor 1 1000.000000 0 0 RPM 9 1000.000000 4 0 0 Factor 0 0.000000 255.000000 1 PE TPS Difference vs. Baro Title: PE TPS Difference vs. Baro Location: 4C87 Usage: Power Enrichment Tables Tips: Factor is delta TPS needed to bypass PE delay. Conversion: % TPS = 0.390625 * X % TPS 1 1000.000000 0 0 Baro 4 1000.000000 4 0 0 % TPS 1 0.000000 255.000000 1 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 ==== Deceleration Fuel Cut-Off Parameters =============== Deceleration Fuel Cut-Off Parameters 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 Minimum DFCO RPM vs. Temperature Title: Minimum DFCO RPM vs. Temperature Location: 4C8B Usage: Deceleration Fuel Cut-Off Parameters Tips: RPM must be greater than settings to stay in DFCO. Conversion: RPM = 25.000000 * X RPM 1 1000.000000 0 0 C 7 1000.000000 4 0 0 RPM 0 0.000000 255.000000 1 TPS for DFCO vs. RPM Title: TPS for DFCO vs. RPM Location: 4C93 Usage: Deceleration Fuel Cut-Off Parameters Tips: Conversion: % TPS = 0.390625 * X % TPS 1 1000.000000 0 0 RPM 8 1000.000000 4 0 0 % TPS 1 0.000000 255.000000 1 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 ==== Crank to Run Transition Parameters ================ Crank to Run Transition Parameters 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 Crank to Run AFR vs. Temperature Title: Crank to Run AFR vs. Temperature Location: 4C9B Usage: Crank to Run Transition Parameters Tips: Added or subtracted depending on temperature threshold in L495F "Temperature for Transition AFR Added". Conversion: AFR = 0.100 * X AFR 1 1000.000000 0 0 C 17 1000.000000 4 0 0 AFR 1 0.000000 255.000000 1 Crank to Run AFR Decay Rate vs. Temperature Title: Crank to Run AFR Decay Rate vs. Temperature Location: 4CAC Usage: Crank to Run Transition Parameters Tips: Conversion: AFR = 0.100 * X AFR 1 1000.000000 0 0 C 17 1000.000000 4 0 0 AFR 1 0.000000 255.000000 1 Crank to Run AFR Decay DRP vs. Temperature Title: Crank to Run AFR Decay DRP vs. Temperature Location: 4CBD Usage: Crank to Run Transition Parameters Tips: Elapsed DRP. Conversion: DRP = 1 * X DRP 1 1000.000000 0 0 C 17 1000.000000 4 0 0 DRP 0 0.000000 255.000000 1 Crank to Run AFR Decay Delay Multiplier vs. DRP Title: Crank to Run AFR Decay Delay Multiplier vs. DRP Location: 4CCE Usage: Crank to Run Transition Parameters Tips: Accumulated DRP prior to run. Conversion: Multiplier = X / 256 Multiplier 1 1000.000000 0 0 DRP 17 1000.000000 4 0 0 Multiplier 3 0.000000 255.000000 1 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 ==== Fuel Trim Parameters ========================= Fuel Trim Parameters 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 Integrator Delay vs. Airflow Title: Integrator Delay vs. Airflow Location: 4CDF Usage: Fuel Trim Parameters Tips: Conversion: msec. = 25 * X msec. 1 1000.000000 0 0 Airflow 9 1000.000000 4 0 0 msec. 0 0.000000 255.000000 1 Mean Rich/Lean O2 Voltage Threshold vs Airflow Title: Mean Rich/Lean O2 Voltage Threshold vs Airflow Location: 4CE8 Usage: Fuel Trim Parameters Tips: This table is replaced by fixed value at L494A "Mean Rich/ Lean Idle O2 Voltage Threshold" when at idle. Conversion: O2 mVDC = 4.340280 * X mVDC 1 1000.000000 0 0 Airflow 9 1000.000000 4 0 0 mVDC 0 0.000000 255.000000 1 Rich O2 Voltage Threshold vs Airflow Title: Rich O2 Voltage Threshold vs Airflow Location: 4CF1 Usage: Fuel Trim Parameters Tips: This table is replaced by fixed value at L4948 "Rich Idle O2 Voltage Threshold" when at idle. Conversion: O2 mVDC = 4.340280 * X mVDC 1 1000.000000 0 0 Airflow 9 1000.000000 4 0 0 mVDC 0 0.000000 255.000000 1 Lean O2 Voltage Threshold vs Airflow Title: Lean O2 Voltage Threshold vs Airflow Location: 4CFA Usage: Fuel Trim Parameters Tips: This table is replaced by fixed value at L4949 "Lean Idle O2 Voltage Threshold" when at idle. Conversion: O2 mVDC = 4.340280 * X mVDC 1 1000.000000 0 0 Airflow 9 1000.000000 4 0 0 mVDC 0 0.000000 255.000000 1 Slow O2 Filter Coefficient vs. Airflow Title: Slow O2 Filter Coefficient vs. Airflow Location: 4D03 Usage: Fuel Trim Parameters Tips: If Idle use constant at L48BB "Slow O2 Filter Coefficient for Idle". Conversion: Coefficient = X / 256 Coefficient 1 1000.000000 0 0 Airflow 9 1000.000000 4 0 0 Coefficient 3 0.000000 255.000000 1 Proportional Counts vs. Slow O2 Error Title: Proportional Counts vs. Slow O2 Error Location: 4D0C Usage: Fuel Trim Parameters Tips: Select number of counts to correct fuel delivery. Conversion: Counts = 1 * X Counts 1 1000.000000 0 0 O2 Error Counts 13 1000.000000 4 0 0 Counts 0 0.000000 255.000000 1 Proportional Duration vs. Slow O2 Error Title: Proportional Duration vs. Slow O2 Error Location:4D19 Usage: Fuel Trim Parameters Tips: Conversion: msec. = 25 * X msec. 1 1000.000000 0 0 O2 Counts 13 1000.000000 4 0 0 msec. 0 0.000000 255.000000 1 Proportional Duration Offset vs. Airflow Title: Proportional Duration Offset vs. Airflow Location: 4D26 Usage: Fuel Trim Parameters Tips: Added to L4D19 "Proportional Duration vs. Slow O2 Error". See L494B "Proportional Duration Offset at Idle" for offset at idle. Conversion: msec. = 25 * X msec. 1 1000.000000 0 0 Airflow 9 1000.000000 4 0 0 msec. 0 0.000000 255.000000 1 Proportional Flow Gain Factor vs. MAP