0x1 1.0 VVL XDF for 1996-1997 P11/N15 Sr20ve/sr16ve CREDITS: Mark Mansur for providing TunerPro!! This XDF is provided without support, use at your own risk. R3SPCT - Darryl Stokes 0 0FF1 - ROM Label Table values in ASCII 5 1000.000000 4 0 0 1 1000.000000 4 0 0 0 0.000000 50.000000 3 ------ spacer 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 00100A - Injector K Value 2 0 0 0 0101A - Injector Voltage Adj Inj time + X*(14-Voltage)*(.0005)mS 2 0 0 01700 - VQ Table VQ Data 1 1000.000000 4 0 0 Voltage 64 1000.000000 4 0 0 0 0.000000 65000.000000 2 01610 - Water Temp Sensor Conversion Temperature sensor conversion table. scale: value-50= temperature in Celcius vs voltage (in steps of 0.16 volts) Temperature (°C) 1 1000.000000 4 0 0 Sensor Voltage 32 1000.000000 4 0 0 2 -50.000000 210.000000 1 ------ spacer 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 0101B - Injector Latency Affects idle performance. Typically 0.75 - 0.85 ms depending on injector size and brand. ms 0 0 01031 - Top Speed Limit KPH 0 0 01056 - 5th Gear Rev Limiter RPM 0 0 00h1c5c - Rev Limiter Rev limiter RPM 0 0 01038 - Feedback Control Flags Unkown 3 0 0 01037 - Unknown Something to do with injector and voltage response 2 0 0 013a0 - TTP Max Maximum Total Theoretical Pulsewidth in miliseconds Referenced against the fuel RPM scale? ms 1 1000.000000 4 0 0 RPM 16 1000.000000 2 0 0 2 0.000000 128.000000 1 01390 - TTP Min Minimum Total Theoretical Pulsewidth in miliseconds ms 1 1000.000000 4 0 0 RPM 16 1000.000000 2 0 0 2 0.000000 128.000000 1 ------ spacer 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 01100 - Primary Fuel Map - No Feedback TP Scale 16 1000.000000 2 0 0 RPM Scale 16 1000.000000 2 0 0 AFR 2 0.000000 100.000000 2 01e00 - Primary Fuel Map - Feedback Low Octane TP Scale 16 1000.000000 2 0 0 RPM Scale 16 1000.000000 2 0 0 AFR 2 -30.000000 30.000000 2 010E0 - RPM Scale - Fuel RPM scale use for the fuel maps RPM 1 1000.000000 4 0 0 Cell # 16 1000.000000 4 0 0 0 0.000000 10000.000000 1 010F0 - TP Scale - Fuel Theoretical Pulsewidth scale for the Fuel maps TP 1 1000.000000 4 0 0 TP Cell # 16 1000.000000 4 0 0 2 0.000000 128.000000 2 ------ spacer 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 01D00 - Primary Timing Map - Normal Timing advance in Degrees TP Scale 16 1000.000000 2 0 0 RPM Scale 16 0 1000.000000 2 0 0 Degrees Advance 2 0.000000 45.000000 2 01800 - Primary Timing Map - Knock Low Octane Timing advance in Degrees TP Scale 16 1000.000000 2 0 0 RPM Scale 16 0 1000.000000 2 0 0 Degrees Advance 2 0.000000 45.000000 2 01480 - RPM Scale - Timing RPM scale used for the timing maps RPM 1 1000.000000 4 0 0 Cell # 16 1000.000000 4 0 0 0 0.000000 7000.000000 1 01490 - TP Scale - Timing Theoretical Pulsewidth scale for the Timing maps TP (ms) 1 1000.000000 4 0 0 TP Cell # 16 1000.000000 4 0 0 2 0.000000 128.000000 2 ------ spacer 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 01320 - Engine Cranking Inj Pulsewidth Additional injector pulse width in relation to water temperature 1 1000.000000 4 0 0 Temperature 16 1000.000000 4 0 0 2 0.000000 128.000000 2 01310 - Engine Cranking Additional Enrichment This is added to inj pw at engine cranking mS 1 1000.000000 4 0 0 Temperature 16 1000.000000 4 0 0 2 0.000000 128.000000 1 01330 - Engine Cranking Pulse Offset 1 1000.000000 4 0 0 Temperature 16 1000.000000 4 0 0 2 0.000000 255.000000 2 01450 - Engine Cranking Ign Timing Engine cranking ignition timing vs water temp DEG 1 1000.000000 4 0 0 Temperature 16 1000.000000 4 0 0 DEG 0 0.000000 30.000000 2 ------ spacer 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 01220 - Spray Water Temp Offset 1 1000.000000 4 0 0 Temperature 16 1000.000000 4 0 0 2 0.000000 255.000000 2 ------ spacer 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 014A0 - Timing Advance - Normal Timing advance vs water temp + BTDC 1 1000.000000 4 0 0 Temperature °C 16 1000.000000 4 0 0 2 0.000000 25.000000 2 014B0 - Timing Advance - Deceleration Timing advance vs water temp when decelerating + BTDC 1 1000.000000 4 0 0 Temperature °C 16 1000.000000 4 0 0 2 0.000000 25.000000 2 ------ spacer 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 010D0 - Water Temp RPM Gain 1 1000.000000 4 0 0 Temperature 16 1000.000000 4 0 0 2 0.000000 255.000000 2 ------ spacer 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 014C8 - Idle Stabalization Timing Retard Idle timing control DEG 1 1000.000000 4 0 0 8 1000.000000 4 0 0 DEG 0 0.000000 16.000000 1 01660 - Base Idle RPM RPM 1 1000.000000 4 0 0 -C 16 1000.000000 4 0 0 RPM 2 500.000000 3000.000000 1 01460 - Base Idle Timing - In Neutral idle timing vs water temp °BTDC 1 1000.000000 4 0 0 °C 16 1000.000000 4 0 0 0 0.000000 25.000000 2 01470 - Base Idle Timing - In Gear idle timing vs water temp °BTDC 1 1000.000000 4 0 0 °C 16 1000.000000 4 0 0 0 0.000000 25.000000 2 ------ spacer 1 1000.000000 4 0 0 1 1000.000000 4 0 0 2 0.000000 255.000000 1 201C40 INTAKE CAM RPM EXHAUST 16 1000.000000 4 0 0 1 1000.000000 4 0 4 1 1000.000000 9000.000000 2