vs. RPM Title: Proportional Flow Gain Factor vs. MAP vs. RPM Location: 4D32 Usage: Fuel Trim Parameters Tips: Conversion: Factor = X / 128 kpa 9 1000.000000 4 0 0 RPM 9 1000.000000 4 0 0 Factor 3 0.000000 255.000000 1 Integrator Delay Multiplier vs. O2 Error Title: Integrator Delay Multiplier vs. O2 Error Location: 4D83 Usage: Fuel Trim Parameters Tips: Conversion: Multiplier = X / 256 Multiplier 1 1000.000000 0 0 O2 Error 13 1000.000000 4 0 0 Multiplier 3 0.000000 255.000000 1 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 ==== Cranking Fuel Parameters ====================== Cranking Fuel Parameters 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 Crank BPW vs. Temperature Title: Crank BPW vs. Temperature Location: 4D9A Usage: Cranking Fuel Parameters Tips: This table automatically adjusts for L4D98 "Crank BPW vs. Temperature Table Scalar". Conversion: BPW = (X/256) * Y ("Y" must be linked to "Output" at L4D98.) BPW 1 1000.000000 0 0 C 17 1000.000000 4 0 0 BPW 1 0.000000 255.000000 1 Crank Fuel Multiplier vs. RPM Title: Crank Fuel Multiplier vs. RPM Location: 4DAB Usage: Cranking Fuel Parameters Tips: Value at L4D93 "Minimum DRP for L4DAB Table" must be met before this table is used. Conversion: Multiplier = X / 256 Multiplier 1 1000.000000 0 0 RPM 9 1000.000000 4 0 0 Multiplier 3 0.000000 255.000000 1 Hot Restart Crank Fuel Multiplier vs. RPM Title: Hot Restart Crank Fuel Multiplier vs. RPM Location: 4DB4 Usage: Cranking Fuel Parameters Tips: Conversion: Multiplier = X / 256 Multiplier 1 1000.000000 0 0 RPM 9 1000.000000 4 0 0 Multiplier 3 0.000000 255.000000 1 Crank Fuel Multiplier vs. Baro Title: Crank Fuel Multiplier vs. Baro Location: 4DBD Usage: Cranking Fuel Parameters Tips: Conversion: Multiplier = X / 128 Multiplier 1 1000.000000 0 0 Baro 4 1000.000000 4 0 0 Multiplier 3 0.000000 255.000000 1 Crank Fuel Multiplier vs. TPS Title: Crank Fuel Multiplier vs. TPS Location: 4DC2 Usage: Cranking Fuel Parameters Tips: Conversion: Multiplier = X / 64 Multiplier 1 1000.000000 0 0 % TPS 9 1000.000000 4 0 0 Multiplier 2 0.000000 255.000000 1 Crank Fuel Delay vs. Temperature Title: Crank Fuel Delay vs. Temperature Location: 4DCB Usage: Cranking Fuel Parameters Tips: Delays cranking fuel for number of DRP. Conversion: DRP = 1 * X DRP 1 1000.000000 0 0 C 17 1000.000000 4 0 0 DRP 0 0.000000 255.000000 1 Cold Crank BPW Multiplier vs. DRP Title: Cold Crank BPW Multiplier vs. DRP Location: 4DDC Usage: Cranking Fuel Parameters Tips: Used if temperature less than L4D97 "Temperature for Cold Cranking". Conversion: Multiplier = X / 128 Multiplier 1 1000.000000 0 0 DRP 24 1000.000000 4 0 0 Multiplier 4 0.000000 255.000000 1 Non Hot Restart Crank BPW Multiplier vs. DRP Title: Non Hot Restart Crank BPW Multiplier vs. DRP Location: 4DF4 Usage: Cranking Fuel Parameters Tips: Used if temperature equal to or greater than L4D97 "Temperature for Cold Cranking" and not in "Hot Restart" mode. Conversion: Multiplier = X / 128 Multiplier 1 1000.000000 0 0 DRP 24 1000.000000 4 0 0 Multiplier 3 0.000000 255.000000 1 Hot Restart Crank BPW Multiplier vs. DRP Title: Hot Restart Crank BPW Multiplier vs. DRP Location: 4E0C Usage: Cranking Fuel Parameters Tips: Conversion: Multiplier = X / 128 Multiplier 1 1000.000000 0 0 DRP 24 1000.000000 4 0 0 Multiplier 3 0.000000 255.000000 1 Cycling Crank BPW Multiplier vs. DRP Title: Cycling Crank BPW Multiplier vs. DRP Location: 4E24 Usage: Cranking Fuel Parameters Tips: Cycling table for DRP greater than 24. Conversion: Multiplier = X / 128 Multiplier 1 1000.000000 0 0 DRP 8 1000.000000 4 0 0 Multiplier 3 0.000000 255.000000 1 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 ==== IAC Tables =============================== IAC Tables 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 IAC Counts vs. Desired Airflow Title: IAC Counts vs. Desired Airflow Location: 4E90 Usage: IAC Tables Tips: Conversion: Counts = 1 * X Counts 1 1000.000000 0 0 Airflow 17 1000.000000 4 0 0 Counts 0 0.000000 255.000000 1 IAC Baro Compensation Factor vs. Baro Title: IAC Baro Compensation Factor vs. Baro Location: 4EA4 Usage: IAC Tables Tips: Conversion: Factor = X / 128 Factor 1 1000.000000 0 0 kpa 10 1000.000000 4 0 0 Factor 1 0.000000 255.000000 1 IAC % Flow vs. Temperature (P/N) Title: IAC % Flow vs. Temperature (P/N) Location: 4EC0 Usage: IAC Tables Tips: Conversion: % = 0.390625 * X % Airflow 1 1000.000000 0 0 C 13 1000.000000 4 0 0 % Airflow 1 0.000000 255.000000 1 IAC % Flow vs. Temperature (Drive) Title: IAC % Flow vs. Temperature (Drive) Location: 4ECD Usage: IAC Tables Tips: Conversion: % = 0.390625 * X % Airflow 1 1000.000000 0 0 C 13 1000.000000 4 0 0 % Airflow 1 0.000000 255.000000 1 IAC Cold Offset Delay vs. Temperature Title: IAC Cold Offset Delay vs. Temperature Location: 4EDA Usage: IAC Tables Tips: Delay until initial IAC flow is decayed out after startup. Conversion: Sec. = X / 10 Sec. 1 1000.000000 0 0 C 13 1000.000000 4 0 0 Sec. 1 0.000000 255.000000 1 Decay Delay Multiplier vs. Airflow Title: Decay Delay Multiplier vs. Airflow Location: 4EE7 Usage: IAC Tables Tips: Used for table L4EDA "IAC Cold Offset Delay vs. Temperature". Conversion: Multiplier = X / 128 Multiplier 1 1000.000000 0 0 gms/sec. 5 1000.000000 4 0 0 Multiplier 2 0.000000 255.000000 1 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 ==== Closed Loop Idle Qualifiers ===================== Closed Loop Idle Qualifiers 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 Closed Loop Idle Enable Delay vs. Temperature (High RPM) Title: Closed Loop Idle Enable Delay vs. Temperature (High RPM) Location: 4EF3 Usage: Closed Loop Idle Qualifiers Tips: IAC closed loop idle enable delay after start up vs. cool temp (high RPM). Conversion: Sec. = X / 10 Sec. 1 1000.000000 0 0 C 13 1000.000000 4 0 0 Sec. 1 0.000000 255.000000 1 Closed Loop Idle Enable Delay vs. Temperature (Low RPM) Title: Closed Loop Idle Enable Delay vs. Temperature (Low RPM) Location: 4F00 Usage: Closed Loop Idle Qualifiers Tips: IAC closed loop idle enable delay after start up vs. cool temp (low RPM). Conversion: Sec. = X / 10 Sec. 1 1000.000000 0 0 C 13 1000.000000 4 0 0 Sec. 1 0.000000 255.000000 1 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 ==== IAC Transition Parameters ===================== IAC Transition Parameters 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 IAC Flow Difference for A/C Transition vs. MAT Title: IAC Flow Difference for A/C Transition vs. MAT Location: 4F15 Usage: IAC Transition Parameters Tips: Enabled with L4E8D Bit 6 "MAT Table for A/C Transitions". Conversion: % = X / 2.56 % Airflow 1 1000.000000 0 0 C 5 1000.000000 4 0 0 % Airflow 1 0.000000 255.000000 1 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 ==== Idle Speed Tables =========================== Idle Speed Tables 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 Idle Speed vs. Temperature (P/N, A/C Off) Title: Idle Speed vs. Temperature (P/N, A/C Off) Location: 4F30 Usage: Idle Speed Tables Tips: In P/N and A/C is off. Conversion: RPM = 12.500000 * X RPM 1 1000.000000 0 0 C 15 1000.000000 4 0 0 RPM 0 0.000000 255.000000 1 Idle Speed vs. Temperature (P/N, A/C On) Title: Idle Speed vs. Temperature (P/N, A/C On) Location: 4F3F Usage: Idle Speed Tables Tips: In P/N and A/C is on. Conversion: RPM = 12.500000 * X RPM 1 1000.000000 0 0 C 15 1000.000000 4 0 0 RPM 0 0.000000 255.000000 1 Idle Speed vs. Temperature (Drive, A/C Off) Title: Idle Speed vs. Temperature (Drive, A/C Off) Location: 4F4E Usage: Idle Speed Tables Tips: In drive and A/C is off. Conversion: RPM = 12.500000 * X RPM 1 1000.000000 0 0 C 15 1000.000000 4 0 0 RPM 0 0.000000 255.000000 1 Idle Speed vs. Temperature (Drive, A/C On) Title: Idle Speed vs. Temperature (Drive, A/C On) Location: 4F5D Usage: Idle Speed Tables Tips: In drive and A/C is on. Conversion: RPM = 12.500000 * X RPM 1 1000.000000 0 0 C 15 1000.000000 4 0 0 RPM 0 0.000000 255.000000 1 Added Initial Idle Speed vs. Temperature Title: Added Initial Idle Speed vs. Temperature Location: 4F6C Usage: Idle Speed Tables Tips: At startup. Conversion: RPM = 12.500000 * X RPM 1 1000.000000 0 0 C 15 1000.000000 4 0 0 RPM 1 0.000000 255.000000 1 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 ==== Integral Idle Control Tables ===================== Integral Idle Control Tables 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 Idle Integral Gain vs. RPM Error (Low RPM, P/N) Title: Idle Integral Gain vs. RPM Error (Low RPM, P/N) Location: 4F90 Usage: Integral Idle Control Tables Tips: Idle speed low and in P/N. Conversion: Gain = X * 2.05 Gain 1 1000.000000 0 0 RPM Error 11 1000.000000 4 0 0 Gain 1 0.000000 255.000000 1 Idle Integral Gain vs. RPM Error (High RPM, P/N) Title: Idle Integral Gain vs. RPM Error (High RPM, P/N) Location: 4F9B Usage: Integral Idle Control Tables Tips: Idle speed high and in P/N. Conversion: Gain = X * 2.05 Gain 1 1000.000000 0 0 RPM Error 11 1000.000000 4 0 0 Gain 1 0.000000 255.000000 1 Idle Integral Gain vs. RPM Error (Low RPM, Drive) Title: Idle Integral Gain vs. RPM Error (Low RPM, Drive) Location: 4FA6 Usage: Integral Idle Control Tables Tips: Idle speed low and in drive. Conversion: Gain = X * 2.05 Gain 1 1000.000000 0 0 RPM Error 11 1000.000000 4 0 0 Gain 1 0.000000 255.000000 1 Idle Integral Gain vs. RPM Error (High RPM, Drive) Title: Idle Integral Gain vs. RPM Error (High RPM, Drive) Location: 4FB1 Usage: Integral Idle Control Tables Tips: Idle speed high and in drive. Conversion: Gain = X * 2.05 Gain 1 1000.000000 0 0 RPM Error 11 1000.000000 4 0 0 Gain 1 0.000000 255.000000 1 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 ==== Idle Proportional Action Tables =================== Idle Proportional Action Tables 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 Idle Proportional Term vs. RPM Error (Low RPM, P/N) Title: Idle Proportional Term vs. RPM Error (Low RPM, P/N) Location: 4FCA Usage: Idle Proportional Action Tables Tips: Low idle and in P/N. Conversion: % Flow = 0.390625 * X % Flow 1 1000.000000 0 0 RPM Error 11 1000.000000 4 0 0 % Flow 1 0.000000 255.000000 1 Idle Proportional Term vs. RPM Error (High RPM, P/N) Title: Idle Proportional Term vs. RPM Error (High RPM, P/N) Location: 4FD5 Usage: Idle Proportional Action Tables Tips: High idle and in P/N. Conversion: % Flow = 0.390625 * X % Flow 1 1000.000000 0 0 RPM Error 11 1000.000000 4 0 0 % Flow 1 0.000000 255.000000 1 Idle Proportional Term vs. RPM Error (Low RPM, D, O/L Idle) Title: Idle Proportional Term vs. RPM Error (Low RPM, D, O/L Idle) Location: 4FE0 Usage: Idle Proportional Action Tables Tips: Low idle, A/C off, in drive, and open loop idle. Conversion: % Flow = 0.390625 * X % Flow 1 1000.000000 0 0 RPM Error 11 1000.000000 4 0 0 % Flow 1 0.000000 255.000000 1 Idle Proportional Term vs. RPM Error (High RPM, D, O/L Idle) Title: Idle Proportional Term vs. RPM Error (High RPM, D, O/L Idle) Location: 4FEB Usage: Idle Proportional Action Tables Tips: High idle, A/C off, in drive, and open loop idle. Conversion: % Flow = 0.390625 * X % Flow 1 1000.000000 0 0 RPM Error 11 1000.000000 4 0 0 % Flow 1 0.000000 255.000000 1 Idle Proportional Term vs. RPM Error (Low RPM, D, C/L Idle) Title: Idle Proportional Term vs. RPM Error (Low RPM, D, C/L Idle) Location: 4FF6 Usage: Idle Proportional Action Tables Tips: Low idle, A/C off, in drive, and closed loop idle. Conversion: % Flow = 0.390625 * X % Flow 1 1000.000000 0 0 RPM Error 11 1000.000000 4 0 0 % Flow 1 0.000000 255.000000 1 Idle Proportional Term vs. RPM Error (High RPM, D, C/L Idle) Title: Idle Proportional Term vs. RPM Error (High RPM, D, C/L Idle) Location: 5001 Usage: Idle Proportional Action Tables Tips: High idle, A/C off, in drive, and closed loop idle. Conversion: % Flow = 0.390625 * X % Flow 1 1000.000000 0 0 RPM Error 11 1000.000000 4 0 0 % Flow 1 0.000000 255.000000 1 Idle Proportional Term vs. RPM Error (Low RPM, A/C On, D, O/L Idle) Title: Idle Proportional Term vs. RPM Error (Low RPM, A/C On, D, O/L Idle) Location: 500C Usage: Idle Proportional Action Tables Tips: Low idle, A/C on, in drive, and open loop idle. Conversion: % Flow = 0.390625 * X % Flow 1 1000.000000 0 0 RPM Error 11 1000.000000 4 0 0 % Flow 1 0.000000 255.000000 1 Idle Proportional Term vs. RPM Error (High RPM, A/C On, D, O/L Idle) Title: Idle Proportional Term vs. RPM Error (High RPM, A/C On, D, O/L Idle) Location: 5017 Usage: Idle Proportional Action Tables Tips: High idle, A/C on, in drive, and open loop idle Conversion: % Flow = 0.390625 * X % Flow 1 1000.000000 0 0 RPM Error 11 1000.000000 4 0 0 % Flow 1 0.000000 255.000000 1 Idle Proportional Term vs. RPM Error (Low RPM, A/C On, D, C/L) Title: Idle Proportional Term vs. RPM Error (Low RPM, A/C On, D, C/L) Location: 5022 Usage: Idle Proportional Action Tables Tips: Low idle, A/C on, in drive, and closed loop. Conversion: % Flow = 0.390625 * X % Flow 1 1000.000000 0 0 RPM Error 11 1000.000000 4 0 0 % Flow 1 0.000000 255.000000 1 Idle Proportional Term vs. RPM Error (High RPM, A/C On, D, C/L) Title: Idle Proportional Term vs. RPM Error (High RPM, A/C On, D, C/L) Location: 502D Usage: Idle Proportional Action Tables Tips: High idle, A/C on, in drive, and closed loop. Conversion: % Flow = 0.390625 * X % Flow 1 1000.000000 0 0 RPM Error 11 1000.000000 4 0 0 % Flow 1 0.000000 255.000000 1 Idle Derivative Term vs. Transient RPM Ratio Title: Idle Derivative Term vs. Transient RPM Ratio Location: 503A Usage: Idle Proportional Action Tables Tips: Conversion: % Flow = (X - 128) / 4 % Flow 1 1000.000000 0 0 Transient RPM Ratio 17 1000.000000 4 0 0 % Flow 1 0.000000 255.000000 1 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 ==== Throttle Follower Parameters ==================== Throttle Follower Parameters 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 IAC Throttle Follower Gain vs. Temperature Title: IAC Throttle Follower Gain vs. Temperature Location: 5055 Usage: Throttle Follower Parameters Tips: Conversion: Gain = X / 64 Gain 1 1000.000000 0 0 C 13 1000.000000 4 0 0 Gain 2 0.000000 255.000000 1 IAC Throttle Follower Gain vs. RPM Title: IAC Throttle Follower Gain vs. RPM Location: 5063 Usage: Throttle Follower Parameters Tips: Conversion: Gain = X / 64 Gain 1 1000.000000 0 0 RPM 9 1000.000000 4 0 0 Gain 2 0.000000 255.000000 1 TPS Filtering Period vs. MPH Title: TPS Filtering Period vs. MPH Location: 506F Usage: Throttle Follower Parameters Tips: Used to filter TPS back down during throttle closing for throttle follower and other items. Conversion: Sec. = X / 40 Sec. 1 1000.000000 0 0 RPM 11 1000.000000 4 0 0 Sec. 2 0.000000 255.000000 1 TPS Filtering Coefficient vs. MPH Title: TPS Filtering Coefficient vs. MPH Location: 507A Usage: Throttle Follower Parameters Tips: Filter coefficient for filter TPS back down during throttle closing for throttle follower and other items. Conversion: Coefficient = X / 25.6 Coefficient 1 1000.000000 0 0 RPM 11 1000.000000 4 0 0 Coefficient 2 0.000000 255.000000 1 Lower Limit for TPS to Ensure Throttle Follower Title: Lower Limit for TPS to Ensure Throttle Follower Location: 5088 Usage: Throttle Follower Parameters Tips: Lower limit for TPS to ensure some added throttle follower flow during closed throttle. See L509E "Multiplier for Lower TPS Limit" for table modifier. Conversion: % TPS = X * .0977 % TPS 1 1000.000000 0 0 C 13 1000.000000 4 0 0 % TPS 1 0.000000 255.000000 1 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 ==== IAC AE, PE, DFCO Parameters =================== IAC AE, PE, DFCO Parameters 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 AE vs. % IAC Flow Difference Title: AE vs. % IAC Flow Difference Location: 50A1 Usage: IAC AE, PE, DFCO Parameters Tips: See L50A9 "Flow Bias for Added IAC Flow in DFCO". Conversion: uSec. = 15.2587890 * X uSec. 1 1000.000000 0 0 % Flow 5 1000.000000 4 0 0 uSec. 0 0.000000 255.000000 1 Additional IAC Flow vs. RPM for DFCO Title: Additional IAC Flow vs. RPM for DFCO Location: 50AC Usage: IAC AE, PE, DFCO Parameters Tips: Decayed to 0.0 % after DFCO has ended. Conversion: % = 0.390625 * X % Flow 1 1000.000000 0 0 RPM 16 1000.000000 4 0 0 % Flow 1 0.000000 255.000000 1 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 ==== Governor Parameters ======================== Governor Parameters 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 Governor Integral Gain Factor vs. Desired TPS Title: Governor Integral Gain Factor vs. Desired TPS Location: 50E7 Usage: Governor Parameters Tips: Conversion: Factor = X / 32 Factor 1 1000.000000 0 0 % TPS 5 1000.000000 4 0 0 Factor 2 0.000000 255.000000 1 Governor Derivative Action Thresholds vs. Delta RPM Title: Governor Derivative Action Thresholds vs. Delta RPM Location: 50ED Usage: Governor Parameters Tips: Conversion: RPM = 25.000000 * X RPM 1 1000.000000 0 0 Delta RPM 11 1000.000000 4 0 0 RPM 0 0.000000 255.000000 1 TPS Derivative Gain vs. Temperature Title: TPS Derivative Gain vs. Temperature Location: 50F8 Usage: Governor Parameters Tips: Conversion: Gain = X / 64 Gain 1 1000.000000 0 0 C 5 1000.000000 4 0 0 Gain 2 0.000000 255.000000 1 Governor Actuator Proportional Gain vs. TPS Error Title: Governor Actuator Proportional Gain vs. TPS Error Location: 50FE Usage: Governor Parameters Tips: Conversion: Gain = X / 64 Gain 1 1000.000000 0 0 % TPS Error 9 1000.000000 4 0 0 Gain 2 0.000000 255.000000 1 Governor Actuator Integral Gain vs. TPS Error Title: Governor Actuator Integral Gain vs. TPS Error Location: 5108 Usage: Governor Parameters Tips: Conversion: Gain = X / 64 Gain 1 1000.000000 0 0 % TPS Error 9 1000.000000 4 0 0 Gain 2 0.000000 255.000000 1 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 ==== Shift Light Parameters ======================== Shift Light Parameters 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 Upper Engine/ Trans RPM Ratio vs. Gear Title: Upper Engine/ Trans RPM Ratio vs. Gear Location: 5111 Usage: Shift Light Parameters Tips: Upper engine RPM/ transmission RPM of a pair used. Establish correct gear range for specified gear to set shift light trip point. Conversion: Ratio = X / 10 Ratio 1 1000.000000 0 0 Gear 4 1000.000000 4 0 0 Ratio 1 0.000000 255.000000 1 Minimum RPM Thresholds vs. Gear Title: Minimum RPM Thresholds vs. Gear Location: 5115 Usage: Shift Light Parameters Tips: Conversion: RPM = 25.000000 * X RPM 1 1000.000000 0 0 Gear 4 1000.000000 4 0 0 RPM 0 0.000000 255.000000 1 TPS Load Scalar vs. Gear Title: TPS Load Scalar vs. Gear Location: 5119 Usage: Shift Light Parameters Tips: 0 - 2 multiplier to adjust TPS rel.? to specific gear. Conversion: Multiplier = X / 128 Multiplier 1 1000.000000 0 0 Gear 4 1000.000000 4 0 0 Multiplier 2 0.000000 255.000000 1 TPS Load Threshold vs. RPM (Low Gears, Light On) Title: TPS Load Threshold vs. RPM (Low Gears, Light On) Location: 5123 Usage: Shift Light Parameters Tips: Used by shift light code to get a TPS threshold. Conversion: % Load = X / 2.56 % Load 1 1000.000000 0 0 RPM 11 1000.000000 4 0 0 % Load 1 0.000000 255.000000 1 TPS Load Threshold vs. RPM (Low Gears, Light Off) Title: TPS Load Threshold vs. RPM (Low Gears, Light Off) Location: 512E Usage: Shift Light Parameters Tips: Used by shift light code to get a TPS threshold. Conversion: % Load = X / 2.56 % Load 1 1000.000000 0 0 RPM 11 1000.000000 4 0 0 % Load 1 0.000000 255.000000 1 TPS Load Threshold vs. RPM (High Gears, Light On) Title: TPS Load Threshold vs. RPM (High Gears, Light On) Location: 5139 Usage: Shift Light Parameters Tips: Used by shift light code to get a TPS threshold. Conversion: % Load = X / 2.56 % Load 1 1000.000000 0 0 RPM 11 1000.000000 4 0 0 % Load 1 0.000000 255.000000 1 TPS Load Threshold vs. RPM (High Gears, Light Off) Title: TPS Load Threshold vs. RPM (High Gears, Light Off) Location: 5144 Usage: Shift Light Parameters Tips: Used by shift light code to get a TPS threshold. Conversion: % Load = X / 2.56 % Load 1 1000.000000 0 0 RPM 11 1000.000000 4 0 0 % Load 1 0.000000 255.000000 1 TPS Shift Light Threshold Correction vs. Baro Title: TPS Shift Light Threshold Correction vs. Baro Location: 514F Usage: Shift Light Parameters Tips: Baro Correction to Tables L5123, L512E, L5139, and L5144 above. Conversion: Multiplier = X / 128 Multiplier 1 1000.000000 0 0 Baro kpa 4 1000.000000 4 0 0 Multiplier 1 0.000000 255.000000 1 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 ==== 700R4 TCC Parameters ======================= 700R4 TCC Parameters 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 Lower TPS for TCC to Lock vs. MPH Title: Lower TPS for TCC to Lock vs. MPH Location: 5162 Usage: 700R4 TCC Parameters Tips: See L5159 "TPS Hysteresis". Conversion: % TPS = 0.390625 * X % TPS 1 1000.000000 0 0 MPH 9 1000.000000 4 0 0 % TPS 1 0.000000 255.000000 1 Upper TPS for TCC to Unlock vs. MPH Title: Upper TPS for TCC to Unlock vs. MPH Location: 516F Usage: 700R4 TCC Parameters Tips: Conversion: % TPS = 0.390625 * X % TPS 1 1000.000000 0 0 MPH 13 1000.000000 4 0 0 % TPS 1 0.000000 255.000000 1 Upper TPS for TCC to Lock vs. MPH Title: Upper TPS for TCC to Lock vs. MPH Location: 517C Usage: 700R4 TCC Parameters Tips: Conversion: % TPS = 0.390625 * X % TPS 1 1000.000000 0 0 MPH 13 1000.000000 4 0 0 % TPS 1 0.000000 255.000000 1 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 ==== 4L80-E Kickdown Mode Shift Thresholds ============== 4L80-E Kickdown Mode Shift Thresholds 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 Upshift MPH vs. Shift Title: Upshift MPH vs. Shift Location: 5D3E Usage: 4L80-E Kickdown Mode Shift Thresholds Tips: Both MPH and RPM Qualifiers must be met before upshift will occur. See L5D56 "Upshift RPM". Conversion: MPH = 0.5 * X MPH 1 1000.000000 0 0 Shift 3 1000.000000 4 0 0 MPH 1 0.000000 255.000000 1 Downshift MPH vs. Shift Title: Downshift MPH vs. Shift Location: 5D41 Usage: 4L80-E Kickdown Mode Shift Thresholds Tips: Both MPH and RPM Qualifiers must be met before downshift will occur. See L5D56 "Upshift RPM". Conversion: MPH = 0.5 * X MPH 1 1000.000000 0 0 Shift 3 1000.000000 4 0 0 MPH 1 0.000000 255.000000 1 Upshift MPH for Hot Engine Mode vs. Shift Title: Upshift MPH for Hot Engine Mode vs. Shift Location: 5D44 Usage: 4L80-E Kickdown Mode Shift Thresholds Tips: Both MPH and RPM Qualifiers must be met before upshift will occur. See L5D68 "Upshift RPM for Hot Engine Mode". Conversion: MPH = 0.5 * X MPH 1 1000.000000 0 0 Shift 3 1000.000000 4 0 0 MPH 1 0.000000 255.000000 1 Downshift MPH for Hot Engine Mode vs. Shift Title: Downshift MPH for Hot Engine Mode vs. Shift Location: 5D47 Usage: 4L80-E Kickdown Mode Shift Thresholds Tips: Both MPH and RPM Qualifiers must be met before downshift will occur. See L5D68 "Upshift RPM for Hot Engine Mode". Conversion: MPH = 0.5 * X MPH 1 1000.000000 0 0 Shift 3 1000.000000 4 0 0 MPH 1 0.000000 255.000000 1 Upshift MPH for Hot Mode vs. Shift Title: Upshift MPH for Hot Mode vs. Shift Location: 5D4A Usage: 4L80-E Kickdown Mode Shift Thresholds Tips: Both MPH and RPM Qualifiers must be met before upshift will occur. See L5D62 "Upshift RPM for Hot Mode". Conversion: MPH = 0.5 * X MPH 1 1000.000000 0 0 Shift 3 1000.000000 4 0 0 MPH 1 0.000000 255.000000 1 Downshift MPH for Hot Mode vs. Shift Title: Downshift MPH for Hot Mode vs. Shift Location: 5D4D Usage: 4L80-E Kickdown Mode Shift Thresholds Tips: Both MPH and RPM Qualifiers must be met before downshift will occur. See L5D62 "Upshift RPM for Hot Mode". Conversion: MPH = 0.5 * X MPH 1 1000.000000 0 0 Shift 3 1000.000000 4 0 0 MPH 1 0.000000 255.000000 1 Upshift MPH Cold Modifier vs. Shift Title: Upshift MPH Cold Modifier vs. Shift Location: 5D50 Usage: 4L80-E Kickdown Mode Shift Thresholds Tips: MPH subtracted from shifts when engine/ transmission is cold. Conversion: MPH = 0.5 * X MPH 1 1000.000000 0 0 Shift 3 1000.000000 4 0 0 MPH 1 0.000000 255.000000 1 Downshift MPH Cold Modifier vs. Shift Title: Downshift MPH Cold Modifier vs. Shift Location: 5D53 Usage: 4L80-E Kickdown Mode Shift Thresholds Tips: MPH subtracted from shifts when engine/ transmission is cold. Conversion: MPH = 0.5 * X MPH 1 1000.000000 0 0 Shift 3 1000.000000 4 0 0 MPH 1 0.000000 255.000000 1 Upshift RPM vs. Shift Title: Upshift RPM vs. Shift Location: 5D56 Usage: 4L80-E Kickdown Mode Shift Thresholds Tips: Both MPH and RPM Qualifiers must be met before upshift will occur. See L5D3E "Upshift MPH" and L5D41 "Downshift MPH". Conversion: RPM = (1 * X) / 8 RPM 1 1000.000000 0 0 Shift 3 1000.000000 4 0 0 RPM 0 0.000000 255.000000 1 Upshift RPM Cold Modifier vs. Shift Title: Upshift RPM Cold Modifier vs. Shift Location: 5D5C Usage: 4L80-E Kickdown Mode Shift Thresholds Tips: RPM subtracted from shifts when engine/ transmission is cold. Conversion: RPM = (1 * X) / 8 RPM 1 1000.000000 0 0 Shift 3 1000.000000 4 0 0 RPM 0 0.000000 255.000000 1 Upshift RPM for Hot Mode vs. Shift Title: Upshift RPM for Hot Mode vs. Shift Location: 5D62 Usage: 4L80-E Kickdown Mode Shift Thresholds Tips: Both MPH and RPM Qualifiers must be met before upshift will occur. See L5D4A "Upshift MPH for Hot Mode" and L5D4D "Downshift MPH for Hot Mode". Conversion: RPM = (1 * X) / 8 RPM 1 1000.000000 0 0 Shift 3 1000.000000 4 0 0 RPM 0 0.000000 255.000000 1 Upshift RPM for Hot Engine Mode vs. Shift Title: Upshift RPM for Hot Engine Mode vs. Shift Location: 5D68 Usage: 4L80-E Kickdown Mode Shift Thresholds Tips: Both MPH and RPM Qualifiers must be met before upshift will occur. See L5D44 "Upshift MPH for Hot Engine Mode" and L5D47 "Downshift MPH for Hot Engine Mode". Conversion: RPM = (1 * X) / 8 RPM 1 1000.000000 0 0 Shift 3 1000.000000 4 0 0 RPM 0 0.000000 255.000000 1 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 ==== 4L80-E Normal Mode Shift Tables ================== 4L80-E Normal Mode Shift Tables 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 Manual Upshift/ Downshift MPH vs. TPS Title: Manual Upshift/ Downshift MPH vs. TPS Location: 5D6E Usage: 4L80-E Normal Mode Shift Tables Tips: Conversion: MPH = 0.5 * X Shift 6 1000.000000 4 0 0 % TPS 17 1000.000000 4 0 0 MPH 1 0.000000 255.000000 1 Cruise Control Upshift/ Downshift MPH vs. TPS Title: Cruise Control Upshift/ Downshift MPH vs. TPS Location: 5DD4 Usage: 4L80-E Normal Mode Shift Tables Tips: Conversion: MPH = 0.5 * X Shift 6 1000.000000 4 0 0 % TPS 17 1000.000000 4 0 0 MPH 1 0.000000 255.000000 1 Upshift/ Downshift MPH vs. TPS Title: Upshift/ Downshift MPH vs. TPS Location: 5E3A Usage: 4L80-E Normal Mode Shift Tables Tips: Conversion: MPH = 0.5 * X Shift 6 1000.000000 4 0 0 % TPS 17 1000.000000 4 0 0 MPH 1 0.000000 255.000000 1 Cold Engine Shift MPH vs. TPS Title: Cold Engine Shift MPH vs. TPS Location: 5EA0 Usage: 4L80-E Normal Mode Shift Tables Tips: Conversion: MPH = 0.5 * X Shift 6 1000.000000 4 0 0 % TPS 17 1000.000000 4 0 0 MPH 1 0.000000 255.000000 1 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 ==== 4L80-E Line Pressure Parameters ================= 4L80-E Line Pressure Parameters 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 Line Pressure Offset for A/C On vs. Gear Title: Line Pressure Offset for A/C On vs. Gear Location: 5F21 Usage: 4L80-E Garage Shift Parameters Tips: Conversion: PSI = 1 * X PSI 1 1000.000000 0 0 Gear 4 1000.000000 4 0 0 PSI 0 0.000000 255.000000 1 TPS Break Points vs. Table Offset Title: TPS Break Points vs. Table Offset Location: 5F28 Usage: 4L80-E Adaptive Learning Parameters Tips: Used with tables, "Line Pressure Correction vs. % TPS vs. Temperature", L6129 "2nd Gear", L6158 "3rd Gear", and L6187 "4th Gear". Conversion: % TPS = 0.390625 * X % TPS 1 1000.000000 0 0 Temp 4 1000.000000 4 0 0 % TPS 2 0.000000 255.000000 1 Line Pressure Modulation Time vs. Shift Title: Line Pressure Modulation Time vs. Shift Location: 5F2D Usage: 4L80-E Line Pressure Parameters Tips: Maximum time to modulate line pressure for shift. Conversion: Sec. = X / 40 Sec. 1 1000.000000 0 0 Shift 3 1000.000000 4 0 0 Sec. 1 0.000000 255.000000 1 PE Line Pressure vs. Input Speed Title: PE Line Pressure vs. Input Speed Location: 5F30 Usage: 4L80-E Line Pressure Parameters Tips: Added power enrichment line pressure vs. input speed. Conversion: PSI = (1 * X) - 128 PSI 1 1000.000000 0 0 RPM 17 1000.000000 4 0 0 PSI 0 0.000000 255.000000 1 Line Pressure Offset vs. MAT Title: Line Pressure Offset vs. MAT Location: 5F41 Usage: 4L80-E Line Pressure Parameters Tips: Conversion: PSI = (1 * X) - 128 PSI 1 1000.000000 0 0 C 17 1000.000000 4 0 0 PSI 0 0.000000 255.000000 1 Desired Shift Time Altitude Gain vs. TPS vs. Shift Title: Desired Shift Time Altitude Gain vs. TPS vs. Shift Location: 5F52 Usage: 4L80-E Line Pressure Parameters Tips: Conversion: Gain = X / 64 Shift 3 1000.000000 4 0 0 % TPS 17 1000.000000 4 0 0 Gain 1 0.000000 255.000000 1 Engine Braking Line Pressure vs. MPH vs. Gear Title: Engine Braking Line Pressure vs. MPH vs. Gear Location: 5F85 Usage: 4L80-E Line Pressure Parameters Tips: Conversion: PSI = 1 * X Gear 3 1000.000000 4 0 0 MPH 17 1000.000000 4 0 0 PSI 0 0.000000 255.000000 1 Line Pressure Compensation vs. Temperature vs. RPM (Drive) Title: Line Pressure Compensation vs. Temperature vs. RPM (Drive) Location: 5FBB Usage: 4L80-E Line Pressure Parameters Tips: Line pressure temperature compensation for shift into forward range. Conversion: PSI = 1 * X C 8 1000.000000 4 0 0 RPM 17 1000.000000 4 0 0 PSI 0 0.000000 255.000000 1 Line Pressure Compensation vs. Temperature vs. RPM (Reverse) Title: Line Pressure Compensation vs. Temperature vs. RPM (Reverse) Location: 6046 Usage: 4L80-E Line Pressure Parameters Tips: pressure temperature compensation for shift into reverse. Conversion: PSI = 1 * X C 8 1000.000000 4 0 0 RPM 17 1000.000000 4 0 0 PSI 0 0.000000 255.000000 1 Low Speed Line Pressure vs. MPH vs. TPS Title: Low Speed Line Pressure vs. MPH vs. TPS Location: 60D1 Usage: 4L80-E Line Pressure Parameters Tips: Conversion: PSI = 1 * X MPH 5 1000.000000 4 0 0 % TPS 17 1000.000000 4 0 0 PSI 0 0.000000 255.000000 1 Line Pressure Correction vs. % TPS vs. Temperature (2nd Gear) Title: Line Pressure Correction vs. % TPS vs. Temperature (2nd Gear) Location: 6129 Usage: 4L80-E Line Pressure Parameters Tips: Used with table at L5F28 "TPS Break Points vs. Table Offset". Conversion: PSI = (1 * X) - 128 % TPS 4 1000.000000 4 0 0 C 11 1000.000000 4 0 0 PSI 0 0.000000 255.000000 1 Line Pressure Correction vs. % TPS vs. Temperature (3rd Gear) Title: Line Pressure Correction vs. % TPS vs. Temperature (3rd Gear) Location: 6158 Usage: 4L80-E Line Pressure Parameters Tips: Used with table at L5F28 "TPS Break Points vs. Table Offset". Conversion: PSI = (1 * X) - 128 % TPS 4 1000.000000 4 0 0 C 11 1000.000000 4 0 0 PSI 0 0.000000 255.000000 1 Line Pressure Correction vs. % TPS vs. Temperature (4th Gear) Title: Line Pressure Correction vs. % TPS vs. Temperature (4th Gear) Location: 6187 Usage: 4L80-E Line Pressure Parameters Tips: Used with table at L5F28 "TPS Break Points vs. Table Offset". Conversion: PSI = (1 * X) - 128 % TPS 4 1000.000000 4 0 0 C 11 1000.000000 4 0 0 PSI 0 0.000000 255.000000 1 Added Line Pressure vs. TPS vs. 0 - 64 MPH Title: Added Line Pressure vs. TPS vs. 0 - 64 MPH Location: 61B6 Usage: 4L80-E Line Pressure Parameters Tips: Conversion: PSI = 1 * X MPH 17 1000.000000 4 0 0 % TPS 17 1000.000000 4 0 0 PSI 0 0.000000 255.000000 1 Added Line Pressure vs. TPS vs. 64 - 128 MPH Title: Added Line Pressure vs. TPS vs. 64 - 128 MPH Location: 62DA Usage: 4L80-E Line Pressure Parameters Tips: Conversion: PSI = 1 * X MPH 17 1000.000000 4 0 0 % TPS 17 1000.000000 4 0 0 PSI 0 0.000000 255.000000 1 Load Based Pressure Offset vs. TPS vs. Gear Title: Load Based Pressure Offset vs. TPS vs. Gear Location: 6643 Usage: 4L80-E Line Pressure Parameters Tips: Conversion: PSI = (1 * X) - 128 Gear 3 1000.000000 4 0 0 % TPS 17 1000.000000 4 0 0 PSI 0 0.000000 255.000000 1 2 -> 1 Line Pressure Modifier vs. MPH Title: 2 -> 1 Line Pressure Modifier vs. MPH Location: 66DF Usage: 4L80-E Line Pressure Parameters Tips: Conversion: PSI = (1 * X) - 128 PSI 1 1000.000000 0 0 MPH 17 1000.000000 4 0 0 PSI 0 0.000000 255.000000 1 3 -> 2 Line Pressure Modifier vs. MPH Title: 3 -> 2 Line Pressure Modifier vs. MPH Location: 66F3 Usage: 4L80-E Line Pressure Parameters Tips: Conversion: PSI = (1 * X) - 128 PSI 1 1000.000000 0 0 MPH 17 1000.000000 4 0 0 PSI 0 0.000000 255.000000 1 4 -> 3 Line Pressure Modifier vs. MPH Title: 4 -> 3 Line Pressure Modifier vs. MPH Location: 6707 Usage: 4L80-E Line Pressure Parameters Tips: Conversion: PSI = (1 * X) - 128 PSI 1 1000.000000 0 0 MPH 17 1000.000000 4 0 0 PSI 0 0.000000 255.000000 1 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 ==== 4L80-E TCC Tables ========================== 4L80-E TCC Tables 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 KICKDOWN PATTERN TCC ENGAGE/ RELEASE THRESHOLDS KICKDOWN PATTERN TCC ENGAGE/ RELEASE THRESHOLDS 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 Engage MPH vs. Gear Title: Engage MPH vs. Gear Location: 6AEE Usage: 4L80-E TCC Tables Tips: Conversion: MPH = 0.5 * X MPH 1 1000.000000 0 0 Gear 3 1000.000000 4 0 0 MPH 1 0.000000 255.000000 1 Release MPH vs. Gear Title: Release MPH vs. Gear Location: 6AF1 Usage: 4L80-E TCC Tables Tips: Conversion: MPH = 0.5 * X MPH 1 1000.000000 0 0 Gear 3 1000.000000 4 0 0 MPH 1 0.000000 255.000000 1 Hot Transmission Engage MPH vs. Gear Title: Hot Transmission Engage MPH vs. Gear Location: 6AF4 Usage: 4L80-E TCC Tables Tips: Conversion: MPH = 0.5 * X MPH 1 1000.000000 0 0 Gear 3 1000.000000 4 0 0 MPH 1 0.000000 255.000000 1 Hot Transmission Release MPH vs. Gear Title: Hot Transmission Release MPH vs. Gear Location: 6AF7 Usage: 4L80-E TCC Tables Tips: Conversion: MPH = 0.5 * X MPH 1 1000.000000 0 0 Gear 3 1000.000000 4 0 0 MPH 1 0.000000 255.000000 1 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 TCC ENGAGE/ RELEASE TRESHOLDS TCC ENGAGE/ RELEASE TRESHOLDS 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 Normal Mode Release MPH vs. TPS vs. Gear Title: Normal Mode Release MPH vs. TPS vs. Gear Location: 6AFA Usage: 4L80-E TCC Tables Tips: Conversion: MPH = 0.5 * X Gear 3 1000.000000 4 0 0 % TPS 17 1000.000000 4 0 0 MPH 1 0.000000 255.000000 1 Hot Mode Release MPH vs. TPS vs. Gear Title: Hot Mode Release MPH vs. TPS vs. Gear Location: 6B71 Usage: 4L80-E TCC Tables Tips: Conversion: MPH = 0.5 * X Gear 3 1000.000000 4 0 0 % TPS 17 1000.000000 4 0 0 MPH 1 0.000000 255.000000 1 Cruise Control On Release MPH vs. TPS vs. Gear Title: Cruise Control On Release MPH vs. TPS vs. Gear Location: 6BA4 Usage: 4L80-E TCC Tables Tips: Conversion: MPH = 0.5 * X Gear 2 1000.000000 4 0 0 % TPS 17 1000.000000 4 0 0 MPH 1 0.000000 255.000000 1 Normal Mode Engage MPH vs. TPS vs. Gear Title: Normal Mode Engage MPH vs. TPS vs. Gear Location: 6BC6 Usage: 4L80-E TCC Tables Tips: Conversion: MPH = 0.5 * X Gear 3 1000.000000 4 0 0 % TPS 17 1000.000000 4 0 0 MPH 1 0.000000 255.000000 1 Hot Mode Engage MPH vs. TPS vs. Gear Title: Hot Mode Engage MPH vs. TPS vs. Gear Location: 6C3D Usage: 4L80-E TCC Tables Tips: Conversion: MPH = 0.5 * X Gear 3 1000.000000 4 0 0 % TPS 17 1000.000000 4 0 0 MPH 1 0.000000 255.000000 1 Cruise Control On Engage MPH vs. TPS vs. Gear Title: Cruise Control On Engage MPH vs. TPS vs. Gear Location: 6C70 Usage: 4L80-E TCC Tables Tips: Conversion: MPH = 0.5 * X Gear 2 1000.000000 4 0 0 % TPS 17 1000.000000 4 0 0 MPH 1 0.000000 255.000000 1 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 ==== 4L80-E Force Motor Parameters ====================== 4L80-E Force Motor Parameters 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 FORCE MOTOR CURRENT VS. ADDED LINE FORCE MOTOR CURRENT VS. ADDED LINE PRESSURE VS. TRANS TEMPERATURE 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 PRESSURE VS. TRANS TEMPERATURE FORCE MOTOR CURRENT VS. ADDED LINE PRESSURE VS. TRANS TEMPERATURE 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 Line Pressure Rising Title: Line Pressure Rising Location: 6E5C Usage: 4L80-E Force Motor Parameters Tips: Used when desired line pressure is rising. Conversion: mA = X * 19.53 PSI 17 1000.000000 4 0 0 C 17 1000.000000 4 0 0 mA 1 0.000000 255.000000 1 Line Pressure Falling Title: Line Pressure Falling Location: 6F80 Usage: 4L80-E Force Motor Parameters Tips: Used when desired line pressure is falling. Conversion: mA = X * 19.53 PSI 17 1000.000000 4 0 0 C 17 1000.000000 4 0 0 mA 1 0.000000 255.000000 1 The End! 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1